• Title/Summary/Keyword: Handheld

Search Result 278, Processing Time 0.028 seconds

User Satisfaction of Mobile Convergence Device: The Expectation and Disconfirmation Approach (모바일 복합 단말기 사용자 만족: 기대-불일치 접근)

  • Lee, Seung-Chang;Suh, Eung-Kyo
    • Journal of Distribution Science
    • /
    • v.10 no.11
    • /
    • pp.89-99
    • /
    • 2012
  • Purpose - Mobile devices, especially mobile terminals capable of telecommunication and wireless connectivity, are leading the advancements in consumer electronics. Digital convergence drives the functions of various devices, such as cellular phones, MP3 players, personal digital assistants, and gaming, into a single device. This trend would continue and applications such as digital audio and video streaming (including personalized content delivery mechanisms) would soon be on a handheld device. As customers want mobile convergence devices, manufacturers are driving new initiatives in the emerging mobile device market. Given the roles played by device design and service content in user satisfaction of a mobile convergence device, this study focuses on identifying and measuring the constructs for the process by which user satisfaction is achieved. This study synthesizes the expectation-disconfirmation paradigm with empirical theories in user satisfaction. Device and service levels are separated, and nine key constructs for user satisfaction of mobile convergence devices are proposed. Insight into this process could help web-based businesses to improve user satisfaction, thus enhancing the effectiveness of e-commerce for sellers and buyers. Research design, data, methodology - This study draws on three users of mobile convergence devices as examples. To test there search model and hypotheses, survey questionnaires were sent to 607 mobile device users. Mobile device users were initially identified from several members, and subjects were randomly drawn. Data from 577 survey responses were finally analyzed. The unit of measurement and analysis in this research study is at a personal level. Results - The measurements for the constructs were developed and tested in a two-phase study. In the first phase, the device and service dimensions were identified, and instruments for measuring them were developed and tested. In the second phase, using the salient dimensions of the device and service as the formulating first-order factors, instruments were developed and empirically tested to measure satisfaction of the device and service. In measuring satisfaction of mobile convergence devices, the critical tasks are to identify the key constructs of such user satisfaction and to develop validated instruments to measure them. Hence, the results of this study have immediate implications for businesses and for research in user satisfaction of mobile convergence devices. Conclusions - This study provides reliable instruments for operationalizing key constructs in the analysis of user satisfaction of mobile convergence devices within the expectation-disconfirmation paradigm. Hence, convergence device makers will be able to examine whether their websites meet their customers' expectations by examining the device aspect of the mobile convergence device customers, and the service aspect expectations and disconfirmation. Moreover, the introduction of expectation and disconfirmation constructs brings the marketing aspect of convergence devices into focus for such retailers, an aspect crucial to the effective design of websites for online businesses. In addition,this study provides the metrics required to initiate future studies on user satisfaction of mobile convergence devices.

  • PDF

A 12b 100MS/s 1V 24mW 0.13um CMOS ADC for Low-Power Mobile Applications (저전력 모바일 응용을 위한 12비트 100MS/s 1V 24mW 0.13um CMOS A/D 변환기)

  • Park, Seung-Jae;Koo, Byeong-Woo;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.8
    • /
    • pp.56-63
    • /
    • 2010
  • This work proposes a 12b 100MS/s 0.13um CMOS pipeline ADC for battery-powered mobile video applications such as DVB-Handheld (DVB-H), DVB-Terrestrial (DVB-T), Satellite DMB (SDMB), and Terrestrial DMB (TDMB) requiring high resolution, low power, and small size at high speed. The proposed ADC employs a three-step pipeline architecture to optimize power consumption and chip area at the target resolution and sampling rate. A single shared and switched op-amp for two MDACs removes a memory effect and a switching time delay, resulting in a fast signal settling. A two-step reference selection scheme for the last-stage 6b FLASH ADC reduces power consumption and chip area by 50%. The prototype ADC in a 0.13um 1P7M CMOS technology demonstrates a measured DNL and INL within 0.40LSB and 1.79LSB, respectively. The ADC shows a maximum SNDR of 60.0dB and a maximum SFDR of 72.4dB at 100MS/s, respectively. The ADC with an active die area of 0.92 $mm^2$ consumes 24mW at 1.0V and 100MS/s. The FOM, power/($f_s{\times}2^{ENOB}$), of 0.29pJ/conv. is the lowest of ever reported 12b 100MS/s ADCs.

Simulation of Counting Efficiencies of Portable NaI Detector for Rapid Screening of Internal Exposure in Radiation Emergencies (방사선비상시 내부피폭 신속 분류를 위한 휴대용 NaI 검출기의 계측효율 전산모사)

  • Ha, Wi-Ho;Yoo, Jaeryong;Yoon, Seokwon;Pak, Min Jung;Kim, Jong Kyoung
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.211-215
    • /
    • 2015
  • In case of radiation emergencies, radioactive materials released into environments can cause internal exposure of members of the public. Even though whole body counters are widely used for direct measurement of internally deposited radionuclides, those are not likely to be used at the field to rapidly screen internal exposure. In this study, we estimated the counting efficiencies of portable NaI detector for different size BOMAB phantoms using Monte Carlo transport code to apply handheld gamma spectrometers for rapid screening of internal exposure following radiological accidents. As a result of comparison for two counting geometries, counting efficiencies for sitting model were about 1.1 times higher than those for standing model. We found, however, that differences of counting efficiencies according to different size are higher than those according to counting geometry. Therefore, we concluded that when we assess internal exposure of small size people compared to the reference male, the body size should be considered to estimate more accurate radioactivity in the human body because counting efficiencies of 4-year old BOMAB phantom were about 2.4~3.1 times higher than those of reference male BOMAB phantom.

Sentinel Lymph Node Identification Using $^{99m}Tc$-Neomannosyl Human Serum Albumin in Esophageal Cancer; Comparison with $^{99m}Tc$-Phytate (식도암 환자에서 $^{99m}Tc$-Neomannosyl Human Serum Albumin과 $^{99m}Tc$-Phytate를 이용한 감시림프절 탐색의 비교)

  • Kim, Hyun-Koo;Kang, Du-Young;Kim, Seung-Eun;Park, Jong-Jae;Jeong, Jae-Min;Mok, Young-Jae;Choi, Young-Ho
    • Korean Journal of Bronchoesophagology
    • /
    • v.16 no.2
    • /
    • pp.109-114
    • /
    • 2010
  • Background: The aim of this study was to compare a novel mannose receptor-binding agent(Technetium-99m human serum albumin, $^{99m}Tc$-MSA) with $^{99m}Tc$-phytate for sentinel node mapping in patients with esophageal cancer. Material and Method: Twenty patients with clinical stage T1N0m0 or T2N0M0 esophageal cancer that were candidates for esophagectomy were enrolled. Endoscopic injection of $^{99m}Tc$-MSA or $^{99m}Tc$-phytate was administered at the peri-tumor region before surgery in 10 patients. The radioactive lymph nodes were identified with a handheld gamma probe after lymph node dissection. Results: The patient's age and the sex ratio of both groups were similar. The clinical stage, tumor location, and operative technique did not differ. The total number of dissected lymph nodes did not differ ($28.5{\pm}9.12$ in MSA group, $32.2{\pm}11.24$ in phytate group, p=0.430). The sentinel node was identified in all cases in both groups. The number of sentinel nodes per patient was $2.7{\pm}1.57$ in the MSA group, which was significantly greater than the $1.7{\pm}0.88$ in the phytate group (p=0.036). Five out of 20 patients whose sentinel nodes could be identified had metastases; however, neither group had any false-negative results for sentinel node identification. Conclusion: Sentinel nodes were detected more frequently with MSA than with phytate.

  • PDF

Evaluation of Field Application of Portable Near Infrared Reflectance Spectrometer (NIRS) for Quality Evaluation of Italian Ryegrass Silages (신속한 이탈리안라이그라스 사일리지의 품질평가를 위한 소형 근적외선분광기(NIRS)의 현장 적용성 평가)

  • Park, Hyung-Soo;Lee, Sang-Hoon;Kim, Jong-Gun;Choi, Ki-Choon;Seo, Sung;Kim, Won-Ho;Lee, Hyo-Won;Lim, Young-Chul
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.31 no.4
    • /
    • pp.415-422
    • /
    • 2011
  • This study evaluated the feasibility of using a portable near infrared reflectance spectrometer working in the 900~1,600 nm range for the measurement of quality-related parameters (moisture, pH, Acid detergent fiber (ADF), Neutral detergent fiber (NDF), Crude protein (CP), lactic acid) in intact silage. The calibration result for the Phazir (handheld, Polychromix) was compared with the result for the Spectrastar (Lab. based, Unity). A total of 67 Italian ryegrass silages were used to build calibration models using different spectral signal pre-treatments and the partial least squares regression (PLS) method. The good calibration statistics in two instruments was obtained for moisture content of Italian ryegrass silages with over $R^2$ = 0.95. The Phazir spectrometer was less accurate in measuring of ADF, NDF and CP contents. The Spectrastar instrument yielded greater precision for pH and lactic acid content; statistic values were over $R^2$ = 0.82 and the standard error of calibration (SEC) = 0.21% and 0.24%. Thus, the NIR measurement of forage quality in the field by portable NIR analyzers was shown not to be feasible, but additional investigations are required to discern the key instrumental and operational parameters that may influence the portable NIR measurement.

Effects of Display Size of Digital Media on the Reliability of the Information Contents (디지털미디어의 화면 크기로 인한 사용성의 차이가 기사 정보의 신뢰도에 미치는 영향)

  • Ki, Hyun-Young;Lee, Ju-Hwan
    • Science of Emotion and Sensibility
    • /
    • v.15 no.1
    • /
    • pp.65-72
    • /
    • 2012
  • People receive information through various media, such as newspapers, TV, radio, magazines, or internet, etc. In particular, through the development of the internet and smart-phone they can interact with media and receive information in real time via handheld devices. However the types of information and media could affect the reliability of news information. In this study, it was the main interest how the usability in the new media with the interactivity, such as a desktop, tablet, and smart-phone affects the user's evaluation on the contents displayed by the different new media. Therefore, the present study was conducted to investigate the effect of the usability from the different display size of media and the different contents of articles on the reliability of information empirically. The results showed that the contents of the articles interacting with different devices affect the reliability of information. These findings propose the considerations on the effects of characteristic usability of the new media in the stages of the development of the media contents.

  • PDF

Auto Exposure Control System using Variable Time Constants (가변 시상수를 이용한 자동 노출제어 시스템)

  • Kim, Hyun-Sik;Lee, Sung-Mok;Jang, Won-Woo;Ha, Joo-Young;Kim, Joo-Hyun;Kang, Bong-Soon;Lee, Gi-Dong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.2
    • /
    • pp.257-264
    • /
    • 2007
  • In order to obtain a fine picture, a camera has many convenient functions. Its representative functions are Auto Focus(AF), Auto White Balance(AWB) and Auto Exposure(AE). In this paper, we present the new algorithm of Auto Exposure control system, one of its useful functions The proposed algorithm of Auto Exposure control system is based on IIR Filter with Variable Time Constant. First, in order to establish the standards of exposure control, we compare change of the picture luminance with luminance of an object in the Zone system. Second, we make an ideal characteristic graph of luminance by using the results. Finally, we can find the value of the right exposure by comparing an ideal characteristic graph of the luminance with the value of the current expose of a scene. We can find an appropriate exposure as comparing the ideal characteristic graph of the luminance with current exposure of a scene. In order to find a suitable exposure state, we make use of IIR Filter instead of a conventional method using micro-controller. In this paper, the proposed system has therefore simple structure, we use it for compact image sensor module used in the handheld device.

The Effects of Therapeutic exercise with Electrical Stimulation on Pain, Range of motion, Muscle strength in patients after Anterior Cruciate Ligament Reconstruction (전기자극치료를 동반한 운동치료가 전방십자인대 재건술 환자의 통증, 관절가동범위, 근력에 미치는 영향)

  • Min, Dong-Ki;Lee, Sang-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.694-703
    • /
    • 2019
  • This study was to investigate the effect of therapeutic exercise with electrical stimulation on knee joint pain, range of motion and muscle strength in patients who underwent anterior cruciate ligament reconstruction. The subjects of this study were recruited who diagnosed with anterior cruciate ligament rupture and undergoing anterior cruciate ligament reconstruction, total of 20 patients were randomly divided to the 10 control groups and 10 experimental groups. The therapeutic exercise was carried out for 3 weeks with three exercises made by referring to the previous study. The measurement tools used were knee joint pain measurements were made using the visual analogue scale, range of motion was measured using a goniometer, and the muscle strength was measured using a handheld dynamometer. In the statistical analysis, to compare about pre and post test the difference in each same groups was accomplished by using the paired t-test, and compare the difference between the different each groups was accomplished by using the independent t-test. The results of the study showed that the experimental group showed significantly enhanced results than the control group(p<.05). Based on these results, it is concluded that it is effective for the recovery of the patient if the therapeutic exercise with electrical stimulation in parallel with knee joint therapy are performed for the patients with anterior cruciate ligament reconstruction.

A Visualization Technique of Inter-Device Packet Exchanges to Test DLNA Device Interoperability (DLNA 기기의 상호운용성 시험을 위한 패킷교환정보 시각화 방법)

  • Kim, Mijung;Jin, Feng;Yoon, Ilchul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.531-534
    • /
    • 2014
  • DLNA is an established industry standard which supports contents sharing among smart devices in home wired- and wireless-network environment and is well known in Korea as Allshare or Smartshare. The DLNA standard is implemented as built-in services in most of Android smart phones and tablets. In addition to the handheld devices, DLNA service can also be employed in speakers, printers, and so on. However, users have reported many interoperability issues between DLNA devices. Developers typically identify causes by analyzing the packet exchange information between devices. However, this approach costs them to put additional effort to filter relevant packets, to reconstruct packet exchange history and the protocol flow. Consequently, it ends up with increased development time. In this paper, we demonstrate a technique to automatically analyze and visualize the packet exchange history. We modified a router firmware to capture and store packets exchanged between DLNA devices, and then analyze and visualize the stored packet exchange history for developers. We believe that visualized packet exchange history can help developers to test the interoperability between DLNA devices with less effort, and ultimately to improve the productivity of developers.

  • PDF

Applying Rosen-type PZT plasma generation device for medical applications (로젠형 압전변압기를 적용한 의료융합 플라즈마기기)

  • Lee, Kang-yeon;Jung, Byung-Geun;Park, Jeong-sook;Park, Ju-Hoon;Jeong, Byeong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.1
    • /
    • pp.243-250
    • /
    • 2021
  • In the medical field, applications of plasma are applied sterilize instruments mainly but with the advent of bio-plasma technology, the scope of application is expanding. Recently, In addition, high-density miniaturization with handheld is required for sophisticated procedures when irradiated directly or treated with non-standard conditions. Rosen-type PZT is a device with a structure that generates high voltage plasma by achieving voltage transformation through electro-mechanical coupling using piezoelectric effect.and is used in portable plasma generating devices as an advantage to increase energy density relatively. In this paper, Rosen-type PZT was modeled using equivalent circuits and was carried out and a plasma generating device for medical application was designed and prototype tested. Prototype plasma generating device generates an output voltage of 5.8 kV with 12V input power and is designed to operate at high voltage by applying the half-bridge topology power converter. The results of the study confirmed the availability of various medical devices, such as plasma jets or direct exposure equipment.