• Title/Summary/Keyword: Hand-operated

Search Result 332, Processing Time 0.026 seconds

Effect of Neurodynamics on Pain and Paresthesia in Post-operated Patients with Lumbar Disc Herniation

  • Jang, Ki-ryong;Park, Ji-Won;Nam, Kiseok
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.2
    • /
    • pp.80-87
    • /
    • 2020
  • Purpose: Some patients who have undergone surgery due to lumbar disc herniation still complain of leg pain and other abnormal sensations. Therefore, the study examined the effects of the neurodynamics on pain and other abnormal nerve sensations in post-operated patients with lumbar disc herniation. Methods: The participants of this study comprised 20 adults (10 males and 10 females) who were diagnosed with lumbar disc herniation. The subjects were classified into two groups of 10 patients each in the lower extremity neurodynamics (LEN) and lumbar stabilization exercise (LSE) groups. Each intervention was applied twice a day for one week and was composed of two different exercise patterns; one was applied by a therapist, and the other was performed by the patients themselves. The data were analyzed using assessment methods of Digital Infrared Thermal Imaging (DITI), Toronto clinical neuropathy scoring system (TCNSS), Sympathetic Skin Response (SSR) test, and Oswestry Disability Index (ODI) scale. Results: Significant differences in TCNSS, DITI, ODI scale were observed between the LEN and LSE group (p<0.01). On the other hand, there was no significant difference in the SSR test between pre and post-treatment (p>0.05). Conclusion: The results indicated that neurodynamics treatment is effective in pain reduction and abnormal sensations, such as leg muscle cramps, in post-operated patients with lumbar disc herniation.

Effects of hand grip strength on shoulder muscle activity in breast cancer patients

  • Yun, Tae-Won;Lee, Byoung-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.2
    • /
    • pp.95-100
    • /
    • 2016
  • Objective: The purpose of this study was to investigate effects of hand grip strength on the muscle activation of shoulder joint in breast cancer patients. Design: Cross-sectional study. Methods: Ten breast cancer patients who agreed to active participation were included. These patients were operated with either conservative surgery or segmental mastectomy, and then were treated with radiation therapy and chemotherapy. The activity of the upper trapezius, lower trapezius, supraspinatus and serratus anterior muscle were measured using surface electrodes during 4 hand gripping tasks (lowered their arms in standing position, 0%, 30%, and 50% of maximum voluntary contraction) in the scapular abduction plane. Results: The results were analyzed using a one-way repeated measures ANOVA. There was a significant difference in the lower trapezius and supraspinatus muscles according to grip strength, lower trapezius and supraspinatus muscles showed significantly difference according to grip strength (p<0.05). The result of the muscle activation according to hand strength (0%, 30%, and 50%) it showed a significant difference between the upper trapezius and supraspinatus in 0% grip strength (p<0.05). In addition, it did not show a significant difference between muscles in 30%, 50% hand strength. Conclusions: This study showed an increase in shoulder muscle activation with increasing hand grip strength with the upper trapezius muscle being more activated than other muscles in 0% grip strength. The finding of this study suggests usefulness for development of preventative measures and rehabilitation strategies for increasing shoulder motor function in patients with breast cancer.

A study on the pulse wave factor according to BMI and period of sterility on female (난임 여성의 체질량지수(BMI), 불임기간에 따른 맥파 연구)

  • Kim, Gyeong-Cheol;Kim, Yi-Soon
    • Korean Journal of Oriental Medicine
    • /
    • v.18 no.2
    • /
    • pp.139-149
    • /
    • 2012
  • Objectives : This is the study to understand of the pulse wave factor according to BMI and period of sterility on female, and to confirm the relationship of pulse wave factor among left and right inch, bar and cubit. Methods : The Questions and measurement of the pulse wave were operated with subjects(76 sterile females using on public health center). The measurement of the pulse wave was operated in 6 part of left and right inch, bar and cubit. The pulse wave was prior measured in part of left bar (i.e. interior pulsation part of radial process styloides in left hand), and next was measured in part of left inch and bar. And the pulse wave was operated samely in part of right inch, bar and cubit. Results : The results were as follows. The pulse energy of 6 part of left and right inch, bar and cubit was showed statistical significance and decreased in order of left inch, right inch, left cubit, right cubit, left inch, right bar. The left and right inch and cubit were showed numerical value of normal range, but left and right bar were showed lower pulse eneregy than normal range. Also left and right cubit were showed lower than left and right inch, and higher than left and right bar. In BMI, The pulse energy of left and right inch, cubit and the average of right hand was not showed statistical significance in the range of low-weight, normal, over-weight and obesity. But in the left and right bar and the average of left hand, the pulse energy of over-weight and obesity group were showed significantly higher than low-weight group. And the pulse wave factor was divided the pattern of h1 showing high numerical value in inch (Ap, As, Aw) and the pattern of Wm showing high numerical value in bar and cubit (RAI, Ad) Conclusions : The low pulse energy of bar was significant observation on the setting of oriental medical diagnostic index on sterilitas. Also, in the numerical value pattern of diverse pulse wave factor, it was divided the pattern of high numerical value in inch and the pattern of high numerical value in bar and cubit. On this, we think that the studies need in the future.

Real-time moving object tracking and distance measurement system using stereo camera (스테레오 카메라를 이용한 이동객체의 실시간 추적과 거리 측정 시스템)

  • Lee, Dong-Seok;Lee, Dong-Wook;Kim, Su-Dong;Kim, Tae-June;Yoo, Ji-Sang
    • Journal of Broadcast Engineering
    • /
    • v.14 no.3
    • /
    • pp.366-377
    • /
    • 2009
  • In this paper, we implement the real-time system which extracts 3-dimensional coordinates from right and left images captured by a stereo camera and provides users with reality through a virtual space operated by the 3-dimensional coordinates. In general, all pixels in correspondence region are compared for the disparity estimation. However, for a real time process, the central coordinates of the correspondence region are only used in the proposed algorithm. In the implemented system, 3D coordinates are obtained by using the depth information derived from the estimated disparity and we set user's hand as a region of interest(ROI). After user's hand is detected as the ROI, the system keeps tracking a hand's movement and generates a virtual space that is controled by the hand. Experimental results show that the implemented system could estimate the disparity in real -time and gave the mean-error less than 0.68cm within a range of distance, 1.5m. Also It had more than 90% accuracy in the hand recognition.

Design of a dual band circularly polarized antenna for 900 MHz / 2.45 GHz Hand-held RFID Reader (900 MHz / 2.45 GHz 대역 휴대용 FRID 리더를 위한 이중 대역 원형편파 안테나 설계)

  • Kim, Jeong-Pyo;Lee, Yoon-Bok;Seong, Won-Mo;Choi, Jae-Hoon
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.235-240
    • /
    • 2005
  • This paper presents a dual band circularly polarized microstrip patch antenna. The antenna consists of two corner truncated patches implemented in one plane and single feed point. The input signal is directly excited to the patch 2 and the patch 1 is fed from patch 2 by coupling between two patches. The antenna is operated at 900 MHz and 2.45 GHz bands and has the right hand circularly polarized radiation pattern at all. The measured gains of the antenna are 2.95 dBic at 900 MHz band and 4.6 dBic at 2.45 GHz band.

  • PDF

A Study on High Accuracy Bending Work using Servo Control of Bending Machine (Bending Machine의 서보제어에 의한 고정도 굽힘가공에 관한 연구)

  • 송충현;김성식;김경석
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.85-90
    • /
    • 2001
  • Recent general Press brake has many problems in cutting high accurate products in the progress of industry. Previous hand-operated press brake needs many pre-processing works to adjust bending ang1e and marking-off works to calculate bending length. Also, the hand-operating work makes many geometric errors and has difficulty for variety-mass production. To solve these problems, this paper proposes Computer Numerical Control (CNC) general press brake and development of servo-control system based on database for reduction of geometric errors and pre-processing work time and high accuracy bending work.

  • PDF

A Study on the Servo Control of Bending Machine (Bending Machine의 서보제어에 관한 연구)

  • 송충현;김성식;김경석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.410-413
    • /
    • 1997
  • Recent general press brake has many problems in cutting high accurate products in the progress of industry. Previous hand-operated press brake needs many pre-processing works to adjust bending angle and marking-off works to calculate bending length. Also, The hand-operating work makes many geometric errors and has difficulty for variety-mass production. To solve these problems, this paper proposes Computer Numerical Control (CNC) general press brake and development of servo-control system based on database for reduction of geometric errors and pre-processing work time.

  • PDF

Training-Free sEMG Pattern Recognition Algorithm: A Case Study of A Patient with Partial-Hand Amputation (무학습 근전도 패턴 인식 알고리즘: 부분 수부 절단 환자 사례 연구)

  • Park, Seongsik;Lee, Hyun-Joo;Chung, Wan Kyun;Kim, Keehoon
    • The Journal of Korea Robotics Society
    • /
    • v.14 no.3
    • /
    • pp.211-220
    • /
    • 2019
  • Surface electromyogram (sEMG), which is a bio-electrical signal originated from action potentials of nerves and muscle fibers activated by motor neurons, has been widely used for recognizing motion intention of robotic prosthesis for amputees because it enables a device to be operated intuitively by users without any artificial and additional work. In this paper, we propose a training-free unsupervised sEMG pattern recognition algorithm. It is useful for the gesture recognition for the amputees from whom we cannot achieve motion labels for the previous supervised pattern recognition algorithms. Using the proposed algorithm, we can classify the sEMG signals for gesture recognition and the calculated threshold probability value can be used as a sensitivity parameter for pattern registration. The proposed algorithm was verified by a case study of a patient with partial-hand amputation.

A Study on the Development of an Electronic Component Assembly Training System Using Leap Motion (Leap Motion을 이용한 전자부품 조립 훈련 시스템 개발에 관한 연구)

  • In-Chul Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.3
    • /
    • pp.463-470
    • /
    • 2023
  • In this study, an electronic parts assembly training system using Leap Motion was developed in consideration of the processes actually operated in the assembly process of electronic products. Based on Leap Motion and Oculus VR equipment, the system was developed to transfer user's hand movement data in real time and convert it into hand movement in virtual space so that electronic parts assembly simulation can be performed step by step. Through this, it was confirmed that the user can obtain an experience similar to the actual electronic parts assembly work, prevent errors that may occur during the assembly process, and improve proficiency. It is expected that this thesis will provide directions for the quality improvement and development of various education and training programs for virtual reality-based manufacturing processes.

Operation characteristics of partial oxidation reformer for transportation fuels (수송 연료용 부분산화 개질기의 운전특성)

  • Lee, Sangho;Bae, Joongmyeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.159.1-159.1
    • /
    • 2011
  • Partial oxidation reformer was fabricated and operated using commercial transportation fuels. Fuel injector and heating coil were used for fuel atomization and startup, respectively. The reformer was designed to produce syngas for $150{\sim}200W_e$ class solid oxide fuel cell. The reformer was operated in the $O_2$/C range between 0.6 and 0.8 while the capacity was fixed at $150W_e$. The temperature range in catalyst bed was between $500^{\circ}C$ and $900^{\circ}C$. Only 83% fuel was converted to $H_2$, CO, $CO_2$ and $CH_4$ at the operating conditions. The lowest temperature increase to $700^{\circ}C$ when the reformer was operated at $200W_e$, Although the temperature profiles was improved, fuel conversion was 88%. On the other hand, fuel was completely converted when micro-reactor operated at the same condition. This difference maybe due to aromatic compounds formation at homogeneous region. In addition, a significant amount of coke deposition was observed at vent line. Homogeneous reaction depends on the degree of mixing. For this purpose, two fluid nozzle and Ultra sonic injector were compared to investigate the effect of atomization. Sauter mean diameter(SMD) of Ultra sonic injector was lower than two-fluid nozzle at test condition. However, conversion efficiency and fuel conversion were not improved by using two-fluid nozzle. these results imply that the temperature of homogeneous reaction region should be controlled to prevent coke formation.

  • PDF