• 제목/요약/키워드: Hand-arm system

검색결과 108건 처리시간 0.024초

Eco Resort Wear Sizing System Targeting Jeju's Medical Tourists

  • Kwon, Sookhee;Hong, Jiun
    • 대한인간공학회지
    • /
    • 제31권6호
    • /
    • pp.765-772
    • /
    • 2012
  • Objective: The purpose of this research was to aid creating an effective sizing system for the vacation wear intended for Jeju's medical tourists, specifically females from the major countries including the USA, Japan, and Korea. Background: Medical tourism makes the gains of every year 40,000,000,000 dollar, every year 30% it is increasing. Thus the Jeju-do is propelling medical tourism. The body size each country is different. Consequently must set the body size standard for the women. Method: (1) It observed the body size of the Korean women of 2004 years and 2010 years. (2) It analyzed the body size of the women of the USA, China, Japan and Korea. (3) It set the sizing system of the women of the USA(ASTM), China (GB), Japan(JIS) and Korea(KS). Results: Korean adult females' height in 2010 has increased from 2004. The Waist Back Length, Waist Front Length, Arm Length etc has also increased along with the Height. The upper body has become slimmer at the same time; the Chest Circumference, Bust Circumference, and Underbust Circumference have decreased. The lower body on the other hand has become bigger: the Waist Circumference and Hip Circumference have increased. The BMI has decreased by 0.4 from 2004 - the Height has increased while Weight has decreased. The Chest Circumference and Under Bust Circumference of Korean women across all age groups have increased at a proportional rate to other parts of body; however, the rate of increase in Chest Circumference was far greater. American females(Caucasians) had the greatest ratio of waist to bust (Waist Circumference/Chest Circumference), smallest ratio of Neck Base Circumference to Bust Circumference (neck/bust). Korean females had smallest ratio of Waist Circumference to Underbust Circumference(waist/bust). As for the drop of Chest Circumference and Waist Circumference, American females had the highest and Koreans had the lowest. As for the drop of Hip Circumference and Chest Circumference, Japanese had the highest and Americans had the lowest, but Japanese women at the same time showed the A line body shapes. As for difference of Chest Circumference and Underbust Circumference, American females had the biggest(13.73) followed by Korean(11.1), Japanese(10.9) and Chinese(10.5). Conclusion: The women of the USA, China, Japan and Korea body size is different. Especially the value of the Bust Circumference - the Underbust Circumference is different. Thus, it set the sizing system(Table 8).

Smith-Magenis Syndrome (SMS) 환아의 증례 보고 (SMITH-MAGENS SYNDROME (SMS) : A CASE REPORT)

  • 김은영;이긍호;최영철
    • 대한소아치과학회지
    • /
    • 제30권3호
    • /
    • pp.341-347
    • /
    • 2003
  • Smith-Magenis syndrome(이하 SMS)은 제 17번 상염색체의 부분적 결손으로 발생하는 다발성 선천적 기형 및 정신지체를 특징으로 하는 증후군으로 1 : 25,000의 빈도로 발생하는 것으로 알려져 있다. 이 증후군은 작은 키와 단두증(brachycephaly)을 동반한 편평한 중안면, 처진 입, 종종 두드러지게 붉은 뺨, 성인에서 돌출된 턱 등의 특징적인 얼굴 생김새, 만성이염, 청각 손상, 사시와 근시를 포함한 눈의 이상, 목 쉰 소리, 짧은 손가락과 발가락, 심장 질환, 비뇨기 질환, 척추 만곡, 비정상적 걸음걸이, 통각에 둔감함 등의 신체적 특징을 지닌다. 특히 유아기에는 토실토실한 아기 얼굴, 행복한 기분, 드문 울음소리, 낮은 근 긴장도, 섭식 장애 등의 특징이 있다. 수면 장애를 포함하여 언어 지체 및 발음 장애, 발달지체, 학습 장애, 정신지체, 활동항진과 자해, 폭발적 분노, 지속되는 짜증, 파괴적이고 공격적인 행동, 흥분성, 흥분시에 팔로 안거나 손을 끼우는 행동 등의 행동 발달적 특징을 나타낸다. 본 증례는 3세 3개월된 남아로 생후 10개월에 SMS를 진단받은 환자로 상악 좌측 제 1유구치의 통증을 주소로 본과에 내원하였으며, 임상 및 방사선학적으로 다발성 우식증을 보였으며, 소아과 주치의에게 의뢰한 결과 심내막염의 예방을 위한 항생제의 처치를 처방 받고, 환아의 행동 발달적 문제로 인해 물리적 속박의 방법 하에 외래에서 치료되었다. 이 증례를 통해 SMS라는 희귀한 증후군에 관하여 보고하고자 한다.

  • PDF

지뢰탐지를 위한 GPR 시스템의 개발 (GPR Development for Landmine Detection)

  • Sato, Motoyuki;Fujiwara, Jun;Feng, Xuan;Zhou, Zheng-Shu;Kobayashi, Takao
    • 지구물리와물리탐사
    • /
    • 제8권4호
    • /
    • pp.270-279
    • /
    • 2005
  • 일본 문부과학성의 연구 지원하에 지뢰 탐지를 위한 GPR 시스템 개발에 관한 연구를 수행하였다. 2005 년도까지 두 종류의 새로운 지뢰탈지 GPR 시스템 원형의 개발을 완성하였으며 이를 ALIS (Advanced Landmine Imaging System)와 SAR-GPR (Synthetic Aperture Radar-Ground Penetrating Radar)이라고 명명하였다. ALIS는 금속탐지기와 GPR을 결합한 새로운 형태의 휴대용 지뢰탐지 시스템이다. 센서의 위치를 실시간으로 추적하는 시스템을 장착하여 센서에 감지된 신호를 실시간으로 영상화할 수 있도록 하였으며, 센서 위치의 추적은 센서의 손잡이에 장착한 CCD 카메라만을 이용하여 가능하도록 고안하였다. 그리고 GPR과 금속탐지기 신호를 CCD 카메라에 포착된 영상에 중첩하여 동시에 영상화하도록 설계하였기 때문에 매설된 탐지 목적물을 용이하게 그리고 신뢰할 만한 수준으로 탐지하고 구별할 수 있다. 2004년 12월에 아프가니스탄에서 ALIS의 현장 검증 실험을 수행하였으며, 이를 통해 이 연구에서 개발한 시스템을 이용하여 매설된 대인지뢰를 탐지할 수 있을 뿐만 아니라 대인지뢰와 금속 파편의 구분 또한 가능함을 보였다. SAR-GPR은 이동 로보트에 장착한 지뢰탐지 시스템으로 GPR과 금속탐지기 센서로 구성된다. 다수의 송, 수신 안테나로 구성된 안테나 배열을 채택하여 개선된 신호처리 기법의 적용을 가능하며, 이를 통해 좀 더 나은 지하 영상의 획득이 가능하다. SAR-GPR에 합성개구 레이다 알고리듬을 채용함으로써 원하지 않는 클러터(clutter)신호를 억제하고 불균질도가 높은 매질 내부에 매설된 목적물을 영상화할 수 있다. SAR-GPR은 새로이 개발한 휴대용 벡터 네트워크 분석기를 이용한 스텝 주파수 레이다 시스템(stepped frequency radar system)으로 6 개의 Vivaldi 안테나와 3 개의 벡터 네트워크 분석기로 구성된다. SAR-GPR의 크기는 $30cm{\times}30cm{\times}30cm$, 중량은 17 kg 정도이며 소형 무인 차량의 로보트 팔에 장착된다. 이 시스템의 현장 적용 실험은 2005 년 3 월 일본에서 성공적으로 실시된 바 있다.

제품 디자인을 위한 증강현실 기반 정량구조 시뮬레이션 기법에 대한 연구 (A Study on a Quantified Structure Simulation Technique for Product Design Based on Augmented Reality)

  • 이우훈
    • 디자인학연구
    • /
    • 제18권3호
    • /
    • pp.85-94
    • /
    • 2005
  • 최근 대부분의 제품 디자이너들이 3차원 CAD 시스템을 필수적인 디자인 도구로서 활용하고 있고 이를 기반으로 많은 신제품들이 동시공학적 프로세스로 개발되고 있다. 그런데 초심 디자이너들이 3차원 CAD시스템을 사용하며 겪는 어려움 중 하나는 스크린을 통해 모델링한 오브젝트의 실체적 느낌을 정확히 판단하기 어렵다는 것이다. 이러한 '실체성 결여'의 문제는 3차원 CAD시스템에서의 모델링 작업이 가상공간 안에서만 이루어지기 때문에 촉각적 상호작용이 부재하고 현실공간에 대한 맥락정보가 결여되어 있는 것이 그 원인이라고 착 수 있다. 문제해결을 위해 본 연구에서는 증강현실기술을 활용하여 3차원 CAD 모델링 오브젝트를 현실공간에 정합시킴으로서 제품디자인에서 상호작용적인 정량구조 시뮬레이션의 가능성을 탐색하고자 하였다. 본 연구는 우선 증강현실 기반 정량구조 시뮬레이션 시스템을 구축하고 그 속에서 인간이 가상 오브젝트의 크기를 얼마나 정확하게 인지하고 조정할 수 있는지 실험하였다. 실험 결과 상대오차 1.3%이내(상대표준편차 5.3%이내)로서 상당히 정확하고 정밀한 크기 인지와 조정이 가능한 것으로 나타났다. 실험조건에 따라서는 주변참조물이 풍부한 경우 오브젝트에 대한 크기인지가 용이하고 HDM보다는 LCD 패널을 사용할 경우 더욱 정확한 크기 조정이 가능한 것으로 나타났다. 연구를 통해 제안한 증강현실 기반 정량구조 시뮬레이션시스템의 응용가능성을 탐색하기 위해 홈 서비스 로봇의 외관에 대해 사용자의 선호경향을 파악하는데 적용해 보았다. 아직 홈 서비스 로봇에 대한 전형적 이미지가 미비해서인지 외관특성에 대한 실험참가자의 선호경향에는 큰 편차가 보였고 군집분석을 통해 몇 그룹으로 세분화할 수 있었다. 그러나 팔이라는 조형요소의 유무에 따라 민감한 반응을 보인 점과 인체와 같이 신장과 팔길이 사이에 강한 상관성이 존재하는 것은 흥미로운 발견이었다. 프로세스를 제안하고자 한다.0 이용과 복제제한에 관한 주기(terms governing use and reproduction notes), 541 직접적 출처주기(immediate source of acquisition note), 545 행정연혁/개인이력주기(biographical or historical note), 581 출판주기(publication note), 850 소장처(holding institution) 데이터필드의 식별기호를 재구성, 추가하였다.근방법과 컨조인트 분석)의 조화를 이룰 수 있는 이론적 기초가 될 수 있다. 즉, 제품디자인의 결정요인 분석결과는 QFD의 접근방법에, 제품 디자인 파급효과 분석결과는 컨조인트 분석에 각각 보완적 기여를 할 수 있다. 이와 동시에, 실증적 분석결과는 Ettlie(1997)의 디자인 통합(DI) 이론에 대한 실증적 기반을 제공할 수 있다. 마지막으로, 성공적인 디자인 경영(DM)을 위해서는 최고 경영자의 지원뿐만 아니라 부처 간 의사소통의 장애요인을 제거하고 CFT(cross-functional team)를 운영함으로써 동시적 엔지니어링(CE) 및 제품 및 공정 디자인의 개발이 제품 개발의 속도를 가속화하고 디자인 품질을 높이며 시장 성공을 보증할 수 있도록 해야 한다.임과 채팅은 긍정적인 상호관련을 가진 것으로 나타난 반면 전자메일 서비스 이용은 성적 만족과 부정적인 상호관련을 가진 것으로 분석되었다. 이는 대학생들이 지루하게 느끼거나 외로움을 느낄 때 전자메일을 주로 이용하지만 성적 만족을 위해 전자메일을 이용하지 않고 있다는 사실을 보여주는 것이다. (3) 인터넷 이용 이후 다른 미디어와 면대면 커뮤니케이션과의 관계 인터넷을 이용한 후 응답자들의 전통적인 미디어(텔레비전, 라디오, 신문, 잡지, 편지, 전화) 이용이 감소되었으며 친구, 가족, 이성친구와의 면대면 커뮤니케이션 역시 감소된

  • PDF

촌, 관, 척 위치의 맥파 특징 차이 검정에 대한 1례 (An Example of Test on Differences of Pulse Waveform Characteristics at Cun, Guan and Chi)

  • 이전;이유정;전영주;이혜정;유현희;김종열
    • 한국한의학연구원논문집
    • /
    • 제14권2호
    • /
    • pp.107-112
    • /
    • 2008
  • Although the pulse diagnosis position, Guan is apart from Cun or Chi by only $10{\sim}20$ mm at most, traditional medical doctors applies different indent pressures and even they states different pulse images are felt at Cun, Guan and Chi, To support their clinical behaviors, in this study, we tested statistically whether there are differences in pulse waveform measured at these three positions with SphygmoCor system used world widely, A 30 years old female subject without any evidence of cardiovascular diseases was involved in this experiment. Radial pulse waves were recorded at three different positions on left lower arm 10 times at three positions-Cun, Guan and Chi. With ANOVA, we tested whether, among three different positions. there are any differences in 12 parameters of radial pulse waveform and in estimated AIx(Augmentation Index) as an arterial stiffness index extracted from radial pulse waveform. As results, differences in optimal indent pressure h0 were observed at different measuring positions(P<0.001) but not significantly different. And pulse pressure his were found to be different(Chi$22.60{\pm}3.06%,\;18.60{\pm}3.37%\;and\;26.4{\pm}5.02%$ respectively. Consequently. AIx at Gwan seems to be lowest and that at Chi seems to be highest. So. we assert the AIx at Chi is likely to be overestimated. In further studies. we want to examine what make differences in these parameters between measuring positions. And it also seems to be worthy to investigate the relationship between the depth of radial artery and AIx. And, ultimately, we need to determine the best measuring process including measuring position, hold-down pressure, signal quality validation and so on. so to achieve the optimal waveform which represents subject's health condition for both western medicine and traditional medicine.

  • PDF

동적 등가 회로를 이용한 MMC의 시뮬레이션 모델 개발 (Development of Simulation Model for Modular Multilevel Converters Using A Dynamic Equivalent Circuit)

  • 신동철;이동명
    • 한국산학기술학회논문지
    • /
    • 제21권3호
    • /
    • pp.17-23
    • /
    • 2020
  • 본 논문에서는 MMC(Modular Multilevel Converter) 시스템 개발시 필요한 등가 회로를 이용한 MMC 시뮬레이션 모델을 제안한다. MMC는 하프 브릿지 혹은 풀 브릿지 형태의 서브 모듈이 직렬로 수십 개에서 수백 개가 연결된 형태의 전력변환기로, 전압형 HVDC(High Voltage Direct Current)와 같은 고압 송전에 가장 적합한 토폴로지로 선택되어 상용화 되어 있다. MMC의 알고리즘 개발을 위해서는 전체 시스템의 시뮬레이션이 필수적이다. 그러나, 수백 혹은 수천 개의 스위칭 소자를 사용하여 MMC의 시뮬레이션 모델의 구성하거나 시뮬레이션을 수행하는 것은 사실상 불가능하다. 따라서 본 논문에서는 전압 레벨 증가 등의 확장성이 용이하고 MMC 변환기의 전압 전류의 동특성을 등가화하여 구현한 시뮬레이션 모델을 제안한다. 스위칭 신호와 암 전류의 방향으로부터 등가 회로의 전압과 전류식을 연산하고, 이를 Matlab/Simulink를 이용하여 등가 모델화한다. 개발된 모델의 타당성을 보이기 위하여 스위칭의 소자를 이용한 5 레벨의 MMC와 본 논문에서 제안하는 등가 모델 MMC의 시뮬레이션의 결과를 보인다. 두 모델의 전류 파형, 전압 파형 등이 일치함을 보임으로써 개발 모델의 타당성을 보이고자 한다.

뇌졸중(腦卒中) 환자(患者)의 기능평가방법(機能評價方法)에 대(對)한 연구(硏究) (Study on function evaluation tools for stroke patients)

  • 고성규;고창남;조기호;김영석;배형섭;이경섭
    • 대한한의학회지
    • /
    • 제17권1호
    • /
    • pp.48-83
    • /
    • 1996
  • Our conclusions for function evaluation tools of Stroke patients are as follows. 1. Evaluating tools of Activities of Daily Living, Katz Index, Barthel Index, Modified Barthel Index have high validity and reliability because of ease of measuring, high accuracy, consistency, sensitivity and sufficient stastistics, but they mainly measure motor function except sense, mentation, language, and social conception. Therefore cerebrovascular disease and brain injury in trauma patients with lacked acknowledgement and sensation, we are not able to apply these tools. 2. PULSES Profile is a useful scale for measuring the patient's over-all status, upper and lower limb functions, sensory components, excretary functions, and intellectual and emotional adaptabilities. It is recognized as a good, useful tool to evaluate patient's whole function. 3. Motor Assessment Scale was designed to measure the progress of stroke patients. The scale was supplemented with upper arm function items. We believe that the Motor Assessment Scale could be a useful evaluation tool with inter-rater reliability ,test-retest reliability. 4. The existing evaluation tools, Katz Index, Barthel Index, Modified Barthel Index, PULSES Profile, Motor Assessment Scale, mainly measured the rehabilitational motor function of sequela of cerebrovascular patients. On the other hand CNS & INH stroke scale can measure cerebrovascular disease patient's neurologic deficits and over-all stautus, which are recognition ability, speech status, motor function, sensory function, activities of daily living. Those scales have been recognized as useful tools to measure function of cerebrovascular disease patients and have increased in use. 5. Every function evaluation tool was recognized to have some validity and inter-rater, test-retest reliability in items of each evaluation tool and total scores of each evaluation tools, but it is thought that none of these scales have been fully validated and proved reliable. Therefore afterward, the development of a highly reliable rating system may best be accomplished by a careful comparison of several tools, using the same patients and the same observers in order to choose the most reliable items from each. 6. Ideal evaluation tools must have the following conditions; (1) It should show the objective functional statues at the same time. (2) It should be repeated consecutively to know changed function status. (3) It should be easy to observe the treatment program. (4) It should have the same result with another rater to help rater exchange information with treatment team members. (5) It should be practical and simple. (6) The patient should not suffer from the observer.

  • PDF

상악 6전치부의 후방견인시 저항중심의 수직적 위치에 관한 3차원 유한요소법적 연구 (The vertical location of the center of resistance for maxillary six anterior teeth during retraction using three dimensional finite element analysis)

  • 이혜경;정규림
    • 대한치과교정학회지
    • /
    • 제31권4호
    • /
    • pp.425-438
    • /
    • 2001
  • 이 연구는 3차원 유한요소법을 이용하여 상악 6전치부에 피질골 절단술을 시행한 경우와 시행하지 않은 경우에서 상악 6전치부를 하나의 단위로 하여 다양한 후방견인력을 가하였을 때 상악 6전치의 초기 치아이동을 통하여 저항중심의 수직적 위치를 계측, 비교하고 저항중심의 변화양상을 관찰하며, 힘의 크기변화에 따른 저항중심의 위치변화양상을 분석하기 위하여 시행되었다. 상악 6전치와 치주인대 및 치조골의 3차원 유한요소모델을 제작한 후, 상악 6전치부에 부착된 설측장치와 이 장치가 부착된 치아군을 한 개의 견고한 연결체로 가정하였다. 유한요소모델에서 사용된 전체요소의 수는 14,584개, 전체 절점의 수는 17,292 개였고, 힘 체계의 분석을 위해 미국 Swanson Analysis System사의 범용 유한요소 프로그램 인 ANSYS(Ver. 5.5A)를 사용하였다. 저항중심은 힘이 가해질 때 치아가 평행 이동될 수 있는 힘의 적용부위라 정의하고, 설측 장치에서 연장된 Extension arm의 7개의 Level에 편측당 각각 200 gm, 250 gm, 300 gm, 350 gm의 설측 후방견인력을 가하였을 때 치아의 절단연과 치근첨에서의 변위를 읽어 평행이동이 일어나는 위치를 복원법으로 계산하여 저항중심의 위치를 계측, 분석하여 다음과 같은 결과를 얻었다. 1. 상악 6전치부의 초기치아이동에서 저항중심의 수직적 위치는 Level 4와 Level 5사이, 즉 치경부에서 치근단 쪽으로 6.76 mm, $44.32\%$ 떨어진 거리에 위치하였다. 2. 피질골 절단술 시행후, 상악 6전치부의 후방 견인시 저항중심의 수직적위치는 Level 4와 Level 5사이, 즉 치경부에서 치근단 쪽으로 7.09 mm, $46.38\%$ 떨어진 거리에 위치하였다. 3. 후방견인력의 크기가 커짐에 따라 치아의 변위량은 커졌으나, 피질골 절단술 시행 유무에 관계없이 후방견인력의 크기변화는 저항중심의 수직적 위치에 별다른 영향을 미치지 않았다. 4. 피질골 절단술 시행시에 저항 중심의 수직적 위치는 치근단 쪽으로 이동하였고, 그 변위량은 피질골 절단술 시행 시가 컸다. 이상의 결과로 볼 때 상악 6전치부 후방견인시 저항중심의 수직적 위치는 치경부에서 치근단 쪽으로 치근길이의 $44.32\%$ 떨어진 거리에 위치하였고, 피질골 절단술 시행시에 저항중심의 수직적 위치는 치경부에서 치근단 쪽으로 치근 길이의 $46.38\%$ 떨어진 거리에 위치하여 피질골 절단술 시행하지 않은 경우보다 치근단 쪽으로 이동되었으며, 후방견인력의 크기 변화에 따라 저항 중심의 수직적 위치는 변하지 않았다.

  • PDF