• 제목/요약/키워드: Hand-Held Device

검색결과 61건 처리시간 0.029초

진보된 정보기술시스템을 창조하기 위한 진화모델의 이론적 구축 및 실제 응용 연구;mobile device를 기준으로 (The theoretical construction and practical application of Evolution Model for creating the advanced information-technical system;based on mobile device)

  • 김성철;신민수
    • 한국IT서비스학회:학술대회논문집
    • /
    • 한국IT서비스학회 2006년도 추계학술대회
    • /
    • pp.593-599
    • /
    • 2006
  • Including technical device and general information system, the information-technical(IT) system is defined as the technical system for acquiring, processing, storing and transferring information to a person. This paper presents Knowledge-based Heuristic Evolution Model for creating the advanced information-technical system. This Evolution Model is derived from the historical review on definition of evolution, the research on the architecture of the general IT system, history of IT system, technology innovation theory and multi-case study research. The evolution model is applicable to the conceptual creation of the advanced product in R&D organization requiring development methodologies like rapid-prototyping to develop next generation product. For the detailed theoretical construction and practical application of Evolution Model, the case study research based on action research is performed. the object of the case study is mobile device, especially mobile hand-held phone. Thus, we obtain the Evolution Model for creating the advanced information-technical system.

  • PDF

휴대 단말기용 타원곡선 암호 프로세서의 설계 (Design of a Elliptic Curve Crypto-Processor for Hand-Held Devices)

  • 이완복;김정태
    • 한국정보통신학회논문지
    • /
    • 제11권4호
    • /
    • pp.728-736
    • /
    • 2007
  • 최근 인터넷 및 유무선 통신 인프라가 발전함에 따라, 개인 휴대용 단말기나 스마트 카드 등의 다양한 방면에서 개인 정보보호를 위해 고비도의 암호 시스템이 요구되고 있다. 본 논문에서는 연산력이 떨어지는 무선통신용 단말이나 내장형 시스템에서 고비도의 암호 연산력을 제공할 수 있는 타원곡선형 암호 하드웨어의 설계에 대해 소개한다. 효율적인 암호 연산기를 제작하기 위해 먼저 타원곡선 암호 시스템의 핵심 연산 계층도를 분석 해보고, 직렬 셀 곱셈기와 확장유클리드 알고리즘을 수정하여 유한체 나눗셈기를 적용하여 제작하였다. 제작된 암호 시스템은 시뮬레이션 결과 올바른 동작을 보임을 확인할 수 있었으며, 초당 수천회의 서명이 가능한 수준이었다.

CD-RW Drive의 낙하충격 손상평가 (Damage Evaluation of CD-RW Drive by Drop Test and Simulation)

  • 우재철;윤기원;석기영;김헌영;김상범
    • 대한기계학회논문집A
    • /
    • 제29권1호
    • /
    • pp.81-87
    • /
    • 2005
  • A fracture of hand held device, such as radio, TV and CD-RW drive, mainly occurs due to drop situation. For CD-RW drive, the need of high reading/writing speed in conjunction with low price accelerates the fracture of the device. Computer simulation can reduce the period of development and enhance impact characteristic of device. In this study, the detailed finite element model of CD-RW drive was developed to predict the damage under drop conditions. Material property for shock absorbing damper was obtained from tensile test of raw material. A MOONEY-RIVLIN type rubber in LS-DYNA was used as the material model of damper. To assess the reliability of the developed model, drop test at 200G-2msec and 150G-10msec condition was conducted and acceleration at pick-up was compared.

Characterizing Viscoelastic Property of Soft Tissue Over the Hip as a Risk Factor of Pressure Ulcer

  • Lim, Kitaek;Kim, Seung-su;Choi, Woochol Joseph
    • 한국전문물리치료학회지
    • /
    • 제28권1호
    • /
    • pp.72-76
    • /
    • 2021
  • Background: A pressure ulcer is common in soft tissue over the greater trochanter (GT) in side-lying position, and sustained tissue deformation induced by the prolonged external force is a primary cause, which can be discussed with soft tissues' viscoelastic properties (i.e., stress relaxation, creep response). Objects: Using an automated hand-held indentation device, we measured the viscoelastic properties of soft tissue over the hip area, in order to examine how the properties are affected by site with respect to the GT. Methods: Twenty participants (15 males and 5 females) who aged from 21 to 32 were participated. An automated hand-held indentation device was used to measure the stress relaxation time and creep response. Trials were acquired for three different locations with respect to the GT (i.e., right over the GT, 6 cm anterior or posterior to the GT). For each location, five trials were acquired and averaged for data analyses. Results: Soft tissues' stress relaxation time and creep response were associated with site (F = 23.98, p < 0.005; F = 24.09, p < 0.005; respectively). The stress relaxation time was greatest at posterior gluteal region (19.22 ± 2.49 ms), and followed by anterior region (15.39 ± 2.47 ms) and right over the GT (14.40 ± 3.18 ms). Similarly, creep response was greatest at posterior gluteal region (1.16 ± 0.14), and followed by anterior region (0.95 ± 0.14) and right over the GT (0.89 ± 0.18). Conclusion: Our results showed that the stress relaxation and creep were greatest at the posterior gluteal region and least at right over the GT, indicating that the gluteal soft tissue is more protective to the prolonged external force, when compared to the trochanteric soft tissue. The results suggest that a risk of pressure ulcer over the GT may decrease with slightly posteriorly rotated side-lying position.

Design of Fast Elliptic Curve Crypto module for Mobile Hand Communication

  • Kim, Jung-Tae
    • Journal of information and communication convergence engineering
    • /
    • 제6권2호
    • /
    • pp.177-181
    • /
    • 2008
  • The more improved the Internet and the information technology, the stronger cryptographic system is required which can satisfy the information security on the platform of personal hand-held devices or smart card system. This paper introduces a case study of designing an elliptic curve cryptographic processor of a high performance that can be suitably used in a wireless communicating device or in an embedded system. To design an efficient cryptographic system, we first analyzed the operation hierarchy of the elliptic curve cryptographic system and then implemented the system by adopting a serial cell multiplier and modified Euclid divider. Simulation result shows that the system was correctly designed and it can compute thousands of operations per a second. The operating frequency used in simulation is about 66MHz and gate counts are approximately 229,284.

TangibleScreen 객체중심 프로젝션을 통한 상호작용성 향상 (TangibleScreen : Enhancing Interactivity through Object-centric Projection)

  • 신선형;김정현
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제9권1호
    • /
    • pp.19-27
    • /
    • 2003
  • Most interaction schemes in virtual environment are indirect in one way or another. ln particular, without a haptic device (which introduces its own problems due to its cumbersomeness), users must rely on visual (or/and aural) feedback, and can not directly appreciate the 3Dness of the interaction object even with stereoscopy. This causes a drop in object presence because people are used to, for instance, observing objects in one's hand, rotating and manipulating them with physical contact. To alleviate this problem, this paper proposes a hand-held cubic screen, named TangibleScreen, on which the appearance of the target interaction object is projected. We choose the Relief Texture Mapping as the rendering method to correctly generate the viewer dependent textures to be projected on the non-planar surfaces of the TangibleScreen.

  • PDF

WiFi 무선 네트워크 기반의 제어 시스템 (WiFi Wireless Network based Control System)

  • 정의훈;임중권
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 춘계학술대회
    • /
    • pp.575-577
    • /
    • 2013
  • WiFi 무선 통신 기능을 갖춘 스마트폰을 비롯한 각종 가전 도구들이 시장에서 일반화되면서 WiFi AP(access point)를 통해서 무선 랜을 구축하고자 하는 수요가 증가하고 있다. 또한 최근 들어 AP의 가격이 저렴화 되면서 AP를 이용하여 주차 위치를 알려주는 등 다양한 서비스를 제공하려는 시도들이 생겨나고 있다. 본 논문에서는 제어 기능과 위치 정보 제공 기능을 갖춘 AP를 기반으로 하는 제어 시스템을 개발한다. 제안하는 제어 시스템은 외부 장치 제어 기능과 스마트폰 위치 확인 기능이 있는 AP와 AP들을 제어하고 수집된 정보들을 처리하는 AP 서버, 사용자들에게 서비스를 제공하기 위한 스마트폰용 응용 프로그램으로 구성된다.

  • PDF

PXA255기반 의료정보 고속 전송 시스템에 관한 연구 (A Study on High Speed Transmission System of Medical Information Based on PXA255)

  • 한영재;유호준;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.386-389
    • /
    • 2006
  • 미래 유비쿼터스 환경에 적합한 플랫폼은 모바일이면서 대용량 데이터를 자유롭게 송수신할 것이다. 그런 가운데 의료분야에서는 센서와 멀티미디어 기술의 발달에 발맞춰 개인이 휴대할 수 있는 휴대용이나 재택형 의료기기가 더욱 발전될 것이다. 그러한 다양한 의료기기 정보를 손쉽게 교환하고 전송하는 헬스케어용 단말기 또한 발전될 것이다. 이에 본 논문에서는 현재 모바일기기에 강력한 프로세서인 PXA255를 기반으로 이동성과 속도를 보장하는 WLAN을 연결하여 모바일 플랫폼에서의 의료 정보 전송을 통하여 효율적인 서비스를 위한 시스템을 제공하는데 중점을 두었다.

  • PDF

로봇 지원 원격 초음파 영상진단을 위한 마스터-슬레이브 시스템의 개발 (Development of Master-slave System for Robot-assisted Remote Ultrasound Diagnosis)

  • 서준호;조장호;권오원
    • 로봇학회논문지
    • /
    • 제12권4호
    • /
    • pp.395-401
    • /
    • 2017
  • In this paper, we introduce a robot-assisted medical diagnostic system that enables remote ultrasound (US) imaging to be applied to the conventional telemedicine, which has been possible only with interviewing or a visual exam. In particular, a master-slave robot system is developed that ultrasonic diagnosis specialist can control the position and orientation of US probe in the remote place. The slave robot is designed to be compact, lightweight, and hand-held so that it can easily transfer to the remote healthcare center. Moreover, 6-degree-of-freedom (DOF) probe motion is possible by the robot design based on Stewart platform. The master device is also based on a similar structure of the slave robot. To connect master and slave system in the wide area network (WAN) environment, a hardware CODEC was developed. In this paper, we introduce the detail of each component and the results of the recent experiments conducted in the remote sites by the developed robotic ultrasound imaging system.