• Title/Summary/Keyword: Hand force measurement

Search Result 54, Processing Time 0.025 seconds

Structural, optical, and electrical properties on Cu(In,Ga)$Se_2$ thin-films with Cu-defects and In/(In+Ga) ratio (Cu(In,Ga)$Se_2$ 박막의 Cu 결함 및 In, Ga 비율의 변화에 따른 구조적, 광학적, 전기적 특성 연구)

  • Jeong, A.R.;Kim, G.Y.;Jo, W.;Jo, H.J.;Kim, D.H.;Sung, S.J.;Kang, J.K.;Lee, D.H.;Nam, D.H.;Cheong, H.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.47.1-47.1
    • /
    • 2011
  • We report on a direct measurement of two-dimensional chemical and electrical distribution on the surface of photovoltaic Cu(In,Ga)$Se_2$ thin-films using a nano-scale spectroscopic and electrical characterization, respectively. The Raman measurement reveals non-uniformed surface phonon vibration which comes from different compositional distribution and defects in the nature of polycrystalline thin-films. On the other hand, potential analysis by scanning Kelvin probe force microscopy shows a higher surface potential or a small work function on grain boundaries of the thin-films than on the grain surfaces. This demonstrates the grain boundary is positively charged and local built-in potential exist on grain boundary, which improve electron-hole separation on grain boundary. Local electrical transport measurements with scanning probe microscopy on the thin-films indicates that as external bias is increases, local current is started to flow from grain boundary and saturated over 0.3 V external bias. This accounts for carrier behavior in the vicinity of grain boundary with regard to defect states. We suggest that electron-hole separation at the grain boundary as well as chemical and electrical distribution of polycrystalline Cu(In,Ga)$Se_2$ thin-films.

  • PDF

Comparative Analysis of Two Pedobarography Systems (두 족저압 측정장비의 비교 분석)

  • Ho Won Kang;Soomin Pyeun;Dae-Yoo Kim;Yun Jae Cho;Min Gyu Kyung;Dong Yeon Lee
    • Journal of Korean Foot and Ankle Society
    • /
    • v.28 no.1
    • /
    • pp.21-26
    • /
    • 2024
  • Purpose: Foot pressure measurement devices are used widely in clinical settings for plantar pressure assessments. Despite the availability of various devices, studies evaluating the inter-device reliability are limited. This study compared plantar pressure measurements obtained from HR Mat (Tekscan Inc.) and EMED-n50 (Novel GmbH). Materials and Methods: The study involved 38 healthy male volunteers. The participants were categorized into two groups based on the Meary's angle in standing foot lateral radiographs: those with normal feet (angles ranging from -4° to 4°) and those with mild flatfeet (angles from -8° to -15°). The static and dynamic plantar pressures of the participants were measured using HR Mat and EMED-n50. The reliability of the contact area and mean force was assessed using the interclass correlation coefficient (ICC). Furthermore, the differences in measurements between the two devices were examined, considering the presence of mild flatfoot. Results: The ICC values for the contact area and mean force ranged from 0.703 to 0.947, indicating good-to-excellent reliability across all areas. EMED-n50 tended to record higher contact areas than HR Mat. The mean force was significantly higher in the forefoot region when measured with EMED-n50, whereas, in the hindfoot region, this difference was observed only during static measurements with HR Mat. Participants with mild flatfeet exhibited significantly higher contact areas in the midfoot region for both devices, with no consistent differences in the other parameters. Conclusion: The contact area and mean force measurements of the HR Mat and EMED-n50 showed high reliability. On the other hand, EMED-n50 tended to record higher contact areas than HR Mat. In cases of mild flatfoot, an increase in contact area within the midfoot region was observed, but no consistent impact on the differences between the two devices was evident.

Study of the re-osseointegration of implant fixture after mechanical unscrewing (임플란트 고정체의 의원성 동요 후 골 유착 반응에 관한 연구)

  • Jang, Ji-Hoon;Cho, Jin-Hyun;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.209-214
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate whether the re-osseointegration of the implants that had mechanical unscrewing possibly occurred or not. Furthermore, if it happened, the degree of re-osseointegration was evaluated by comparing with previous osseointegration. Materials and methods: The smooth implant (commercial pure titanium 99%) specimens, whose diameter and length was 3.75 mm, 4 mm, respectively were produced. Two implants were inserted into each tibia of 7 New Zealand female white rabbits weighing at least 3.0 kg. The torque removal force for each implant after 6 weeks of implants placement was measured and included in group I. The torque removal forces were assessed after the fixtures were re-screwed to original position and the subjects were allowed to have 4 more weeks for healing and included in group II. One rabbit was sacrificed after first measurement and produced 4 slide specimens in group I, and two rabbits were sacrificed after 2nd measurement, 7 slide specimens, in group II for histomorphologic investigations. All slide specimens were assessed based on the proportion of BIC (bone-implant contact) as well as CBa (Bone area in the cortical passage) value produced by counting the screw threads embedded in the compact bones under the optical microscopic analysis (${\times}20$). Statistical analysis was conducted to evaluate the torque removal force, BIC and CBa between group I and II. Results: As for the torque removal force, the result was $10.8{\pm}3.6$ Ncm for group I and $20.2{\pm}9.7$ Ncm for group II. Furthermore, the torque removal force of group II increased by 98.1% in average compared to group I (P<.05). On the other hand, histomorphologic analysis displayed that there was no statistical significance in BIC and CBa values between group I and the group II (P>.05), and RT/BIC and RT/CBa between group I and group II were statistically significant (P<.05). Conclusion: It is possible to obtain more substantial re-osseointegration within shorter periods than the period needed for the initial osseointegration in case of iatrogenically unscrewed implants.

Trajectory Estimation of Center of Plantar Foot Pressure Using Gaussian Process Regression (가우시안 프로세스 회귀를 이용한 족저압 중심 궤적 추정)

  • Choi, Yuna;Lee, Daehun;Choi, Youngjin
    • The Journal of Korea Robotics Society
    • /
    • v.17 no.3
    • /
    • pp.296-302
    • /
    • 2022
  • This paper proposes a center of plantar foot pressure (CoP) trajectory estimation method based on Gaussian process regression, with the aim to show robust results regardless of the regions and numbers of FSRs of the insole sensor. This method can bring an interpolation between the measurement points inside the wearable insole sensor, and two experiments are conducted for performance evaluation. For this purpose, the input data used in the experiment are generated in three types (13 FSRs, 8 FSRs, 5 FSRs) according to the regions and numbers of FSRs. First, the estimation results of the CoP trajectory are compared using Gaussian process regression and weighted mean. As a result of each method, the estimation results of the two methods were similar in the case of 13 FSRs data. On the other hand, in the case of the 8 and 5 FSRs data, the weighted mean varies depending on the regions and numbers of FSRs, but the estimation results of Gaussian process regression showed similar results in spite of reducing the regions and numbers. Second, the estimation results of the CoP trajectory based on Gaussian process regression during several gait cycles are analyzed. In five gait cycles, the previous cycle and the current estimation results are compared, and it was confirmed that similar trajectories appeared in all. In this way, the method of estimating the CoP trajectory based on Gaussian process regression showed robust results, and stability was confirmed by yielding similar results in several gait cycles.

Evaluation of Muscle Load and Fatigue According to the Shape of Severe Dementia Patients' Clothing (중증 치매환자복 형태에 따른 근육 부하 및 피로도 평가)

  • Kwang Ae Park;Chung Eun Yang;Hayoung Jung
    • Fashion & Textile Research Journal
    • /
    • v.25 no.2
    • /
    • pp.185-198
    • /
    • 2023
  • The purpose of this study is to obtain information necessary for the development of patient clothes that can reduce physical fatigue of caregivers by quantitatively measuring the muscle load and fatigue. The patient clothes used in this study can be broken down into three types: A type (back center zipper open suit), B type (top-to bottom separated patient clothes), and C type (front zipper open suit). The EMG measurement sites are as follows: hand muscle (brachioradialis), upper arm (biceps, triceps), shoulder (anterior deltoid, medial deltoid, posterior deltoid, upper trapezius), and waist (erector spinae); additionally, the EMG signals were measured. Through this experiment, muscle load, muscle energy consumption, and muscle fatigue generation tendency were analyzed. The results of the study revealed that the C type patient clothes required the most strength in the muscles of the shoulders, upper arms, hands, and back when being put on and taken off compared to other patient clothes. The A type clothes required a relatively large force in opening the zipper. In terms of muscle energy consumption, B type generally called for more strength when it came to the zip-up and putarmsup motions. With regard to the cover the body and put legs/hips up motions, C type used the highest amount of muscle energy, whereas A type used relatively little energy. In terms of the occurrence of muscle fatigue during the putting on and taking off of the patient's clothing, there was a difference in the area and degree of muscle fatigue in the A, B, and C types, and there was also a tendency for muscle fatigue to occur when performing repetitive movements.

Temperature dependence of Heteroeptaxial $Y_2O_3$ films grown on Si by ionized cluster beam deposition

  • Cho, M.-H.;Ko, D.-H.;Whangbo, S.W.;Kim, H.B.;Jeong, K.H.;Whang, C.N.;Choi, S.C.;Cho, S.J.
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.s1
    • /
    • pp.57-77
    • /
    • 1998
  • Heteroepitaxial $Y_2O_3$ films were grown on a Si(111) substrate by ionized cluster beam deposition(ICBD) in ultra high vacuum, and its qualities such as crystllitnity, film stress, and morphological characteristics were investigated using the various measurement methods. The crystallinity was investigated by x-ray diffraction (XRD) and reflection high energy electron diffraction (RHEED). Interface crystallinity was also examined by Rutherford backscattering spectroscopy(RBS) channeling, transmission electron microscopy(TEM). The stress of the films was measured by RBS channeling and XRD. Surface and interface morphological characteristics were investigated by atomic force microscopy (AFM) and x-ray scattering method. Comparing the interface with the surface characteristics, we can conclude that many defects at the interface region were generated by interface reaction between the yttrium metal and SiO2 layer and by ion beam characteristic such as shallow implantation, so that they influenced the film qualities. The film quality was dominantly depended on the characteristic temperature range. In the temperature range from $500^{\circ}C$ to $600^{\circ}C$, the crystallinity was mainly improved and the surface roughness was drastically decreased. On the other hand, in the temperature range from $600^{\circ}C$ to $700^{\circ}C$, the compressive stress and film density were dominantly increased, and the island size was more decreased. Also the surface morphological shape was transformed from elliptical shape to triangular. The film stress existed dominantly at the interface region due to the defects generation.

  • PDF

PREPARATION OF AMORPHOUS CARBON NITRIDE FILMS AND DLC FILMS BY SHIELDED ARC ION PLATING AND THEIR TRIBOLOGICAL PROPERTIES

  • Takai, Osamu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.3-4
    • /
    • 2000
  • Many researchers are interested in the synthesis and characterization of carbon nitride and diamond-like carbon (DLq because they show excellent mechanical properties such as low friction and high wear resistance and excellent electrical properties such as controllable electical resistivity and good field electron emission. We have deposited amorphous carbon nitride (a-C:N) thin films and DLC thin films by shielded arc ion plating (SAIP) and evaluated the structural and tribological properties. The application of appropriate negative bias on substrates is effective to increase the film hardness and wear resistance. This paper reports on the deposition and tribological OLC films in relation to the substrate bias voltage (Vs). films are compared with those of the OLC films. A high purity sintered graphite target was mounted on a cathode as a carbon source. Nitrogen or argon was introduced into a deposition chamber through each mass flow controller. After the initiation of an arc plasma at 60 A and 1 Pa, the target surface was heated and evaporated by the plasma. Carbon atoms and clusters evaporated from the target were ionized partially and reacted with activated nitrogen species, and a carbon nitride film was deposited onto a Si (100) substrate when we used nitrogen as a reactant gas. The surface of the growing film also reacted with activated nitrogen species. Carbon macropartic1es (0.1 -100 maicro-m) evaporated from the target at the same time were not ionized and did not react fully with nitrogen species. These macroparticles interfered with the formation of the carbon nitride film. Therefore we set a shielding plate made of stainless steel between the target and the substrate to trap the macropartic1es. This shielding method is very effective to prepare smooth a-CN films. We, therefore, call this method "shielded arc ion plating (SAIP)". For the deposition of DLC films we used argon instead of nitrogen. Films of about 150 nm in thickness were deposited onto Si substrates. Their structures, chemical compositions and chemical bonding states were analyzed by using X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy and infrared spectroscopy. Hardness of the films was measured with a nanointender interfaced with an atomic force microscope (AFM). A Berkovich-type diamond tip whose radius was less than 100 nm was used for the measurement. A force-displacement curve of each film was measured at a peak load force of 250 maicro-N. Load, hold and unload times for each indentation were 2.5, 0 and 2.5 s, respectively. Hardness of each film was determined from five force-displacement curves. Wear resistance of the films was analyzed as follows. First, each film surface was scanned with the diamond tip at a constant load force of 20 maicro-N. The tip scanning was repeated 30 times in a 1 urn-square region with 512 lines at a scanning rate of 2 um/ s. After this tip-scanning, the film surface was observed in the AFM mode at a constant force of 5 maicro-N with the same Berkovich-type tip. The hardness of a-CN films was less dependent on Vs. The hardness of the film deposited at Vs=O V in a nitrogen plasma was about 10 GPa and almost similar to that of Si. It slightly increased to 12 - 15 GPa when a bias voltage of -100 - -500 V was applied to the substrate with showing its maximum at Vs=-300 V. The film deposited at Vs=O V was least wear resistant which was consistent with its lowest hardness. The biased films became more wear resistant. Particularly the film deposited at Vs=-300 V showed remarkable wear resistance. Its wear depth was too shallow to be measured with AFM. On the other hand, the DLC film, deposited at Vs=-l00 V in an argon plasma, whose hardness was 35 GPa was obviously worn under the same wear test conditions. The a-C:N films show higher wear resistance than DLC films and are useful for wear resistant coatings on various mechanical and electronic parts.nic parts.

  • PDF

The effect of copper alloy scaler tip on the surface roughness of dental implant and restorative materials (구리 합금 초음파 스케일러 팁이 치과 임플란트 및 수복 재료 표면에 미치는 영향)

  • Lee, Ah-Reum;Chung, Chung-Hoon;Jung, Gyu-Un;Pang, Eun-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • Purpose: This study is designed to investigate the various impacts of different types of scaler tips such as cooper alloy base tip and the others on the surface roughness of teeth and implant by the method which is currently in clinical use. Materials and methods: Four different types of disc shaped porcelain, titanium, zirconia, and Type III gold alloy dental materials sized 15 mm diameter, 1.5 mm thickness were used for the experiment. Plastic hand curette (Group PS), cooper alloy new tip (Group IS), and stainless steel tip (Group SS) were used as testing appliances. A total of 64 specimens were used for this study; Four specimens for each material and appliance group. Surface roughness was formed with 15 degree angle in ultrasonic scaler tip and with 45 degree angle in hand curette of instrument tip and the specimen surface with 5 mm long, one horizontal-reciprocating motion per second for 30 seconds by 40 g force. To survey the surface roughness of each specimen, a field emission scanning electron microscope, an atomic force microscope, and a surface profiler were used. (Ra, ${\mu}m$). Results: According to SEM, most increased surface roughness was observed in SS group while IS groups had minimal roughness change. Measurement by atomic force microscope presented that the surface roughness of SS group was significantly greater than those of PS, IS and control groups in the type III gold alloy group (P<.05). IS group showed lesser surface roughness changes compared to SS group in porcelain and gold alloy group (P<.05). According to surface profiler, surface roughness of SS group showed greater than those of PS, IS and control groups and IS group showed lesser than those of SS group in all specimen groups. Type III gold alloy group had large changes on surface roughness than those of porcelain, titanium, zirconia (P<.05). Conclusion: The result of this study showed that newly developed copper alloy scaler tip can cause minimal roughness impacts on the surface of implant and dental materials; therefore this may be a useful alternative for prophylaxis of implant and restored teeth.

The Influence of the Direction of Applied Load(Compression and Uplift) and the Diameter of the Pile on the Pile Bearing Capacity (하중 작용 방향(압축과 인발)과 말뚝의 직경이 말뚝 지지력에 미치는 영향)

  • 이명환;윤성진
    • Geotechnical Engineering
    • /
    • v.7 no.3
    • /
    • pp.51-64
    • /
    • 1991
  • The reliable estimation of pile bearing capacity is essential for the improvement of the re- liability and the cost-effectiveness of the design. There have been numerous pile bearing capacity prediction methods proposed up to now, however, execpt for the estimation made from the result of the pile loading test, not one method is appropriate for the reliable prediction. Due to the considerable time and expenses required to carry out the pile loading test, the test has seldom been utilized. The development of Simple Pile Loading Test(SPLT) which utilizes the pile skin friction as the required reaction force to cause the pile tip settlement, provides a solution to perform more pile loading tests and consequently a more economical pile design is possible. The separate measurement of skin friction and tip resistance during the course of performing SPLT provides a better understanding of the pile behavior than the result of the conventional pile loading test where only the total resistance is measured. On the other hand, there are some points to be clarified in order to apply the test results of SPLT to practical problem. They are the direction of the applied load to mobilize the skin friction and the use of reduced sized sliding core. In this research, both the SPLT and the conventional pile loading test on 406mm diameter steel pipe pile have been performed. From the result, it would be safe to use the measured SPLT skin friction value directly in the design, since the value is somewhat lower than the value measured in the conventional test. It is further assumed that the tip resistance value of the reduced sized sliding core should properly be analysed by taking the incluonce of scale effect into consideration.

  • PDF

Comparisons of Foot Pressure Patterns between Experienced Skiers and Intermediate Skiers during Alpine Skiing (알파인 스킹 시 상급 스키어와 중급 스키어 간의 족저압력 패턴 비교)

  • Kim, Joo-Nyeon;Yoo, Si-Hyun;Ha, Sung-He;Kim, Jin-Hae;Ryu, Ji-Seon;Park, Sang-Kyoon;Yoon, Suk-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.1
    • /
    • pp.19-26
    • /
    • 2014
  • This study investigated foot pressure patterns between experienced skiers and intermediate skiers during alpine skiing. Five experienced skiers and five intermediate skiers participated in this study. Foot pressure measurement system was used to measure vertical ground reaction force (vGRF) and contact area under the six plantar regions. Each participant was asked to perform basic parallel turns and carved turns on a $18^{\circ}$ groomed slope. Each right turn was divided into the initiation phase, the steering phase 1 and 2. For the initiation phase of the basic parallel turns, significantly greater contact area was found on the LRF and RRF of the intermediate skiers (p<.05) and significantly greater vGRF was found on the LRF of the intermediate skiers (p<.05). Also significantly greater vGRF and contact area were found on the LRF and RRF of the intermediate skiers at the steering phase 1 (p<.05) and on the LRF of the intermediate skiers at the steering phase 2 (p<.05). For the carved turns, significantly greater vGRF and contact area were found on the LRF and RRF of the intermediate skiers at all three phase (p<.05). On the other hand, significantly greater vGRF was found on the RFF of the experienced skiers at the steering phase 1 (p<.05). Also significantly greater vGRF and contact area were found on the RMF of the experienced skiers at the steering phase 2 (p<.05). In order to increase performance, we suggest that the intermediate skiers should be unweighted at the initiation phase and shift the body weight to the forefoot of the outer foot at the steering phase 1. Also, the outer ski should be loaded more than the both skis at the steering phase 1 and 2.