• 제목/요약/키워드: Hand elevation test

검색결과 16건 처리시간 0.021초

Comparative Study of Electromyography and Hand Elevation Test in Carpal Tunnel Syndrome

  • Yun, Tae Kyoung;Kim, Deok-Yeol;Ahn, Duck Sun
    • Archives of Reconstructive Microsurgery
    • /
    • 제24권1호
    • /
    • pp.13-15
    • /
    • 2015
  • Purpose: Since the hand elevation test was first introduced by Ahn in 2001, it has been one of most performing provocative test for diagnosing carpal tunnel syndrome. Although many studies have been published on the hand elevation test, there are no study that can explain why false-negative results of hand elevation test appears in carpal tunnel syndrome patients diagnosed by electromyography (EMG) findings. Therefore we searched out whether hand elevation test is related with EMG severity. Materials and Methods: We made a retrospective study of 654 bilateral carpal tunnel syndrome patients. Among them 134 were studied which had different hand elevation test results on each hands. The paired samples t-test was used to compare the EMG severity of each group. The relationships between hand elevation test and EMG severity were examined using Pearson-product correlations. Comparing whether the frequency of false negative hand elevation were different between both hands, and whether the severity of EMG depends on which side of hand is, was evaluated with Mann-Whitney U-test. Results: Severity of EMG in positive group was moderate to severe on average, whereas mild to moderate on negative group, with significant difference statistically (p<0.001). Correlation between the hand elevation test results and EMG severity also showed significance statistically (p<0.001). Conclusion: Mild severity of EMG was found out to be the factor affecting the false results. However, EMG severity and hand elevation test shows a meaningful correlation, supporting the value of hand elevation test.

The Diagnostic Assessment of Hand Elevation Test in Carpal Tunnel Syndrome

  • Ma, HyunJin;Kim, Insoo
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권5호
    • /
    • pp.472-475
    • /
    • 2012
  • Objective : The aim of this study is to establish the value of hand elevation test as a reproducible provocative test for the diagnosis of carpal tunnel syndrome (CTS). Methods : We had a prospective study of 45 hands of 38 patients diagnosed with CTS between April 2005 and February 2009. The diagnosis of CTS was based on the American Academy of Neurology clinical diagnostic criteria. Experimental and control group patients underwent Tinel's test, Phalen's test, carpal compression test and hand elevation test as provocative tests for CTS. Results : We used chi-square analysis to compare Tinel's test and Phalen's test, carpal compression test with hand elevation test. The sensitivity and specificity of the hand elevation test is 86.7% and 88.9% each. Tinel's test had 82.2% sensitivity and 88.9% specificity. Phalen's test had 84.4% sensitivity and 86.7% specificity. Carpal compression test had 84.4% sensitivity 82.2% specificity. Comparisons of sensitivity and specificity between hand elevation test and Tinel's test, Phalen's test, and carpal compression test had no statistically significant differences. To compare the diagnostic accuracies of four tests, the area under the non-parametric receiver operating character curve was applied. Conclusion : The hand elevation test has higher sensitivity and specificity than Tinel's test, Phalen's test, and carpal compression test. Chi-square statistical analysis confirms the hand elevation test is not ineffective campared with Tinel's test, Phalen's test, and carpal compression test.

근골격계 질환 예방을 위한 견인곡사포 고각조정 방법의 개선 (Improvement of Firing Elevation Driving Method for Towed Howitzer to Prevent Musculoskeletal Problems)

  • 박성호
    • 대한산업공학회지
    • /
    • 제42권2호
    • /
    • pp.122-128
    • /
    • 2016
  • The purpose of this study is to improve the firing elevation driving method for towed howitzer to prevent the musculoskeletal disorders. To adjust the firing elevation, it is required to rotate the hand wheel and this work has been done manually in the firing test range as the same method as field artillery troops. In the firing test range, the motor-driven firing elevation adjustment device was developed to improve the working efficiency and safety. These were compared by using posture classification scheme of RULA and REBA. It was measured elapsed time to investigate the improved operational efficiency. The optimal posture of upper body to operate the hand wheel for field artillery troops was proposed.

DCM 부상토의 융기 특성에 대한 실험적 연구 (An Experimental Study on the Heave Characteristics of DCM Heaving Soil)

  • 박언상;박승도
    • 한국지반환경공학회 논문집
    • /
    • 제24권2호
    • /
    • pp.5-12
    • /
    • 2023
  • 본 연구에서는 DCM 실내 시험시공을 통해 실제 현장에서의 부상토 발생량과 부상토의 융기 특성을 정량적으로 분석하였다. 즉, DCM 공법 일련의 시공과정을 실제 현장과 근사하게 대형토조에서 재현함으로써 부상토의 발생량을 예측하고 부상토의 융기고, 확산범위, 확산각, 융기량 등의 융기 특성을 평가하였다. 실내 시험시공 결과, DCM 개량구간 내에서 상사율로 환산한 실제 융기고는 0~8.18m로 평균 3.50m로 관측되었고, 상사율로 환산한 부상토의 실제 확산범위는 개량구간 좌/우측 바깥쪽으로 28.0~38.0m 까지 분포하였다. 실내 시험시공한 결과를 SUFFER 프로그램으로 계산한 부상토의 총융기량은 19,901m3로, 주입한 물시멘트량 16,992m3와 비교하면 주입량 대비 융기량은 85.4%로 분석되었다. 또한, DCM 실내 시험시공 결과, DCM 부상토의 확산각은 개량심도 50.0m에 대하여 30.0~38.0°로 측정되어 평균 34.0°로 평가되었다. 한편, 본 연구에서 수행한 DCM 실내 시험시공과 프로그램을 이용한 분석 결과를 토대로 DCM 타설 심도 40.0m와 60.0m에서의 부상토 융기량을 예측하였다.

광 페룰 에폭시 자동주입 시스템 설계 및 성능시험에 관한 연구 (A Study on the Design and Performance Test of Optical Ferrule Epoxy Injection System)

  • 곽이구
    • 한국공작기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.118-123
    • /
    • 2008
  • Weakness process can be called ferrule array and epoxy filling process at connector manufacturing process, and a lot of problems happen as think as general manufacturing process at early investment. Wished to improve this and working environment mend of worker on childhood(planning phase) and problem that is happened at done ferrule array and epoxy injection by emphasis target. By ferrule sorting and Improvement of epoxy filling process, bring authoritativeness elevation of product by fraction defective decrease of product by sized work along with productivity elevation. On the other hand, working jigs are various in characteristics of optical connector manufacturing line. There have been lots of restriction in practice because the applicability of this system is only for single type model though the network should be smooth between lines. Thus, it is not only needed the recognition of necessity in industrial line but also the development of automation system arraying ferrule and filling epoxy in the manufacturing process. It is found that the present system development enhances productivity fairly and prevents industrial disaster in the optical connector manufacturing system.

An Analysis of Critical Heat Flux on the External Surface of the Reactor Vessel Lower Head

  • Yang, Soo-Hyung;Baek, Won-Pil;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1999년도 추계학술발표회요약집
    • /
    • pp.190-190
    • /
    • 1999
  • CHF (Critical heat flux) on the external surface of the reactor vessel lower head is major key in the evaluation on the feasibility of IVR-EVC (In-Vessel Retention through External Vessel Cooling) concept. To identify the CHF on the external surface, considerable works have been performed. Through the review on the previous works related to the CHF on the external surface, liquid subcooling, induced flow along the external surface, ICI (In-Core Instrument) nozzle and minimum gap are identified as major parameters. According to the present analysis, the effects of the ICI nozzle and minimum gap on CHF are pronounced at the upstream of test vessel: on the other hand, the induced flow considerably affects the CHF at downstream of test vessel. In addition, the subcooling effect is shown at all of test vessel, and decreases with the increase in the elevation of test vessel. In the real application of the IVR-EVC concept, vertical position is known as a limiting position, at which thermal margin is the minimum. So, it is very important to precisely predict the CHF at vertical position in a viewpoint of gaining more thermal margins. However, the effects of the liquid subcooling and induced flow do not seem to be adequately included in the CHF correlations suggested by previous works, especially at the downstream positions.

  • PDF

The factors that influence postoperative stability of the dental implants in posterior edentulous maxilla

  • Kim, Yun-Ho;Choi, Na-Rae;Kim, Yong-Deok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제39권
    • /
    • pp.2.1-2.6
    • /
    • 2017
  • Background: All clinicians are aware of the difficulty of installing a dental implant in posterior maxilla because of proximate position of maxillary sinus, insufficient bone width, and lower bone density. This study is to examine which factors will make the implantation in the posterior maxilla more difficult, and which factors will affect the postoperative implant stability in this region. Methods: Five hundred seventy-three fixtures on the maxilla posterior were included for this study from all the patients who underwent an installation of the dental implant fixture from January 2010 to December 2014 at the Department of Oral and Maxillofacial Surgery in Pusan National University Dental Hospital (Yangsan, Korea). The postoperative implant stability quotient (ISQ) value, fixture diameter and length, presence of either bone graft or sinus lift, and graft material were included in the reviewed factors. The width and height of the bone bed was assessed via preoperative cone beam CT image analysis. The postoperative ISQ value was taken just before loading by using the OsstellTM $mentor^{(R)}$ (Integration Diagnostics AB, Gothenburg, Sweden). The t test and ANOVA methods were used in the statistical analysis of the data. Results: Mean ISQ of all the included data was 79.22. Higher initial bone height, larger fixture diameter, and longer fixture length were factors that influence the implant stability on the posterior edentulous maxilla. On the other hand, the initial bone width, bone graft and sinus elevation procedure, graft material, and approach method for sinus elevation showed no significant impact associated with the implant stability on the posterior edentulous maxilla. Conclusions: It is recommended to install the fixtures accurately in a larger diameter and longer length by performing bone graft and sinus elevation.

The safety of one-per-mil tumescent infiltration into tissue that has survived ischemia

  • Prasetyono, Theddeus Octavianus Hari;Nindita, Eliza
    • Archives of Plastic Surgery
    • /
    • 제46권2호
    • /
    • pp.108-113
    • /
    • 2019
  • Background The aim of this study was to assess the safety of one-per-mil tumescent injections into viable skin flaps that had survived an ischemic insult, in order to assess the potential suitability of one-per-mil tumescent injections in future secondary reconstructive procedures such as flap revision and refinements after replantation. Methods Forty groin flaps harvested from 20 healthy Wistar rats weighing 220 to 270 g were subjected to acute ischemia by clamping the pedicle for 15 minutes. All flaps showing total survival on the 7th postoperative day were randomly divided into group A (one-per-mil tumescent infiltration; n=14), group B (normal saline infiltration; n=13), and group C (control, with no infiltration; n=13) before being re-elevated. Transcutaneous oxygen tension ($TcPO_2$) was measured before and after infiltration, and changes in $TcPO_2$ were statistically analyzed using analysis of variance, the paired t-test, and the independent t-test. The viability of flaps was also assessed using the Analyzing Digital Images software at 7 days after the second elevation. Results Thirty-nine flaps survived to the final assessment, with the sole exception of a flap from group A that did not survive the first elevation. $TcPO_2$ readings showed significant decreases (P<0.05) following both one-per-mil tumescent ($99.9{\pm}5.7mmHg$ vs. $37.2{\pm}6.3mmHg$) and normal saline ($103{\pm}8.5mmHg$ vs. $48.7{\pm}5.9mmHg$) infiltration. Moreover, all groin flaps survived with no signs of tissue necrosis. Conclusions One-per-mil tumescent infiltration into groin flap tissue that had survived ischemia did not result in tissue necrosis, although the flaps experienced a significant decrease of cutaneous oxygenation.

협심증이 의심되는 환자에서 운동부하검사로 유발되는 흉통의 양상과 생리적 변인에 관한 연구 (A study on characteristics and physiological variables of chest pain induced by exercise test in angina suspected patients)

  • 조미경;최명애
    • Journal of Korean Biological Nursing Science
    • /
    • 제2권2호
    • /
    • pp.1-19
    • /
    • 2000
  • The purpose of this study was to identify the characteristics and physiological variables of chest pain induced by exercise test in angina suspected patients. The subjects of this study consisted of 28 inpatients and outpatients aged between 40 and 75 who underwent treadmill test at exercise testing laboratory of S-University from January 2000 to June 2000. Subjects were interviewed with questionnaire regarding sociodemography, the past health history and history related to chest pain before the exercise test. Subjects were interviewed with questionnaire concerning quality, intensity, duration of chest pain induced by walking on the treadmill(Marquette, U.S.A. 1992) according to Bruce protocol following exercise test. Systolic and diastolic blood pressure were measured before, during and after the test, heart rate was determined by ECG. The results of this study were as follows ; 1) Quality of chest pain induced by exercise test were feeling stiffness 19(67.9%), heavy 10(36.0%), exploded 9(32.1%), crushing, suffocating, tight 8(28.6%), stuffy, prickly 7(25.0%), burning 6(21.4%), clasp 5(17.9%), cleaved, tensed, piercing 3(10.7%), perfectly fitting, sore 2(7.1%), tearing, tingling, ticklish, heartburn 1(3.6%). 2) Mean score of VAS(intensity of pain) following exercise test was $5.79{\pm}2.27$ and mean duration of chest pain after the test was $7.83{\pm}5.31$ minutes. 3) Sites of chest-pain induced by exercise test were middle site 11(39.3%), left-chest 10(35.6%), right-chest 6(21.5%). Radiation site of chest-pain was neck(18.0%), right flank site 1(3.6%), left shoulder & arm 2(7.1%) and back 1(3.6%). 4) Symptoms other than chest-pain induced by exercise test were dyspnea 21(75.6%), perspiration 14(50.4%), fatigue 12(43.2%), leg-pain 11(39.6%), dizziness 7(25.2%) anxiety toward chest-pain 3(10.8%), thirst 2(7.1%), and palpation, headache and tingling sensation of hand and leg 1(3.6%). 5) Mean MET(intensity of exercise) during the exercise test was $7.64{\pm}2.57$ and mean RPE(rating of perceived exertion) was $15.89{\pm}2.36$. Mean duration of exercise was $6.79{\pm}2.88$. 6) correlation coefficients between RPE and VAS was 0.500(p=0.003), those between MET and VAS was 0.287(p=0.069) and those between either depression or elevation of ST segment and VAS was 0.236(p=0.114). 7) There was a significant difference in mean systolic pressure between before and after the test as $146.29{\pm}28.18mmHg$ and $177.96{\pm}28.82mmHg$(t=-5.640, p=0.000), a significant difference in mean diastolic blood pressure between before and after the test as $84.85{\pm}15.07mmHg$ and $88.89{\pm}13.72mmHg$(t=-2.082, p=0.047), and there was a significant difference in mean heart-rate between before and after the test as $81.89{\pm}12.22/min$ and $160.68{\pm}21.77/min$(t=-21.255, p=0.000).

  • PDF

혈액-뇌장벽 투과성에 대한 히스타민의 영향 (Influences of Histamine on Permeability across Blood-brain Barrier)

  • 김기진;신동훈
    • The Korean Journal of Physiology
    • /
    • 제2권2호
    • /
    • pp.33-43
    • /
    • 1968
  • Histamine, 0.5 mg as histamine base in 4 ml of normal saline solution, was injected into rabbits anesthetized with nembutal and the mean blood pressure was kept in the range of $52{\sim}80\;mmHg$ for over one hour by supplemental additions. Following the injection of the test substances, 300 mg of urea and 200 mg of antipyrine intravenously, serial blood samples were obtained from the femoral artery and the internal jugular vein at $0.5{\sim}3$ minutes interval. The decreasing patterns in the concentrations of arterial and venous blood plasma samples were compared with each other. The ratio of the concentration of brain tissue to that of the final arterial plasma was also studied. By these measures the degrees of penetration of the test substances in the brain in the control and in the histamine treated rabbits were observed. The concentrations of antipyrine and urea in the arterial blood plasma were decreasing exponentially with respect to the time elapsed. The venous concentrations were anticipated to increase initially and to cross the arterial concentration curve in the point of equlibrium between the plasma and the tissue. On the contrary to the expectation venous concentration also revealed the decreasing tendency similar to that of arterial plasma. The similarity between these two curves, arterial and venous, would be atributable to the fact that the cerebral blood flow rate was large enough and the rising phase in the venous concentration curve was instantly over before serial blood samples were taken. Inspite of some similarity in the decreasing tedency in both concentration curves there were appreciable discrepancies between the arterial and venous plasma which would reflect the situation far from the equlibria among several compartments in the brain. Changes in plasma potassium levels caused by the injection of histamine or bleeding were observed, too. Using 8 rabbits as the control and 12 rabbits for the histamine treated group following results were obtained: 1. Both of the concentration curves, arterial and venous, declined rapidly at_first and slowly later on and approached same equilibrium concentration with the passage of time after a single injection. The time at which attained the same concentration was $2.0{\pm}0.54\;min.$ in the control and $4.3{\pm}1.92\;min.$ in the histamine treated group with respect to antipyrine. On the other hand in the case of urea they were $2.4{\pm}0.59\;min.$ in the control and $4.4{\pm}1.31\;min.$ in the histamine group, respectively. In the histamine treated group enlarged spaces for distribution of test substances were postulated. 2. The concentration of antipyrine in the brain tissue water revealed no significant differences between the control and experimental groups, showing $212{\pm}40.2\;mg/l$ in the control and $206{\pm}64.1\;mg/l$ in the histamine treated group. On the other hand urea revealed higher value in the histamine treated group than in the control, showing an enhanced penetration of urea into the tissue after injection of histamine. Urea concentration in the brain water was $32.3{\pm}3.36\;mg%$ in the control and $39.2{\pm}4.25\;mg%$ in the histamine treated group. 3. The distribution ratio of antipyrine in the brain tissue was very close to unity in the histamine treated animals as well as in the control. 4. The average of the distribution ratio of urea in the control animals was 0.77 and it showed the presence of blood-brain barrier with regard to urea. However in the histamine treated animals the distribution ratios climbed up to 0.86 and they were closer to unity than in the control animals. Out of 12 cases 5 were greater than 0.9 and 8 exceeded 0.85. It appeared that histamine enhanced the penetration of urea through the barrier. 5. Histamine injection and or hemorrhage caused an elevation of the concentration of potassium in plasma. In the event that histamine and hemorrhage were applied together the elevation of potassium exceed the elevation seen at the histamine alone. There was no evidence that the leakage of potassium from the brain tissue was dominant in comparison with the general leakage from the whole body.

  • PDF