• 제목/요약/키워드: Hand and Fingers

검색결과 287건 처리시간 0.025초

수부 손상에서 정맥이식의 유용성 (Usefulness of Venous Graft in Hand Injury)

  • 이학승;김연환;김창연;김정태;안희창
    • Archives of Plastic Surgery
    • /
    • 제37권4호
    • /
    • pp.396-399
    • /
    • 2010
  • Purpose: In hand injury, pedicle is usually damaged by avulsion injury or crushing injury. Because of postoperative pedicle obliteration, it is often hard to save the injured hand and fingers, even after successful replantation. The author introduces three cases of extensive hand injury, and successful results after applicatoin of multiple venous grafts to these patients. Methods: In all cases there was no circulation in any finger. In the first case, some vessels were extracted, so venous graft was applied to two sites of severely damaged venous sites. In the second case, venous grafts were applied to all four digital arteries of all fingers except thumb which got severely crushed, and two sites of dorsal veins. In the third case, venous graft was applied to all four digital arteries of all five fingers, and two sites of dorsal veins and palmar veins each. Results: In all cases, survival of hands and fingers was successful. In the second case, however, amputation in thumb and little finger at DIP joint level was inevitable, because of its severe damage, and the large dorsal defect on index finger was filled with DIEP free flap. Thumb was reconstructed with toe-to-thumb free flap, and additional debulking procedures and contracture release is furtherly needed. In the first case, additional surgery was done, as FDP tendon got re-ruptured, but in long term follow-up, satisfactory range of motion was attained. In the third case, FTSG on dorsal skin region was planned. as flap on dorsal area got partial necrosis. Conclusion: In hand injury, there are many structures to be repaired, but sometimes venous graft is avoided for its long operating time. Even though the length of damaged vessel is enough for anastomosis, the endothelium is often damaged (zone of injury). In extensive hand injury, successful reconstruction would be possible with active venous graft to all vessels suspicious for damage.

적외선 영상을 이용한 실시간 손동작 인식 장치 개발 (The Development of a Real-Time Hand Gestures Recognition System Using Infrared Images)

  • 지성철;강선우;김준식;주효남
    • 제어로봇시스템학회논문지
    • /
    • 제21권12호
    • /
    • pp.1100-1108
    • /
    • 2015
  • A camera-based real-time hand posture and gesture recognition system is proposed for controlling various devices inside automobiles. It uses an imaging system composed of a camera with a proper filter and an infrared lighting device to acquire images of hand-motion sequences. Several steps of pre-processing algorithms are applied, followed by a background normalization process before segmenting the hand from the background. The hand posture is determined by first separating the fingers from the main body of the hand and then by finding the relative position of the fingers from the center of the hand. The beginning and ending of the hand motion from the sequence of the acquired images are detected using pre-defined motion rules to start the hand gesture recognition. A set of carefully designed features is computed and extracted from the raw sequence and is fed into a decision tree-like decision rule for determining the hand gesture. Many experiments are performed to verify the system. In this paper, we show the performance results from tests on the 550 sequences of hand motion images collected from five different individuals to cover the variations among many users of the system in a real-time environment. Among them, 539 sequences are correctly recognized, showing a recognition rate of 98%.

중풍 편마비 환자의 손 기능 회복에 대한 팔사혈(八邪穴) 자침(刺鍼)의 임상적 효과 (The Clinical Effectiveness of Acupuncture at Palsa(BaXie) for Hand Function in Hemiparetic Patients after Stroke)

  • 김자영;정선미;박찬규;민은경;왕덕중
    • Journal of Acupuncture Research
    • /
    • 제25권5호
    • /
    • pp.97-104
    • /
    • 2008
  • Objectives : Investigate the effectiveness of an acupuncture at Palsa(BaXie) in hemiparetic patients after stroke. Methods : Acupuncture at Palsa(BaXie) applied to thirty one hemiparetic patients who had been by general treatment after stroke. The other thirty one hemiparetic patients had only general treatment. Outcomes were assessed by Medical research council scale motor grade(MRCSMG) of wrist, grip power, Fugl-Meyer Motor Scale(FMS) of hand, and Motricity Index(MI) of fingers. Results : The patients exhibited substantial improvements on grip power and Fugl-Meyer Motor Scale of hand, but Medical research council scale motor grade of wrist and Motricity Index of fingers have not significantly meaningful differences between sample and control group. Conclusions : Acupuncture at Palsa(BaXie) may be an effective method of improving hand function of hemiparetic patients after stroke.

  • PDF

장갑 패턴 개발을 위한 손의 유형 분류 (Classification of Hand Types for the Development of Glove Patterns)

  • 임지영
    • 대한가정학회지
    • /
    • 제43권8호
    • /
    • pp.115-122
    • /
    • 2005
  • The hand performs functions such as grabbing and other movements. In order to accomplish these movements in various kinds of operational environments, appropriate gloves must be worn to protect your hands. Choosing the appropriate type of glove is very important when wearing gloves in these types of operational environments. The reasons one wears gloves varies depending on age and gender. Unmarried women in their early twenties, for example, occasionally wear gloves for decoration rather than for functional reasons. However, previous studies examined a range of topics, and as such investigations dealing with specific body shape and demands of consumer are needed. Therefore in this study, the hands of unmarried women ranging in age from 20 to 24 were measured and hand shape types were analyzed in order to present basal data which can be used to help design improved glove patterns and produce appropriate, functional gloves. A total of 261 Korean women were measured. Fifty-seven right hand dimensions were measured and five dimensions from both hands were measured. Six factors were identified through factor analysis and those factors constituted $73.259\%$ of total variance. Two clusters of hand shapes were categorized using 6 factor scores by cluster analysis. Type 1 hand shape is defined as long hands with small width, girth, and thickness, long and thin fingers, and high vertical palm height. Type 2 hand shape is defined as short hands with large width, girth and thickness, short fingers, thick knuckles, and short vertical palm height. The characteristics of type 1 and 2 hand shapes are similar to women's hand type classification results from previous reports, but there was a significant difference in subject distribution by type. Therefore, standard data on hand shapes should be produced by developing measuring instruments and selling more accurate standard measuring points. By doing this it could help in the development of improved glove patterns, and also aid in planning production based on hand type.

Design and Control of a Dexterous Multi-fingered Robot Hand

  • Chung, Woo-Jin;Lee, Hyung-Jin;Kim, Mun-Sang;Lee, Chong-Won;Kang, Bong-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.83.1-83
    • /
    • 2001
  • This paper presents a three-fingered robot hand, called the KIST hand, Which have one active joint and one passive joint. The thumb is fixed on the palm, and the index and the middle take lateral motions symmetrically. A mechanical clutch and an embedded force sensor, attached on the distal link of the fingers, enable the KIST hand to perform human-like functions. A result of experiment shows reliable grasping performance of the hand which maintain stable grasp under disturbances.

  • PDF

Fingernail Configuration

  • Jung, Jin Woo;Kim, Kwang Seog;Shin, Jun Ho;Kwon, Yu Jin;Hwang, Jae Ha;Lee, Sam Yong
    • Archives of Plastic Surgery
    • /
    • 제42권6호
    • /
    • pp.753-760
    • /
    • 2015
  • Background A number of conditions can alter a person's fingernail configuration. The ratio between fingernail width and length (W/L) is an important aesthetic criterion, and some underlying diseases can alter the size of the fingernail. Fingernail curvature can be altered by systemic disorders or disorders of the fingernail itself. Although the shape and curvature of the fingernail can provide diagnostic clues for various diseases, few studies have precisely characterized normal fingernail configuration. Methods We measured the W/L ratio of the fingernail, transverse fingernail curvature, hand length, hand breadth, and distal interphalangeal joint width in 300 volunteers with healthy fingernails. We also investigated whether age, sex, height, and handedness influenced the fingernail W/L ratio and transverse fingernail curvature. Results In women, fingernail W/L ratios were similar across all five fingers, and were lower than those in men. The highest value of transverse fingernail curvature was found in the thumb, followed by the index, middle, ring, and little fingers. Handedness and aging influenced transverse fingernail curvature, but not the fingernail W/L ratio. Fingernails were flatter on the dominant hand than on the non-dominant hand. The radius of transverse fingernail curvature increased with age, indicating that fingernails tended to flatten with age. Conclusions Our quantitative data on fingernail configuration can be used as a reference range for diagnosing various diseases and deformities of the fingernail, and for performing reconstructive or aesthetic fingernail surgery.

Photo-Plethysmography를 이용한 정상과 재접합 수지 혈류량의 비교 (Comparison of normal and replantation digital blood flow using photo-plethysmography)

  • 남기창;김성우;나동균;김덕원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.322-324
    • /
    • 2004
  • Up to the present, digital replantation patients has appealed different symptoms due to blood circulatory failure. But, the level of blood circulatory failure has been evaluated only by clinical symptoms, or angiography. According to the cases of digit replantation is increasing, then objective evaluation methods of the level of blood circulation failure is needed other than patient's subjective symptoms and complaints. Although angiography, doppler, electromagnetic flowmeter, laser blood flowmeter, mechanical blood flowmeter has been used for the evaluation of the blood circulatory failure, the result was affected by time, place, surrounding temperature, patient's body temperature, and even emotion. Therefore, it is pointed out with lack of availability, feasibility and reproducibility. Thus, we compared digital blood flow of dominant hand to non dominant hand, and replanted fingers to opposite normal fingers from developed photo-plethysmography. The average digital blood flow showed no difference in normal digits each other, but, replanted digits showed average of 53% (9 - 100 %) compare to opposit normal digits. As it measure relative blood flow for circulatory failure of tissue such as fingers and toes more sensitively, reliably. In conclusion, it is expected that photo- plethysmography will be very useful for diagnosis, curative effect, prognosis of blood circulatory failure in digital replantation patient.

  • PDF

Position control for multifingered robot hand

  • Kim, Jung-Ha;Jeong, Kyu-Won;Youm, Young-Il
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1779-1784
    • /
    • 1991
  • The problem of fine manipulation is considered in this paper. By fine manipulation, we mean the positioning of the object relative to the palm as opposed to gross manipulation by the arm. The compliance in the fingers and the object is modeled by linear springs. It is shown that the motion of the fingers and object can be predicted by minimizing a quadratic objective function. A method for simulating position control algorithms is developed.

  • PDF

손/팔의 기능적 치수 측정시스템 (A system measuring the functional dimension of the hand and arm)

  • 이경태;강신길;박재희
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1996년도 추계학술대회논문집
    • /
    • pp.219-224
    • /
    • 1996
  • By integrating the wired-glove and the position sensor using the magnetic fields, we developed the system which could measure the functional dimension of the hand and arm of the human. Magnetic position sensor traces the position and orientation of the arm while the wired-glove measures 18 phalangeal joint angles(including abduction between fingers, pitch and yaw of the wiist). The system could be used to monitor and quantify the functional dimension of the hand and arm and also could be used to test the product usability where the hand motion is important. Another important application lies in determining the degree of paralysis.

  • PDF

Biometric analysis hand parameters in young adults for prosthetic hand and ergonomic product applications

  • Gkionoul Nteli Chatzioglou;Yelda Pinar;Figen Govsa
    • Anatomy and Cell Biology
    • /
    • 제57권2호
    • /
    • pp.172-182
    • /
    • 2024
  • This study aimed to evaluate the superficial anatomy, kinesiology, and functions of the hand to reveal its morphometry and apply the findings in various fields such as prosthetic hand and protective hand support product design. We examined 51 young adults (32 females, 19 males) aged between 18-30. Hand photographs were taken, and measurements were conducted using ImageJ software. Pearson correlation analysis was performed to determine the relationship between personal information and the parameters. The results of the measurements showed the average lengths of finger segments: thumb (49.5±5.5 mm), index finger (63.9±4.1 mm), middle finger (70.7±5.2 mm), ring finger (65.5±4.8 mm), and little finger (53.3±4.3 mm). Both females and males, the left index finger was measured longer than the right index finger. The right ring finger was found to be longer than the left in both sexes. Additionally, length differences between fingers in extended and maximally adducted positions were determined: thumb-index finger (56.1±6.2 mm), index-middle finger (10.7±4.1 mm), middle-ring finger (10.8±1.4 mm), and ring-little finger (25.6±2.7 mm). Other findings included the average radial natural angle (56.4°±10.5°), ulnar natural angle (23.4°±7.1°), radial deviation angle (65.2°±8.2°), ulnar deviation angle (51.2°±9.6°), and grasping/gripping angle (49.1°±5.8°). The average angles between fingers in maximum abduction positions were also measured: thumb-index finger (53.4°±6.5°), index-middle finger (17.2°±2.6°), middle-ring finger (14.3°±2.3°), and ring-little finger (32.1°±7.0°). The study examined the variability in the positioning of proximal interphalangeal joints during maximum metacarpophalangeal and proximal interphalangeal flexion, coinciding with maximum distal interphalangeal extension movements. The focal points of our observations were the asymmetrical and symmetrical arches formed by these joints. This study provides valuable hand parameters in young adults, which can be utilized in various applications such as prosthetic design, ergonomic product development, and hand-related research. The results highlight the significance of considering individual factors when assessing hand morphology and function.