• 제목/요약/키워드: Hand Signal

검색결과 592건 처리시간 0.032초

수전달 진동 피폭 저감을 위한 방진 장갑의 성능 평가 (Assessment of Anti-vibration Gloves for Reduction of Hand-transmitted Vibration Exposure)

  • 최석현;홍석인;장한기
    • 한국산업보건학회지
    • /
    • 제18권1호
    • /
    • pp.1-10
    • /
    • 2008
  • In order to evaluate performance of anti-vibration gloves, it is necessary to measure the transmitted vibration to the hand and the applied forces at the same time while gripping the vibrating handle. In the study a system was developed to measure both the vibration and the forces. The system consists of a measurement handle with eight strain gauges and two accelerometers and a PC-based system with a software for signal processing, evaluation of the hand-transmitted vibration and for control of applied forces in the pre-determined range. The handle was installed on the vibration shaker which is strong enough so as not to be affected by dynamic coupling with the hand-arm. Whole procedure of ISO 10819:1996 to determine the vibration transmissibility of anti-vibration gloves was programmed into the system. As an example of the application, three subjects joined the test to get vibration transmissibilities of 9 anti-vibration gloves where each glove was tested twice a subject. Average and standard deviation of the corrected vibration transmissibility were also calculated. All tested gloves fulfilled criterion for M-spectrum($\overline{TR_M}$<1.0), but one glove fulfilled criterion for H-spectrum($\overline{TR_H}$<6.0),

로봇 핸드 제어를 위한 센서 기반 손 동작 인식 (Sensor-based Recognition of Human's Hand Motion for Control of a Robotic Hand)

  • 황면중
    • 한국산학기술학회논문지
    • /
    • 제15권9호
    • /
    • pp.5440-5445
    • /
    • 2014
  • 사람의 생체 신호를 측정하여 로봇 제어에 이용하는 연구는 최근까지 활발히 진행되고 있다. 하지만 정확한 센서 정보를 위한 복잡한 신호 처리가 필요하고 고가의 시스템을 필요로 하는 단점이 있다. 본 논문에서는 저가의 EMG 센서와 Flex 센서로부터 측정된 신호를 이용하여 사람의 손 동작을 인식한 후 해당 움직임을 원격지의 로봇 핸드로 구현하는 것을 목표로 한다. MCU(Micro Controller Unit) 와 해당 센서들을 이용하여 실험적으로 사람의 손과 팔 부근의 3개의 센서 부착 위치를 결정하고 움직임에 따른 출력 신호와 실제 동작 사이의 구분 방법을 결정한다. 동작 인식 정확도를 높이기 위해 MCU의 아날로그 기준 전압에 따른 디지털 값 변화 실험 수행 후 기준 전압을 3.3V로 선정하였다. 손 동작을 구현하기 위해 4개의 손가락과 손목부분으로 구성된 링크 구조의 로봇 핸드를 설계한 후 제작하였다. 결과적으로 간단한 센서와 저가의 MCU를 활용하여 원격지의 로봇 핸드를 제어할 수 있음을 보였다.

유비쿼터스 환경에서 사용 가능한 핸드 헬드형 3차원 움직임 추적장치 (A Handheld 3-Dimensional Motion Tracking Device for Ubiquitous Computing Environment)

  • 박명관;이상훈;서일홍
    • 제어로봇시스템학회논문지
    • /
    • 제11권12호
    • /
    • pp.1045-1050
    • /
    • 2005
  • This paper describes a design experience of a low-cost 6 DOF spatial tracker system where relative low accuracy and relatively long ranges, wireless communication will be achieved by means of low cost accelerometers and gyros with contemporary microprocessor. However, there are two key problems; one is the bias drift problem and the other is that single or double integration of acceleration signal suffers not only from noise but also from nonlinear effects caused by gravity. To be specific, beginning and stopping of hand motions needs to be accurately detected to initiate and terminate integration process to get position and pose of the hand from accelerometer and gyro signals, since errors due to noise and/or hand-shaking motions accumulated by integration processes. Several experimental results are shown to validate our proposed algorithms.

System indentification using multiple decimation method and design of PID-ATC

  • Byun, Hwang-Woo;Moon, Joon-Ho;Lee, In-Hee;Lee, Un-Cheol;Kim, Lark-Kyo;Nam, Moon-Hyon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.682-688
    • /
    • 1994
  • LSM(Least-Squares Method) has inherent limitation that precise system identification over wide frequency band is difficult especially at low frequency hand. In this paper we propose to use decimation, a spectrum analysis method widely used in signal processing. The merits of decimation are the flexibility of selection of the frequency hand concerned and the function of LPF(Low Pass Filter). In this paper, frequency-domain is divided into separate frequency bands which will be combined into full frequency-domain by using MDM(Multiple Decimation Method). In this way, free selection of sampling frequency for each hand is possible and the low frequency oscillation modes of LSM are avoided.

  • PDF

HandButton: Gesture Recognition of Transceiver-free Object by Using Wireless Networks

  • Zhang, Dian;Zheng, Weiling
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권2호
    • /
    • pp.787-806
    • /
    • 2016
  • Traditional radio-based gesture recognition approaches usually require the target to carry a device (e.g., an EMG sensor or an accelerometer sensor). However, such requirement cannot be satisfied in many applications. For example, in smart home, users want to control the light on/off by some specific hand gesture, without finding and pressing the button especially in dark area. They will not carry any device in this scenario. To overcome this drawback, in this paper, we propose three algorithms able to recognize the target gesture (mainly the human hand gesture) without carrying any device, based on just Radio Signal Strength Indicator (RSSI). Our platform utilizes only 6 telosB sensor nodes with a very easy deployment. Experiment results show that the successful recognition radio can reach around 80% in our system.

Study on User Interface for a Capacitive-Sensor Based Smart Device

  • Jung, Sun-IL;Kim, Young-Chul
    • 스마트미디어저널
    • /
    • 제8권3호
    • /
    • pp.47-52
    • /
    • 2019
  • In this paper, we designed HW / SW interfaces for processing the signals of capacitive sensors like Electric Potential Sensor (EPS) to detect the surrounding electric field disturbance as feature signals in motion recognition systems. We implemented a smart light control system with those interfaces. In the system, the on/off switch and brightness adjustment are controlled by hand gestures using the designed and fabricated interface circuits. PWM (Pulse Width Modulation) signals of the controller with a driver IC are used to drive the LED and to control the brightness and on/off operation. Using the hand-gesture signals obtained through EPS sensors and the interface HW/SW, we can not only construct a gesture instructing system but also accomplish the faster recognition speed by developing dedicated interface hardware including control circuitry. Finally, using the proposed hand-gesture recognition and signal processing methods, the light control module was also designed and implemented. The experimental result shows that the smart light control system can control the LED module properly by accurate motion detection and gesture classification.

가변 전송 커버리지 기반의 Wi-Fi 네트워크에서의 데이터 전송률 (Throughput of Wi-Fi network based on Range-aware Transmission Coverage)

  • 장걸;이구연;김화종
    • 디지털콘텐츠학회 논문지
    • /
    • 제14권3호
    • /
    • pp.349-356
    • /
    • 2013
  • 최근 스마트폰과 같은 무선통신기기의 급증으로 인하여 IEEE 802.11 Wi-Fi 네트워크에서 인접 네트워크간의 신호간섭현상이 많이 발생하며, 이와 같은 신호간섭현상은 데이터 전송 품질에도 영향을 미친다. 현재 출시되고 있는 다수의 Wi-Fi 관련 제품들은 높은 데이터 전송률 및 넓은 전송범위를 보여주고 있지만, 반면 이 같은 특성은 인접한 무선기기와의 무선신호간섭 확률도 높게 한다. 무선신호간섭은 무선통신 특성상 피하기 어려운 현상이지만 통신기기의 신호전송범위를 작게 함으로서 최소화할 수 있다. 그러나 작은 신호전송범위는 낮은 송신강도를 의미하므로, 이는 낮은 데이터 전송률로 나타나게 된다. 이에 본 논문에서는 신호강도, 전송률, 신호간섭간의 상호 관계를 분석하고, 송신 강도와 전송률의 tradeoff로서 무선기기의 위치 및 RSSI(Received Signal Strength Indication)에 따라 송신강도를 가변적으로 조절하는 가변 커버리지 기반의 Wi-Fi 네트워크 방식을 제안하고, 이의 성능을 시뮬레이션을 통하여 구한다.

Visualization of Motor Unit Activities in a Single-channel Surface EMG Signal

  • Hidetoshi Nagai
    • International journal of advanced smart convergence
    • /
    • 제12권3호
    • /
    • pp.211-220
    • /
    • 2023
  • Surface electromyography (sEMG) is a noninvasive method used to capture electrically muscle activity, which can be easily measured even during exercise. The basic unit of muscle activity is the motor unit, and because an sEMG signal is a superposition of motor unit action potentials, analysis of muscle activity using sEMG should ideally be done from the perspective of motor unit activity. However, conventional techniques can only evaluate sEMG signals based on abstract signal features, such as root-mean-square (RMS) and mean-power-frequency (MPF), and cannot detect individual motor unit activities from an sEMG signal. On the other hand, needle EMG can only capture the activity of a few local motor units, making it extremely difficult to grasp the activity of the entire muscle. Therefore, in this study, a method to visualize the activities of motor units in a single-channel sEMG signal by relocating wavelet coefficients obtained by redundant discrete wavelet analysis is proposed. The information obtained through this method resides in between the information obtained through needle EMG and the information obtained through sEMG using conventional techniques.

청각 보철용 음성신호 처리기의 설계 (Design of the Speech Signal Processores for Cochlear Prosthesis)

  • 박상희;최두일;백승화
    • 대한의용생체공학회:의공학회지
    • /
    • 제12권4호
    • /
    • pp.285-294
    • /
    • 1991
  • Two types of the speech signal processores (SSP) for the cochlear a prosthesis are designed. One is designed using the cochlear model and the other is designed using the information (formant, pitch, intensity) extraction method. For these, some cochlear model and acoustic information extraction method are proposed. The result shows the SSP of the cochlear model type contain more acoustic cues than that of information extraction type. On the other hand, stimulus signal is clear and algorithm is simple in the SSP of the information ex traction type.

  • PDF

PDA 기반 포터블 진동 신호 분석기 개발 (Development of a Portable Device based on PDA for Vibration Signal Analysis)

  • 김동준;박광호;기창두
    • 한국정밀공학회지
    • /
    • 제19권12호
    • /
    • pp.179-184
    • /
    • 2002
  • In this study, we developed a portable device which can monitor and analyze vibration signals from machines. This system consists a PDA loading the program for vibration analysis and A/D board for vibration acquisition. A PDA is smaller than the palm of the hand, but it has a powerful computing ability as much as an IBM compatible PC with a Pentium 100MHz CPU. The A/D board developed in this study supports LAN interface using TCP/IP communication protocol. The application program for vibration analysis includes signal processing module, fault diagnosis module, data store module, and plot display module. MS visual embedded C++ 3.0 was used to developed the program.