• Title/Summary/Keyword: Hand Device

Search Result 781, Processing Time 0.024 seconds

Studying the operation of MOSFET RC-phase shift oscillator under different environmental conditions

  • Ibrahim, Reiham O.;Abd El-Azeem, S.M.;El-Ghanam, S.M.;Soliman, F.A.S.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1764-1770
    • /
    • 2020
  • The present work was mainly concerned with studying the operation of RC-phase shift oscillator based on MOSFET type 2N6660 under the influence of different temperature levels ranging from room temperature (25 ℃) up-to135 ℃ and gamma-irradiation up-to 3.5 kGy. In this concern, both the static (I-V) characteristic curves of MOSFET devices and the output signal of the proposed oscillator were recorded under ascending levels of both temperature and gamma-irradiation. From which, it is clearly shown that the drain current was decreased from 0.22 A, measured at 25 ℃, down to 0.163 A, at 135 ℃. On the other hand, its value was increased up-to 0.49 A, whenever the device was exposed to gamma-rays dose of 3.5 kGy. Considering RC-phase shift oscillator, the oscillation frequency and output pk-pk voltage were decreased whenever MOSFET device exposed to gamma radiation by ratio 54.9 and 91%, respectively. While, whenever MOSFET device exposed to temperature the previously mentioned parameters were shown to be decreased by ratio 2.07 and 46.2%.

Leveraging the Smart device for waterworks manhole management (상수도맨홀 관리를 위한 스마트 관리장치의 활용)

  • Chun, Haebok;Kim, Yeongkwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.141-148
    • /
    • 2017
  • The waterworks company is in charge of managing water facilities buried underground, and the management has been centered on manholes. However, since there is no standard management manual, it has been impossible to introduce and operate a systemized managing tool by water service providers and managers, and manhole management has been carried out by individual data recording personnel for each water service provider. When the management is carried out individually, the data to be shared by other waterworks managers tend to be privatized, and consequently, it may become a big obstacle to proceed with many civil works such as emergency leak repair, road excavation, replacement of old buildings. This report introduces RFID (Radio Frequency Identification) system which is based on the magnetic field capable of IOT. It also describes the necessity of leveraging the system for smart managing of pipe management record that has been done by hand writing. The RFID system includes RFID marker, data reader, portable computer operating program, and data base server operating program. In this system, the data is managed with a single communication device, and it would be possible to share the information on the underground facilities and water treatment facilities. This RFID technology is expected to provide water service providers with opportunities to develop more scientific and modernized underground facilities information systems.

Direct Printable Nanowire p-n Junction device

  • Lee, Tae-Il;Choi, Won-Jin;Kar, Jyoti Prakash;Moon, Kyung-Ju;Lee, Min-Jung;Jun, Joo-Hee;Baik, Hong-Koo;Myoung, Jae-Min
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.30.2-30.2
    • /
    • 2010
  • Nano-scale p-n junction can generate various nano-scale functional devices such as nanowire light emitting diode, nanowire solar cell, and nanowire sensor. The core shell type nanowire p-n junction has been considered for the high efficient devices in many previous reports. On the other hand, although device efficiency is relatively lower, the cross bar type p-n junction has simple topological structure, suggested by C.M. Lieber group, to integrate easily many p-n junction devices in one board. In this study, for the integration of the cross bar nanowire p-n junction device, a simple fabrication route, employed dielectrophoretic array and direct printing techniques, was demonstrated by the successful fabrication and programmable integration of the nanowire cross bar p-n junction solar cell. This direct printing process will give the single nanowire solar cell the opportunity of the integration on the circuit board with other nanowire functional devices.

  • PDF

Development of Master-slave System for Robot-assisted Remote Ultrasound Diagnosis (로봇 지원 원격 초음파 영상진단을 위한 마스터-슬레이브 시스템의 개발)

  • Seo, Joonho;Cho, Jang Ho;Kwon, Ohwon
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.4
    • /
    • pp.395-401
    • /
    • 2017
  • In this paper, we introduce a robot-assisted medical diagnostic system that enables remote ultrasound (US) imaging to be applied to the conventional telemedicine, which has been possible only with interviewing or a visual exam. In particular, a master-slave robot system is developed that ultrasonic diagnosis specialist can control the position and orientation of US probe in the remote place. The slave robot is designed to be compact, lightweight, and hand-held so that it can easily transfer to the remote healthcare center. Moreover, 6-degree-of-freedom (DOF) probe motion is possible by the robot design based on Stewart platform. The master device is also based on a similar structure of the slave robot. To connect master and slave system in the wide area network (WAN) environment, a hardware CODEC was developed. In this paper, we introduce the detail of each component and the results of the recent experiments conducted in the remote sites by the developed robotic ultrasound imaging system.

Haptic Design of a Wearable Wrist Massage Device as a Capstone Design Project of Designeer Education Program (디자이니어 양성 커리큘럼 내 융합설계프로젝트 사례: 웨어러블 손목 마사지 기기의 햅틱 디자인)

  • Lim, Dokshin;Kwon, Kyunghyun
    • Journal of Engineering Education Research
    • /
    • v.23 no.2
    • /
    • pp.43-48
    • /
    • 2020
  • This paper deals with a Capstone Design project which is a wearable haptic wrist massage device design carried out within the 'Designeer' education program. Following design thinking process is recommended throughout a year in order to ensure a desirable, feasible and viable product. Dealing with a real problem of the field requires open-minded and flexible attitudes both from students and professors. Integrating design in an engineering project does not mean always making better looking product. User experience design allows wider opportunity to engineers to deal with design. A case study of developing a wearable wrist massage device shown in this paper demonstrate haptic design and how haptic properties can be optimized to offer best user experience of hand massaging. This study identified that starting lateral pressure movements from the center in larger area using air tubes gives better feeling as self-massage using wrist wearing devices.

Current Developments of Biomedical Mobile Devices for Ubiquitous Healthcare (u-Healthcare를 위한 바이오 단말기의 개발 현황)

  • Lee, Tae-Soo;Hong, Joo-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.3
    • /
    • pp.185-190
    • /
    • 2009
  • Biomedical mobile devices for ubiquitous healthcare consist of biomedical sensors and communication terminal. They have two types of configuration. One is the sensor-network type device using wired or wireless communication with intelligent sensors to acquire biomedical data. The other is the sensor embedded type device, where the data can be acquired directly by itself. There are many examples of sensor network type, such as, fall detection sensor, blood glucose sensor, and ECG sensors networked with commercial PDA phone and commercial phone terminal for ubiquitous healthcare. On the other hand, sensor embedded type mounts blood glucose sensor, accelerometer, and etc. on commercial phone. However, to enable true ubiquitous healthcare, motion sensing is essential, because users go around anywhere and their signals should be measured and monitored, when they are affected by the motion. Therefore, in this paper, two biomedical mobile devices with motion monitoring function were addressed. One is sensor-network type with motion monitoring function, which uses Zigbee communication to measure the ECG, PPG and acceleration. The other is sensor-embedded type with motion monitoring function, which also can measure the data and uses the built-in cellular phone network modem for remote connection. These devices are expected to be useful for ubiquitous healthcare in coming aged society in Korea.

The Effect of Gesture-Command Pairing Condition on Learnability when Interacting with TV

  • Jo, Chun-Ik;Lim, Ji-Hyoun;Park, Jun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.4
    • /
    • pp.525-531
    • /
    • 2012
  • Objective: The aim of this study is to investigate learnability of gestures-commands pair when people use gestures to control a device. Background: In vision-based gesture recognition system, selecting gesture-command pairing is critical for its usability in learning. Subjective preference and its agreement score, used in previous study(Lim et al., 2012) was used to group four gesture-command pairings. To quantify the learnability, two learning models, average time model and marginal time model, were used. Method: Two sets of eight gestures, total sixteen gestures were listed by agreement score and preference data. Fourteen participants divided into two groups, memorized each set of gesture-command pair and performed gesture. For a given command, time to recall the paired gesture was collected. Results: The average recall time for initial trials were differed by preference and agreement score as well as the learning rate R driven by the two learning models. Conclusion: Preference rate agreement score showed influence on learning of gesture-command pairs. Application: This study could be applied to any device considered to adopt gesture interaction system for device control.

Implementation of Urinary Incontinence Therapy Device with Wireless Bluetooth Communication (무선 요실금 치료기의 구현)

  • Lee, Seung-Jik;Kim, Kyung-Ah;Lee, Tae-Soo;Kim, Wun-Jae;Cha, Eun-Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.197-202
    • /
    • 2006
  • Devices in current market to perform electrical stimulation therapy of the urinary incontinence frequent in aging women are very much impractical to us ε due to the wired configuration. The present study implemented new wireless device to enhance self as well as in-hospital therapy with the easiest and the most convenient application. The therapy system consisted of two modules, called 'master' and 'slave', communicating with each other by the wireless Bluetooth protocol. The patient controls therapy processes on the master module in hand, transmitting the required informations to operate the slave module placed within her pants with the viginal electrode connected, delivering appropriate electrical stimulation. Wireless communication enabled self therapy with clothes on, leading to a great convenience for the patient. The stimulation output signal was comparable to commercialized products in both waveform and stimulation capacity.

Effect of Temperature on Electrochemical Characteristics of Stainless Steel in Green Death Solution Using Cyclic Potentiodynamic Polarization Test (순환동전위 분극실험을 이용한 스테인리스강의 그린데스용액에서 전기화학적 특성에 미치는 온도의 영향)

  • Hwang, Hyun-Kyu;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.266-280
    • /
    • 2021
  • Since 2020, the International Maritime Organization (IMO) has updated regulations on the sulfur content to be less than 0.5% in exhaust gas emitted from ships. Accordingly, the exhaust gas post-treatment device for ships, which is SOx/NOx reduction technology, was introduced. However, the exhaust gas post-treatment device is suffering corrosion because of the harsh corrosive environment formed by sulfate and chlorine oxide through the desulfurization process. In this investigation, cyclic potentiodynamic polarization (CPDP) experiment for UNS S31603 and UNS N08367 was performed in a green death solution that simulates the environment of a desulfurization device. The corrosion rate of UNS S31603 at the highest temperature was about 3 times higher than that of UNS N83067. Also, electron microscope scan revealed corrosion type UNS N83067 presents intergranular corrosion tendency. On the other hand, UNS S31603 was observed as general corrosion. The α values of UNS N08367 at 30 ℃ and 60 ℃ were higher than those of UNS S31603, thus UNS N08367 is considered to have a higher local damage tendency. Whereas, since the α value of UNS S31603 at 90 ℃ is larger than that of UNS N08367, UNS S31603 is considered to have a higher local damage trend.

Hand Tracking Based Projection Mapping System and Applications (손 위치 트래킹 기반의 프로젝션 매핑 시스템 및 응용)

  • Lee, Cheongun;Park, Sanghun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.22 no.4
    • /
    • pp.1-9
    • /
    • 2016
  • In this paper we present a projection mapping system onto human's moving hand by a projector as information delivery media and Kinect to recognize hand motion. Most traditional projection mapping techniques project a variety of images onto stationary objects, however, our system provides new user experience by projecting images onto the center of the moving palm. We explain development process of the system, and production of content as applications on our system. We propose hardware organization and development process of open software architecture based on object oriented programming approach. For stable image projection, we describe a device calibration method between the projector and Kinect in three dimensional space, and a denoising technique to minimize artifacts from Kinect coordinates vibration and unstable hand tremor.