• Title/Summary/Keyword: Hammer breaker

Search Result 4, Processing Time 0.023 seconds

Application & Examination of the Plan for Optimum Stability through Water-hammer in Pipe Line and Booster Pump Station (관로계통 및 가압펌프장 수격에 따른 최적 안정성 확보방안)

  • Ra, Beyong-Pil;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.5
    • /
    • pp.19-24
    • /
    • 2009
  • This paper is performed to find out the stability of water-hammer in pipe line and pump station that is happened when additional water needs demanded. At first, the water supply construction project is planned to supply $6,000\;m^3/day$ through 17.9 km pipe line. But additional demand ($1,200\;m^3/day$) happened from Cheong-ra water reservoir. In this situation, air-chamber($4\;m^3$) and vacuum breaker valve(${\varphi}100\;mm$) are needed to prevent water-hammer. When the additional water is supplied, the existing facilities (air-chamber, vacuum breaker valve) are sufficient to alleviate shock not changing capacity alteration, judging from the airspace change and rise. Therefore, there is no problem for water-hammer by installing air-chamber($4\;m^3$) and vacuum breaker valve(${\varphi}100\;mm$) at the top of Yeo-ju hill.

Design and Analysis of a High Speed Single-phase Hybrid 4/4 poles SRM for Hammer Beaker Application

  • Jeong, Kwang-Il;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1978-1985
    • /
    • 2018
  • In this paper, a novel single-phase hybrid switched reluctance motor (HSRM) is proposed for hammer breaker application. The hammer breaker requires only unidirectional rotation and high-speed operation. To satisfy the requirements and eliminate torque dead-zone, the rotor of the proposed 4/4 poles SRM is designed with wider pole arc and non-uniform air-gap. This motor has a simple structure and produces low torque ripple. Permanent magnets (PMs) are mounted on the inner stator at a certain position which enables it to park the rotor for self-start and create positive cogging torque in the torque dead-zone. Compared with conventional single-phase switched reluctance motor, HSRM has an increased torque density and relatively low torque ripple. To verify effectiveness, finite element method (FEM) is employed to analyze the performance of the proposed structure. Then, the proposed motor is compared with the existing motor drive system for the same application. The proposed HSRM is easy to manufacture along with competitive performance.

Hand arm vibration measurement using micro-accelerometer in different brick structures

  • Gomathi, K.;Senthilkumar, A.;Shankar, S.;Thangavel, S.;Priya, R. Mohana
    • Smart Structures and Systems
    • /
    • v.13 no.6
    • /
    • pp.959-974
    • /
    • 2014
  • Hand-Arm Vibration Syndrome (HAVS) is a group of diseases caused by exposure of the hands to vibration while operating the hand held power tools such as road breaker, drilling machine, demolition hammer in construction works. In this paper, area-changed capacitive micro-accelerometer is designed to measure the vibration exposure on worker's hand when operating a drilling machine on various blocks such as clay block, paver block and solid cement block. The design process includes mathematical modelling of micro-accelerometer and simulations are done using INTELLISUITE 8.6. Experimental results are taken for various blocks surfaces using conventional and micro-accelerometer. Comparisons show that usage of area-changed micro-accelerometer for Hand-arm vibration monitoring provides better sensitivity, which in turn reduces the risk of HAVS in workers.

The Performance Characteristics of Anti-Surge Devices for High Head Cooling Water Systems in 1,000 MW Thermal Power plants (고수두 1,000 MW 석탄화력발전소 냉각수계통 수격방지장치의 성능특성)

  • Kim, Keun-Pil;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.4
    • /
    • pp.36-42
    • /
    • 2019
  • In recent, according to the tightening of environment regulation policy, the height of the site of the power plant is increased and the length of the cooling water pipe is increased. This has a serious impact on the stability of the plant. This study analyzes the transient phenomenon using LIQT 7.2, an unsteady state one-dimensional analysis software, to secure the stability of 1,000 MW high-capacity coal-fired power plant cooling water system with high head. To prevent water hammer, The effects on performance characteristics were predicted by individual and combination application. The surge pressure of the cooling water which occurs when the pump was stopped without installing the anti-surge devices was the largest at the pump outlet side. The most effective and simple way to reduce surge pressure in these cooling water systems is to combine a vacuum breaker with a hydraulic non-return valve, which is an essential device for pump protection.