• Title/Summary/Keyword: Halogen light

Search Result 165, Processing Time 0.023 seconds

A Study on Color Reproduction and Flatness of the LED Light Source in Broadcasting Lighting (방송조명에서 LED광원의 색 재현성과 평탄도 연구)

  • Kim, Young-Jin;Park, Gooman
    • Journal of Broadcast Engineering
    • /
    • v.21 no.4
    • /
    • pp.538-551
    • /
    • 2016
  • At the on-site of broadcasting production, the light source of tungsten halogen has been used as a primary light source for representing video images. Although tungsten halogen light has drawn attention in terms of the color reproducibility which is more similar to the sun light than that of other light sources, meanwhile it had problems in energy efficiency. Recently, the LED light source with high efficiency and long lifetime of the energy source has started getting attention as a substitute light source at the broadcast field. Because of the unique light emission principles, compared with tungsten halogen, LED light source has different characteristics in the quality of the light projected from the light source and color reproduction of the video image through a camera. These characteristics cause the delayed introduction of the LED as the broadcast light source. In this study we measured the quality characteristics of the flatness of the color reproduction and light of the LED light source and will present the experimental data whether it is suitable as the broadcasting light source compared to a reference light source of tungsten halogen. In addition, we suggested the future challenges and standards which are needed to expand usage of LED as a broadcast light source.

Wear Of Resin Composites Polymerized By Conventional Halogen Light Curing And Light Emitting Diodes Curing Units (HALOGEN LIGHT CURING UNIT 과 LIGHT EMITTING DIODES CURING UNIT 을 이용하여 중합되어진 복합레진의 마모 특성 비교)

  • 이권용;김환;박성호;정일영;전승범
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1057-1060
    • /
    • 2004
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15 N contact force in a reciprocal sliding motion with sliding distance of 10 mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji II LC specimen was the greatest among all resin composites. Dyract AP showed the least wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as a curing unit for composite resin restorations.

  • PDF

The Effect of Erythrosine-mediated Photodynamic Therapy on Intraorally Formed Biofilm on Titanium Surface

  • Park, Se-Hwan;Lee, Si-Young;Chang, Beom-Seok;Um, Heung-Sik;Lee, Jae-Kwan
    • International Journal of Oral Biology
    • /
    • v.37 no.3
    • /
    • pp.103-108
    • /
    • 2012
  • The purpose of this study was to assess the efficacy of photodynamic therapy (PDT) using erythrosine and a halogen light source to treat a biofilm formed on a machined surface titanium disk in vivo. Ten volunteers carried an acrylic appliance containing six machined surface titanium disks on the upper jaw over a period of five days. After the five days of biofilm formation period, the disks were removed. PDT using 20 ${\mu}M$ erythrosine and halogen light was then applied to the biofilms formed on the disks. Experimental samples were divided into a negative control group (no erythrosine and no irradiation), E0 group (erythrosine 60s + no irradiation), E30 group (erythrosine 60s + halogen light 30s), and E60 group (erythrosine 60s + halogen light 60s). Following PDT, the bacteria in the biofilm were found to be detached from each disk. Each suspension with detached bacteria were diluted and cultivated on a blood-agar plate for five days under anaerobic conditions. The cultivated bacterial counts in the E60 group were significantly lower than the control group (86.4%) or E0 group (76.7%). In the experimental groups also, the light exposure time and bacterial counts showed a negative correlation. In conclusion, PDT using erythrosine and halogen light has bactericidal effects on biofilms formed on a titanium disk in vivo. Notably, applying 20 ${\mu}M$ erythrosine and 60 seconds of halogen light irradiation had a significantly potent effect.

Wear of Resin Composites Polymerized by Conventional Halogen Light Curing and Light Emitting Diodes Curing Units (Halogen Light Curing Unit과 Light Emitting Diodes Curing Unit을 이용하여 중합되어진 복합레진의 마멸 특성 비교)

  • Lee Kwon-Yong;Kim Hwan;Park Sung-Ho;Jung Il-Young;Jeon Seung-Beom
    • Tribology and Lubricants
    • /
    • v.21 no.6
    • /
    • pp.268-271
    • /
    • 2005
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15N contact force in a reciprocal sliding motion of sliding distance of 10mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji II LC specimen was the greatest among all resin composites. Dyract AP showed less wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as curing unit for composite resin restorations.

Transmitting Ability of Halogen Light in Different Composite Resin Colors (복합레진 색상에 따른 Halogen light의 투과도)

  • Cho, Kyung-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.447-453
    • /
    • 2010
  • The purpose of this study was to compare the light transmitting ability of halogen light in different colors and thicknesses. A1, A2, A3 colors of Z-250 composite resin(3M ESPE, St. Paul, U.S.A.) were used. Degree of conversion of separated resin specimens under the 2, 3, 4mm thickness resin were measured by FTIR spectroscopy. The result shows that decrease of degree of conversion by increase of resin thickness and decrease of degree of conversion by decrease of lightness of color. Within the limitation of results, it is recommended to use more light color of composite resin in small thickness to improve degree of conversion when use halogen light.

Comparison of Radiation Characteristics and Radiant Quantities per unit Electrical Power between High Luminance Light Emitting Diode and Fishing Lamp light Source (고휘도 발광다이오우드와 집어등 광원의 방사특성 및 단위 전력당 방사량 비교)

  • Choi, Sok-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.41 no.6
    • /
    • pp.511-517
    • /
    • 2008
  • The radiation characteristics and economic efficiency of high - luminance light - emitting diodes (LEDs), a metal halide lamp, and a halogen lamp were studied to evaluate their potential as an energy-saving light source for fishing lamps. The wavelengths at which irradiance was maximum were 709, 613, 473, 501, 525, 465, 578, and 973 nm for red, orange, blue, peacock blue, green, and white LEDs, the metal halide lamp, and the halogen lamp, respectively. If the irradiance characteristics at 300-1,100 nm wavelengths are set as 100%, the irradiance rates at 381-780 nm were 99-78%, 82%, and 24% for the LEDs, metal halide lamp, and halogen lamp, respectively. The economic efficiency was superior in the order metal halide lamp, halogen lamp, peacock blue LED, and blue LED at 381-780 nm and metal halide lamp, peacock blue LED, blue LED, and halogen lamp at 480-520 nm. Based on the radiation characteristics and economic efficiency evaluated at 480-520 nm, the blue and peacock blue LED light sources can be used as energy-saving light sources for fishing lamps.

Effects of light direction and exposure times of plasma arc light on shear bond strength of metal brackets (Plasma arc light를 이용한 금속 브라켓의 부착시 광조사 방향과 중합시간이 전단결합강도에 미치는 영향)

  • Roh, Sang-Jeong;Lee, Hyun-Jung;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.429-438
    • /
    • 2004
  • The purpose of this study was to compare the effects of different light direction exposure times and setting times when using plasma arc light on shear bond strength of metal brackets. 240 extracted human premolars were randomly assigned to one of 16 groups Standardized brackets were bonded to enamel using different light curing units (Plasma arc light and Halogen light), exposure times (Plasma arc light 2. 4, 6 seconds and Halogen light 20 seconds). and light directions [Vertical direction [V] and Oblique direction [O]). 8 groups were tested after 5 minutes and the remaining 8 groups after 24 hours. The metal brackets were bonded with Transbond XT. Shear bond strength was measured by a universal testing machine. The results were as fellows: There were as differences between the shear bond strengths of the Vertical groups (V) and Oblique groups (O). regardless of exposure times and types of light curing units (p>0.05). The shear bond strength of the group with 2 seconds of plasma light were significantly lower than other exposure time groups (P<0.05). The shear bond strength tested after 5 minutes was lower than after 24 hours (p<0.05) The Adhesive Remment Index (ARI) score showed no statistically significant difference among the different groups. The results of this study suggested that the light direction of plasma arc light had no influence on the shear bond strength of metal brackets to enamel. and exposure times more than 4 seconds produced shear bond strengths similar to those Produced with a conventional halogen curing light.

POLYMERIZATION ABILITY OF SEVERAL LIGHT CURING SOURCES ON COMPOSITE RESIN (광원에 따른 중합광의 복합레진 중합 능력 비교)

  • Shin, Hye-Jin;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.2
    • /
    • pp.156-161
    • /
    • 2003
  • The purpose of this study is to evaluate the polymerization ability of three different light sources by microhardness test. Stainless steel molds of 1, 2, 3, 4 and 5 mm in thickness of 7 mm in diameter were prepared. The hybrid composite Z100 was packed into the hole of the mold and curing light was activated for designated time. Three different light sources, conventional halogen, light emitting diode, and plasma arc, were used for curing of composite. Two different curing times applied ; one is to follow the manufacturers recommendation and the other is to extend the curing time of LED and plasma arc for balancing the light energy with halogen. Immediately after curing, the Vickers hardness was measured at the bottom of specimen. The results were as follows. 1 The composite cured with LED showed equal to higher microhardnesss than halogen. 2. The composite was cured with plasma arc by manufacturers recommendation showed lowest micro-hardness at all thickness. However, when curing time was extended, microhardness was higher than the others. In conclusion, this study suggested that plasma arc needs properly extended curing time.

COMPARISON OF THE DECREE OF CONVERSION IN LIGHT-CURED COMPOSITE RESIN CURED BY HALOGEN AND PLASMA XENON ARC LAMP CURING UNIT (Halogen lamp 광조사기와 Plasma xenon arc lamp 광조사기에 의한 광중합 복합레진의 중합률 비교)

  • Lee, Young-Jun;Jeong, Byung-Cho;Choi, Nam-Ki;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.328-336
    • /
    • 2002
  • Recently, new light curing unit utilizing the plasma xenon arc lamp is introduced. This curing unit is operated at relatively high intensity, so shortening the curing time significantly. The aim of this experiment was to estimate curing capability of plasma xenon arc lamp curing unit compared to traditional halogen lamp curing unit. Degree of conversion was evaluated by Raman spectroscopy after irradiation of specimens with halogen lamp curing unit(Optilux 150, Demetron, USA) for 20s, 40s, 60s and plasma xenon arc lamp curing unit(flipo, Lokki, France) for 2s, 3s, 6s. The results showed that strong light intensity of plasma xenon arc lamp curing unit did not compensate for short exposure time completely. So, Multi-layered curing within 2mm thickness and additional exposure time is recommanded when light-cured composite resin is polymerized with plasma xenon arc lamp curing unit.

  • PDF

DEVELOPMENT OF OPTICAL CARIES ACTIVITY TEST USING DENTAL CURING LIGHT (광중합기를 이용한 광학적 치아우식활성도 검사법)

  • Lee, Nan-Young;Kim, Mi-Ra;Oh, You-Hyang;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.671-679
    • /
    • 2004
  • The purpose of this study was to develop a practical caries activity test by fluorescence using laser, plasma light and halogen light. The subjects of study were 45 children of 7-8 years old Argon laser, plasma light and halogen light were irradiated to buccal or labial surface of all teeth. Fluorescence of initial carious lesion from teeth was observed through barrier filter and the number of teeth showing lesion was counted. Visual examination for the dDfFtT, mutans streptococci screening test and Lactobacilli colony counting were also done. Data analysis was accomplished by Axelsson's method. The result from the present study can be summarized as follows. 1. Laser, plasma light and halogen light could detect the initial carious lesions better than visual examination(p<0.05). 2. There was positive correlation between laser(r=0.42), plasma light(r=0.41), halogen light(r=0.39) and dBfFtT rate(p<0.01). 3. The specificity sensitivity and predictive value was showed highest value in laser, but was showed favorable value in plasma light and halogen light. In regard to above results, laser, plasma light and halogen light all considered to be reliable method for determining individual caries activity. And they were also considered to be practical method because it would be simple, inexpensive, and time saving method.

  • PDF