• Title/Summary/Keyword: Halogen lamp

Search Result 167, Processing Time 0.031 seconds

A Study on Geosmin Removal of Algae Byproducts by Ozonation and Photocatalysis (오존과 광촉매를 이용한 조류 부산물중 Geosmin 제거에 관한 연구)

  • 김은호;성낙창;최용락
    • Journal of Life Science
    • /
    • v.9 no.5
    • /
    • pp.581-589
    • /
    • 1999
  • This study was carried out to compare ozonation with photocatalysis degradation for removal Geosmin of algae byproduct. The change of pH was decresed from 7.02 to 2.8 after contact time 480 minute for ozonation. In case of UV-germicidal lamp, pH was very quickly increased from 7.02 to 7.5, but Halogen lamp did very slowly change pH. Geosmin degradation ratio was as following, UV-germicidal lamp/TiO2(100mg/L) O3>UV-germicidal lamp/TiO2(50mg/L)>UV-germicidal lamp(10W)>halogen lamp(50W). Instead of TiO2 suspension solution, Geosmin degradation ratio was very low using hollow bead and pellet as coated TiO2. As a result of identifing byproducts, ozonation generated three species of aldehyde such as 3-Heptanone and three species of alcohol such as Heptanal, but photocatalysis formed 1, 14-Tetradecanediol infinitesimally.

  • PDF

A High Dose-rate Gamma Irradiation of the High Brightness Power LED (고휘도 Power LED 의 고선량 감마선 조사 특성)

  • Cho, Jai-Wan;Choi, Young-Soo;Shin, Jung-Cheol
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.243-247
    • /
    • 2009
  • A Radioactive constraint of the nuclear fuel assembly irradiated by neutron during normal operation cycle of the nuclear power plant is typically on the order of about 3 kGy/h. In order to inspect nuclear fuel assembly using a VT (vision technology) system, the light such as halogen lamp is used. As the halogen lamp has lower color temperature than the sun light, the objects under halogen lamp illumination are seemed to be tinted with red. In this paper, high brightness LED is considered to be used as the light source of VT system. The high brightness LED, which is a key light source of the VT system, have been gamma irradiated at the dose rate of 4 kGy/h during two hours up to a total dose of 8 kGy. The radiation induced color-center in the LED housing cap made of plastics materials is observed.

  • PDF

Study on the Performance of Infrared Thermal Imaging Light Source for Detection of Impact Defects in CFRP Composite Sandwich Panels

  • Park, Hee-Sang;Choi, Man-Yong;Kwon, Koo-Ahn;Park, Jeong-Hak;Choi, Won-Jae;Jung, Hyun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.2
    • /
    • pp.91-98
    • /
    • 2017
  • Recently, composite materials have been mainly used in the main wings, ailerons, and fuselages of aircraft and rotor blades of helicopters. Composite materials used in rapid moving structures are subject to impact by hail, lightning, and bird strike. Such an impact can destroy fiber tissues in the composite materials as well as deform the composite materials, resulting in various problems such as weakened rigidity of the composite structure and penetration of water into tiny cracks. In this study, experiments were conducted using a 2 kW halogen lamp which is most frequently used as a light source, a 2 kW near-infrared lamp, which is used for heating to a high temperature, and a 6 kW xenon flash lamp which emits a large amount of energy for a moment. CFRP composite sandwich panels using Nomex honeycomb core were used as the specimens. Experiments were carried out under impact damages of 1, 4 and 8 J. It was found that the detection of defects was fast when the xenon flash lamp was used. The detection of damaged regions was excellent when the halogen lamp was used. Furthermore, the near-infrared lamp is an effective technology for showing the surface of a test object.

A Study on the Risk of Halogen Lamp for Pigsty Heating and Fire Prevention (축사 난방용 할로겐램프의 위험성 및 화재 예방에 관한 연구)

  • Lee, Jae kyung;Seo, Seong Hyeon;Lee, Jae Wook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.553-564
    • /
    • 2021
  • This study analyzed the the risk of halogen lamp for pigsty heating and its fire prevention. Halogen lamps are used for keeping warm in pen because of their excellent economy and convenience. However, there is a high risk of fire due to poor safety management and exposure to animal movements. In fact, after exploring old pigsty and cattle shed, it was easy to confirm that they were exposed to fire risks. We noted this point and studied the possibility of fire by experiment due to combustible contact with halogen lamp and carelessness in use. The experiment was conducted under conditions similar to the actual use environment. After installing halogen lamps to the height used in actual pen, the temperature change was observed with infrared camera with straw, sawdust and rice husks on the floor. And assuming abnormal conditions, the experiment was also conducted under conditions the lamp dropped on the floor or combustible material came into contact with the glass tube inside the lamp. If halogen lamps were used in normal condition, there was no risk of fire. However, in abnormal use environments, smoke comes out or even ignited. Even if it is convenient for use or highly utilized, high risk of fire will require setting up fire prevention measures or regulation of use. Through in-depth fire investigation and research, we should promote the risk of fire and make efforts to prevent fire to minimize human life and property damage.

Novel Ignition Method for Automotive HID lamp Ballast System (자동차 헤드라이트용 고압방전등 안정기 시스템의 새로운 점등방식)

  • Kim, Yoon-Ho;Um, Tae-Wook;Lee, Jae-Hak
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.4
    • /
    • pp.238-243
    • /
    • 2006
  • This paper presents novel ignition method for automotive 35W metal halide discharge lamp electronic ballast. At this study, the novel method of ignition is developed to reduce costs and size of the ballast. By use of the novel method, the voltage needed in ignition is decreased, which result in use of the lower voltage rating power devices compared with conventional method and product compactness was achieved by deleting a circuit generating negative voltage needed in ignition at an conventional circuit. In terms of luminosity, color rendering, light efficiency(lm/W) and lifespan, the metal halide lamp is superior to, but unlike halogen lamp, it have more complicated transient characteristics to reach its steady state than the conventional halogen lamp. Therefore, in this paper, the electronic ballast was designed such that the metal halide lamp could be optimized for the automotive, by applying a method of microcontroller-based digital control. The results of the proposed system is verified through various experiment results.

Determination of an Test Condition for IR Thermography to Inspect a Wall-Thinning Defect in Nuclear Piping Components (원전 배관 감육 결함 검사를 위한 IR 열화상시험 조건 결정)

  • Kim, Jin-Weon;Yun, Won-Kyung;Jung, Hyun-Chul;Kim, Kyeong-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.12-19
    • /
    • 2012
  • This study conducted infrared (IR) thermography tests using pipe and plate specimens with artificial wall-thinning defects to find an optimal condition for IR thermography test on the wall-thinned nuclear piping components. In the experiment halogen lamp was used to heat the specimens. The distance between the specimen and the lamp and the intensity of halogen lamp were regarded as experimental parameter. When the distance was set to 1~2 m and the lamp intensity was above 60 % of full power, a single scanning of IR thermography detected all artificial wall-thinning defects, whose minimum dimension was $2{\Theta}=90^{\circ}$, d/t=0.5, and $L/D_o=0.25$, within the pipe of 500 mm in length. Regardless of the distance between the specimen and the lamp, the image of wall-thinning defect in IR thermography became distinctive as the intensity of halogen lamp increased. The detectability of IR thermography was similar for both plate and pipe specimens, but the optimal test condition for IR thermography depended on the type of specimen.

A Study on the Thermal Characteristics of a 10 cm-diameter substrate for TMR devices by FLA Method (선형가열 법에 따른 TMR 소자용 직경 10cm 기판의 열적 특성에 관한 연구)

  • 송오성;이영민;주영철
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.2
    • /
    • pp.78-83
    • /
    • 2001
  • The thermal characteristics of TMR devices by using Fast Linear Annealing method has been studied. A computer program that employs the finite differential method has been developed to simulate the temperature distribution of a diameter of 4" silicon wafer, which is subjected to radiation heat from the halogen lamp. We adopted the temperature of 350$\^{C}$, which is the highest temperature usually used in annealing for magnetic thin films. We changed moving velocity of the lamp from 0.05 mm/sec to 1 mm/sec. The moving velocity of halogen lamp has less effect on the local peak temperature of the sample only about 40$\^{C}$. Therefore, we may be able to anneal TMR devices in such short time of 1 minute and 40 seconds per one wafer, using the Fast Linear Annealing method.

  • PDF

A Study on the Development of Three Wavelength Solar Bank By Mercury-Halogen Lamps Combination Method (수은-할로겐 램프 조합방식 삼파장 솔라뱅크 개발에 관한 연구)

  • Lee, Jae Myung;Baek, Sang Hwa;Park, So Jin
    • Applied Chemistry for Engineering
    • /
    • v.10 no.8
    • /
    • pp.1147-1154
    • /
    • 1999
  • We developed three-wavelength solar bank which is a very important part of the solar simulator with the commercial mercury lamps and projected halogen lamps. This was developed to satisfy simultaneously following three points: the ${\pm}10%$ uniformity of irradiance of the target area and irradiance in the each wave region and $1120W/m^2$ maximum irradiance of the solar in the summer. We used spectral radiance to determine the standard of the spectral irradiance and developed the perfect three-wavelength solar bank,considering of directionality, irradiance distance, interval both lamps, lamps combination and lamp numbers based on the measured spectral irradiance. To proof the capability of the three wavelength solar bank, We carefully analyzed color differences and heat transfer. As a result, we found that three wavelength solar bank was much better than commercial infrared lamp bank in terms of the color differences, heat transfer phenomena.

  • PDF