• Title/Summary/Keyword: Hall measurement

Search Result 492, Processing Time 0.027 seconds

Investigation of an in-situ measurement method for Sound Strength in concert halls (콘서트홀의 Sound Strength 현장 측정법 고찰)

  • Jeong, Choong-Il;You, Jin;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.987-990
    • /
    • 2007
  • The accuracy of sound strength (G) measurement method in ISO 3382 has been questioned. One of the main reason is the difficulty in measuring a reference sound level in an anechoic chamber with the same set-up which was applied for the actual hall measurements. In the present paper, an in-situ measurement method for G was proposed by investigating the present G measurement method shown in ISO 3382. In addition, the sound radiation characteristics of typical omnidirectional loudspeakers were investigated and Phi (O) of auto correlation function (ACF) parameters was also calculated from an actual music excerpt to characterize the sound energy distribution in concert halls.

  • PDF

Comparison of VOCs Concentration Characteristic According to Measurement Methods in Exhibition Hall (휘발성유기화합물(VOCs)의 측정방법에 따른 유물 전시관 내 농도 분포 특성 비교)

  • Lim, BoA;Lee, Sun Myung
    • 보존과학연구
    • /
    • s.35
    • /
    • pp.25-44
    • /
    • 2014
  • In this study, measured annual year and seasonal concentrations of VOCs by Active type and Passive type using the measurement and analysis method in the exhibition hall and outdoor. It was compared with the correlation between the methods according the comparison of methods to measured concentrations. As a results, the annual average concentrations of TVOC in exhibition room($906.5{\mu}g/m^3$) was greater than for most of the study period, more than 1.8 times the standard in the Ministry of Environment. ${\Sigma}VOCs$ concentration of exhibition room by Active type was higher than Passive type. Some VOCs was decreased with the lapse of time a temporary increase tendencies was. The annual average I/O ratio of TVOC was 9.0, ${\Sigma}VOCs$ was confirmed to occur in a large amount inside the exhibition hall ${\Sigma}VOCs$ was studied to 34.0. Correlation coefficient of ${\Sigma}VOCs$ was 0.367. Toluene was 0.567 that the survey was the largest analysis to the relationship between the two methods.

  • PDF

Measurement of a Blood Velocity by using Photoplethysmograph and Radial Artery Pulse Wave Equipped with Magnetic Hall Device (자성 홀소자 맥진기와 용적맥파계의 맥진파형을 이용한 혈류속도 측정 연구)

  • Jang, Deok-Hyeong;Kim, Dam-Bee;Choi, Suel-Gi;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.4
    • /
    • pp.130-135
    • /
    • 2012
  • One prototype product of clip-type pulsimeter equipped with magnetic field sensing semiconductor Hall device after one permanent magnet attached "Chwan" position in center of a radial artery was developed. The clip-pulsimeter was composed of the hard ware system measuring to voltage signals. To measure the blood velocity, the radial artery pulsimeter is simultaneously connected the PPG (photoplethysmograph). Analysis and comparison of two pulse waves data has done obtained from a clinical test of forty subjects of 20 ages. The value of a blood velocity simultaneously measured from a radial artery puls wave and PPG is an average value of 0.8m/s. The usage of this research results is possible to store the biomedical signals for health care.

A pin type current probe using Planar Hall Resistance magnetic sensor (PHR 자기센서를 적용한 탐침형 전류 프로브)

  • Lee, Dae-Sung;Lee, Nam-Young;Hong, Sung-Min;Kim, CheolGi
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.342-348
    • /
    • 2021
  • For the characterization or failure analysis of electronic devices such as PCB (printed circuit boards), the most common method is the measurement of voltage waveforms with an oscilloscope. However, because there are many types of problems that cannot be detected by voltage waveform analysis, several other methods such as X-ray transmission, infrared imaging, or eddy current measurement have been applied for these analyses. However, these methods have also been limited to general analyses because they are partially useful in detecting physical defects, such as disconnections or short circuits. Fundamentally current waveform measurements during the operation of electronic devices need to be performed, however, commercially available current sensors have not yet been developed, particularly for applications in highly integrated PCB products with sub-millimeter fine pitch. In this study, we developed a highly sensitive PHR (planar hall resistance) magnetic sensor for application in highly integrated PCBs. The developed magnetic sensor exhibited sufficient features of an ultra-small size of less than 340 ㎛, magnetic field resolution of 10 nT, and current resolution of 1 mA, which can be applicable for PCB analyses. In this work, we introduce the development process of the magnetic sensing probe and its characteristic results in detail, and aim to extend this pin-type current probe to applications such as current distribution imaging of PCBs.

Influence of sputtering pressure on structural and electrical properties of molybdenum thin film for solar cell application (태양전지용 Mo 박막의 스퍼터 압력에 따른 구조적, 전기적 특성의 변화)

  • Kim, Joong-gyu;Lee, Su-ho;Lee, Jae-hyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.786-788
    • /
    • 2013
  • Molybdenum (Mo) thin film has high electrical conductivity and has been used for a back contact of CIGS thin film solar cell. Generally, the electrical conductivity and the adhesion between the substrate and the film is greatly affected by sputtering conditions such as sputtering power, working pressure, and substrate temperature. In this study, Mo films were deposited by DC magnetron sputtering technique. The influence of sputtering pressure on the electrical and structural properties of Mo films was investigated by using SEM(scanning electron microscope), XRD(X-ray Diffraction), 4-point probe, Reflectance, Hall measurement.

  • PDF

Magnetic Measurement of PLS Storage Ring Prototype Dipole Magnet (방사광 가속기용 2극 전자석 특성측정 및 보정)

  • 강봉구;박기현;윤종렬;구양모
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.2
    • /
    • pp.163-168
    • /
    • 1992
  • Results of magnetic measurement of a prototype Storage Ring dipole magnet for the Pohang Light Source (PLS) are summarized. Hall probe mapping and rotating coil methods are used to measure field profiles and integrated field properties. End chamfering experiments are performed on the as-built magnet, which has four removable pole-end pieces, to meet the specifications set from beam dy-namics requirement. The corrected magnet has efficiency of 99.7% at 2.0 GeV excitation ad higher order multipole error levels less than the specifications for all excitations, showing that the magnet has appropriate properties for the PLS Storage Ring.

  • PDF

A Study on the Fabrication and Characteristics of ITO thin Film Deposited by the Ionized Cluster Beam Deposition (Ionized Cluster Beam 증착방법을 이용한 Indium-Tin-Oxide(ITO) 박막의 제작과 그 특성에 관한 연구)

  • 최성창;황보상우;조만호;김남영;홍창의;이덕형;심태언;황정남
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.1
    • /
    • pp.54-61
    • /
    • 1996
  • Indium-tin oxide (ITO) films were deposited on the glass substrate by the reactive -ionized cluster beam deposition(ICBD) method. In the oxygen atmosphere, indium cluster formed through the nozzle is ionized by the electron bombardment and is accelerated to be deposited on the substrate. And tin is simultaneoulsy evaporated from the boron-nitride crucible. The chracteristics of films were examined by the X-ray photoelectron spectroscopy(XPS), glancing angle X-ray diffractrion(GXRD) and the electrical properties. were measured by 4-point-probe and Hall effect measurement system . From the XPS spectrum , it was found that indium and tin atoms combined with the oxygen to form oxide$(In_2O_3, SnO_2)$. In the case of films with high tin-concentration, the GXRD spectra show that the main $In_2O_3$ peak of (222) plane, but also sub peaks((440) peak etc.) and $SnO_2$ peaks were detected. From that results, itis concluded that the heavily dopped tin component (more than 14 at. %) disturbs to form $In_2O_3$(222) phase. Four-point-probe and Hall effect measurement show that, in the most desirable case, the transmittance of the films is more then 90% in visible range and its resistivity is $$\rho$=3.55 \times10^{-4}\Omega$cm and its mobility is $\mu$=42.8 $\textrm{cm}^2$/Vsec.

  • PDF

Structural and electrical properties of high temperature deposited epitaxial ZnO thin film by RF magentron sputtering (RF 마그네트론 스퍼터일 법으로 증착된 에피택셜 ZnO 박막의 구조적, 전기적 특성)

  • Kim, Dong-Hun;Cho, Nam-Gyu;Park, Hun;Kim, Ho-Gi
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.184-185
    • /
    • 2007
  • We investigated the growth behaviors of ZnO epilayers on sapphire substrates fabricated sing RF magnetron puttering and RTA. The effects of deposition temperature and oxygen partial pressure in plasma on the structural and electrical properties were measured by XRD, AFM, SEM, and Hall effect measurement. It was found that ZnO thin films became denser and smoother with increasing deposition temperature and $O_2$ content in the puttering gas. ZnO thin film of oxygen and argon with a ratio of 5:5 had an electron concentration of $8.048{\times}10^{18}cm^{-3}$, resistivity of $0.0141{\Omega}{\cdot}Cm$, and mobility of $55.07cm^2/V{\cdot}s$.

  • PDF

Measurement and Analysis of Pulse Wave using Clip Type Pulsimeter Equipped with a Permanent Magnet and a Hall Device (영구자석과 홀소자로 구비된 집게형 맥진기를 이용한 맥진파형 측정과 분석)

  • Son, Il-Ho;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.3
    • /
    • pp.104-107
    • /
    • 2011
  • We measured signals at the "Guan" region of a radially arterial pulse using the prototype of a clamping pulsimeter equipped with a Hall effect device, which is passed signals through the voltage detecting hard ware system. The important four different measuring times of the period, systolic, reflective, and notch peaks for a temporally pulse signal are obtained and compared each other from the analysis for an arbitrary pulse wave of one position of small size permanent magnet. It is possible to measure the reproducible pulse rate and blood pressure by using the cuffless clip type pulsimeter without an unpleasant oppressive feeling due to the use of pressurization.

The Electrical Characterization of the Quantized Hall Device with GaAs/AlGaAs heterojunction structure (GaAs/AlGaAs 이종접합된 양자흘 소자의 전기적 특성)

  • 유광민;류제천;한권수;서경철;임국형
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.334-337
    • /
    • 2002
  • The Quantum Hall Resistance(QHR) device which consists of GaAs/AlGaAs heterojunction structure is used for the realization of QHR Standard based on QHE. In order to characterize electrical contact resistances and dissipations of the device, it is slowly cooled down for eliminating thermal shock and unwanted noise. Then, the two properties are measured under 1.5 K and 5.15 T. Contact resistances are all within 1.2 Ω and longitudinal resistivities are all within 1 mΩ up to DC 90${\mu}$A. The results mean the device is operated well to realize the QHR Standard. To confirm it, the QHR Standard having the device is compared using a direct current comparator bridge with a 1 Ω resistance standard which the calibrated value is known from QHR standards maintained by other countries. The difference between them is agreed well within measurement uncertainty. It is thus considered that the properties of the device is estimated well and has good performance.

  • PDF