• Title/Summary/Keyword: Half-Width

Search Result 918, Processing Time 0.04 seconds

A Style Study for Reissued Gongsin-Gyoseo in Joseon Dynasty (조선시대 재발급(再發給) 공신교서(功臣敎書) 양식 연구)

  • Sim, Young-hwan;Lee, Jin-hee
    • Korean Journal of Heritage: History & Science
    • /
    • v.47 no.2
    • /
    • pp.4-19
    • /
    • 2014
  • In Joseon dynasty, Gongsin-Gyoseo(Royal Edicts rewarding meritorious vassals) was issued for the reward of the contribution to the specific event of the nation. The family decided as vassals succeeded this Gongsin-Gyoseo as the family treasure to later generations. When one happened to lose this caused by an unavoidable situation such as war in this process, there were a few cases of reissuing of Gongsin-gyoseo by the nation. The confirmative reissued Gongsin-gyoseo among Gongsin-gyoseo that descended down by now are three pieces which is Park dongnyang Hoseong Gongsin-Gyoseo, Gu goeng Jeongsa Gongsin-Gyoseo, and Park jung Jeongsa Gongsin-Gyoseo. This research considered the form and mounting about these three pieces. It was indicated that the reissued Gongsin-Gyoseo was produced following the same form with the original Gongsin-Gyoseo, that is pyeongchul(moving to next lines) and daedu (writing one or two letters ahead compared to the first letter) and so on. But, it was indicated that the change of the position of the vassals in the reissued time was reflected compared to position of the original Gongsin-Gyoseo. In case of Jeonsa Gongsin-Gyoseo, it was indicated that it was 'Wonjongdaewang-whi' since the original Gongsin-Gyoseo was 'Jeongwongun-bu' and the reissued time he became the father of King Injo. Also, it was confirmed that the case of deprivation because of conspiracy such as 'Kim jajeom, Kim ryeon, Sim kiwon, Sim kisung' was produced as the original document and deleted with black ink stick. It was newly confirmed while the original Gongsin-Gyoseo was produced by a designated writer from the nation, the reissuance was written by a writer from the family of the vassals. Since the mounting of Gongsin-Gyoseo could be changed according to the favor and technique of the craftsman participated in the practical production such as Baezeopjang and economical situation of the country supplying the material, the mounting of these three Gongsin-Gyoseo should be different from the original mounting, especially because of the loss of the original by the Manchu war of 1636. The comparison result of Gongsin-Gyoseo produced in the same period with the original issued one in the record of the related Uigwe (a collection of documents from the Joseon Dynasty), the reissued one seems to be larger in the form or ratio of the mounting compared to the first issued one. First of all, the width of Byunah was expanded as twice bigger, center and both side Hoejang also was bigger as over 2cm, and the below Hoejang was expanded as 10cm, and the ratio of the upper Hoejang and the below Hoejang was wider as 1.5 times and the reissuance was 1:1 ratio. The bisect of upper shaft in Park dongnyang Hoseong Gongsin-Gyoseo is assumed as the form of an equilateral triangle, not a half-moon shape of the present, and Gu goeng and Park jung Jeongsa Gongsin-Gyoseo will be the form whose bisection form is same but the size is smaller. Chuksu is confirmed that the size is not changed significantly. Osaekdahoe can be assumed that the width was smaller compared to the first issued one. The 3 pieces of the reissued versions provide the clue of the verification for the form of the mounting of Bosa Gongsin-Gyoseo in the same production period. In the situation that the mounting of the production time was not confirmed among the currently descended Bosa Gongsin-Gyoseo, they can be very important materials.

Usability of Multiple Confocal SPECT SYSTEM in the Myocardial Perfusion SPECT Using $^{99m}Tc$ ($^{99m}Tc$을 이용한 심근 관류 SPECT에서 Multiple Confocal SPECT System의 유용성)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.65-71
    • /
    • 2011
  • Purpose: The recently adopted multiple confocal SPECT SYSTEM (hereinafter called IQ SPECT$^{TM}$) has a high difference from the conventional myocardial perfusion SPECT in the collimator form, image capture method, and image reconstruction method. This study was conducted to compare this novice equipment with the conventional one to design a protocol meeting the IQ SPECT, and also determine the characteristics and usefulness of IQ SPECT. Materials and Methods: 1. For the objects of LEHR (Low energy high resolution) collimator and Multiple confocal collimator, $^{99m}Tc$ 37MBq was put in the acrylic dish then each sensitivity ($cpm/{\mu}Ci$) was measured at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. 2. Based on the sensitivity measure results, IQ SPECT Protocol was designed according to the conventional general myocardial SPECT, then respectively 278 kBq/mL, 7.4 kBq/mL, and 48 kBq/mL of $^{99m}Tc$ were injected into the myocardial and soft tissues and liver site by using the anthropomorphic torso phantom then the myocardial perfusion SPECT was run. 3. For the comparison of FWHMs (Full Width at Half Maximum) resulted from the image reconstruction of LEHR collimator, the FWHMs (mm) were measured with only algorithms changed, in the case of the FBP (Filtered Back projection) method- a reconstruction method of conventional myocardial perfusion SPECT, and the 3D OSEM (Ordered subsets expectation maximization) method of IQ SPECT, by using $^{99m}Tc$ Line source. Results: 1. The values of IQ SPECT collimator sensitivity ($cpm/{\mu}Ci$) were 302, 382, 655, 816, 1178, and those of LEHR collimator were measured as 204, 204, 202, 201, 198, both at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. It was found the difference of sensitivity increases up to 4 times at the distance of 30 cm in the cases of IQ SPECT and LEHR. 2. The myocardial perfusion SPECT Protocol was designed according to the geometric characteristics of IQ SPECT based on the sensitivity results, then the phantom test for the aforesaid protocol was conducted. As a result, it was found the examination time can be reduced 1/4 compared to the past. 3. In the comparison of FWHMs according to the reconstructed algorithm in the FBP method and 3D OSEM method followed after the SEPCT test using a LEHR collimator, the result was obtained that FWHM rose around twice in the 3D OSEM method. Conclusion : The IQ SPECT uses the Multiple confocal collimator for the myocardial perfusion SPECT to enhance the sensitivity and also reduces examination time and contributes to improvement of visual screen quality through the myocardial-specific geometric image capture method and image reconstruction method. Due to such benefits, it is expected patients will receive more comfortable and more accurate examinations and it is considered a further study is required using additional clinical materials.

  • PDF

Preliminary Study for Imaging of Therapy Region from Boron Neutron Capture Therapy (붕소 중성자 포획 치료에서 치료 영역 영상화를 위한 예비 연구)

  • Jung, Joo-Young;Yoon, Do-Kun;Han, Seong-Min;Jang, HongSeok;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.151-156
    • /
    • 2014
  • The purpose of this study was to confirm the feasibility of imaging of therapy region from the boron neutron capture therapy (BNCT) using the measurement of the prompt gamma ray depending on the neutron flux. Through the Monte Carlo simulation, we performed the verification of physical phenomena from the BNCT; (1) the effects of neutron according to the existence of boron uptake region (BUR), (2) the internal and external measurement of prompt gamma ray dose, (3) the energy spectrum by the prompt gamma ray. All simulation results were deducted using the Monte Carlo n-particle extended (MCNPX, Ver.2.6.0, Los Alamos National Laboratory, Los Alamos, NM, USA) simulation tool. The virtual water phantom, thermal neutron source, and BURs were simulated using the MCNPX. The energy of the thermal neutron source was defined as below 1 eV with 2,000,000 n/sec flux. The prompt gamma ray was measured with the direction of beam path in the water phantom. The detector material was defined as the lutetium-yttrium oxyorthosilicate (Lu0,6Y1,4Si0,5:Ce; LYSO) scintillator with lead shielding for the collimation. The BUR's height was 5 cm with the 28 frames (bin: 0.18 cm) for the dose calculation. The neutron flux was decreased dramatically at the shallow region of BUR. In addition, the dose of prompt gamma ray was confirmed at the 9 cm depth from water surface, which is the start point of the BUR. In the energy spectrum, the prompt gamma ray peak of the 478 keV was appeared clearly with full width at half maximum (FWHM) of the 41 keV (energy resolution: 8.5%). In conclusion, the therapy region can be monitored by the gamma camera and single photon emission computed tomography (SPECT) using the measurement of the prompt gamma ray during the BNCT.

A study of the arch length discrepancy and the diagnostic analysis (치열궁내 공간 부조화와 진단적 평가에 관한 연구)

  • Ryu, Young-Kyu;Ahn, Kwang-Seok
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.1-11
    • /
    • 2004
  • Predicting the arch length discrepancy by simply comparing the available arch perimeter with tooth materials is merely a 2-dimensional analysis of the teeth movement. However, the real teeth movement takes place 3-dimensionally and is affected by various factors such as, the arch fen the curve of Spee and the axis of the incisors. The purpose of this study is to clarify the relationship between the decrease in the arch perimeter and the horizontal positional change of the incisors after extraction of the 1st bicuspids, for more analytic evaluation of the arch length discrepancy at pre-treatment model analysis stage. In addition to that to evaluate the effect of the curve of Spee, teeth axis to the basal plane, and the incisional crowding to the treatment outcome. All patients were treated at the department of orthodontics, dental hospital, Yonsei university. Inclusion criteria for patients selection were as follows. $\cdot$ Angle classification I malocclusion with bialveolar protrusion $\cdot$ Extraction of 4 1st bicuspids $\cdot$ No tooth anomaly or prosthesis $\cdot$ No abnormal attrition $\cdot$ No ectopically erupted teeth $\cdot$ Angle classification I canine and molar relationship $\cdot$ Less than 3mm of crowding Model analysis of the above patients was performed and the following conclusions were obtained. 1. When the intercanine distance was maintained, the available space for the distal movement of the mandibular incisors after the extraction of the 4 1st bicuspids was larger than the space provided by the extraction of the 4 1st bicuspids. However the difference was less than 1mm. The more tapered the anterior arch form, the larger the difference. 2. Compared to the situation in which the intercanine distance was maintained, when the intercanine distance was expanded to meet the width of the Posterior teeth, the incisors could move about 3mm more distally. 3. The positional difference of the incisal tip was insignificant whether the central incisors were moved by tipping or bodily movement. 4. When the anterior crowding was solved without changing the intercanine distance, the larger the anterior arch length was, the more the anterior movement of the incisors. 5. When the curve of Spee was levelled, the increase in the arch perimeter was less than half of the deepest curve of Spee.

Spatial Variability Analysis of Rice Yield and Grain Moisture Contents (벼 수확량 및 곡물 수분함량의 공간변이 해석)

  • Chung, Ji-Hoon;Lee, Ho-Jin;Lee, Seung-Hun;Yi, Chang-Hwan
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.54 no.2
    • /
    • pp.203-209
    • /
    • 2009
  • Yield monitoring is one of a precision agriculture technology that is used most widely. It is spatial variability analysis of yield information that should be attained with yield monitoring system development. This experiment was conducted to evaluate spatial variability of yield and grain moisture content in rice paddy field, and their relationships to rice productivity. It is necessary to minimize sampling interval for accurate yield map making or to control cutting width of rice combine. Considering small rice plots such as $0.2{\sim}0.4$ ha, optimum size of sampling plot was below 15 m more than 5 m in with and length. In variable rate treatment field, average yield was similar, but yield variation was reduced than conventional field. Gap of yield by another plot in same field was bigger than half of average yield than yield variation was significantly big. Therefore yield measuring flow sensor must be able to measure at least 300 kg/10a more than 1000 kg/10a. Variation of moisture content in same field was not big and spatial dependance did not appear greatly. But, variation between different field is appeared difference according to weather circumstance before harvesting. Change of spatial dependence of yield was not big, because of field variation of moisture content is not big.

Evaluation of SharpIR Reconstruction Method in PET/CT (PET/CT 검사에서 SharpIR 재구성 방법의 평가)

  • Kim, Jung-Yul;Kang, Chun-Koo;Park, Hoon-Hee;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose : In conventional PET image reconstruction, iterative reconstruction methods such as OSEM (Ordered Subsets Expectation Maximization) have now generally replaced traditional analytic methods such as filtered back-projection. This includes improvements in components of the system model geometry, fully 3D scatter and low noise randoms estimates. SharpIR algorithm is to improve PET image contrast to noise by incorporating information about the PET detector response into the 3D iterative reconstruction algorithm. The aim of this study is evaluation of SharpIR reconstruction method in PET/CT. Materials and Methods: For the measurement of detector response for the spatial resolution, a capillary tube was filled with FDG and scanned at varying distances from the iso-center (5, 10, 15, 20 cm). To measure image quality for contrast recovery, the NEMA IEC body phantom (Data Spectrum Corporation, Hillsborough, NC) with diameters of 1, 13, 17 and 22 for simulating hot and 28 and 37 mm for simulating cold lesions. A solution of 5.4 kBq/mL of $^{18}F$-FDG in water was used as a radioactive background obtaining a lesion of background ratio of 4.0. Images were reconstructed with VUE point HD and VUE point HD using SharpIR reconstruction algorithm. For the clinical evaluation, a whole body FDG scan acquired and to demonstrate contrast recovery, ROIs were drawn on a metabolic hot spot and also on a uniform region of the liver. Images were reconstructed with function of varying iteration number (1~10). Results: The result of increases axial distance from iso-center, full width at half maximum (FWHM) is also increasing in VUE point HD reconstruction image. Even showed an increasing distances constant FWHM. VUE point HD with SharpIR than VUE point HD showed improves contrast recovery in phantom and clinical study. Conclusion: By incorporating more information about the detector system response, the SharpIR algorithm improves the accuracy of underlying model used in VUE point HD. SharpIR algorithm improve spatial resolution for a line source in air, and improves contrast recovery at equivalent noise levels in phantoms and clinical studies. Therefore, SharpIR algorithm can be applied as through a longitudinal study will be useful in clinical.

  • PDF

Evaluation of MR Based Respiratory Motion Correction Technique in Liver PET/MRI Study (Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • Purpose Respiratory motion during PET/MRI acquisition may result in image blurring and error in measurement for volume and quantification of lesion. The aim of this study was to evaluate changes of quantitative accuracy, tumor size and image quality by applying MR based respiratory motion correction technique (MBRMCT) using integrated PET/MR scanner. Materials and Methods Data of 30 patients (aged $62.5{\pm}10.2y$) underwent $^{18}F-FDG$ liver PET/MR (Biograph mMR 3.0T, Siemens) study were collected. PET listmode data for 7 minutes was simultaneously acquired with maximum average gate (MAG), minimum time gate (MTG) and non gate (NG) T1 weighted MR images. Gated PET reconstruction was performed using mu-maps generated from MAG and MTG by setting 35% of efficiency window. Maximum SUV ($SUV_{max}$), peak SUV ($SUV_{peak}$), tumor size and full width at half maximum (FWHM) in the z-axis direction of MAG, MTG and NG PET images were evaluated. Results Compared to NG, mean $SUV_{max}$ and $SUV_{peak}$ were increased in MAG 13.15%(p<0.0001), 8.66%(p<0.0001), MTG 13.27%(p<0.0001), 8.80%(p<0.0001) and mean tumor size and FWHM were decreased in MAG 14.47%(p<0.0001), 15.49%(p=0.0004), MTG 14.89%(p<0.0001), 15.79%(p=0.0003) respectively. Mean $SUV_{max}$ and $SUV_{peak}$ of MTG were increased by 0.07%(p=0.8802), 0.13%(p=0.7766). Mean tumor size and FWHM of MTG were decreased by 0.49%(p=0.2786), 0.36%(p=0.2488) compared to MAG. There was no statistically significant difference between MAG and MTG which increase total scan time for about 7 and 2 minutes. Conclusion SUV, accuracy of tumor size and spatial resolution were improved in both of MAG and MTG by applying MBRMCT without installing additional hardware in liver PET/MR study. More accurate information can be provided with the increase of 2 minutes scan time if applying MTG of MBRMCT to various abdominal PET/MR studies affected by respiratory motion.

MR-based Partial Volume Correction Using Hoffman Brain Phantom Data and Clinical Application (자기공명영상을 이용한 양전자방출단층촬영의 부분용적효과 보정 및 임상적용)

  • 김동현;이상호;정해조;윤미진;이종두;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.203-210
    • /
    • 2003
  • PET (positron emission tomography) permits the investigation of physiological and biochemical processes in vivo. The accuracy of quantifying PET data is affected by its finite spatial resolution, which causes partial volume effects. In this study, we developed a method for partial volume correction using Hoffman phantom PET and MR data, and applied various FWHM (full width at half maximum) levels. We also applied this method to PET images of normal controls and tested for the possibility of clinical application. $^{18}$ F-PET Hoffman phantom images were co-registered to MR slices. The gray matter and white matter regions were then segmented into binary images. Each binary image was convolved by 4, 8, 12, 16 mm FWHM levels. These convolved images of gray and white matter were merged corresponding to the same level of FWHM. The original PET images were then divided by the convolved binary images voxel-by-voxel. These corrected PET images were multiplied by binary images. The corrected PET images were evaluated by analyzing regions of interests, which were drawn on the gray and white matter regions of the original MR image slices. We calculated the ratio of white to gray matter. We also applied this method to the PET images of normal controls. On analyzing the corrected PET images of Hoffman phantom, the ratios of the corrected images increased more than that of the uncorrected images. With the normal controls, the ratio of the corrected images increased more than that of the uncorrected images. The ratio increase of the corrected PET images was lower than that of the corrected phantom PET images. In conclusion, the method developed for partial volume correction in PET data may be clinically applied, although further study may be required for optimal correction.

  • PDF

Growth and characterization ofZnIn$_2S_4$ single crystal thin film using hot wall epitaxy method (Hot Wall Epitaxy(HWE)에 의한 ZnIn$_2S_4$ 단결정 박막 성장과 특성)

  • 최승평;홍광준
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.11 no.4
    • /
    • pp.138-147
    • /
    • 2001
  • The stochiometric mixtures mixture of evaporating materials for the $ZnIn_{2}S_{4}$ single crystal thin film was prepared from horizontal furnace. To obtain the $ZnIn_{2}S_{4}$ single crystal thin film, $ZnIn_{2}S_{4}$ mixed crystal was deposited on throughly etched semi-insulting GaAs(100) in the Hot Wall Epitaxy(HWE) system. The sourceand substrate temperature were $610^{\circ}C$ and $450^{\circ}C$, respectively and the growth rate of the $ZnIn_{2}S_{4}$ single crystal thin film was about 0.5$\mu\textrm{m}$/hr. The crystalline structure of $ZnIn_{2}S_{4}$ single crystal thin film was investigated by photoluminescence and double crystal X-ray diffraction (DCXD) measurement. The carrier density and mobility of $ZnIn_{2}S_{4}$ single crystal thin film measured from Hal effect by van der Pauw method are $8.51{\times}10^{17}{\textrm}{cm}^{-3}$, 291$\textrm{cm}^2$/V.s at $293^{\circ}$K, respectively. From the photocurrent spectrum by illumination of perpendicular light on the c-axis of the $ZnIn_{2}S_{4}$ single crystal thin film, we have found that the values of spin orbit splitting $\Delta$So and the crystal filed splitting DCr were 0.0148eV and 0.1678 eV at $10^{\circ}$K, respectively. From the photoluminescence measurement of $ZnIn_{2}S_{4}$ single crystal thin film, we observed free excition($E_{X}$) typically observed only in high quality crystal and neutral donor bound exicton ($D^{\circ}$, X) having very strong peak intensity. The full width at half maximum and binding energy of neutral donor bound excition were 9meV and 26meV, respectively. The activation energy of impurity measured by Haynes rule was 130meV.

  • PDF

Energy band gap of $Zn_{0.86}Mn_{0.14}Te$ epilayer grown on GaAs(100) substrates (GaAs(100)기판 위에 성장된 $Zn_{0.86}Mn_{0.14}Te$에피막의 띠 간격 에너지)

  • 최용대;안갑수;이광재;김성구;심석주;윤희중;유영문;김대중;정양준
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.3
    • /
    • pp.122-126
    • /
    • 2003
  • In this study, $Zn_{0.86}Mn_{0.14}$Te epilayer of 0.7 $\mu\textrm{m}$-thickness was grown on GaAs(100) substrate by using hot wallepitaxy. GaAs(100) substrate was removed from $Zn_{0.86}Mn_{0.14}$Teepilayer by the selective etching solution. The crystal structure and the lattice constant of only Z $n_{0.86}$ M $n_{0.14}$Te epilayer were investigated to be zincblende and 6.140 $\AA$ from X-ray diffraction pattern, respectively. Mn composition x of $Zn_{1-x}Mn_x$Te epilayer was found to be 0.14 using this lattice constant and Vegard's law. The crystal quality of the epilayer was confirmed to be very good due to 256 arcsec-full-width at half-maximum of the double crystal rocking curve. The absorption spectra from the transmission ones were obtained to measure the band gap energy of $Zn_{0.86}Mn_{0.14}$Te epilayer from 300 K to 10 K. With the decreasing temperature,. strong absorption regions in the absorption spectra were shifted to higher energy side and the absorption peak meaning the free exciton formation appeared near the absorption edge. The band gap energy values of $Zn_{0.86}Mn_{0.14}$Te epilayer at 0 K and 300 K were found to be almost 2.4947 eV and 2.330 eV from the temperature dependence of the free exciton peak position energy of $Zn_{0.86}Mn_{0.14}$Te epilayer, respectively. The free exciton peak position energy of $Zn_{0.86}Mn_{0.14}$Te epilayer without GaAs substrate was larger 15.4 meV than photoluminescence peak position energy at 10 K. This energy difference between two peaks was analysed to be Stokes shift.