• Title/Summary/Keyword: Half-Width

Search Result 914, Processing Time 0.032 seconds

Genetic Relationship between Seed size and Leaf Size in 66 $F_2$ Populations Derived from Mating of 12 Soybean Strains (대두 12 모본의 half diallel cross로부터 생성된 66 $F_2$ 분리집단에서의 종자크기와 잎 크기에 대한 관계)

  • 정종일
    • Journal of Life Science
    • /
    • v.8 no.4
    • /
    • pp.437-442
    • /
    • 1998
  • Seed and leaf size is the important morphological traits considered by plant breeder and is the important yield components in soybean. The objective of this research was to know the relationship between seed size and leaf size in 66 $F_2$ populations derived from half diallel mating system with 12 soybean strains, representing distinct seed and leaf size. The range of seed size for 12 parents used was 6.7 to 43.8 g/100 seed. Leaf width leaf length ranged 5.7 to 8.6 cm and 9.4 to 12.9 cm, respectively. Leaf width was highly correlated with leaf length with an R square of 0.754 in the $F_2$ generation. The $F_2$ regression` coefficient indicated that leaves were, on average 1.4 times greater length than in width . Leaf size (width) was highly correlated (r.0.91) with seed size (g/100 seed) in the $F_2$ generation with an R square of 0.833. Our results indicate postive correlation within seed and leaf size is common in $F_2$ segregating populations derived from crossing with soybean. The strong liner relationship we observed between leaf size and seed size in $F_2$ segragating population is useful in that in that indirect selection for a secondary character may be superior to direct selection for the primary character.

  • PDF

Optimal Shape Design of Dual Reflector Antenna Based on Genetic Algorithm (유전 알고리즘 기반의 이중 반사경 안테나 형상최적화 기법)

  • Park, Jung-Geun;Chung, Young-Seek;Kang, Won-June;Shin, Jin-Woo;So, Joon-Ho;Cheon, Chang-Yul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.5
    • /
    • pp.445-454
    • /
    • 2015
  • In this paper, we propose an optimal design method for a dual reflector antenna(DRA) using the Genetic algorithm. In order to reduce the computational burden during the optimal design, we exploit the iterative physical optics(IPO) to calculate the surface current distribution at each reflector antenna. To improve the accuracy, we consider the shadow effect by the structure and the coupling effect by the multi-reflection based on the iterative MFIE(Magnetic Field Integral Equation). To reduce the number of design variables and generate a smooth surface, we use the Bezier function with the control points, which become the design variables in this paper. We adopt the HPBW(Half Power Beam Width), the FNBW(First Null Beam Width), and the SLL(Side Lobe Level) as the objective or cost functions. To verify the results, we compare them with the those of the commercial tool.

A Study on Examining the Calculation Including the Ease Amount for Bodice Pattern (여유량이 포함된 제도식 검증에 관한 연구-길원형을 중심으로)

  • Koo, Mi-ji
    • The Journal of Natural Sciences
    • /
    • v.9 no.1
    • /
    • pp.105-112
    • /
    • 1997
  • This study was carried out to examine the calculations including the ease amount for bodice pattern. The conclusions were as follows. The areas that were required the ease amount were the horizontal reference line, armhole depth, back & front width. According to this result the calculations including the ease amount were obtained as follows: B/2+4.1cm for horizontal reference line, B/6+6.8 cm for armhole depth, B/6+3.9 cm for the half of back width, B/6+2.3 cm for the half of front width, B/4+4.3 cm for bust point length.

  • PDF

Morphologic and Genetic Evidence for Mixed Infection with Two Myxobolus Species (Myxozoa: Myxobolidae) in Gray Mullets, Mugil cephalus, from Korean Waters

  • Kim, Wi-Sik;Kim, Jeong-Ho;Oh, Myung-Joo
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.3
    • /
    • pp.369-373
    • /
    • 2013
  • The present study was performed to trace the decisive evidence for mixed infection of 2 Myxobolus species, M. episquamalis and Myxobolus sp., in the gray mullet, Mugil cephalus, from Korean waters. Mullets with whitish cyst-like plasmodia on their scales were collected near a sewage plant in Yeosu, southern part of Korea, in 2009. The cysts were mainly located on scales and also found in the intestine. The spores from scales were oval in a frontal view, tapering anteriorly to a blunt apex, and measured $7.2{\mu}m$ (5.8-8.0) in length and $5.3{\mu}m$ (4.7-6.1) in width. Two polar capsules were pyriform and extended over the anterior half of the spore, measuring $3.5{\mu}m$ (2.3-4.8) in length and $2.0{\mu}m$ (1.5-2.2) in width. In contrast, the spores from the intestine were ellipsoidal, $10.4{\mu}m$ (9.0-11.9) in length and $8.4{\mu}m$ (7.3-10.1) in width. The polar capsules were pyriform but did not extend over the anterior half of the spore, $3.7{\mu}m$ (2.5-4.5) in length and $2.2{\mu}m$ (1.8-2.9) in width. The nucleotide sequences of the 18S rDNA gene of the 2 myxosporean spores from scales and intestine showed 88.1% identity to each other and 100% identity with M. episquamalis and 94.5% identity with M. spinacurvatura from mullet, respectively. By the above findings, it is first confirmed that mullets from the Korean water are infected with 2 myxosporean species, M. episquamalis and Myxobolus sp.

Fatigue Safety Evaluation of the Half-Depth Precast Deck with RC Rib Panel (리브 형상을 갖는 반단면 프리캐스트 바닥판의 피로 안전성 평가)

  • Hwang, Hoon Hee
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.103-110
    • /
    • 2019
  • In order to reduce the accidents occurring at construction sites, it is necessary to approach with harmonious measures considering various aspects such as systems, training, facilities, and protection equipments. Suggestion of safe construction method can be a good alternative. In the previous study, the half-depth precast deck with RC rib panel was proposed as an alternative method for safe bridge deck construction, and the performance required by the design code was verified through a four-point bending test. But the actual bridge deck is subjected to the repetitive action of the wheel load rather than the bending condition due to the four-point load. In this study, fatigue test was performed by repeating the wheel load $2{\times}10^6$ cycles to verify the safety of the half-depth precast deck with RC rib panel under actual conditions. As a result, fatigue effect due to repetition of wheel load was not significant in terms of serviceability such as crack width and deflection. In the residual strength test conducted after the fatigue test, the half-depth precast deck with RC rib panel failed by punching shear which is typical failure mode of bridge decks and the residual strength was similar to the punching strength of the RC and PSC bridge decks in spite of the fatigue effects.

An Experimental Study on Evaluation of Fatigue Safety and Serviceability for the Precast Half Deck Panel Joints (반단면 프리캐스트 판넬 이음부의 피로 안전성 및 사용성 평가를 위한 실험적 연구)

  • Park, Woo Jin;Hwang, Hoon Hee;Kwon, Nam Seung
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.50-56
    • /
    • 2019
  • Precast members have relatively good quality because they are manufactured in an environment suitable for quality control. A typical precast method in which pre-fabricated segments are assembled in the field requires a joint. Although the joint is a small part of the member, it greatly affects the behavior and quality of the structural member. In the previous study of this paper, the flexural strength of a joint, which is generally applied to half-depth precast deck systems, was verified to have higher strength than the design requirement. In addition, the proposed joint has been verified to have higher strength by reinforcing the connecting rebar. However, even if the flexural strength of the joints is sufficient, excessive deflection or lack of fatigue performance is likely to cause cracks in the half-depth precast deck system. In this study, the serviceability of the half-deck precast panel specimens with joints was evaluated and the experimental verification was conducted to evaluate the fatigue performance of the joint without connection rebar. As a result, the serviceability such as deflection and crack width was found to be higher than the design requirement in all the specimens. In the fatigue test, the fatigue effect was insignificant even in the absence of connection rebar.

A Study on the Characteristics of Cylinder Wake Placed in Thermally Stratified Flow (I) (열성층유동장에 놓인 원주후류의 특성에 대한 연구 (1))

  • 김경천;정양범;김상기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.3
    • /
    • pp.690-700
    • /
    • 1994
  • The effects of thermal stratification on the flow of a stratified fluid past a circular cylinder were examined in a wind tunnel. In order to produce strong thermal stratifications, a compact heat exchanger type variable electric heater is employed. Linear temperature gradient of up to $250^{\circ}C/m$ can be well sustained. The velocity and temperature profiles in the cylinder wake with a strong thermal gradient of $200^{\circ}C/m$ were measured and the smoke wire flow visualization method was used to investigate the wake characteristics. It is found that the temperature field effects as an active contaminant, so that the mean velocity and temperature profiles can not sustain their symmetricity about the wake centerline when such a strong thermal gradient is superimposed. It is evident that the turbulent mixing in the upper half section is stronger than that of the lower half of the wake in a stably stratified flow.

A Tightly Regulated Triple Output Asymmetrical Half Bridge Flyback Converter

  • Hyeon, Byeong-Cheol;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.14-20
    • /
    • 2010
  • In this paper, a tightly regulated triple output asymmetrical half bridge flyback (ASHF) converter is proposed. In order to regulate all output voltages, pulse frequency modulation (PFM), pulse width modulation (PWM) and phase delay (PD) are used simultaneously. In comparison with the conventional PWM-PD method, the interactions among the control variables are minimized and the operating range is increased. By the utilization of a multi winding transformer, the auxiliary transformer and the blocking capacitor are eliminated and the size and cost of the proposed converter is reduced. The operation principle of the converter is explained and the modes of operation are investigated. Based on the results, the steady state characteristics of the converter are explored. A 24V/10A, 12V/5A, 5V/10A hardware prototype is built and tested to verify the analysis results and the voltage regulation of the triple outputs of the proposed converter.

DURABILITY TESTING OF MARINE REINFORCED CONCRETE UNDER FATIGUE LOADING, PART I AND II (피로하중을 받는 해양 콘크리트의 내구성 연구)

  • ;D. V. Reddy
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.348-353
    • /
    • 1996
  • This study addresses the evaluation of the durability of reinforced concrete marine structures subjected to fatigue loading. The laboratory investigation was carried out on full and half size reinforced concrete specimens with three different water cement ratios (0.3, 0.4, and 0.56), static and fatigue loading conditions, and epoxy-coated and regular black steel reinforcements. The marine tidal zone was simulated by alternate filling and draining of the tank (wet and dry cycled), and a galvanostatic corrosion technique to accelerate corrosion of reinforcement was used. Half-cell potentials and changes of crack width were measured periodically during the exposure and followed by ultimate strength testing. The significant findings include adverse effect of fatigue loading, existence of an explicit size effect, poor performance of epoxy coated steel, and negative effect of increasing water/cement ratio.

  • PDF

The New Evaluation Basis of Potable Water (물에 대한 새로운 평가)

  • 문승주
    • Journal of the Korean Professional Engineers Association
    • /
    • v.35 no.4
    • /
    • pp.24-28
    • /
    • 2002
  • For a long time, we use the chemical analysis only for the evaluation of potable water. but recently water which Is good or not for the vital body should be proposed to take additional new evaluation technology Nuclear Magnetic Resonance(NMR). The optimum value of NMR data should be below 100Hz of Half width.

  • PDF