Analysis of Resonant Characteristics in Asymmetrical Control Half Bridge Converter (하프 브리지 컨버터의 비대칭 제어 공진 특성 분석)

  • Ahn J.R.;Kwon M.I.;Jang D.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.58-61
    • /
    • 2003
  • In this paper, resonant Characteristics of the soft switched asymmetrical half bridge converter is analysis. The operation principle for proposed converter is explained in steady state and its circuit is analyzed by means of equivalent circuit. Experimental results carried out on a system prototype are included in this paper.

  • PDF

High Efficiency Asymmetrical Half Bridge Converter for PDP SMPS (PDP SMPS를 위한 전부하 고효율 비대칭 하프 브리지 컨버터)

  • Heo Tae-Won;Nagahara Kiyokazu;Okada Yoich;Choi Heung-Gyoon
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.131-133
    • /
    • 2006
  • A high efficiency half bridge converter for PDP in whole operation load range is proposed in this paper. The ZVS(Zero Voltage Switching) in whole load range and high efficiency in low load range is achieved because the proposed converter is switched by fixed frequency asymmetrical duty ratio and resonant operation.

  • PDF

Characteristic Analysis of Asymmetrical Half-Bridge Converter (하프 브리지 컨버터의 비대칭 제어 동작 특성 분석)

  • Ahn, Jung-Rok;Jang, Do-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1157-1159
    • /
    • 2003
  • In this paper, resonant characteristics of the asymmetrical soft switching half bridge converter is analyzed. The operation principle for proposed converter is explained in steady-state and its operation characteristics by switching frequency is presented with experimental result. Experimental results carried out on a system prototype are included in this paper.

  • PDF

Instantaneous Following Control of Half-Bridge DC-DC Converter (하프브리지 DC-DC 컨버터의 순시추종제어)

  • Ra B.H.;Lee H.W.;Kim S.D.;Kim K.T.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.54-57
    • /
    • 2003
  • A new non linear, mean value, instantaneous following control technique to design half bridge converter is proposed in witch control principle uses characteristic that reset time of analog integrator is inverse proportion In input voltage. It is Important characteristic that compensation and follow-up control time are same with switching frequency. Is completed in one cycle that base control frequency. Have excellence characteristic that follow in order instruction value exactly stationary state as well as transient state. Half bridge converter that apply this control principle can know that have stabilize and excellence characteristic. This technique is verified through an experiment, and know that experiment result and theory agree well.

  • PDF

Efficiency Characteristics of Half-bridge Series Resonant Converter for the Contact-less Power Supply (Half-bridge 직렬공진 컨버터 적용 무접점 전원장치 효율특성)

  • Lee, Hyun-Kwan;Song, Hwan-Kook;Kim, Eun-Soo;Kim, Yoon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.884-891
    • /
    • 2007
  • Comparing with the conventional transformer without the air gap, a contact-less transformer with the large air-gap (4.8cm) between the long primary winding and the secondary winding has the increased leakage inductance and the reduced magnetizing inductance. By the increased leakage inductance and the reduced magnetizing inductance on the primary of the contact-less transformer, a good deal of the primary current circulates through magnetizing inductance, which results in a massive loss and the high voltage gain characteristics for load variations in contact-less power supply (CPS). To consider these characteristics, in this paper, the efficiency characteristics of the contact-less power supply using a series resonant converter is presented, described and verified through theoretical analysis, computer simulation and experimental test of 2.5kW prototype.

Investigation of PID Fuzzy Controller for Output Voltage Regulation of Current-Doubler-Rectified Asymmetric Half-Bridge DC/DC Converter

  • Chung, Gyo-Bum
    • Journal of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.21-27
    • /
    • 2007
  • This paper investigates a PID fuzzy controller for output voltage regulation of a current-doubler-rectified asymmetric half-bridge (CDRAHB) DC/DC converter. The controller is a PD-type fuzzy controller in parallel with a linear integral controller. The PD type fuzzy controller is for providing the varying gain at the different operating conditions to regulate the output voltage. The linear integral controller is for removing the steady-state error of the output voltage. In order to show the outstanding dynamic characteristics of the proposed controller, PSIM simulation studies are carried out and compared to the results for which the conventional loop gain design method is used.

LLCT design and half-bridge series resonant converter for high density switching power supply (고집적 스위칭 전원을 위한 LLCT 설계 및 Half-Bridge 직렬공진 컨버터)

  • Park J.Y.;Kong Y.S.;Kim E.S.;Lee H.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.49-53
    • /
    • 2004
  • High density power supply technology has been researched over the last few years. In this paper, integrated LLCT(Inductor-Inductor-Capacitor-Transformer) structure is described for use in the half-bridge series resonant converter. The structure is analysed by means of FEMM(Finite Element Method Magnetics) and the experimental results of an U structure for a 300W converter we presented.

  • PDF

Common-Mode Current Cancellation Scheme of Half-Bridge Switch-Mode Converter for DC Motor Drive

  • Srisawang, Arnon;Panaudomsup, Sumit;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1876-1879
    • /
    • 2003
  • Due to the conventional half-bridge switch-mode converters for dc motor drive have been usually using unbalanced circuit topologies which generate common-mode currents through parasitic capacitors distributed between the ground and the dc motor frame such as the heat-sink of switching devices or the frame of the dc motor. This paper describes methods that cancel common-mode current generated in half-bridge switch-mode converters by using circuit balancing technique. The circuit balancing is to make the noise pickup or occurring in both conductor lines, signal and return pathes, is equal in amplitude and opposite in phase so that it will be canceled out in the ground plane. The common-mode current cancellation in the proposed converter is confirmed by experimental results.

  • PDF

A Novel Prototype of Duty Cycle Controlled Soft-Switching Half-Bridge DC-DC Converter with Input DC Rail Active Quasi Resonant Snubbers Assisted by High Frequency Planar Transformer

  • Fathy, Khairy;Morimoto, Keiki;Suh, Ki-Young;Kwon, Soon-Kurl;Nakaoka, Mutsuo
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.89-97
    • /
    • 2007
  • This paper presents a new circuit topology of active edge resonant snubbers assisted half-bridge soft switching PWM inverter type DC-DC high power converter for DC bus feeding power plants. The proposed DC-DC power converter is composed of a typical voltage source-fed half-bridge high frequency PWM inverter with a high frequency planar transformer link in addition to input DC busline side power semiconductor switching devices for PWM control scheme and parallel capacitive lossless snubbers. The operating principle of the new DC-DC converter treated here is described by using switching mode equivalent circuits, together with its unique features. All the active power switches in the half-bridge arms and input DC buslines can achieve ZCS turn-on and ZVS turn-off commutation transitions. The total turn-off switching losses of the power switches can be significantly reduced. As a result, a high switching frequency IGBTs can be actually selected in the frequency range of 60 kHz under the principle of soft switching. The performance evaluations of the experimental setup are illustrated practically. The effectiveness of this new converter topology is proved for such low voltage and large current DC-DC power supplies as DC bus feeding from a practical point of view.

A Study on the Optimal Design of LLC Resonant Half-bridge dc-dc Converter Using a Steady-state Model with Internal Loss Resistors (내부 손실 저항이 있는 정상상태 모델을 이용한 LLC 공진형 하프 브리지 dc-dc컨버터의 최적 설계에 관한 연구)

  • Yoo, Jeong Sang;Ahn, Tae Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.3
    • /
    • pp.80-86
    • /
    • 2022
  • In this paper, the optimal design and circuit simulation verification results of an LLC resonant half-bridge dc-dc converter using a steady-state model with internal loss resistance are reported. Above all, the input/output voltage gain and frequency characteristic equations in the steady-state were derived by reflecting the internal loss resistance in the equivalent circuit. Based on the results, an LLC resonant half-bridge dc-dc converter with an input voltage of 360-420V, an output voltage of 54V, and a maximum power of 3kW was designed, and to verify the design, the PSIM circuit simulation was executed to compare and analyze the result. In particular, the operating range of the converter could be drawn from the frequency characteristic graph of the voltage gain, and when the converter was operated under light and maximum load conditions, it was confirmed that similar results were obtained by comparing simulation results and calculation results in the switching frequency characteristic graph. In addition, the change of the switching frequency with respect to the load current at each input voltage was compared with the calculated value and the simulation result. As a result, it was possible to confirm the usefulness of the analysis result reflecting the internal loss resistance proposed in this paper and the process of the optimal design.