• Title/Summary/Keyword: HVAC 시스템평가

Search Result 45, Processing Time 0.03 seconds

A Study on the LCC Analysis of an Office Building HVAC System (오피스빌딩 냉난방시스템의 수명주기비용 분석에 관한 연구 : 흡수식 냉온수 유닛의 설치 유형을 중심으로 한 사례연구)

  • Park, Moon-Sun;Shin, Hyeong-Sik;Kim, Yong-Su
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.3 s.31
    • /
    • pp.112-121
    • /
    • 2006
  • The purpose of this study is to execute economical analysis for two types of office building HVAC system using LCC technique : single vs, separated HVAC(equal partition installation, unequal partition installation) system. The research method of this study includes the case analysis and questionnaire surveys. The results of this study are as follows: (1) LCCs of 3 types of HVAC system are estimated and the most economical one is investigated as single HVAC system, (2) In this case study, the single HVAC system was investigated as 34% lower in LCC during 15 years per $100m^2$ compared to equal partition installation, as 41% compared to unequal partition installation.

A Numerical Study of Automotive Indoor Thermal Comfort Model According to Boarding Conditions and Parameters Related to HVAC (HVAC 관련 매개변수 및 탑승조건에 따른 자동차 실내의 온열쾌적성 평가모델에 관한 수치해석적 연구)

  • Yoon, Seong Hyun;Park, Jun Yong;Son, Deok Young;Choi, Yunho;Park, Kyungseok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.9
    • /
    • pp.979-988
    • /
    • 2014
  • Recently, the interest in the thermal comfort is ever increasing as the time people stay in the automobile is gradually increasing. So far, however, the cooling performance of the HVAC(heating and ventilation air conditioning) system is evaluated by thermal environment criteria such as indoor air velocity and temperature, not by a thermal comfort index. Furthermore, the precise criteria has not been established yet when the thermal comfort for the automobile is evaluated using numerical analysis. In this study, the numerical analysis of automobile indoor thermal comfort according to various parameters such as HVAC operating mode, airflow, passenger boarding conditions is performed during the HVAC system's initial operating time(20 minutes). The solar ray tracing model and S2S radiation model are used and validated to simulate an external heat source. Based on this study, an evaluation model which can predict the thermal comfort index for the combination of the above parameters is presented.

Sound Quality Evaluation for the Vehicle HVAC System Using Optimum Layout of Damping material (제진재의 최적배치를 이용한 차량공조시스템의 음질평가)

  • Hwang, Dong-Kun;Abu, Aminudin Bin;Lee, Jung-Youn;Oh, Jae-Eung;Yoo, Dong-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.629-633
    • /
    • 2005
  • The reduction of the Vehicle interior noise has been the main interest of NVH engineers. The driver's perception on the vehicle noise is affected largely by psychoacoustic characteristic of the noise as well as the SPL. In particular, the HVAC sound among the vehicle interior noise has been reflected sensitively in the side of psychology. In previous study, we have developed to verify identification of source for the vehicle HVAC system through multiple-dimensional spectral analysis. Also we carried out objective assessments on the vehicle HVAC noises and subjective assessments have been already performed with 30 subjects. In this study, the linear regression models were obtained for the subjective evaluation and the sound quality metrics. The regression procedure also allows you to produce diagnostic statistics to evaluate the regression estimates including appropriation and accuracy. Appropriation of regression model is necessary to $R^2$ value and F-value. And testing for regression model is necessary to Independence, Homoscedesticity and Normality. Also we selected optimum layout of damping material using Taguchi method. As a result of application, sound quality is improved by more quiet, powerful, expensive, smooth.

  • PDF

Evaluation of Noise Reduction Performance of HVAC System for Ships (선박용 HVAC 시스템의 소음저감성능 평가)

  • Kim, Sang-Ryul;kim, Hyun-Sil;Kim, Jae-Seung;Kim, Bong-Ki;Lee, Sung-Hyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.8
    • /
    • pp.497-503
    • /
    • 2010
  • In this paper, evaluation of noise reduction performance of HVAC system for ships by means of HVAC mock-up system is presented. Test is done for six different types of HVAC elements including room unit, silencer, etc. It is found that when diameter of silencer is small and air flow is large, flow noise degrades insertion loss. However, as diameter of silencer becomes larger, the effect of flow noise becomes smaller, and insertion loss up to 25 dB is measured. It is observed that insertion loss of diffuser type room unit is usually between zero and 10 dB, whereas that of the nozzle type room unit can be down to - 15 dB. In addition, it is shown that changing duct arrangement can reduce cabin noise by up to 2 dB, and providing same air flow to each room unit is crucial for generating less noise.

Design of Optimized Multi-Fuzzy Controller by Means of Particle Swarm Optimization Algorithm for HVAC System (HVAC 시스템에 대한 PSO 알고리즘을 이용한 최적화된 Multi-Fuzzy 제어기 설계)

  • Jung, Seung-Hyun;Choi, Jeoung-Nae;Oh, Sung-Kwan;Choi, Han-Jong;Ryu, Byoung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.277-278
    • /
    • 2007
  • 본 논문은 HVAC(heating, ventilating, and air conditioning) 시스템에 대해 Particle Swarm Optimization(PSO) 알고리즘을 이용하여 최적화된 Multi-Fuzzy 제어기 설계를 제안한다. HVAC 시스템의 효율과 안정도에 결정적인 영향을 미치는 과열도와 저압(증발기의 압력)을 제어하기 위해, 3대의 Expansion Valve 와 1대의 Compressor 에서 동시에 제어하는 Multi-Fuzzy 제어기를 설계한다. 그리고 최적화 알고리즘 중 하나인 사회적인 행동양식을 기반한 PSO 알고리즘을 이용하여 설계된 Multi-Fuzzy 제어기를 최적화한다. 시뮬레이션의 결과 비교를 통해, 대표적인 최적화 알고리즘인 유전자 알고리즘을 사용한 최적화된 제어기와 제안한 PSO 알고리즘을 이용한 최적화된 제어기의 성능을 평가한다.

  • PDF

Development of an HVAC&R Systems Energy Evaluation Methodology and Simulation Program for Office Buildings (사무소 건물의 HVAC&R 시스템 에너지 분석방법 및 예측 프로그램 개발)

  • Cho, Jinkyun;Shin, Seungho;Kim, Jonghurn;Hwang, Dongkon;Hong, Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.7
    • /
    • pp.363-370
    • /
    • 2013
  • HVAC&R systems are the most energy consuming building services, representing approximately half of the final energy use in the building sector. Despite their significant energy use, there is a lack of a consistent and homogeneous framework to efficiently guide research. This research is about the energy consumptions of HVAC&R systems, with the aim of establishing a common idea for the analysis of building energy efficiency. Our approach deals with the concept of an HVAC&R set that is composed of subsystems. A matrix combination evaluation is examined, and a total of 960 sets can be implemented in a large scale office building. A method as a tool for energy evaluations of HVAC&R systems, and HEET as a energy simulation program, were developed.

Economic Analysis of Voltage Source Converter(VSC) HVDC Technologies - HVAC, LCC-HVDC, VSC-HVDC (focusing on CIGRE WG-B4.46 492 Report) - (VSC-HVDC 적용 기술의 경제성 평가 분석 - HVAC, LCC-HVDC, VSC-HVDC (CIGRE WG-B4.46 492 Report를 중심으로) -)

  • Yeo, Seo-Hyun;Seon, Hwi-il;Kim, Sun-Pil;Park, Seong-mi;Yoo, Dong-Wook;Park, Sung-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.982-983
    • /
    • 2015
  • 본 논문은 CIGRE 492 보고서를 따른 것으로 최근 해외 선도 기업 및 미국, 유럽, 중국 등에서 도입하고 있는 LCC-HVDC, VSC-HVDC와 기존 송전시스템인 HVAC의 기술 및 경제적 효율성을 비교분석하였다. 분석 방법은 동일한 조건을 설정하여 각 시스템에 모의 적용하였으며, (1) HVAC와 VSC-HVDC와의 비교 (2) LCC-HVDC와 VSC-HVDC와의 비교를 진행하였다. 그 결과 시간 흐름에 따라 AC보다 DC에서의 경제적 효율성을 확인하였고, 또한 HVDC의 전류형과 전압형의 비용 분석에서는 오차범위, 추가적 편익 등을 고려할 시 전압형의 경제성에 대한 긍정적 측면을 확인할 수 있었다. 본 연구에서는 일반적인 PWM 방식을 택하였으나, 추후 연구에서는 최근 선도 기술이라 평가받는 MMC 방식의 전압형 HVDC를 적용하여 연구하고자 한다.

  • PDF

Design and Economics of HVAC System for Reduction of Power Consumption in Blow Mold Machine (플라스틱 연료탱크 생산 설비에서의 소비 전력 저감을 위한 공조 시스템 설계 및 경제성 평가)

  • Lee, Youngjae;Choi, Seukcheun
    • Journal of Power System Engineering
    • /
    • v.21 no.4
    • /
    • pp.84-93
    • /
    • 2017
  • This study was carried out to improve the electric power consumption of HVAC in the blow mold machine(BMM) and work environment. The experiment was conducted with the simulated HVAC system of 1/15 of the actual BMM. The temperature of main facility and two preheaters was fixed at 200 and $60^{\circ}C$ respectively in all test conditions. The measured points of temperature were chosen as critical locations considering the work environment. The tendency of temperature distributions decreases as the duct was closed to the main facility. The reduction rate of power consumption of HVAC increases up to 32.3% when both duct and cooling systems are operated. Also the efficiency of HVAC is improved about 9% through the modified design of duct system. It notes that the electric power consumption of HVAC can be reduced by the optimum design and operating condition of duct and cooling system.

A Study on Plate & Shell type Evaporator in HVAC System for Offshore Plant (해양플랜트 HVAC 시스템용 플레이트·쉘 타입 증발기에 관한 연구)

  • Park, Jae-Hong
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.1
    • /
    • pp.33-40
    • /
    • 2020
  • Chiller systems which have better temperature stability than Direction expansion coils are often used as condensing units in HVAC systems for offshore plants. Large capacity compressors and electronic expansion valves in chiller systems are mostly imported, and the size of a chiller system depends on heat exchangers such as evaporators and condensers which are locally produced. Due to limited space in the offshore plants, shipyards are demanding manufacturers to make equipment compact. In this paper, a shell & tube heat exchanger, which is used as an evaporator in the conventional flooded chiller system, is replaced by a newly developed compact plate & shell heat exchanger. The main development process of the plate & shell heat exchanger is introduced, and its performances were experimentally evaluated with a real flooded chiller system, and the results are presented.

Evaluation of the Thermal and Noise Environment in an Ancient Tomb installed a Duct-type HVAC System (공조기가 설치된 고분 내에서의 열 및 음 환경 평가)

  • Park, Jin-Yang;Jun, Hee-Ho;Jun, Yong-Du;Lee, Kum-Bae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.3
    • /
    • pp.228-234
    • /
    • 2007
  • Opening an ancient tomb interior can deal fair damage for preservation in long period because of high moisture. In this study, a duct-type HVAC system was installed to preserve an ancient tomb and temperature and humidity was measured to analyze heat environment. Armhole was measured to search whether an ancient tomb receives effects of vibration caused by a duct-type HVAC system. According to the measured data, temperature in an ancient tomb is kept adaptively in conservation regardless of a duct-type HVAC system installation when it rains in summer. The other side, humidity is kept adaptively in conservation when installed duct-type HVAC system. But when it is in natural state, a lot of humidity by dew condensation phenomena. So it needs a duct-type system for an ancient tomb conservation. In the case of vibration, measurement value of 3 satisfy control but Germanic DIN 4150 does not satisfy. Therefore, equip must be such that it can prevent vibration for safety.