• 제목/요약/키워드: HVAC요소

검색결과 23건 처리시간 0.021초

건축물의 공조방식 선택과정에 있어서 질적 설계요소들의 디자인 결정방법에 관한 연구 (A Study on Design Decision of Qualitative Design Factors in Selecting of HVAC Type for Building)

  • 우세진
    • 설비공학논문집
    • /
    • 제16권8호
    • /
    • pp.762-769
    • /
    • 2004
  • Not only in building design but also in HVAC system design, it is important to ensure an objectivity in schematic design. In the study, the author suggested a method to make a logical decision for quality design factors a(footing the selection of HVAC type in initial design process, and to provide objective design values. Fuzzy theory, one of the theories describing in quantitative way the ambiguous-natured linguistic values, was used to determine the qualitative design factors of linguistic parameter nature. It was found that it has a potential as a method to determine a HVAC type satisfying the required values of qualitative design factors involved in selection of the system type. But this needs further studies to be settled in the selecting of HVAC type.

에너지 절약적 공조시스템 선정을 위한 기초적 연구 (A Study on the Energy Conservational HVAC System Design Strategies)

  • 조진균;홍민호;정차수;김병선
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.58-63
    • /
    • 2007
  • Lots of needs are being paid for how to design HVAC system in large-scale buildings. Increasing awareness of energy use is main point of this research. HVAC systems' energy characteristics are not clearly identified and understood, so the optimal design of HVAC system is very important. The energy parameters of HVAC design that are system input energy, water/air moving equipments (pumps/fans) energy and outdoor air conditioning energy for IAQ are important. The purpose of this study is to provide the basic data for energy conservational HVAC design strategies.

  • PDF

공기대 공기 에너지 회수

  • 한화택
    • 대한설비공학회지:설비저널
    • /
    • 제29권8호
    • /
    • pp.50-58
    • /
    • 2000
  • 실내공기질과 환기풍량 그리고 HVAC 관련 비틀은 서로 밀접한 관계가 있다. 공기대 공기 열 교환기를 이용하여 급기를 가열 또는 냉각함으로써 제습이나 가습의 필요성을 크게 줄일 수 있다. HVAC 설치 및 운전비용을 결정하는 가장 중요한 요소는 소요환기량, 기후변수, 열교환기 성능변수 그리고 운전기간 등이다.

  • PDF

선박용 HVAC 시스템의 소음저감성능 평가 (Evaluation of Noise Reduction Performance of HVAC System for Ships)

  • 김상렬;김현실;김재승;김봉기;이성현
    • 한국음향학회지
    • /
    • 제29권8호
    • /
    • pp.497-503
    • /
    • 2010
  • 본 논문은 여객선용 HVAC 시스템 목업을 구축하여 HVAC 요소의 성능평가를 수행한 결과를 다루었다. 측정은 룸 유니트 (Room Unit), 소음기 등 6가지 종류에 대해 이루어졌으며 여러 유량에 대해 삽입손실을 측정하였다. 소음기 직경이 작고 유량이 클수록 유동소음이 커져서 소음저감효과를 방해하지만, 직경이 커질수록 유동소음의 효과는 작아지고 삽입손실은 최대 25 dB까지 나타남을 확인하였다. 디퓨저 형태의 룸 유니트는 대체로 삽입손실이 0 - 10 dB 이지만 노즐 형태는 삽입손실이 최대 -15 dB 까지 소음이 커질 수 있음을 확인하였다. 또한 덕트 배열에 따라 최대 2 dB 까지 실내소음이 차이날 수 있음을 보였으며 각 룸 유니트에 동일한 유량이 배출하도록 조절하는 것이 보다 낮은 소음레벨을 얻을 수 있음을 확인하였다.

선박용 대형 덕트의 소음 특성 전산해석 연구 (Computational Analysis on the Noise Characteristics of Ship Large Duct)

  • 송지훈;홍석윤;이이수;권현웅
    • 해양환경안전학회지
    • /
    • 제21권6호
    • /
    • pp.751-758
    • /
    • 2015
  • 공조시스템의 소음 예측은 주로 NEBB에서 제안한 경험적인 방법에 의해 수행된다. 그러나, NEBB에서 제안한 방법은 선박에만 있는 대형 덕트의 요소를 반영하지 못하므로 선박에 적용하는데 한계가 있다. 본 논문에서는 선박용 대형 덕트의 소음 예측을 위한 전산해석방법을 연구하였다. 경계요소법을 사용하여 대형 덕트의 단위 길이당 소음 감소량에 대한 추정식을 개발하였고, 경계요소법과 전산유체역학을 사용하여 보강재가 설치된 대형 덕트에서의 유동기인소음을 예측하였다. 유입 유속이 10m/s, 보강재의 종류가 200플랫 바인 경우 100 dB 이상의 큰 소음이 발생하는 것을 알 수 있었다. 또한, 경계요소법과 유한요소법을 사용하여 덕트 투과 소음을 예측하였다. 덕트 내부와 외부의 음압 값 차이는 대략 10~15 dB정도 인 것을 알 수 있었다. 이를 통해 조선소에서는 대형 덕트를 포함한 선박 HVAC 소음 예측을 할 수 있을 것으로 기대한다.

다수의 출구를 가진 선박용 대형 저소음 룸유닛 개발 (Development of shipboard large-sized low-noise room unit with multiple outlets)

  • 김상렬;김현실;이성현;박근효
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.600-605
    • /
    • 2012
  • In this paper, the acoustic performance of a shipboard large-sized room unit is studied. The room unit is a kind of rectangular absorptive chamber with a partition whose surface absorptive material with fabric skin is attached to. The room unit has one inlet and three outlet. At the inlet, a plane damper is installed to control the flow rate. The acoustic performance of a prototype room unit is measured using a HVAC mock-up. It is shown that its insertion loss is comparable with that of a commercially-used room unit but the developed room unit generates flow noise higher than the other one. The major source of flow noise is analyzed by NADS-R, the noise analysis program for room unit. Cone-shaped dampers are proposed to be used as the damper of a room unit to reduce flow noise. It is shown that the cone-shaped damper decrease flow noise remarkably.

  • PDF

다수의 출구를 가진 선박용 대형 저소음 룸유닛 개발 (Development of Shipboard Large-sized Low-noise Room Unit with Multiple Outlets)

  • 김상렬;김현실;이성현;박근효
    • 한국소음진동공학회논문집
    • /
    • 제22권5호
    • /
    • pp.468-473
    • /
    • 2012
  • In this paper, the acoustic performance of a shipboard large-sized room unit is studied. The room unit is a kind of rectangular absorptive chamber with a partition whose surface absorptive material with fabric skin is attached to. The room unit has one inlet and three outlets. At the inlet, a plane damper is installed to control the flow rate. The acoustic performance of a prototype room unit is measured using a HVAC mock-up. It is shown that its insertion loss is comparable with that of a commercially-used room unit but the developed room unit generates flow noise higher than the other one. The major source of flow noise is analyzed by NADS-R, the noise analysis program for room unit. Cone-shaped dampers are proposed to be used as the damper of a room unit to reduce flow noise. It is shown that the cone-shaped damper decrease flow noise remarkably.

Clean Room 위험성 평가에 따른 안전성 확보에 관한 연구 (A Study on Safety by Risk Assessment of Clean Room)

  • 송윤석;윤명오;현성호;이창우;윤여송;김성민
    • 한국화재소방학회논문지
    • /
    • 제18권4호
    • /
    • pp.78-85
    • /
    • 2004
  • 본 연구에서 Clean Room 재해사례를 분석하였고, Factory Mutual Property Loss Prevention Data Sheets(FM), Industrial Risk Insurers(IRI), NFPA Code 등의 Clean Room 설계 주요 방화기준에 대하여 비교 분석을 하였다. 그리고 화재시뮬레이션을 통한 위험성 평가를 통해서 화재 시 공조설비의 작동으로 인한 연기산란 현상으로 Clean Room 내의 피해규모가 상상을 초월하는 결과를 얻을 수 있었으며, 또한 스프링클러설비의 작동으로 열온도가 더 낮아지고, 연기의 확산속도를 더 줄여줄 수 있는 것으로 분석되었다. 따라서, Clean Room내의 화재 시 화재감지기에 의해 공조설비를 정지시키고, 스프링클러설비를 설치하는 것이 안전성을 확보하는데 중요한 요소임을 유추하였다. 그러므로 본 연구에서 Clean Room 에 대한 안전성을 확보하는데 기여하고자 한다.

HACCP의 환경 최적화를 위한 식품 클린룸 설계에 관한 연구 (A study on the food clean room system observing the regulations of HACCP)

  • 원영재;서기원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.520-526
    • /
    • 2009
  • This study proposed the optimum design values for the biological clean room system observing the regulations of Hazard Analysis Critical Control Point (HACCP). Even though the standard for industrial clean room system has been well established, the basis for biological food clean room system is the first stage. In order to prevent the contaminations in advance for food storages, processes, and distributions, the criterion of Hazard Analysis Critical Control Point is positively required. This study also suggested the possible ways of how to avoid the hazardous contaminations.

  • PDF