• Title/Summary/Keyword: HSS column

Search Result 22, Processing Time 0.024 seconds

Study on Structural Performance of Two Seam Cold-Formed Square CFT Column to Beam Connections with Internal Diaphragm (2-Seam 냉간성형 각형 CFT 기둥-보 내다이아프램 접합부의 구조성능에 관한 연구)

  • Oh, Heon-Keun;Kim, Sun-Hee;Choi, Young-Hwan;Choi, Sung-Mo
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.3 no.4
    • /
    • pp.27-37
    • /
    • 2012
  • The construction of a moment connection for a rectangular hollow section (RHS) column and a H-shaped beam is difficult because the RHS is a closed section. When a inner diaphragm is used for such a connection, in general, it is installed after cutting the HSS columns, which results in increased construction work. This paper suggests a new fabrication method to overcome such problems: An inner diaphragm is welded to inside a C-shaped section first, and then a column is fabricated by welding two C-shaped sections. This fabrication method is superior to a classic method in terms of constructibility. An experimental and a numerical study using Ansys 9.0 were performed in order to compare the strength of connections with respect to the presence of concrete, the corner shape of diaphragm, and the axis of loading. The experimental results including initial stiffness and ultimate loads are reported and the analytical results including load transfer mechanism, degree of stress concentration, and strain distribution are also reported.

An approach for calculating the failure loads of unprotected concrete filled steel columns exposed to fire

  • Wang, Y.C.;Kodur, V.K.R.
    • Structural Engineering and Mechanics
    • /
    • v.7 no.2
    • /
    • pp.127-145
    • /
    • 1999
  • This paper deals with the development of an approach for evaluating the squash load and rigidity of unprotected concrete filled steel columns at elevated temperatures. The current approach of evaluating these properties is reviewed. It is shown that with a non-uniform temperature distribution, over the composite cross-section, the calculations for the squash load and rigidity are tedious in the current method. A simplified approach is proposed to evaluate the temperature distribution, squash load, and rigidity of composite columns. This approach is based on the model in Eurocode 4 and can conveniently be used to calculate the resistance to axial compression of a concrete filled steel column for any fire resistance time. The accuracy of the proposed approach is assessed by comparing the predicted strengths against the results of fire tests on concrete filled circular and square steel columns. The applicability of the proposed approach to a design situation is illustrated through a numerical example.

Geophysical investigation of methane seeps on the NE Sakhalin continental slope, Sea of Okhotsk (오호츠크해 북동사할린 대륙사면에 나타나는 메탄분출구에 대한 지구물리탐사)

  • Jin, Young-Keun;SSGH-Scientific-Party, SSGH-Scientific-Party
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.137-140
    • /
    • 2008
  • During CHAOS (2003, 2006) and SSGH projects (2007), acoustic investigation including hydroacoustic (HA), side-scan sonar (SSS) and highresolution sparker seismic (HSS) surveys was carried out on the northeastern Sakhalin slope ($53^{\circ}56'\;N$, $143^{\circ}52'\;E$ to $54^{\circ}40'\;N$, $144^{\circ}32'\;E$). More than 130 methane seeps with high backscatter intensity are identified on SSS mosaic, which are well accompanied with gas flares in the water column on HA profiles and subbottom gas chimneys on HSS profiles. It is likely that that some seeps align along a NW strike parallel to the Lavrentiev Fault.

  • PDF

Investigation of residual stresses of hybrid normal and high strength steel (HNHSS) welded box sections

  • Kang, Lan;Wang, Yuqi;Liu, Xinpei;Uy, Brian
    • Steel and Composite Structures
    • /
    • v.33 no.4
    • /
    • pp.489-507
    • /
    • 2019
  • In order to obtain high bearing capacity and good ductility simultaneously, a structural column with hybrid normal and high strength steel (HNHSS) welded box section has been developed. Residual stress is an important factor that can influence the behaviour of a structural member in steel structures. Accordingly, the magnitudes and distributions of residual stresses in HNHSS welded box sections were investigated experimentally using the sectioning method. In this study, the following four box sections were tested: one normal strength steel (NSS) section, one high strength steel (HSS) section, and two HNHSS sections. Based on the experimental data from previous studies and the test results of this study, the effects of the width-to-thickness ratio of plate, yield strength of plate, and the plate thickness of the residual stresses of welded box sections were investigated in detail. A unified residual stress model for NSS, HSS and HNHSS welded box sections was proposed, and the corresponding simplified prediction equations for the maximum tensile residual stress ratio (${\sigma}_{rt}/f_y$) and average compressive residual stress ratio (${\sigma}_{rc}/f_y$) in the model were quantitatively established. The predicted magnitudes and distributions of residual stresses for four tested sections in this study by using the proposed residual stress model were compared with the experimental results, and the feasibility of this proposed model was shown to be in good agreement.

A study on application of high strength steel SM570 in bridge piers with stiffened box section under cyclic loading

  • Kang, Lan;Suzuki, Motoya;Ge, Hanbin
    • Steel and Composite Structures
    • /
    • v.26 no.5
    • /
    • pp.583-594
    • /
    • 2018
  • Although a lot of experimental and analytical investigations have been carried out for steel bridge piers made of SS400 and SM490, the formulas available for SS400 and SM490 are not suitable for evaluating ultimate load and deformation capacities of steel bridge piers made of high strength steel (HSS) SM570. The effect of various parameters is investigated in this paper, including plate width-to-thickness ratio, column slenderness ratio and axial compression force ratio, on the ultimate load and deformation capacities of steel bridge box piers made of SM570 steel subjected to cyclic loading. The elasto-plastic behavior of the steel bridge piers under cyclic loads is simulated through plastic large deformation finite element analysis, in which a modified two-surface model (M2SM) including cyclic hardening is employed to trace the material nonlinearity. An extensive parametric study is conducted to study the influences of structural parameters on the ultimate load and deformation capacities. Based on these analytical investigations, new formulas for predicting ultimate load and deformation capacities of steel bridge piers made of SM570 are proposed. This study extends the ultimate load and deformation capacities evaluation of steel bridge piers from SS400, SM490 steels to SM570 steel, and provides some useful suggestions.

Simultaneous Liquid Chromatography Tandem Mass Spectrometric Determination of 35 Prohibited Substances in Equine Plasma for Doping Control

  • Kwak, Young Beom;Yu, Jundong;Yoo, Hye Hyun
    • Mass Spectrometry Letters
    • /
    • v.13 no.4
    • /
    • pp.158-165
    • /
    • 2022
  • Many therapeutic class drugs such as beta-blocker, corticosteroids, NSAIDs, etc are prohibited substances in the horse racing industry. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology makes it possible to isolate drugs from interference, enables various drug analyses in complex biological samples due to its sensitive sensitivity, and has been successfully applied to doping control. In this paper, we describe a rapid and sensitive method based on solid-phase extraction (SPE) using solid phase cartridge and LC-MS/MS to screen for different class's 35 drug targets in equine plasma. Plasma samples were pretreated by SPE with the NEXUS cartridge consisted non-polar carbon resin and minimum buffer solvent. Chromatographic separation of the analytes was performed on ACQUITY HSS C18 column (2.1 × 150 mm, 1.8 ㎛). The elution gradient was conducted with 5 mM ammonium formate (pH 3.0) in distilled water and 0.1% formic acid in acetonitrile at a flow rate of 0.25 mL/min. The selected reaction monitoring (SRM) mode was used for drug screening with multiple transitions in the positive ionization mode. The specificity, limit of detection, recovery, and stability was evaluated for validation. The method was found to be sensitive and reproducible for drug screening. The method was applied to plasma sample analysis for the proficiency test from the Association of Racing Chemist.

Quantitative Analys is of Flavonoids in Hovenia dulcis by Region Using UPLC (UPLC를 이용한 지역별 헛개나무(Hovenia dulcis) 플라보노이드의 정량분석)

  • Dong Hwan Lee;Hyun-Jun Kim
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2022.09a
    • /
    • pp.100-100
    • /
    • 2022
  • Hovenia dulcis is a herbal plant, which belongs to the Rhamnaceae family and is a native of Japan, China and Korea. Its fruit stalk is called 'Jiguja' in Korea. It has been traditionally used as a medicinal plant in East Asia. It was reported to have detoxification effects on alcohol poisoning, and antioxidant, antidiabetic etc. Sample of 5 g was extracted with 50 mL of 70% EtOH. The supernatant was filtered by 0.45 ㎛ membrane filter before analysis. The UPLC system was performed on Waters alliance UPLC HSS T3 column (2.1 × 100 mm, 1.7 ㎛) with a UV detector. The gradient system was a binary eluent of 0.1% formic acid in water(A) and 0.1% formic acid in acetonitrile(B) with gradient conditions as follows: Initial, 10% B; 1 min, 10% B; 4 min, 20% B; 10 min, 25% B; 12 min, 30% B; 14 min, 90% B; 17 min, 90% B; flow rate of 0.2 mL/min. The samples were injected by 2 µL and were detected at UV 355 nm. As a result of analysis, chromatographic patterns appeared in two cases: samples analyzed for ampelopsin and myricetin, and samples analyzed for taxifolin and quercetin. Among the four compounds, the largest regional difference was found to be taxifolin.

  • PDF

Quantitative Analysis of Various Carotenoids from Different Colored Paprika Using UPLC (UPLC를 이용한 색상별 파프리카 유래 카로티노이드의 정량적 평가)

  • Hwang, Jeong Rok;Hwang, In Kyeong;Kim, Suna
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.1-5
    • /
    • 2015
  • This study aimed to simultaneously determine various carotenoids from different colored paprika using an ultra performance liquid chromatograph (UPLC) equipped with a HSS T3 column. Analysis was performed at 450 nm using gradient conditions with acetonitrile/methanol/methylene chloride (65/25/10) and distilled water. We improved the peak resolution and performed carotenoid analysis within 30 min. We qualitatively analyzed 11 carotenoids (neoxanthin, capsorubin, violaxanthin, capsanthin, zeaxanthin, lutein, ${\alpha}$-cryptoxanthin, ${\beta}$-cryptoxanthin, lycopene, ${\alpha}$-carotene, and ${\beta}$-carotene). For the validation of UPLC methods, we validated the precision and accuracy of capsanthin. Capsanthin showed good linearity ($R^2$=0.9998) in the concentration range of $1-200{\mu}g/mL$ with 2.4 and $7.2{\mu}g/mL$ of limit of detection (LOD) and limit of quantification (LOQ), respectively. The relative standard deviation (RSD) for intra- and inter-day precision was less than 3.83%. Recovery was in the range of 91.86-99.87%. We quantitatively analyzed carotenoid contents from 8 different colored paprika (red, orange, yellow, and green). The most abundant carotenoids were capsanthin in red paprika, and zeaxanthin in orange, yellow, and green paprika.

Simultaneous Determination of the Flavonoids and Limonoids in Citrus junos Seed Shells Using a UPLC-DAD-ESI/MS

  • Jo, Ara;Shin, Ji hun;Song, Hwa young;Lee, Ye Eun;Jeong, Da Eun;Oh, Sung Hwa;Mun, Myung Jae;Lee, Mina
    • Natural Product Sciences
    • /
    • v.26 no.1
    • /
    • pp.64-70
    • /
    • 2020
  • Citrus junos seeds (CS) have been traditionally used for the treatment of cancer and neuralgia. They are also used to manufacture edible oil and cosmetic perfume. A large amount of CS shells without oil (CSS) are discarded after the oil in CS is used as foods or herbal remedy. To efficiently utilize CSS as a by-products, it needs to be studied through chemical analysis. Therefore, we developed an ultra-performance liquid chromatography (UPLC)-diode array detection (DAD) method for simultaneous determination and quantitative analysis of five components (two flavonoids and threes limonoids) in CSS. A Waters Acquity UPLC HSS T3 column C18 (2.1 × 100 mm, 1.8 ㎛) was used for this separation. It was maintained at 40 ℃. The mobile phase used for the analysis was distilled water and acetonitrile with gradient elution. To identify the quantity of the five components, a mass spectrometer (MS) with an electrospray ionization (ESI) source was used. The regression equation showed great linearity, with correlation coefficient ≥ 0.9912. Limits of detection (LOD) and limits of quantification (LOQ) of the five compounds were 0.09 - 0.13 and 0.26 - 0.38 ㎍/mL, respectively. Recoveries of extraction ranged from 97.45% to 101.91%. Relative standard deviation (RSD) values of intra- and inter-day precision were 0.06 - 1.15% and 0.19 - 0.25%, respectively. This UPLC-DAD method can be validated to simultaneously analyze quantities of marker flavonoids and limonoids in CSS.

Simultaneous Determination of Seven Compounds in Houttuynia cordata using UPLC-PDA

  • Kim, Hyo-Seon;Lee, A-Yeong;Park, Jun-Yeon;Jo, Ji-Eun;Moon, Byeong-Cheol;Chun, Jin-Mi;Kil, ki-Jung;Kim, Ho-Kyoung
    • Natural Product Sciences
    • /
    • v.18 no.3
    • /
    • pp.158-165
    • /
    • 2012
  • A UPLC method for the simultaneous determination of seven compounds was established for the quality control in H. cordata. The UPLC was performed on a $C_{18}$ HSS T3 $2.1{\times}100$ mm, 1.8 ${\mu}m$ column during a 13 minute gradient elution of 0.2% aqueous acetic acid and acetonitrile with the flow rate of 0.2 mL/min at $30^{\circ}C$. The UPLC method was validated according to the ICH guideline of analytical procedures with respect to precision, accuracy, and linearity. The limit of determination and quantitation for the seven compounds were 0.01-0.09 and 0.03-0.28 ${\mu}g/mL$, respectively. The calibration curves of all seven compounds showed good linearity ($r^2$ > 0.999). The intra-day and inter-day the RSD values used to evaluate the precision of analysis were less than 0.9%. The recoveries of quantified compounds ranged from 98.63 to 103.85%. The developed UPLC method was found to be effective, convenient and sensitivity for quantitative analysis of seven compounds in H. cordata. This work could be provided a baseline source for quality control of H. cordata.