• 제목/요약/키워드: HSGC

검색결과 4건 처리시간 0.025초

폴리에틸렌계 위생용 용기포장재중의 1-hexen과 1-octene 조사 (Mornitoring of 1-hexene and 1-octene in Hygienic Polyethylene-based Packaging)

  • 조성자;김애경;곽재은;김지영;김시정;금진영;김일영;김정헌;채영주
    • 한국식품위생안전성학회지
    • /
    • 제26권4호
    • /
    • pp.383-387
    • /
    • 2011
  • The levels of migration of 1-hexene and 1-octene residues in PE (polyethylene) products were analyzed by Headspace gaschromatography (HSGC). A total of 21 samples were including lap, polyglove, zipper bag and ect. The samples were eluted with distilled water, 4% acetic acid, 20% ethanol and n-heptan. The limit of detection (LOD) was 0.06 mg/L ~ 0.30 mg/L and limit of quantitation (LOQ) was 0.21 mg/L ~ 1.01 mg/L, respectively. But because of the high volatile, n-heptan elution was not detected 1-hexene and 1-octene standard. 1-hexene and 1-octene were not detected in the sample which eluted with simulant at $60^{\circ}C$, 30min. Microwave for 1 minute also treated sample and direct heated at $100^{\circ}C$ without simulant were not detected.

헤드스페이스 가스크로마토그라프에 의한 식품포장재 중의 잔류용제 분석연구 (Quantitative Determination of Solvents in Food Packaging Film Using Headspace Gas Chromatography)

  • 김현위;차익수;김진호;박기문
    • 한국식품과학회지
    • /
    • 제28권6호
    • /
    • pp.1177-1179
    • /
    • 1996
  • 식품포장재에 함유되어있는 톨루엔 및 잔류용제를 용출분석하는 방법으로 headspace gas chromatography (static headspace method)를 이용하였다. 5종(methanol, isopropyl alcohol, ethyl acetate, methyl ethyl ketone, toluene)의 표준용제에 대한 머무름시간과 상대표준편차를 검토해 본 결과, 이상적인 머무름시간의 상대표준편차라 할 수 있는 0.15% 이하로 양호하였으며 재현성도 우수하였다. 인쇄된 포장재를 분석한 결과. 주로 methanol, toluene, methyl ethyl ketone이 검출되었고, methanol은 불검출${\sim}0.939\;mg/m^2$, toluene은 불검출${\sim}1.403{\;}mg/m^2$, methyl ethyl ketone은 불검출${\sim}0.932\;mg/m^2$ 함유 되어있는 것으로 나타났으며, 총 잔류 용제는 불검출${\sim}2.433{\;}mg/m^2$ 함유되어 있는 것으로 나타났다.

  • PDF

NMF를 포함하는 이성분계의 등온 기-액 평형과 삼성분계 액-액 평형 (Binary Vapor-Liquid Equilibria and Ternary Liquid-Liquid Equilibria for NMF Contained Systems)

  • 박소진;한규진;원동복;오종혁;최영윤
    • Korean Chemical Engineering Research
    • /
    • 제43권2호
    • /
    • pp.259-265
    • /
    • 2005
  • Water+n-methylformamide(NMF), benzene+NMF 그리고 toluene+NMF의 353.15 K 이성분계 등온 기-액상평형을 headspace gas chromatography(HSGC)로 측정하였고, NMF+benzene+n-heptane과 NMF+toluene+n-heptane 삼성분계에 대한 298.15 K 액-액상평형을 tie-line 측정법으로 결정하였다. 이성분계 기-액상평형 데이터는 공비점이 없었으며, $g^E$ 모델식(Margules, van Laar, Wilson, NRTL, UNIQUAC)에 비교적 작은 편차로 잘 상관되었다. 삼성분계 tie-line 데이터는 NRTL식과 UNIQUAC식을 이용하여 상관과 추산을 병행하였으며, Hirata-Fujita식과 Maior-Swenson식을 이용하여 정확도를 검증하였다.

Propyl vinyl ether+Ethanol+Benzene 혼합계의 333.15 K에서의 등온 기액평형과 303.15 K에서의 과잉물성 및 굴절율편차 (Isothermal Vapor-Liquid Equilibria at 333.15 K and Excess Molar Volumes and Refractive Indices at 303.15 K for the Mixtures of Propyl vinyl ether + Ethanol + Benzene)

  • 황인찬;박소진
    • Korean Chemical Engineering Research
    • /
    • 제49권1호
    • /
    • pp.56-61
    • /
    • 2011
  • Methyl vinyl ether, propyl vinyl ether, isopropyl vinyl ether, butyl vinyl ether 그리고 isobutyl vinyl ether 등의 alkyl vinyl ether는 화학 및 의약산업에서 용매와 합성중간체로 널리 사용된다. 최근 들어 alkyl vinyl ether는 고분자 전해질막 연료 전지에 대한 원료와 셀룰로오스의 염색가공에 선호되나, 공정 및 운전변수의 최적화를 위한 alkyl vinyl ether계의 혼합물성은 극히 일부가 보고되고 있고, propyl vinyl ether(PVE)에 대한 상평형과 물성 데이터는 거의 알려진 바가 없다. 따라서 본 연구는 {PVE + ethanol + benzene} 삼성분계 333.15 K에서 기액평형을 headspace gas chromatography (HSGC)을 이용하여 측정하였고 Wilson, NRTL 및 UNIQUAC 식에 상관시켰다. 또한 삼성분계를 구성하는 혼합물성으로써 {PVE + ethanol}, {ethanol + benzene} 그리고 {PVE + benzene}계에 대한 과잉부피($V^E$) 및 굴절율 편차(${\Delta}R$)를 303.15 K에서 측정하였다. 측정된 이성분계 혼합물성은 Redlich-Kister 다항식을 이용하여 매개변수를 상관시켰으며, 이를 이용하여 Radojkovi 식으로 삼성분계 혼합물성을 예측하였다.