• Title/Summary/Keyword: HS type test

Search Result 28, Processing Time 0.021 seconds

Characterization of Heterodera sojae Virulence Phenotypes in Korea

  • Kang, Heonil;Ko, Hyoungrai;Park, Byeongyong;Choi, Insoo
    • The Plant Pathology Journal
    • /
    • v.38 no.4
    • /
    • pp.366-371
    • /
    • 2022
  • The white soybean cyst nematode Heterodera sojae, isolated from the roots of soybean in Korea, is widespread in most provinces of the country and has the potential to be as harmful to soybean as H. glycines. Determining the virulence phenotypes of H. sojae is essential to devising management strategies that use resistant cultivars. Consequently, virulence phenotypes of 15 H. sojae populations from Korea were determined on seven soybean lines and one susceptible check variety. Two different HS types were found to be present in Korea; the more common HS type 2.5.7, comprising 73.3% of the H. sojae populations and the less common HS type 0, constituting only 26.7% of the tested populations. Considering the high frequency of H. sojae adaptation to soybean indicator lines, the PI 88788 group may not be a possible source of resistance while PI 548402, PI 90763, PI 437654, and PI 89772 can be used as resistance sources for soybean breeding programs aimed at developing H. sojae-resistant soybean cultivars in Korea.

Associations of intermediate hyperglycemia with elevated abdominal obesity, high-sensitivity C-reactive protein, and leptin in Korean adults

  • Heashoon Lee
    • Journal of Korean Biological Nursing Science
    • /
    • v.26 no.3
    • /
    • pp.250-258
    • /
    • 2024
  • Purpose: This study investigated the associations between intermediate hyperglycemia (IH) and increased body mass index (BMI), abdominal obesity (AO), high-sensitivity C-reactive protein (hs-CRP), and leptin levels in Korean adults. Methods: The participants were 248 adults (≥ 19 years) who understood the purpose of the study, had no cognitive impairment, and were able to communicate. Physical examinations, BMI, AO measurements, and blood tests were performed. Data were analyzed using the t-test, chi-square test, Pearson correlation coefficients, and multiple logistic regression analyses. The risk factors for IH were predicted after adjusting for BMI, waist circumference (WC), age, hs-CRP and leptin levels, education, and economic status. Results: WC, hs-CRP and leptin levels, and age were higher in the IH group than in the non-IH group. According to the multiple logistic regression analysis, the factors affecting IH prevalence were WC, hs-CRP, leptin, and age. AO (male, WC ≥ 90 cm; female, WC ≥ 85 cm) exhibited an adjusted odds ratio of 5.45 for IH. IH was 2.43 times higher in those with hs-CRP > 3 mg than in those with hs-CRP < 1 mg. As leptin levels increased, the odds ratio for IH increased by 3.05 times. IH was 8.07, 8.79, 18.42, and 35.33 times more common for those in their 30s, 40s, 50s, and ≥ 60 years of age, respectively, than those 19-29 years old. Conclusion: This study provides evidence that interventions for AO should be included in IH management programs. Identifying the predictive factors for IH may contribute to the early detection of type 2 diabetes mellitus.

Characterization of Antibacterial Substance - Producing Bacillus subtilis Isolated from Traditional Doenjang (전통 된장으로부터 분리한 향균물질 생산 Bacillus subtilis의 특성)

  • Ryu, Hyun-Soon;Shon, Mi-Yae;Cho, Soo-Jeong;Park, Seok-Kyu;Lee, Sang-Won
    • Applied Biological Chemistry
    • /
    • v.50 no.2
    • /
    • pp.87-94
    • /
    • 2007
  • A bacterium which has high enzymatic activities such as amylase, cellulase and protease was isolated from Korean traditional soybean food, doenjang. The isolated bacterium was identified to Bacillus subtilis HS25 by the test of morphological and biochemical properties according to Bergey's Manual of Systematic Bacteriology and API 50 CHL kit, and by the 16S rDNA sequence. The isolated B. subtilis HS25 had a potent antibacterial activity against food born causative or pathogenic bacteria. B. subtilis HS25 is endospore forming cell and contained flagella and abundant viscous material at the out layer of cell wall. It was rod type bacterium $(0.5{\sim}0.8{\times}3{\sim}5{\mu}m)$ having biochemical characteristics such as gram staining(+), catalase(+), oxidase(-) and hydrolysis of esculin(+). The optimal medium compositions for production of antibacterial substance in the B. subtilis HS25 were 1% of soluble starch, 0.5% of yeast extract, 0.5% of peptone and 0.05% of MgCl$_2{\cdot}6H_{2}O$. The optimum temperature and pH of the growth of the B. subtilis HS25 was 35$^{\circ}C$ and pH 7.5, respectively. The antibacterial activity was more high in neutral to a little alkaline pH (6.5-10.5) than in acidic pH. The optimal shaking speed to grow and to produce antibacterial substance of the B. subtilis HS25 was 160${\sim}$200 rpm. The optimal culture time for antibacterial activities of the bacterium were shown to be in the range of 12-36 hr.

Overloading Control Effectiveness of Overweight Enforcement System using High-Speed Weigh-In-Motion (고속축중기를 활용한 과적단속시스템의 과적 억제효과 분석)

  • Kwon, Soon-Min;Jung, Young-Yoon;Lee, Kyung-Bae
    • International Journal of Highway Engineering
    • /
    • v.14 no.5
    • /
    • pp.179-188
    • /
    • 2012
  • PURPOSES: The aim of this study is to analyze overloading control effectiveness of enforcing overweighted vehicles using HS-WIM (High-Speed Weigh-in-Motion) at main lane of expressway. METHODS: To analyze the weight distribution statistically, HS-WIM system should has an appropriate weighing accuracy. Thus, the weighing accuracy of the two HS-WIM systems was estimated by applying European specifications and ASTM (American Standards for Testing and Materials) for WIM in this study. Based on the results of accuracy test, overweight enforcement system has been operated at main lanes of two expressway routes in order to provide weight informations of overweighted vehicle in real time for enforcement squad. To evaluate the overloading control effectiveness with enforcement, traffic volume and axle loads of trucks for two months at the right after beginning of the enforcement were compared with data set for same periods before the enforcement. RESULTS: As the results of weighing accuracy test, both WIM systems were accepted to the most precise type that can be useful to applicate not only statistical purpose but enforcing on overweight vehicles directly. After the enforcement, the rate of overweighted trucks that weighed over enforcement limits had been decreased by 27% compared with the rate before the enforcement. Especially, the rate of overweighted trucks that weighed over 48 tons had been decreased by 91%. On the other hand, in counterpoint to decrease of the overweighted vehicle, the rate of trucks that weighed under enforcement limits had been increased by 7%. CONCLUSIONS: From the results, it is quite clear that overloading has been controlled since the beginning of the enforcement.

Active Dynamic behavior Control of Vehicle by Using Semi-intelligent Suspension System (반지능형 현가시스템에 의한 차량의 능동적인 동적거동제어)

  • 김대원;배준영;신중호
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.6
    • /
    • pp.15-21
    • /
    • 1998
  • Mostly a ride comfort and handling performance of vehicle is influenced by dynamic behavior control of vehicle. We are focusing on development of a semi-intelligent suspension system with continuously variable damper(HS-SH type). only using absolute velocity of sprung mass without using the relative velocity besides having lower system prices and a little energy requirement. In this paper, the system is realized in consideration to control strategy (sky-hook control, hybrid filter, etc.) and has been proved to have improvement of behavior control of vehicle by quarter car and Vehicle test, respectively.

  • PDF

A Comparative Study of Operation characteristics of Active Clamp Forward Converter Based on Loss Analysis (손실해석을 통한 능동 클램프 포워드 컨버터의 동작 특성비교)

  • Oh, Deog-Jin;Kim, Hee-Jun;Kim, Chang-Sun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2039-2041
    • /
    • 1998
  • In this paper, Operation characteristics of the active clamp(ACL) zero-voltage-switching(ZVS) forward converter(FC) and active clamp hard- switching(HS) forward converter are compared with respect to loss analysis. The losses of semiconductor (including conduction losses and switching losses), transformer(containing the core loss and copper loss) and parasitic element of passive element (capacitor, inductor) are measured and compared for each type. For an experiment we have built 50W ACL ZVS-FC and ACL HS-FC, in which the switching frequency is 200kHz, and test it. The experimental results show that both types of operation have nearly same characteristics.

  • PDF

A COMPARISON OF MASTER APICAL FILE SIZE ACCORDING TO INSTRUMENTATION IN TYPE II ROOT CANAL (제2형 근관의 확대에 따른 최종근관장파일 크기의 비교)

  • Jeong, Eun-Ju;Lee, Dong-Kyun;Baek, Shin-Young;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.5
    • /
    • pp.435-442
    • /
    • 2008
  • Type II root canal was defined that two canals leave the chamber and merge to form a single canal at short of the apex. The aim of this study was to analyse the master apical file (MAF) size according to various instrumentation techniques in the type II root canal when each canal was enlarged to working length. Eighty mesial roots of molar with ISO #15 initial apical file (IAF) size in type II root canals were randomly divided into four experimental groups with 20 teeth each. According to enlarging instruments, four groups are: K-$FLEXOFILE^{(R)}$ (KF), engine-driven Ni-Ti $P_{RO}T_{APER}{^{(R)}}$ (PT), HERO $Shaper^{(R)}$ (HS), $K^{3\;TM}$ (K3). All canals were enlarged to each working length with ISO #30 size: #30 in KF, F3 in PT, .04/30 in HS, and .06/30 in K3. The master apical file (MAF) size was confirmed by tactile sensation and universal test- ing machine (EZ test, Shimadzu Co., Kyoto, Japan). The mean MAF size was statistically compared using one-way ANOVA and Tukey HSD test at the 0.05 probability level. These results show that the MAF size was appeared one or two sizes larger than the final enlarging instrument when all canal in type II configuration were enlarged to each working length. Therefore, the clinician have to confirm the apical stop once more after instrumentation of type II root canal.

An Analysis of Test Results Using the New Fusion Weight Conversion Algorithm for High-speed Weigh-In-Motion System (주행시험을 통한 고속축중기의 융합형 중량환산 알고리즘 효과 분석)

  • Kim, Jong Woo;Jung, Young Woo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.4
    • /
    • pp.67-80
    • /
    • 2020
  • High-speed weigh in motion (HS-WIM) is a real-time unmanned system for measuring the weight of a freight-carrying vehicle while it is in motion without controlling vehicle traffic flow or deceleration. In Korea, HS-WIM systems are installed on the national highways and general national ways for pre-selection by law enforcement. In this study, to improve the measurement accuracy of HS-WIM, we devise improvements to the existing integral and peak weight conversion algorithms, and we provide a new fusion algorithm that can be applied to the mat-type HS-WIM. As a result of analyzing vehicle driving tests at a real site, we confirmed the highest level of weight-measuring accuracy.

Proficiency testing of cadmium and lead in polypropylene resin (폴리프로필렌 수지 중 카드뮴과 납 측정 숙련도시험)

  • Cho, K.H.;Lim, M.C.;Min, H.S.;Han, M.S.;Song, H.J.;Park, C.J.
    • Analytical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.183-192
    • /
    • 2007
  • The various environmental regulation directives such as RoHS (restriction of hazardous substances in electrical and electronic products) and WEEE (waste from electrical and electronic equipments) are practically used as the technical barrier in international trade (TBT) of vehicles and electrical and electronic products recently. Regarding such an environmental regulation, Korea Research Institute of Standards Science (KRISS) organized a proficiency testing scheme to establish the reliability of measurement results produced by the relevant research institutes and test laboratories in Korea. Participants were 31 laboratories related to production of the electrical and electronic equipments and mobile vehicles. Two polypropylene samples of pellet type were employed as the proficiency testing materials (PTMs). Cadmium and lead were the analytes chosen among six components regulated in European Union (EU) RoHS directive. The PTMs were sent to the participants by post on September $1^{st}$ 2006, and deadline for results submission were October $10^{th}$ 2006. The results of each laboratory were evaluated in comparison with KRISS reference values using Robustic Z-score and Youden plot methods. The results of the various sample digestion methods were also compared. Most of participants reported good agreement within 10 % range of reference values. However, results from several laboratories showed significant biases from reference values. These laboratories should establish the quality assurance system for improvement of the measurement reliability.

Development of fishing gear and fishery operation system for the croaker drift gill net 2. Performance tests of labor saving type model net hauler (조기유자망 어구의 개량 및 생력화 조업시스템 개발 2. 생력형 모형 양망기의 성능 시험)

  • Kim, Suk-Jong;Koo, Myung-Sung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.41 no.3
    • /
    • pp.199-206
    • /
    • 2005
  • As the basic study about improvement of yellow croaker drift gill net fishing implement and development of the fishing system, this study drew problem after synthetically analyzing hauling system of yellow croaker drift gill net used in the coast of Chuja Island and tested several characters and analyzed in hauling process with 5 step net hauler model for improving the problem. The analysis results are as follows. When the angle between axises of drum centers was small, it showed the tendency that hauling time was fast. Hauling time was faster when drum was 5 step rather than 3 step. When drum was 5 step, slippery phenomenon was small and hauling was stable. Tension was larger when drum was 5 step rather than 3 step. When drum was 5 step, the range of change of the maximum and minimum value was small and hauling was stable. When drum was 3 step, there was following formula between hauling time ($Ht_3$) and angle between axises of drum centers ($A_g$) $Ht_3$ : ($7.15Hs^{-0.81}$) $A_g^{-0.81}$, when drum was 5 step there was following formula.$Ht_5$ : ($6.45Hs^{-0.75}$) $A_g0.10$, here, Hs is hauling speed. When drum was 3 step and hauling speed was 28cm/sec, tension was $T=0.08A_8^3-1.60A_g^3-0.49A_g+369.56(r=0.99)$, when drum was 5 step, tension was, $T=-0.01A_g^3+1.96A_g^2-34.05A_g+414.58$ (r-0.99), here, T was tension(g).