• Title/Summary/Keyword: HRV spectrum

Search Result 51, Processing Time 0.037 seconds

An Analytical Comparison in Electoencephalography and Electrocardiography under Pulsed Magnetic Field and Acupuncture Stimulus on Acupoint PC9

  • Lee, Hyun Sook;Hwang, Do Guwn;Cha, Yun-Yeop
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.192-196
    • /
    • 2013
  • We have investigated the changes of electroencephalography (EEG) and electrocardiography (ECG) under pulsed magnetic field (PMF) and acupuncture stimulus on acupoint PC9. In order to compare quantitatively the effect of PMF and acupuncture stimulus, the difference of alpha activities are calculated from EEG spectra, and the spectrum curves of ECG were analyzed in the frequency domain of heart rate variability (HRV). The increase of alpha activities after both stimuli could be explained that the impulse of stimulus on PC9 might pass through sensory nerve following meridian and approach the cerebral cortex, causing the central nervous system (CNS) to be activated for pacifying emotion and calming the mind. The decrease in sympathovagal activity of HRV after both stimuli indicates that parasympathetic nerves were activated and the sympathetic nerves were in constrained condition. These findings suggest that PMF could be patient-friendly alternative non-invasive medical treatment for influencing human physiology, in comparison with acupuncture inserting the needle and inducing nervous and anxious state to subject.

A Study on Human Autonomic Nervous System Activities by Far-Infrared Ray Hyperthermia (원적외선 온열이 인체 자율신경기능에 미치는 영향에 관한 연구)

  • Park Chan-Ouk;Jang Yun-Ho;Min Se-Dong;Kang Se-Gu;Lee Chung-Keun;Lee Myoungho
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.623-628
    • /
    • 2004
  • This paper describes autonomic nervous system activities caused by hyperthermia of far-infrared ray on human body. Designed protocol and analysis algorithm were evaluated by experiments on 20 subjects to analyze the characteristic of heart rate variability(HRV) signals which could be analyzed by FFT power spectrum and time-frequency analysis. Using Poincare' plot analysis, LF and HF were compared with SD1 and SD2. During the experiment, subject was exposed to hyperthermic effects of far-infrared radiation. We could confirm that far-infrared ray, which was known to improve the blood circulation, stress state and enhancing thermal effect into human body, had an effect on human nervous system. As the hyperthermic temperature of far-infrared ray increased, the activity of cardiovascular system to sustain the homeostasis was observed by means of investigating the increase of the sympathetic activity.

The Effect of Acupuncture Treatment on the Heart Rate Variability of Chronic Headache Patients (만성두통환자에 대한 침치료가 심박변이도에 미치는 영향)

  • Jung, In-tae;Lee, Sang-hoon;Kim, Su-young;Cha, Nam-hyun;Kim, Keon-sik;Lee, Doo-ik;Lee, Jae-Dong;Lim, Sabina;Lee, Yun-ho;Choi, Do-young
    • Journal of Acupuncture Research
    • /
    • v.22 no.3
    • /
    • pp.105-112
    • /
    • 2005
  • Obiective : The purpose of this study was to assess the effect of acupuncture treatment for chronic headache patients using power spectrum analysis of the heart rate variability(HRV). Methods : 15 clinical experiment participants were gathered and through a questionnaire patients who experienced headache for more than 4 hours a day and more than IS days per month were qualified as Chronic Headache patients. Treatment was afplied 2 times a weeks for 8 weeks. The acupoints, GV2O, HN23, ST8, HN46, TEl7, GB2O, LI2O, LI11, LI14, ST36, and LR3 were stimulated for 20 minutes. The effects of acupuncture treatment were analyzed using power spectrum analysis of the HRV. HRV was recorded before and after acupuncture treatment. Results : HRV before and after treatment was compared after 8 weeks of acupuncture treatment. Increase in mean values of SDNN and RMSSD were observed but the increases were not statistically significant. Increase in mean values of TP, LF and HF were observed but, the increase was significant(p<0.05) only in TP. Conclusions : The results suggest that acupuncture treatment on chronic headache patients can increase the activity of autonomic nervous system. Further use of HRV for quantitative analysis of acupuncture treatment on autonomic nervous system related symptoms is suggested.

  • PDF

Study on the Detection the Section with the Motion Artifacts of the PPG Signal (PPG 신호의 동잡음 구간 검출에 관한 연구)

  • Lee, Hanwook;Lee, Gunki
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • The biomedical information (heart rate, HRV, $SpO_2$ etc) from the Photoplethysmography (PPG) signal section can be estimated without the motion artifacts if the PPG signal section in the motion artifacts is detected accurately. But the PPG signal is easily exposed to the motion artifacts by the decrease of the medical instrument size and applying as portable or wearable. Besides, it is difficult to completely eliminate the motion artifacts from the PPG signal without distortion and ensure reliability as well. In this paper, the method was suggested to determine the motion artifacts or not on the PPG signal of the section divided into intervals of constant length. By comparing the spectrum of each section, it can be determined whether the motion artifacts are or not after obtaining the spectrum of each section by the Goertzel algorithm. Moreover, an amount of computation while maintaining a high detection rate can be reduced by using the Goertzel algorithm.

Analysis of Vestibuloautonomic Reflex by Heart Rate Variability (심박수 변이도를 이용한 전정자율신경반사의 분석)

  • 오경아;박옥규;김민선;김재효;박병림
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1999.03a
    • /
    • pp.243-248
    • /
    • 1999
  • There is substantial evidence that anatomical connections and functional interactions exist between vestibular and autonomic systems. Heart rate variability (HRV) including mean, standard deviation, coefficient of variation (CV), power spectrum was analyzed for evaluation of the physiological role of the vestibular system on control of heart rate in rabbits. In anesthetized rabbits, electrical stimulation of the vagus nerve decreased heart rate and decreased LF/HF by increasing HF. On the cervical sympathetic nerve increased heart rate and increased LF/HF by increasing LF. Atropine, cholinergic blocker, increased heart rate and increased LF/HF by reducing HF, and propranolol, ${\beta}$-adrenergic blocker, decreased heart rate and decreased LF/HF by reducing LF> In unanesthetized rabbits, stimulation of the vestibular system induced by rotation or caloric increased heart rate and increased LF/HF by increasing LF> Also electrical stimulation of the vestibular nerve produced the same of effects as rotation or caloric in anesthetized rabbits. These results suggest that Stimulation of the vestibular system increased heart rate not by inhibiting the parasympathetic nerve but by activating the sympathetic nerve.

  • PDF

Wireless Transmitter earpiece for Sensibility Ergonomics (감성공학을 위한 무선 이어폰 전송 장치)

  • Lim, Chae-Young;Jeon, Ki-Man;Kim, Kyung-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.06a
    • /
    • pp.273-276
    • /
    • 2011
  • 우리는 감성 공학에 기반하여 일상 생활 속에서 비침습적이면서 사용하기 간편한 광전용적맥파신호를 계측하고 분석하는 이어폰형 생체 신호 측정 시스템에 관하여 연구하였다. 생체 신호 측정 시스템에서는 광전용적맥파(photoplethysmograph, PPG)와 3축 가속도로 생체 신호와 운동 신호를 활용하였다. 수신된 생체 신호인 광전용적맥파 신호는 Peak 검출 및 전처리 알고리즘을 통하여 심박동변동성(heart rate Variablity,HRV)에 대한 시계열 정보로 변환하고 고속 퓨리에 변환(Fast Fourier Transfirm, FFT)과 전력 스펙트럼 밀도 분석(Power Spectrum Density, PSD)방법으로 교감과 부교감 신경 활성도 변화를 관측하였고, 운동 센서로 움직임을 관측하였다. 수신부 시스템은 안드로이드 기반의 자바 어플리케이션으로 스마트 폰에서 구현하였고, 송신부인 이어폰 생체정보 측정모듈로 맥파를 측정하여 상황에 따라 변화하는 자율 신경계의 활성도비율을 확인하였다.

  • PDF

Analyzing Heart Rate Variability for Automatic Sleep Stage Classification (수면단계 자동분류를 위한 심박동변이도 분석)

  • 김원식;김교헌;박세진;신재우;윤영로
    • Science of Emotion and Sensibility
    • /
    • v.6 no.4
    • /
    • pp.9-14
    • /
    • 2003
  • Sleep stages have been useful indicator to check a person's comfortableness in a sleep, But the traditional method of scoring sleep stages with polysomnography based on the integrated analysis of the electroencephalogram(EEG), electrooculogram(EOG), electrocardiogram(ECG), and electromyogram(EMG) is too restrictive to take a comfortable sleep for the participants, While the sympathetic nervous system is predominant during a wakefulness, the parasympathetic nervous system is more active during a sleep, Cardiovascular function is controlled by this autonomic nervous system, So, we have interpreted the heart rate variability(HRV) among sleep stages to find a simple method of classifying sleep stages, Six healthy male college students participated, and 12 night sleeps were recorded in this research, Sleep stages based on the "Standard scoring system for sleep stage" were automatically classified with polysomnograph by measuring EEG, EOG, ECG, and EMG(chin and leg) for the six participants during sleeping, To extract only the ECG signals from the polysomnograph and to interpret the HRV, a Sleep Data Acquisition/Analysis System was devised in this research, The power spectrum of HRV was divided into three ranges; low frequency(LF), medium frequency(MF), and high frequency(HF), It showed that, the LF/HF ratio of the Stage W(Wakefulness) was 325% higher than that of the Stage 2(p<.05), 628% higher than that of the Stage 3(p<.001), and 800% higher than that of the Stage 4(p<.001), Moreover, this ratio of the Stage 4 was 427% lower than that of the Stage REM (rapid eye movement) (p<.05) and 418% lower than that of the Stage l(p<.05), respectively, It was observed that the LF/HF ratio decreased monotonously as the sleep stage changes from the Stage W, Stage REM, Stage 1, Stage 2, Stage 3, to Stage 4, While the difference of the MF/(LF+HF) ratio among sleep Stages was not significant, it was higher in the Stage REM and Stage 3 than that of in the other sleep stages in view of descriptive statistic analysis for the sample group.

  • PDF

Spectral Analysis of Heart Rate Variability during Treadmill Exercise at Various Speeds and Grades

  • Kim, Hyeong-Jin;Kim, Ki-Hong;Ahn, Dong-Kuk;Park, Jae-Sik
    • The Korean Journal of Physiology
    • /
    • v.30 no.1
    • /
    • pp.43-51
    • /
    • 1996
  • This study was aimed to elucidate the changes in heart rate variability during treadmill exercise at various speeds and grades by spectral analysis. Thirty-three untrained male college students aged $20{\sim}26\;yr $were employed to exercise on a treadmill using 4 speeds (4.02, 5.47, 6.76 and 8.05 km/h) and 6 grades (0, 4, 8, 12, 16 and 20%). A fixed speed was selected for each session with the grade increased every 3 min. The electrocardiogram, respiration and the stepping activity were continuously recorded through an A/D converter system on the computer disk. Power spectra of heart rate variability (RRV) were obtained by use of a fast Fourier transform algorithm. The frequency domain was divided into 3 bands: $VLF\;(0{\sim}0.04\;Hz),\;LF\;(0.04 {\sim}0.15\;Hz)\;and\;HF\;(0.15{\sim}1.00\;Hz).$ Heart rate was $74.4{\pm}2.1\;beats/min$ at rest and showed a steady increase during treadmill exercise with increasing speed and grade up to $196.7{\pm}5.0\;beats/min.$ Total power of HRV was $35.0{\pm}6.7\;(beats/min)^{2}$ at rest and progressively decreased during exercise down to $1.9{\pm}0.3\;(beats/min)^{2}.$ The %VLF power of HRV was $34.5{\pm}3.7\; %$ at rest and showed no significant change during exercise except for a decrease observed at the highest intensity of exercise. The %LF power was $44.1{\pm}3.0\;%$ at rest and showed a progressive decrease down to $4.5{\pm}1.0\;%$ during those stages of exercise where heart rate was over 135 beats/min. The %HF power was $21.4{\pm}2.9\;%$ at rest and showed a progressive increase up to $87.1{\pm}6.7\;%$ during higher intensity exercise where heart rate was over 165 beats/min. Peak frequency of HF band was $0.200{\pm}0.018\;Hz$ at rest and was shifted to higher frequencies up to $0.909{\pm}0.048\;Hz$ at heart rates greater than 135 beats/min. Respiratory frequency was $18.0{\pm}1.5$ breaths/min at rest and significantly increased during exercise up to $53.0{\pm}3.7$ breaths/min. Stride frequency during treadmill exercise showed an increasing tendency with increasing speed from $55.6{\pm}0.9$ steps/min at 4.02 km/h to $81.2{\pm}0.6$ at 8.05 km/h. It was concluded that total power of HRV decreased progressively with increasing exercise intensity due to the withdrawal of parasympathetic activity. At higher exercise intensity, % LF power decreased and %HF power increased with its peak frequency shifted to higher values in a progressive mode with increasing speed and grade, reflecting a readjustment in the cardiovascular system and the increased respiration and its rate, respectively.

  • PDF

Study on the Effect of Cognitive Function by Color Light Stimulation (색채 조명 자극이 인지기능에 미치는 영향에 관한 연구)

  • Chong, Woo-Suk;Yu, Mi;Kwon, Tae-Kyu;Kim, Nam-Gyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.10
    • /
    • pp.131-136
    • /
    • 2007
  • In this paper, we estimated the effects of different color stimulation on the cognitive function of human quantitatively. For the stimulations we used color lights with 6 color filters such as red, yellow, green, blue, violet and white. The experiment was performed in a soundproof chamber. 50 young male and female subjects were participated in the experiment. To find the appropriate color cognitive function, the endogenous visuospatial attention task(EVAT) and one back working memory task(OWMT) were performed. The reaction time and accuracy degree were measured. The results showed that the reaction time of EVAT was the fastest and the accuracy degree of attention task was the highest in green environment. The reaction time of OWMT was the fastest in yellow and the accuracy degree of memory task was the highest in blue. For physiological parameters, we measured electrocardiogram(ECG) and HRV spectrum analysis, HF/LF color environment. These results can be used as an indicator in the design of color environment and clinical applications.

Correlation between Visual Sensibility and Vital Signal using Wearable based Electrocardiogram Sensing Clothes (웨어러블 기반의 심전도 측정 의복을 이용한 시각감성과 생체신호간의 상관관계)

  • Chung, Kyung-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.496-503
    • /
    • 2009
  • In the life environment changed with not only the material abundance but also the quality, it is the most crucial factor for the strategy of sensibility engineering to investigate vital signal according to the sensibility. In this perspective, it is necessary to design and merchandise the products in cope with each sensibility and needs as well as its functional aspects. In this paper, we proposed the correlation between the visual sensibility and the vital signal using the wearable based electrocardiogram sensing clothes. We measured the electrocardiogram (ECG) signal by wearing the electrocardiogram sensing clothes. The heart rate variability (HRV) is calculated form the acquired ECG signal by wearing the electrocardiogram sensing clothes. And the power spectrum analysis using the Fast Fourier Transform (FFT) is evaluated the correlation between the visual sensibility and the vital signal. we plan to conduct empirical applications to verify the adequacy and the validity of the proposed method.