• Title/Summary/Keyword: HR Plate

Search Result 149, Processing Time 0.031 seconds

A Study on Reaction Characteristics for NOx Reduction in Flue Gas Denitrification using Plasma (플라즈마 배연탈질에서 NOx 저감에 관한 반응제 특성 연구)

  • Baek, Hyun Chang;Shin, Dae Hyun;Woo, Je Kyung;Kim, Sang Guk;Kim, Dong Chan;Park, Yeong Seong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2247-2254
    • /
    • 2000
  • This study was carried out to investigate the reaction characteristics of NOx with reagents to grope the power consumption rate reduction and NOx removal rate improvement for the non-thermal plasma denitrification process. The experiments were performed using the real flue gas and wire-plate type plasma reactor. and the flow rate of real flue gas is $20Nm^3/hr$. Paraffinic and olefinic hydrocarbons and ammonia were used as reagents. Olefinic hydrocarbon oxidizes NO more actively than paraffinic hydrocarbon under the non-thermal plasma conditions, resulting in the generation of large amount of $NO_2$ and a very small amount of CO. When the initial NOx concentration increases. oxidation rate of NO decreases and the consumption rate of olefinic hydrocarbon increases significantly. On the other hand. $NH_3$ did not promote reduction reaction with NO under non-thermal plasma conditions. however, there was a tendency that the NHa was effective to remove the $NO_2$ oxidized by olefinic hydrocarbon.

  • PDF

Production of Standard Sample for Quality Control of Total Coliform (총대장균군 측정의 정도관리에 적합한 균주의 조제)

  • Kim, Ju-Young;Seo, Eun-Young;Kim, Mi-Ree;Jeon, Nam-Hui;Chung, Hyen-Mi;Kim, Myeong-Woon;Ahn, Tea-Seok
    • Korean Journal of Microbiology
    • /
    • v.44 no.1
    • /
    • pp.43-48
    • /
    • 2008
  • Standard sample for quality control of total coliform measurement was procured by addition of nalidixic acid and cephalexin as bacteriostatic agents to Escherichia coli cultured broth. After making the standard sample, the number of E. coli was measured by fluorescence microscopic count method and plate count method by 12 hr interval. The numbers of E. coli remained unchanged for at least for 48 hr at room temperature which ranged from 3.5 to $4.2{\times}10^5\;cells/ml$ and from 1.0 to $1.2{\times}10^4\;CFU/ml$ by direct fluorescence microscopic count method and plate count method, respectively. This result suggests that microbial standard sample with bacteriostatic agents of nalidixic acid and cephalexin is usable for quantitative quality control.

Single crystal growth of potassium lithium niobate for nonlinear optics (비선형광학재료 Potassium lithium niobate 단결정 육성)

  • 강길영;윤종규
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.3
    • /
    • pp.384-392
    • /
    • 1997
  • Potassium lithium niobate(KLN) single crystal for a nonlinear-optic material, which changes the wavelength of lasers, has a ferroelectric tetragonal tungsten bronze structure at room temperature. It has been very hard to get single crystals of good quality due to the cracks during cooling process. In order to investigate the composition change due to the evaporation of solution during the growth, the thermogravimetric analysis was carried out. In atmospheric condition at $1000^{\circ}C$ which is about $10^{\circ}C$ higher than the crystal growing temperature, the weight change was negligible amount of $1.46{\times}10^{-5}$g/($\textrm{cm}^2$hr). By using both the Pt plate as the nucleation site and the slow cooling method with temperature fluctuation, KLN single crystal of good quality of size 1 cm could be obtained. The phase transition temperature was $490^{\circ}C$, which was higher than that reported by other researchers of the other composition. The optical anisotropy due to the absorption of OH-band exists in the range of IR.

  • PDF

Formation and Chemical Characteristics of Dewfall in Western Busan Area (부산 서부지역의 이슬 생성과 화학적 특성)

  • Jeon Byung-Il;Hwang Yong-Sik;Park Moon-Po
    • Journal of Environmental Science International
    • /
    • v.13 no.12
    • /
    • pp.1079-1088
    • /
    • 2004
  • In order to understand chemical characteristics and dewfall formation in western Busan area, we analysed monthly distribution of dewfall, and investigated the correlation between dewfall formation amount and meteoro­logical factors. This study used the modified teflon plate $(1m{\times}1m)$ at Silla university in Busan from August 2002 to April 2003. In order to estimate qualitatively water soluble components, IC, ICP and UV methods for water soluble ions are also used respectively. Dewfall amount of sampling periods (47 day) collected 3.8 mm. Meteorological conditions for the formation of dewfall above $50\;g/m^{2}$ showed that temperature diurnal $range(^{\circ}C)\;was\;5.6^{\circ}C$ above, cloud amounts (1/10) at dawn of the sampling day was 7/10 below, mean wind speed at dawn (0~6hr) of the sampling day was 4.4 m/sec below, and mixing ratio at 6hr of the sampling day was 3.2 g/kg above. Distribution of water soluble ions in dewfall founded the highest concentration (206.1\;{\mu}eq/{\ell}\;for\;SO_{4}^{2-},\;42.4\;{\mu}eq/{\ell}\;for\;NH_{4}^{+},\;249.2\;{\mu}eq/{\ell}\;for\;Ca^{2+},\;and\;42.0\;{\mu}eq/{\ell}\;for\;Mg^{2+})$ during the March, the lowest concentration $(73.0\;{\mu}eq/{\ell}\;for\;SO_{4}^{2-},\;4.6\;{\mu}eq/{\ell}\;for\;NH_{4}^+\;and\;72.7\;{\mu}eq/{\ell}\;for\;Ca^{2+})$ during the August. Monthly equivalent ratio of $[SO_{4}^{2-}]/[NO_{3}^-]$ showed the highest value (4.99) during the October, the lowest value (1.84) during the August, and the mean value was 3.45.

Inhibition of Clinical Nosocomial Bacteria by Chlorine Dioxide

  • Jung, Suk-Yul
    • Biomedical Science Letters
    • /
    • v.25 no.4
    • /
    • pp.431-435
    • /
    • 2019
  • Chlorine dioxide is an effective chemical to inhibit the growth of bacteria and viruses or to disinfect infected areas. In this study, the effects of chlorine dioxide on several bacteria in hospitals were analyzed. Alloiococcus otitis, Kocuria rosea, Leuconostoc mesenteroides spp. and Staphylococcus lentus as gram-positive bacteria and Acinetobacter lwoffii, Aeromonas salmonicida, Brucella melitensis, Oligella ureolytica as gram-negative bacteria were done for the inhibitory analysis. The growth and morphology of the bacteria were analyzed by placing a plastic stick which was called "FarmeTok (medistick/Puristic)" provided by Purgofarm, co, Ltd. to release ClO2 (13 ppmv/hr) next to the plate where the bacteria were incubated for 24 hours. Less than 10 bacterial colonies were evaluated as having 99% inhibitory effect. The initial bacterial culture concentration of 0.5 McFaland turbidity was good for analyzing the chlorine dioxide inhibitory effect. All bacteria could be easily counted post 24 hr co-incubation with ClO2, but A. otitis and A. lwoffii without ClO2 gas were not countable due to very dispersed colony types which were not affected for result analysis. As shown in this study, the FarmeTok plastic stick, which discharges chlorine dioxide at 13 ppmv / hour, was evaluated to be sufficient to suppress the above bacteria in the hospital. Bacteria existing in the clinic such as this hospital will be used as a data to inhibit the growth of bacteria by using ClO2, and molecular biology analysis using the gene of bacteria will be possible in the future rather than inhibiting the growth of bacteria itself.

The effect of Heat input and PWHT on the microstructure and mechanical properties of HSB600 steel weldments (HSB600강 GMA 용접부에서 입열량과 용접후 열처리가 미세조직과 기계적 특성에 미치는 영향)

  • Koh, Jin-Hyun;Kim, Nam-Hoon;Jang, Bok-Su;Ju, Dong-Hwi;Lim, Young-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5405-5411
    • /
    • 2011
  • The effects of heat input (1.5~3.6 kJ/mm) and post weld heat treatment (PWHT, $600^{\circ}C$, 40hr.) on the TMCP HSB600 steel weldments made by GMAW process were investigated. The tensile strengths and hardness of as-welded specimens were decreased as heat input increased, but CVN (Charpy V-Notch) impact energy did not show any differences. The fine-grained acicular ferrite was mainly formed in the low heat input while polygonal and side plate ferrites were dominated in the high heat inputs. Meanwhile, tensile strength and hardness of PWHT weldments were decreased due to the coarsening and globular of microstructure as well as reduction of residual stresses.

Application of Microwave Digestion Pretreatment Techniques for ICP-AES Analysis of Used Monolithic Automobile Catalysts Having Platinum Group-Metals and Silicates (백금족 금속과 규산염을 포함하는 모노리스형 자동차 폐촉매의 ICP-AES 분석을 위한 극초단파 분해 전처리 기법의 응용)

  • Kim, Choong-Hyon;Woo, Seong Ihl;Jeon, Sung Hwan
    • Applied Chemistry for Engineering
    • /
    • v.10 no.4
    • /
    • pp.568-575
    • /
    • 1999
  • Two different digestion procedures for the simultaneous determination of major and platinum-group element(PGE) in spent automobile catalysts containing PGE and silicates by inductively coupled plasma atomic emission spectrometry(ICP-AES) are compared. Combinations of mixed aids using HF, $HNO_3$, HCl, $HClO_4$, $H_2O_2$, and $H_3BO_3$ are utilized for the hot plate dissolution method and the closed-vessel microwave digestion method, The latter method has been shown to be relatively superior in terms of recovery, analysis time, and amount of aqua regia (3 parts HCl + part $HNO_3$ required to dissolve PGE in comparison with conventional open vessel hot-plate dissolution. The best results were drawn from the following conditions: In closed Teflon PFA vessels under microwave heating with temperature/pressure regulation, a 0.25 g portion of sample was digested in 2 mL of HF, 2 mL of $HNO_3$ and 6mL of HCl under the pressure of 200 psi(13.79 bar) at $180^{\circ}C$ for 1hr, followed by a second digestion stage with 16 mL of 5%(w/v) boric acid under the pressure of 20 psi(1.38 bar) at $100^{\circ}C$ for 10 min. After the microwave heating, the sample was post-treated with 10 mL of aqua regia twice by hot-plate heating. This condition gives the PGE recovery within 85~110% and the relative standard deviations within 2%. The method developed can therefore be regarded as an alternative method for routine analysis of spent automobile catalysts.

  • PDF

The Fermentative Characteristics of Cheonggukjang Prepared by Starter Culture of Bacillus spp. with Fibrinolytic Activity (혈전용해활성이 우수한 Bacillus spp. 스타터를 이용한 청국장의 발효특성)

  • Hwang, Jong-Hyun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.12
    • /
    • pp.1832-1838
    • /
    • 2010
  • The objective of this study was to improve the flavor of Cheonggukjang prepared by the culture optimization of starter with the fibrinolytic activity. After 25 strains isolated from the commercial Cheonggukjang and Doenjang in different regions were compared, 7 Bacillus strains with proteolytic and slime-producing activities were selected. When the fibrin plate method for fibrinolytic activity was applied, CJJN-4 and 5 showed the higher activity in tripticase soy broth (TSB). All Cheonggukjang prepared with CJJN-4 and 5 also had the fibrinolytic activity, regardless of culture temperature or time. Especially, Cheonggukjang prepared at $40^{\circ}C$ showed higher activity than $45^{\circ}C$, and Cheonggukjang prepared with CJJN-4 for 48 hr at $40^{\circ}C$ showed the highest fibrinolytic activity. Although there was no significant difference in pH of Cheonggukjang prepared with CJJN-4 or 5 during 72 hr at $40^{\circ}C$, Cheonggukjang prepared with CJJN-4 at $45^{\circ}C$ had lower pH until 60 hr than $40^{\circ}C$ or CJJN-5. The total amino type nitrogen contents of Cheonggukjang were 1,139.6 (CJJN-4) and 1,027.6 mg% (CJJN-5) for 72 hr at $40^{\circ}C$, and their producing rates were also higher at $40^{\circ}C$ fermentation than $45^{\circ}C$. Meanwhile, the contents of ammonia type nitrogen induced unpleasant flavor were lower in Cheonggukjang with CJJN-4 and 5 at $40^{\circ}C$ than CJJN-5 at $45^{\circ}C$. Therefore, Cheonggukjang fermented with CJJN-4 starter at $40^{\circ}C$ had the improved flavor, such as change of amino or ammonia type nitrogen production, and higher fibrinolytic activity.

Performance Analysis of Double-Glazed Flat Plate Solar Collector with Cu-based Solar Thermal Absorber Surfaces

  • Lee, Jeong-Heon;Jeong, Da-Sol;Nam, Yeong-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.157.1-157.1
    • /
    • 2016
  • In this work, we experimentally investigated the solar absorption performance of Cu-based scalable nanostructured surfaces and compared their performance with the conventional TiNOX. We fabricated Cu-based nanostructured surfaces with a controlled chemical oxidation process applicable to a large area or complex geometry. We optimized the process parameters including the chemical compounds, dipping time and process temperature. We conducted both lab-scale and outdoor experiments to characterize the conversion efficiency of each absorber surfaces with single and double glazing setup. Lab-scale experiment was conducted with $50mm{\times}50mm$ absorber sample with 1-sun condition (1kW/m2) using a solar simulator (PEC-L01) with measuring the temperature at the absorber plate, cover glass, air gap and ambient. From the lab-scale experiment, we obtained ${\sim}91^{\circ}C$ and $94^{\circ}C$ for CuO and TiNOX surfaces after 1 hr of solar illumination at single glazing, respectively. To measure the absorber performance at actual operating condition, outdoor experiment was also conducted using $110mm{\times}110mm$ absorber sample. We measured the solar flux with thermopile detector (919P-040-50). From outdoor experiment, we observed ${\sim}123^{\circ}C$ and $131^{\circ}C$ for CuO and TiNOX with 0.6 kW/m2 insolation at double glazing, respectively. We showed that the suggested nanostructured CuO solar absorber has near-equivalent collection efficiency compared with the state-of-the-art TiNOX surfaces even with much simpler manufacturing process that does not require an expensive equipment.

  • PDF

Basic Study on Quality Evaluation Technique for Peeled Garlics(I) -Rotation sytem for vision-based garlic sorter- (박피 마늘의 품위판정 기술개발에 관한 기초연구(I) -영상식 마늘 선별기용 반전장치 개발-)

  • 이종환;이성범;안청운
    • Journal of Biosystems Engineering
    • /
    • v.26 no.3
    • /
    • pp.271-278
    • /
    • 2001
  • Many workers in the garlic peeling factory are separating the sound peeled garlics from the unpeeled and defective ones in a manual way. In order to reduce the seasonal labor requirement and operating cost, the mechanized garlic sorting system such as the vision-based garlic sorter should be developed. This study was conducted as one of basic studies on developing quality evaluation technique for peeled garlics, especially to developed the system for acquiring the whole surface images of garlics with a CCD camera. The following results were obtained from this study. 1. The belt-type garlic rotation system was devised to apply for the vision-based garlic sorter and was tested to decide the criteria of design and optimum conveying speed. 2. To evaluate the performance of the developed garlic rotation system, feeding rate and rotating rate were measured under the conditions of four experimental factors such as the inclined angle of rotating belt, the inclined angle of feeding belt, the height of plate arrays on feeding belt and the conveying speed of belts. And the capacity of the system according to mixture ratios of peeled garlics and unpeeled garlics was analyzed as a feasibility test. 3. For the inclined angle of rotating belt 20°and height of plate array on feeding belt 22㎜, the maximum rotating rate for garlic samples including unpeeled ones was 81.1% at the conveying speed of 4.2 garlic/sec. And under these condition, the maximum feeding rate was 85% at the inclined angle of feeding belt 6.5°. 4. The capacity of the developed garlic rotation system was almost constant regardless of mixture ratio of peeled garlics and unpeeled garlics and its range was 2.95∼3.92 garlic/sec. At the conveying speed of 4.2 garlic/sec, the capacity of the garlic rotation system was calculated ad 58∼64 kg/hr. 5. To improve performance of the garlic rotation system, it is recommended to develop a device to slide garlics into feeding belt.

  • PDF