• Title/Summary/Keyword: HPS

Search Result 153, Processing Time 0.022 seconds

An Experimental Study on Motor Noise Reduction of Electric Power Steering (전동식 파워스티어링 모터소음 저감을 위한 실험적 연구)

  • You, C.J.
    • Journal of Power System Engineering
    • /
    • v.12 no.6
    • /
    • pp.83-87
    • /
    • 2008
  • EPS(Electric Power Steering) system, which has replaced the hydraulic steering system(HPS or HPAS) in many passenger cars recently, have many merits such as low energy consumption, easy mounting, light weight and improvement of environmental pollution. However, EPS system has the problem of motor noise when motor is rotated, which can make a driver feel uncomfortable. There are many techniques to solve those problems, but they are not clear. It is necessary to evaluate the mechanical noise in steering systems, because an EPS has vibration sources such as at the motor gear reducer, manual gears and intermediate joints. In this paper, reduction technique of EPS motor noise is introduced.

  • PDF

차세대 HPS(Hybrid Positioning System) 기술동향 및 향후 전망

  • Kim, Sang-Il;Kim, Hwan-Gi;Lee, Gwon-U;Kim, Hwa-Seong
    • Information and Communications Magazine
    • /
    • v.28 no.7
    • /
    • pp.44-51
    • /
    • 2011
  • 최근 GPS(Global Positioning System)가 탑재된 스마트 단말이 빠르게 보급되면서 위치정보 기반의 다양한 서비스가 보급되고 있다. 위치정보는 다양한 맥락으로 해석 및 적용될 수 있으며, 교통, 군사, 공공안전 등 여러 분야에 걸쳐 광범위하게 사용되고 있다. 이에 따라 위치정보의 정확도 향상을 위한 다양한 연구가 활발히 진행 중인데, 실외 환경의 경우 GPS를 이용한 고정밀 측위 기술이 주류를 이루고 있는 반면에, 실외 환경보다 상대적으로 제약이 많은 실내 환경에서는 주로 네트워크 기반의 측위 기술에 대한 연구가 많이 이루어지고 있다. 본고에서는 기존의 측위 기술들의 장단점을 분석하고, 각 측위 기술의 단점을 보완한 복합 측위 기술 동향을 알아보고 향후 복합 측위 기술의 발전 방향에 대해 논의한다.

Power Factor improvement of Power Conversion Equipment for High Pressure Sodium Lamps (고압 나트륨 램프 구동용 전력변환장치의 역률 개선)

  • Lee, S.H.;Suh, K.Y.;Lee, H.W.;Lee, S.H.;Mun, S.P.
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.147-150
    • /
    • 2002
  • HPSL(High Pressure Sodium lamp)have attracted much attention in recent years, because they offer high luminous efficiency and very long life. Recently, AC-DC converters have been widely as power factor improvement circuits in the power conversion equipment An application of the ZVT-PWM(Zero Voltage Transition Pulse Width Modulation) boost converter, which has great advantage on miniaturization and high power density, to the power factor improvement circuit of the HPSL inverter are described to identify the power factor correction characteristics of the inverter. In this paper the series-parallel resonant inverter(electronic ballast) for driving a HPS lamp is discussed. Finally, a power factor corrector is cascaded in front of the electronic ballast. Consequently, a high power factor above 0.99 and low THD on the line current can be achieved.

  • PDF

Cloning and Expression of Nucleocapsid Genes of Hantaviruses in Escherichia coli (대장균에서 한타바이러스 뉴클레오캡시드 유전자의 발현에 관한 연구)

  • 노갑수;하석훈;김종완;홍선표;김형배;최차용
    • KSBB Journal
    • /
    • v.13 no.6
    • /
    • pp.649-655
    • /
    • 1998
  • Hantaviruses are rodent hosts-borne viruses belonging to the family Bunyaviridae, and are etiologic agents for two acute diseases, i.e., Haemorrhagic Fever with Renal Syndrome (HFRS) and Hantavirus Pulmonary Syndrome (HPS). There have been a lot of reports on prophylactic vaccines and diagnostics for the diseases, but most of viral antigens have been prepared by eukaryotic cell culture. Nucleocapsid proteins of Hantaviruses are known as the major viral antigens. Thereby, we prepared nucleocapsid genes of Hantaan virus and Seoul virus by RT-PCR and cloned into plasmid vectors, pET-3a and pKK223-3. Both genes were expressed in Escherichia coli with higher expression level of Seoul viral nucleocapsid protein compared to that of Hantaan in pET-3a. Hantaan viral gene was expressed much higher level in plasmid pET-3a that in pKK223-3. About 30% of expressed nucleocapsid protein was soluble and the rest was remained in insoluble fraction.

  • PDF

A Study on the Application of Two-dosimeter Algorithm to Estimate the Effective Dose in an Inhomogeneous Radiation Field at Korean Nuclear Power Plants (원전 불균일 방사선장하에서 유효선량 평가를 위한 복수선량계 알고리즘 적용방안 연구)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.4
    • /
    • pp.151-160
    • /
    • 2008
  • In Korean nuclear power plants (NPPs), two thermoluminescent dosimeters (TLD) were provided to workers who work in an inhomogeneous radiation field; one on the chest and the other on the head. In this way, the effective dose for radiation workers at NPPs was determined by the high deep dose between two radiation dose from these TLDs. This represented a conservative method of evaluating the degree of exposure to radiation. In this study, to prevent the overestimation of the effective dose, field application experiments were implemented using two-dosimeter algorithms developed by several international institutes for the selection of an optimal algorithm. The algorithms used by the Canadian Ontario Power Generation (OPG) and American ANSI HPS N13.41, NCRP (55/50), NCRP (70/30), EPRI (NRC), Lakslumanan, and Kim (Texas A&M University) were extensively analyzed as two-dosimeter algorithms. In particular, three additional TLDs were provided to radiation workers who wore them on the head, chest, and back during maintenance periods, and the measured value were analyzed. The results found no significant differences among the calculated effective doses, apart from Lakshmanan's algorithm. Thus, this paper recommends the NCRP(55/50) algorithm as an optimal two-dosimeter algorithm in consideration of the solid technical background of NCRP and the convenience of radiation works. In addition, it was determined that a two-dosimeter is provided to a single task which is expected to produce a dose rate of more than 1 mSv/hr, a difference of dose rates depending on specific parts of the body of more than 30%, and an exposure dose of more than 2 mSv.

Biodegradation of Polynuclear Aromatic Hydrocarbons in soil using microorganisms under anaerobic conditions (혐기성 미생물에 의한 토양내 다핵성방향족화합물의 생물학적 분해)

  • An, Ik-Seong
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.89-91
    • /
    • 2000
  • Polynuclear aromatic hydrocarbon (PAH) compounds are highly carcinogenic chemicals and common groundwater contaminants that are observed to persist in soils. The adherence and slow release of PAHs in soil is an obstacle to remediation and complicates the assessment of cleanup standards and risks. Biological degradation of PAHs in soil has been an area of active research because biological treatment may be less costly than conventional pumping technologies or excavation and thermal treatment. Biological degradation also offers the advantage to transform PAHs into non-toxic products such as biomass and carbon dioxide. Ample evidence exists for aerobic biodegradation of PAHs and many bacteria capable of degrading PAHs have been isolated and characterized. However, the microbial degradation of PAHs in sediments is impaired due to the anaerobic conditions that result from the typically high oxygen demand of the organic material present in the soil, the low solubility of oxygen in water, and the slow mass transfer of oxygen from overlying water to the soil environment. For these reasons, anaerobic microbial degradation technologies could help alleviate sediment PAH contamination and offer significant advantages for cost-efficient in-situ treatment. But very little is known about the potential for anaerobic degradation of PAHs in field soils. The objectives of this research were to assess: (1) the potential for biodegradation of PAH in field aged soils under denitrification conditions, (2) to assess the potential for biodegradation of naphthalene in soil microcosms under denitrifying conditions, and (3) to assess for the existence of microorganisms in field sediments capable of degrading naphthalene via denitrification. Two kinds of soils were used in this research: Harbor Point sediment (HPS-2) and Milwaukee Harbor sediment (MHS). Results presented in this seminar indicate possible degradation of PAHs in soil under denitrifying conditions. During the two months of anaerobic degradation, total PAH removal was modest probably due to both the low availability of the PAHs and competition with other more easily degradable sources of carbon in the sediments. For both Harbor Point sediment (HPS-2) and Milwaukee Harbor sediment (MHS), PAH reduction was confined to 3- and 4-ring PAHs. Comparing PAH reductions during two months of aerobic and anaerobic biotreatment of MHS, it was found that extent of PAHreduction for anaerobic treatment was compatible with that for aerobic treatment. Interestingly, removal of PAHs from sediment particle classes (by size and density) followed similar trends for aerobic and anaerobic treatment of MHS. The majority of the PAHs removed during biotreatment came from the clay/silt fraction. In an earlier study it was shown that PAHs associated with the clay/silt fraction in MHS were more available than PAHs associated with coal-derived fraction. Therefore, although total PAH reductions were small, the removal of PAHs from the more easily available sediment fraction (clay/silt) may result in a significant environmental benefit owing to a reduction in total PAH bioavailability. By using naphthalene as a model PAH compound, biodegradation of naphthalene under denitrifying condition was assessed in microcosms containing MHS. Naphthalene spiked into MHS was degraded below detection limit within 20 days with the accompanying reduction of nitrate. With repeated addition of naphthalene and nitrate, naphthalene degradation under nitrate reducing conditions was stable over one month. Nitrite, one of the intermediates of denitrification was detected during the incubation. Also the denitrification activity of the enrichment culture from MHS slurries was verified by monitoring the production of nitrogen gas in solid fluorescence denitrification medium. Microorganisms capable of degrading naphthalene via denitrification were isolated from this enrichment culture.

  • PDF

An Assessment of Air Sampling Location for Stack Monitoring in Nuclear Facility (원자력시설 굴뚝 내 공기시료채취 위치의 적절성 평가)

  • Lee, JungBok;Kim, TaeHyoung;Lee, JongIl;Kim, BongHwan
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.2
    • /
    • pp.173-180
    • /
    • 2017
  • In this study, air sampling locations in the stack of the Advanced Fuel Science Building (AFSB) at the Korea Atomic Energy Research Institute (KAERI) were assessed according to the ANSI/HPS N13.1-1999 specification. The velocity profile, flow angle and $10{\mu}m$ aerosol particle profile at the cross-section as functions of stack height L and stack diameter D (L/D) were assessed according to the sampling location criteria using COMSOL. The criteria for the velocity profile were found to be met at 5 L/D or more for the height, and the criteria for the average flow angle were met at all locations through this assessment. The criteria for the particle profile were met at 5 L/D and 9 L/D. However, the particle profile at the cross-section of each sampling location was found to be non-uniform. In order to establish uniformity of the particle profile, a static mixer and a perimeter ring were modeled, after which the degrees of effectiveness of these components were compared. Modeling using the static mixer indicated that the sampling locations that met the criteria for the particle profile were 5-10 L/D. When modeling using the perimeter ring, the sampling locations that met the criteria for particle profile were 5 L/D and 7-10 L/D. The criteria for the velocity profile and the average flow angle were also met at the sampling locations that met the criteria for the particle profile. The methodologies used in this study can also be applied during assessments of air sampling locations when monitoring stacks at new nuclear facilities as well as existing nuclear facilities.

Effect of Supplemental Lighting of Sub-Compensation Intensities on Growth of Rosa hybrida L. 'Vital' (광보상점 이하의 보광이 절화장미 'Vital'의 생육에 미치는 영향)

  • Choi, Young-Hah;Kwon, Joon-Kook;Choi, Gyeong-Lee;Kang, Nam-Jun;Chun, Hee;Cho, Myeong-Whan;Seo, Tae-Cheol;Roh, Mi-Young;Lee, Seong-Chun;Lee, Jae-Han
    • Journal of Bio-Environment Control
    • /
    • v.17 no.2
    • /
    • pp.132-137
    • /
    • 2008
  • This experiment was conducted to investigate the effect of supplemental lighting of low light intensities on growth and yield of rose 'Vital' in a forcing culture. Metal halide lamp (MH), High pressure sodium lamp (HSP), and MH+HSP were used as the light sources, and they were set up at a $310\;cm{\times}450\;cm$ interval and at 120cm above the culture beds. Light intensity at 1m point distance from supplemental lighting sources was $32{\sim}34\;{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. Days to the 1st and 2nd harvests decreased by $5{\sim}8$ and $3{\sim}5$days, respectively in supplemental lighting treatment as compared to the control. Days to harvesting was the shortest in MH+HPS treatment, followed by BPS and MH, although there was no significant difference between HPS and MH treatments. The growth was better and incidence of blind shooting decreased by $5{\sim}7%$ in supplemental lighting treatments than the control, increasing marketable cut flowers. The incidence of blind shoot was the lowest in MH+BPS treatment, and there were no significant difference between MH and BPS treatments. In conclusion, supplemental lighting of low light intensities was effective in reducing days to flowering and reduced occurrence of blind shoots.

Cloning and Expression of the Pasteurella haemolytica A1 leukotoxin Gene in Bacillus subtilis (Bacillus subtilis을 이용한 Pasteurella haemolytica A1 leukotoxin 유전자의 cloning 및 발현)

  • Yoo, Han-sang;Maheswaran, Samuel K.
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.3
    • /
    • pp.665-680
    • /
    • 1996
  • Bovine Pneumonic Pasteurellosis는 수송열(輸送熱)로 일반적으로 알려져 있는 질병으로서, 여러가지 요인의 복합적(複合的)인 작용에 의해 발병하는 것으로 알려져 있으나, Pasteurella haemolytica A1이 가장 주요(主要)한 인자(因子)로 밝혀져 있다. P haemolytica A1은 leukotoxin(LKT), lipopolysaccharide(LPS), capsular polysaccharide 등 여러가지의 병원성인자(病原性因子)을 생성한다. 이들 인자중 LKT가 가장 중요한 병원성인자로 밝혀져 있다. 이에 본 실험은 P haemolytical A1의 LKT 유전자를 Bacillus subtilis에서 발현(發現)시킴으로서 LPS에 오염(汚染)되지 않은 LKT을 대량으로 생산할 목적으로 실시되었다. 실험의 첫 단계(段階)로서 pLKT52 plasmid을 Sau3 A1의 제한효소을 이용하여 부분소화(部分消化)시킨 후 이 부분 소화(消化)된 유전자들로부터 3~5kb 크기의 유전자들을 순수분리하여 pUC18와 결합시킨 후 E coli NM522에 형질전환(形質轉換)시켰다. 이때 형질전환된 균주들은 LKT에 대한 단크론 항체인 MAb601을 이용하여 colony blot 법에 의해서 LKT 유전자 보유 및 발현여부(發現與否)을 조사하였다. 이들 양성 clone들은 제한효소분석(制限酵素分析), 염기서열분석(鹽基序列分析) 및 Western blot 등에 의해서 재확인(再確認)하였다. 총 9개의 양성 clone중 위의 방법에 의해서 한 clone을 선택(選擇)하여 lktCA insert를 재분리하여 shuttle vector에 subcloning 하였다. Subcloning된 LKT 유전자들은 shuttle vector의 종류(種類)(pHPS9, p602/20, pHPS9-Sac)와 각기(各其) 다른 종류(種類)의 B subtilis(spoO12A, BR121, WB3O, Raj1105) 숙주내(宿主內)에서 발현정도를 Western blot 법에 의해서 비교(比較)하였다. 이때 최적발현조건(最適發現條件)은 p602/20와 pBL1의 dual plasmid system을 이용하여 B subtilis spoO12A에서 2시간동안 IPTG로 발현을 유도(誘導)하는 것이었다. B subtilis에서 발현된 LKT을 visual 법과 neutral red uptake 법을 이용하여 소 폐포(肺胞) 대식구(大食求)에 대한 biological activity를 확인하였다. 발현된 LKT에 대한 LPS 오염은 LKT을 SDS-PAGE 후 silver stain에 의해서 확인하였다. 본 실험을 통해서 볼 때에 lktCA 유전자를 보유(保有)하고 있는 p602/20는 B subtilis에서 매우 불안정(不安定)하였고, 발현된 LKT는 세균자체(細菌自體)에서 생성되는 protease들에 의해서 파괴(破壞)됨으로서 농도(濃度)가 매우 낮았다. 이러한 문제점들은 다음 단계(段階)의 실험에서 해결되어야할 문제들이다.

  • PDF

GVT, Inc.의 HP Series 2단 Gifford-McMahon 극저온 냉동기 성능시험

  • Lee, Dong-Ju;Han, Myeong-Hui;Mun, Jae-Yeong;In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.227-227
    • /
    • 2012
  • Cryopump는 반도체 임플란타 공정, OLED분야, 신소재 개발, 표면분석 및 처리, 의료분야, 입자가속기, 핵융합 등 다양한 진공분야에 응용되는 고진공용 극저온펌프이다. 특히 향후로의 산업구조는 디스플레이, 반도체, IT 산업분야로 집중 재편될 것이기에, 이에 따른 핵심제조장비인 고진공 펌프의 수요가 급증할 것으로 판단된다. 그리고 이를 위한 핵심부품과 장비들의 국산화가 시급한 실정이다. 기술적인 측면에서 보자면 GVT는 미국의 Varian과 일본Ebara의 Cryopump 제조기술을 원천으로 한 회사로써 현재는 국내 유일의 G-M냉동기와 Cryopump 제조기술을 보유한 업체이다. 그리고 최근 오랫동안 정체되었던 관련 기술을 발전시켜 최적화된 한국형 G-M 냉동기 및 이를 장착한 다양한 사이즈의 고성능 Cryopump를 출시하게 되었다. 가장 큰 수확은 Cryopump의 성능을 크게 향상시켰으며 무엇보다 고객맞춤형으로 디자인할 수 있을 정도의 기술력을 확보하게 되었다는 점이다. Cryopump의 성능은 장착되는 Cryocooler(G-M냉동기)의 성능과 밀접한 관련이 있기 때문에 일차로 Cryocooler의 성능을 개선하고 이차로 이를 장착한 Cryopump의 성능을 개선하였다. 본 연구는 일차로 진행된 HP Series 2단 Cryocooler 4가지 모델 중 가장 범용인 HPM 모델과 HPS모델에 대한 제작과 성능시험에 관한 것이다. 이는 각각 기존의 ICP Series 펌프에 장착되던 Expander 535 모델 및 Expander 855 모델에 대한 설계 최적화의 결과물로써 내용은 Cryocooler에 대한 'Typical Performance Test(1st STG와 2nd STG의 온도가 각각의 Stage에 인가되는 Heat Load에 의해 그물망 형태의 그래프가 되도록 수행하는 시험법)'의 절차를 따라 수행되었다. HPM Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 80K를 Heat Load 기준으로 하였을 경우, 각각 8.2W, 55.0W의 성능을 나타내었고 HPS Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 72K를 Heat Load기준으로 하였을 경우, 각각 14.0W, 90.0W의 성능을 나타내었다. 1st STG Temp.를 72K로 정한 이유는 Power Supply의 용량 한계로 인해 90W이상의 Heat Load를 인가할 수 없었기 때문이다. 만약 성능 그래프의 경향성을 고려하여 1st STG Temp. 80K로 가정한다면, 각각 약 13W, 100W 정도의 성능을 가질 것으로 추정된다. 단, 본 시험에 사용된 Compressor는 GVT의 HC80Plus 모델로 내부에는 Helium용 5HP급 Scroll Type의 Compressor가 장착되어 있으며, 봉입압력 250Psig에 저압 100Psig기준, 65scfm의 유량을 가지는 압축기이다. 압축기와 Cryocooler의 조합은 1:1이었고 시험방법은 Cryocooler에 대한 GVT 자체규정에 따라 진행되었으며 밤과 낮 및 공장전체의 부하변동에 따른 냉각수 온도변화에 따른 펌프의 성능변화는 고려되지 않았다.

  • PDF