• Title/Summary/Keyword: HPLC-PDA method

Search Result 90, Processing Time 0.023 seconds

Development and Validation of HPLC-PDA Method and Pattern Recognition Analyses Using Eight Marker Compounds for the Quality Control Between the Seeds of Cuscuta chinensis Lam. and Cuscuta japonica Choisy

  • Nguyen, Duc Hung;Zhao, Bing Tian;Le, Duc Dat;Ma, Eun Sook;Min, Byung Sun;Woo, Mi Hee
    • Natural Product Sciences
    • /
    • v.25 no.4
    • /
    • pp.334-340
    • /
    • 2019
  • Cuscuta chinensis Lam. and Cuscuta japonica Choisy are parasitic plants. C. chinensis seeds were traditionally used for treatment of kidney and liver deficiencies. C. japonica seeds were used as tonic medicine to improve liver function and strengthen kidneys, treatment of high blood pressure, chronic diarrhea, and sore eyes. Cuscutae Semen are seeds of only C. chinensis in Korean Herbal Pharmacopoeia (K.H.P.). The developed HPLC-PDA method easily, accurately, and sensitively quantified using eight marker compounds [hyperoside (1), astragalin, (2), quercetin (3), kaempferol (4), chlorogenic acid (5), 3,4-di-O-caffeoylquinic acid (6), 1,5-di-O-caffeoylquinic acid (7), and 4,5-di-O-caffeoylquinic acid (8)]. In addition, the method may be used to distinguish seeds between C. chinensis Lam. and C. japonica Choisy. Furthermore, the result from the current study was applied to clarify samples between steam processed and unprocessed samples of C. chinensis by pattern analysis.

Determination of fucoxanthin in cosmeceutical products by HPLC-PDA (HPLC-PDA를 이용한 기능성 화장품 중 푸코잔틴의 정량)

  • Choi, Jongkeun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.755-761
    • /
    • 2017
  • This study was conducted to establish an analytical method using an HPLC system equipped with a photodiode array (PDA) detector for the quality control of raw materials and cosmeceuticals containing fucoxanthin as an active ingredient. The column was octadecyl-functionalized silica gel and the measurement wavelength of the PDA was set to 499 nm. To validate the analytical method, the linearity of the calibration curve, detection limit, reproducibility and recovery rate were investigated and good results were obtained. The correlation coefficient of the calibration curve was 1.000 and the linearity was good in the concentration range of 0.5 ~ 100 ppm. Moreover, the limit of detection (LOD) was 0.1 ppm and the limit of quantification (LOQ) was 0.5 ppm. The results of the peak reproducibility test used for evaluating the system suitability showed that the RSD (n = 5) of the peak area was 2.0% and that of the retention time was 0.09%. In the spiking test, the recovery rate was $101.6{\pm}0.77%$. The fucoxanthin contents of the two kinds of fucoxanthin-containing raw materials were $49.6{\pm}3.3%$ and $1.03{\pm}0.016%$, respectively. In addition, the fucoxanthin content in the test product, which was intended to be 150 ppm, was $156.7{\pm}4.7ppm$. From the above results, it was concluded that this method could be applied to the quantitative analysis of fucoxanthin in cosmeceuticals.

Simultaneous Determination of Seven Compounds in Samsoeum by HPLC-PDA

  • Seo, Chang-Seob;Kim, Jung-Hoon;Huang, Dae-Sun;Shin, Hyeun-Kyoo
    • Herbal Formula Science
    • /
    • v.18 no.1
    • /
    • pp.95-103
    • /
    • 2010
  • Objectives : To develop and validate HPLC-PDA methods for simultaneous determination of seven constituents in Samsoeum(SSE). Methods : Reverse-phase chromatography using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array(PDA) detection at 254 and 280 nm, were used for quantification of the seven marker components of SSE. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. Results : Calibration curves were acquired with $r^2$>0.9997, and the relative standard deviation (RSD) values (%) for intra- and inter-day precision were less than 3.0%. The recovery rate of each compound was in the range of 100.07-112.65%, with an RSD less than 4.0%. The contents of seven compounds in SSE were 1.24-10.53 mg/g. Conclusions : The established method will be helpful to improve quality control of SSE.

Simultaneous Determination of Seven Compounds by HPLC-PDA and Cytotoxicity of Samchulkunbi-tang (삼출건비탕의 HPLC-PDA 동시 분석법 설정 및 세포독성)

  • Seo, Chang-Seob;Lee, Mee-Young;Kim, Jung-Hoon;Lee, Jin-Ah;Shin, Hyeun-Kyoo
    • The Korea Journal of Herbology
    • /
    • v.25 no.3
    • /
    • pp.65-71
    • /
    • 2010
  • Objectives:To develop and validate HPLC-PDA methods for simultaneous determination of seven constituents in Samchulkunbi-tang (SKT). Additionally, we investigated the cytotoxicity against BEAS-2B cell line and splenocytes of SKT. Methods:Reverse-phase chromatography using a Gemini $C_{18}$ column operating at $40^{\circ}C$, and photodiode array (PDA) detection at 230, 254 and 280 nm, were used for quantification of the three marker components of SKT. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. The cytotoxicity of SKT were measured by the CCK-8 assay method. Results:Calibration curves were acquired with $r^2$>0.9999, and the relative standard deviation (RSD) values (%) for intra- and inter-day precision were less than 6.0%. The recovery rate of each compound was in the range of 86.89-109.78%, with an RSD less than 4.0%. The contents of seven compounds in SKT were 1.39-6.84 mg/g. SKT had no cytotoxicity effect at 50-200 ${\mu}g$/mL concentrations. Conclusions:The established method will be helpful to improve quality control and in vitro efficacy study of SKT.

Quantitation and Radical Scavenging Activity Evaluation of Iridoids and Phenylethanoids from the Roots of Phlomis umbrosa (Turcz.) using DPPH Free Radical and DPPH-HPLC Methods, and their Cytotoxicity

  • Le, Duc Dat;Nguyen, Duc Hung;Zhao, Bing Tian;Min, Byung Sun;Song, Si Whan;Woo, Mi Hee
    • Natural Product Sciences
    • /
    • v.25 no.2
    • /
    • pp.122-129
    • /
    • 2019
  • The roots of Phlomis umbrosa (Turcz.) (Phlomidis Radix) have been traditionally used to treat cold, reduce swelling and staunch bleeding. Four iridoids (1 - 3 and 5) and six phenylethanoid derivatives (4, and 6 - 10) were isolated from the roots of P. umbrosa. A simple, sensitive, and reliable analytical HPLC/PDA method was developed, validated, and applied to determine 10 marker compounds in Phlomidis Radix. Furthermore, the isolates were evaluated for cytotoxic and anti-oxidant activities as well as DPPH-HPLC method. Among them, compounds 4 and 6 - 9 displayed potent anti-oxidant capacities using DPPH assay with $IC_{50}$ values of $27.7{\pm}2.4$, $10.2{\pm}1.1$, $18.0{\pm}0.8$, $19.1{\pm}0.3$, and $19.9{\pm}0.6{\mu}M$, and compounds 6, 8, and 9 displayed significant cytotoxic activity against HL-60 with $IC_{50}$ values of $35.4{\pm}3.1$, $18.6{\pm}2.0$, and $42.9{\pm}3.0{\mu}M$, respectively.

Identification of Flavonoids from Extracts of Opuntia ficus-indica var. saboten and Content Determination of Marker Components Using HPLC-PDA (손바닥선인장 추출물의 플라보노이드 구조 규명 및 HPLC-PDA를 이용한 지표성분의 함량 분석)

  • Park, Seungbae;Kang, Dong Hyeon;Jin, Changbae;Kim, Hyoung Ja
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.2
    • /
    • pp.210-219
    • /
    • 2017
  • This study aimed to establish an optimal extraction process and high-performance liquid chromatography (HPLC)-photodiode array (PDA) analytical method for determination of marker compounds, dihydrokaempferol (DHK) and 3-O-methylquercetin (3-MeQ), as a part of materials standardization for the development of health functional foods from stems of Opuntia ficus-indica var. saboten (OFS). The quantitative determination method of marker compounds was optimized by HPLC analysis, and the correlation coefficient for the calibration curve showed very good linearity. The HPLC-PDA method was applied successfully to quantification of marker compounds in OFS after validation of the method in terms of linearity, accuracy, and precision. Ethanolic extracts from stems of O. ficus-indica var. saboten (OFSEs) were evaluated by reflux extraction at 70 and $80^{\circ}C$ with 50, 70, and 80% ethanol for 3, 4, 5, and 6 h. Among OFSEs, OFS70E at $80^{\circ}C$ showed the highest contents of DHK and 3-MeQ of $26.42{\pm}0.65$ and $3.88{\pm}0.29mg/OFS100g$, respectively. Furthermore, OFSEs were determined for their antioxidant activities by measuring 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging and lipid peroxidation (LPO) inhibitory activities in rat liver homogenate. OFS70E at $70^{\circ}C$ showed the most potent antioxidant activities with $IC_{50}$ values of $1.19{\pm}0.11$ and $0.89{\pm}0.09mg/mL$ in the DPPH radical scavenging and LPO inhibitory assays, respectively. To identify active components of OFS, various chromatographic separation of OFS70E led to isolation of 11 flavonoids: dihydrokaempferol, dihydroquercetin, 3-O-methylquercetin, quercetin, isorhamnetin 3-O-glucoside, isorhamnetin 3-O-galactoside, narcissin, kaempferol 7-O-glucoside, quercetin 3-O-galactoside, isorhamnetin, and kaempferol 3-O-rutinoside. The results suggest that standardization of DHK in OFSEs using HPLC-PDA analysis would be an acceptable method for the development of health functional foods.

Development of an analytical method for the quantification of oleanonic acid from mastic gum using HPLC/PDA

  • Hak-Dong Lee;Chang-Dae Lee;So Yeon Choi;Sanghyun Lee
    • Journal of Applied Biological Chemistry
    • /
    • v.66
    • /
    • pp.67-72
    • /
    • 2023
  • A simple and accurate method was developed for the quantitative analysis of oleanonic acid (OA) from mastic gum. The analysis was carried out using reverse-phase high-performance liquid chromatography combined with a photodiode array detector (HPLC/PDA). Our optimized method was validated by measuring various parameters, using an INNO C18 column fitted with a gradient elution system. The results revealed limits of detection and quantification of 0.34 and 1.042 ㎍/mL, respectively. The OA calibration curve exhibited excellent linearity over the concentration range of 0.0625 to 2.0 mg/mL, with r2 =0.9996. Accuracy tests revealed a high recovery rate of 99.44-103.66%, with precision values below 0.15%. These results suggest that the present analytical method can identify and quantify OA in mastic gum with high precision. The HPLC approach developed in this study might be applied to routine analyses and large-scale extraction procedures for OA content quantification.

Simultaneous Determination of Albiflorin, Cinnamaldehyde, Cinnamic Acid, Daidzin, Glycyrrhizin, Liquiritin, Paeoniflorin and Puerarin in Galgeun-tang by HPLC-PDA

  • Seo, Chang-Seob;Kim, Jung-Hoon;Shin, Hyeun-Kyoo
    • The Journal of Korean Medicine
    • /
    • v.31 no.6
    • /
    • pp.8-15
    • /
    • 2010
  • Objectives: We investigated to develop and validate HPLC-PDA methods for simultaneous determination of eight constituents in Galgeun-tang (GGT). Methods: Reverse-phase chromatography using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array (PDA) detection at 230 nm, 254 nm, and 280 nm, were used for quantification of the eight marker components of GGT. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. Results: Calibration curves were acquired with $r^2$ > 0.9999, and the relative standard deviation (RSD) values (%) for intra- and inter-day precision were less than 3.0%. The recovery rate of each component was in the range of 87.33-101.38%, with an RSD less than 7.0%. The contents of the eight components in GGT were 1.98-12.17 mg/g. Conclusions: The established method will be applied for the quantification of marker components in GGT.

Simultaneous Determination of Flavanone Glycosides in the Fruit of Citrus paradisi and C. grandis by HPLC-PDA

  • Piao, Xiang-Lan;Wu, Qian;Han, Saem;Kim, Hyun-Young;Lee, Sang-Hyun
    • Natural Product Sciences
    • /
    • v.17 no.4
    • /
    • pp.337-341
    • /
    • 2011
  • An HPLC (high-performance liquid chromatography)-PDA (photodiode array) detection method was established for the determination of naringin, hesperidin and neohesperidin in the fruit of Citrus paradisi and C. grandis. The flavonoids were separated in less than 20 min using an YMC RP 18 column with isocratic elution using acetonitrile and water (23 : 77, v/v) at a flow rate of 1 ml/min, and a PDA detector. The levels of naringin, hesperidin and neohesperidin were 1345.92, 950.62, and 2078.82 ${\mu}g/g$, respectively, in the peel, and 102.43, 59.13, and 86.68 ${\mu}g/g$, respectively, in the flesh of C. paradisi. In C. grandis, the levels of naringin, hesperidin and neohesperidin were 3530.56, 80.00, and 5.26 ${\mu}g/g$, respectively, in the peel, and 59.59, 7.43, and 38.41 ${\mu}g/g$, respectively, in the flesh. The total content was highest in the peel, reaching 0.44% and 0.36% in C. paradisi and C. grandis, respectively, while the flesh contained only 0.025% and 0.011%, respectively. Therefore, the peels of C. paradisi and C. grandis are necessary for the processing and utilization of flavonoids.

Simultaneous Analysis of Six Compounds in Yijin-tang by HPLC-PDA (HPLC-PDA을 이용한 이진탕 중 6종 성분의 동시분석)

  • Kim, Seong-Sil;Kim, Jung-Hoon;Shin, Hyeun-Kyoo;Seo, Chang-Seob
    • Herbal Formula Science
    • /
    • v.21 no.1
    • /
    • pp.71-79
    • /
    • 2013
  • Objectives : Yijin-tang has been used in the treatment of gastrointestinal diseases such as irritable bowel syndrome, gastritis, and gastric ulcer. In this study, a high-performance liquid chromatography (HPLC) method was established for simultaneous analysis of six compounds, liquiritin, glycyrrhizin, hesperidin, 6-gingerol, homogentisic acid, and 3,4-dihydroxybenzaldehyde in Yijin-tang, a traditional Korean herbal medicinal preparation. Methods : A Gemini C18 column was used for the separation of six constituents at $40^{\circ}C$. The mobile phase using gradient elution consist of two solvent systems, 1.0% acetic acid in water (A) and 1.0% acetic acid in acetonitrile (B). The flow-rate was 1.0 mL/min and injection volume was $10{\mu}g$. The detector was a photodiode array (PDA) detector set at 254 nm and 280 nm. Results : The calibration curves of six compounds showed good linearity in various concentration ranges ($R^2{\geq}0.9997$). The limits of detection (LOD) and limits of quantification (LOQ) were 0.028-$0.192{\mu}g/mL$ and 0.093-$0.540{\mu}g/mL$, respectively. The RSD (%) of the intra and inter day validations were 0.03-0.84% and 0.05 -1.00%, respectively. Recovery was 96.14-01.90% and RSD (%) was less than 1.5%. Conclusions : The established simultaneous analysis methods will help management to improve the quality of Yijin-tang.