• 제목/요약/키워드: HPGe

검색결과 151건 처리시간 0.019초

Study in Background Reduction for the Neutron Induced Prompt Gamma-ray Spectroscopy

  • Song, Byoung-Chul;Jee, Kwang-Yong;Park, Yong-Joon
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.433-433
    • /
    • 2004
  • Neutron induced prompt gamma-ray spectroscopy (NIPS) system measures the prompt gamma-ray, emitting by the interaction of a neutron with various materials. This system will be of great benefit to scientists worldwide, since it provides the non-destructive measurement of many elements in either solid or liquid wastes. A NIPS facility has been developed in Nuclear Chemistry Research Division, at Korea Atomic Energy Research Institute (KAERI) with the aim of analyzing the major component elements in both aqueous and solid samples.(omitted)

  • PDF

Effect of Coincidence Gamma-ray Spectroscopy to the Reduction of Background Spectrum

  • Kim, Taewook;Changsoo Yoou;Chongmook park;Kim, Byungtae
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(2)
    • /
    • pp.464-469
    • /
    • 1998
  • A coincidence gamma-ray spectroscopy method was applied to reduce the background radioactivity for measuring the activity of radioisotopes in a sample in the presence of environmental natural radioactivity. A HPGe detector was used for the coincident spectrum as a main detector and a NaI(Tl) scintillation detector for gating purposes as an associated detector. For coincidence spectroscopy the whole energy spectrum of associated detector was used instead of gate signals. The coincident events obtained from the gating spectrum was evaluated by a coincidence computer program in this study instead of timing circuit. In this work, the background of detection environment was reduced to factor 100 and peaks to be determined was reduced to factor 30 using the coincidence gamma-ray spectroscopy.

  • PDF

A New Approach on the Correction for Compton Escape Component in X-Ray Unfolding Algorithm

  • Kim, Soon-Young;Kim, Jong-Kyung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(2)
    • /
    • pp.925-930
    • /
    • 1995
  • A new approach on the correction for Compton escape component in X-ray unfolding algorithm was investigated to obtain more accurate X-ray source spectrum. The X-ray detector used in this study was a planar type HPGe detector(EG&G ORTEC, GLP-32340/13-P-LP) whose energy response has been blown and ISO narrow beam series were employed as source spectrum. At lower energy Part of measured X-ray spectrum including the correction for Compton escape component more accurate unfolded spectrum was obtained by letting down the starting energy level of the collection in existing spectrum correction procedure to consider multiple scattering effects. It is, from this study, concluded that accurate correction for Compton escape component is needed in X-ray unfolding procedure since Compton scattering becomes more important as incident X-ray energies increase.

  • PDF

Evaluation of 18F Radioactive Concentration in Exhaust at Cyclotron Facility at Chosun University

  • Jeong, Cheol-ki;Jang, Han;Lee, Goung-jin
    • 방사선산업학회지
    • /
    • 제10권1호
    • /
    • pp.37-41
    • /
    • 2016
  • The recent prevalence of PET examinations in Korea has led to an increase in the number of cyclotrons. The medical isotope $^{18}F$ produced in most cyclotron facilities currently operating in Korea is emitted into the environment during the production of [$^{18}F$]FDG, a cancerdiagnosis reagent. The amount of [$^{18}F$]FDG synthesized determines the radioactive concentration of $^{18}F$ in the exhaust. At some facilities, this amount temporarily exceeds the emission limit. In this study, we evaluated the $^{18}F$ radioactivity concentration in the exhaust from the cyclotron facility at Chosun University. The $^{18}F$ radioactivity concentration was measured using an air sampler and a HPGe semiconductor detector. The measurements showed that the radioactive concentration of $^{18}F$ in the exhaust at the cyclotron facility at Chosun University was the highest during [$^{18}F$]FDG synthesis but remained under the legal limit of $2,000Bq\;m^{-3}$.

Design, construction, and characterization of a Prompt Gamma Neutron Activation Analysis (PGNAA) system at Isfahan MNSR

  • M.H. Choopan Dastjerdi;J. Mokhtari;M. Toghyani
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4329-4334
    • /
    • 2023
  • In this research, a prompt gamma neutron activation analysis (PGNAA) system is designed and constructed based on the use of a low power research reactor. For this purpose, despite the fact that this reactor did not include beam tubes, a thermal neutron beam line is installed inside the reactor tank. The extraction of the beam line from inside the tank made it possible to provide the neutron flux from the order of 106 n.cm-2.s-1. Also, because the beam line is installed in a tangential position to the reactor core, its gamma level has been minimized. Also, a suitable radiation shield is considered for the detector to minimize the background radiation and prevent radiation damage to the detector. Calculations and measurements are done in order to characterize this system, as well as spectrometry of several samples. The results of evaluations and experiments show that this system is suitable for performing PGNAA.

안전조치 검증장비의 극한 온도환경 적용성 평가 (Evaluation of Usability in Extreme Temperature Environments of Safeguards Equipment)

  • 백희균;이진원;신중기
    • 방사선산업학회지
    • /
    • 제18권1호
    • /
    • pp.71-78
    • /
    • 2024
  • For most commercial radiation measurement equipment, manufacturers specify an operating temperature in the range of 0 to +40℃. However, in environments that exceed the quality assurance performance of the safeguards equipment, such as the winter environment in North Korea, the performance of the equipment deteriorates or normal use is impossible. In this study, safeguards equipment measurements were performed by creating an extreme temperature environment using a constant temperature and humidity test chamber. The safeguards equipment used in the evaluation was MIRION's Inspector-2000-based equipment, which evaluated the usability in extreme temperature environments using three types of detection units: NaI(Tl), CZT, and HPGe.

감마선 스펙트럼 비율을 이용한 매립 선원의 깊이 평가 방법론 개발 연구 (Study on Development of Embedded Source Depth Assessment Method Using Gamma Spectrum Ratio)

  • 김준하;정재학;홍상범;서범경;이병채
    • 방사성폐기물학회지
    • /
    • 제18권1호
    • /
    • pp.51-62
    • /
    • 2020
  • 본 연구는 감마스펙트럼 비율을 이용한 매립된 선원의 깊이 평가방법 개발 및 적용성 확인을 위해 진행되었다. 이를 위해 현장측정 HPGe 계측기 및 MCNP 전산모사를 이용하여 137Cs, 60Co, 152Eu 선원의 매질 내 깊이와 계측거리에 따른 Peak to Compton, Peak to Valley 비율(Q)의 변화를 평가하였다. 해당 결과를 이용해 계측거리 50 cm를 기준으로 PTV 및 PTC 비율(Q)과 매립 선원의 깊이 간의 상관 식을 도출하였다. 그리고 PTC 및 PTV 방법 이용 시 계측거리 변화에 따른 민감도를 평가한 결과, 50 cm 기준으로 계측거리가 20 cm로 감소할 경우 오차가 3 ~ 4 cm까지 증가하였다. 하지만 100 cm로 증가할 경우 계측거리에 의한 영향이 미미함을 확인하였다. 그리고 PTV 및 PTC 방법과 피크 영역의 계수율 변화를 통해 선원의 깊이를 평가하는 Two distance measurement 방법을 상호 비교하였다. 평가 결과 PTV 및 PTC 방법은 최대 1.87 cm의 오차, Two distance measurement 방법은 최대 2.69 cm의 오차를 나타내어 PTV, PTC 방법의 정확도가 비교적 높음을 확인하였다. 선원의 수평 방향 위치 변화 민감도 평가 결과 Two distance measurement 방법은 선원이 off-center 방향으로 30 cm 이동하였을 경우 최대 오차가 25.59 cm로 나타났다. 반면 PTV 및 PTC 방법은 최대 오차 8.04 cm로 현장 적용 시 높은 정확도를 나타낼 것으로 예상된다. 그리고 PTC 방법은 동일 시간 측정 시 다른 방법과 비교하여 낮은 표준편차를 나타내 신속한 평가가 가능할 것으로 기대된다.

RI 폐기물 내 방사성요오드 분석을 위한 분리 및 회수 (Separation and Recovery for the Analysis of Radioiodine in RI Wastes)

  • 강상훈;한선호;이흥래;지광용;이인구
    • 방사성폐기물학회지
    • /
    • 제5권4호
    • /
    • pp.267-272
    • /
    • 2007
  • RI 폐기물 내에 있는 낮은 방사능의 요오드의 함량을 결정하기 위해 산분해법과 BPGe 감마 선분광계를 이용하는 방법이 개발되었다. 분석에 앞서 모의시료인 제염지 내에 $^{131}I$이 일정량 첨가되었으며, 100 mL의 0.4 N $K_2Cr_2O_7$와 100 mL의 9 M $H_2SO_4$, 10 mL의 30% $H_3PO_3$, 1 mL의 $H_2O_2$를 넣고 산분해과정을 거치면서 증류된 용액을 응축하여 포집하였다. $CCl_4$의 용매추출에 의한 화학 분리과정을 거친 후 $AgNO_3$를 첨가해서 얻은 AgI 침전물을 여과하고 건조하여 측정하였다. 산분해 과정, 화학 분리과정, 여과 및 침전과정 등 세 단계로 나눠 회수율을 측정한 결과, 각각 94% 이상의 회수율을 나타냈으며, 본 연구의 측정조건에서 최소검출방사능은 0.6 Bq/g이었다.

  • PDF

핵활동 감시를 위한 대기 입자 측정시스템의 최소검출 방사능 농도 결정 (Minimum Detectable Radioactivity Concentration of Atmospheric Particulate Measurement System for Nuclear Test Monitoring)

  • 김종수;윤석철;신장수;곽은호;최종서
    • Journal of Radiation Protection and Research
    • /
    • 제22권2호
    • /
    • pp.111-117
    • /
    • 1997
  • 최근 포괄적 핵실험금지조약 (Comprehensive Test Ban Traety : CTBT)의 체결은 전세계적으로 핵활동 감시 네트워크를 구축하는 것이다. 핵실험금지 위원회의 전문가들은 대기 방사성핵종의 측정을 핵실험 감시에 필수적인 요소로 제안하였으며, 이에 따른 기술적 요구사항을 제시하였다. 본 연구는 이를 근거로 핵활동으로부터 생성된 핵분열생성물을 검출하기 위하여 고성능 공기채집장치(High Volume Air Sampler: HVAS)와 여과지 압축기 그리고 고순도 게르마늄 반도체검출기(HPGe)로 대기 입자 방사성핵종 측정시스템을 구성하였다. 조속한 시일 내에 탐지와 최적의 측정 조건으로 본 시스템을 운영하기 위하여 CTBT 감시 전략에서 주요 핵종들에 대한 최소검출 방사능 농도(Minimum Detectable Concentration : MDC)를 decay time, counting time 그리고 sampler volumetric flow rate 등을 고려하여 결정하였다. 그 결과 각각 $10{\pm}$2h, $20{\pm}$2h, $850{\pm}50m^3$//h 정도로 선정하였다. 감마선 스펙트럼 분석에서 $^{212}Pb$ 방사능 농도의 변화는 Compton continuum의 baseline에 영향을 미치게 되므로 이에 기인한 MDC 관계식을 도출하였다. 이들 결과는 CTBT 감시 전략에 실제적인 도구로 사용될 수 있을 것으로 사료된다.

  • PDF

지구통계학적 방법에 의한 영광원전주변 토층내 Cs-137 및 K-40 측정 결과의 해석 (Geostatistical Interpretation of Cs-137 and K-40 Result of the Lithosphere in the Vicinity of Youngkwang Nuclear Power Plant)

  • 김경웅;이재석;문승현;박철승;고일원;고은정;조병옥;정철영;전수열
    • 자원환경지질
    • /
    • 제35권6호
    • /
    • pp.545-552
    • /
    • 2002
  • 광주과학기술원 에너지환경연구센터에서는 2000년 한해 동안 원자력발전소 주변 환경방사선 조사계획에 의거하여 영광원자력발전소 부지외부 및 비교지점에서 토양, 하천토 및 해저토 등 환경방사능 시료에 대한 감마선 방출핵종 분석을 수행하였다. 분석결과 토양과 하천토 및 해저토에서 인공핵종인 Cs-137이 검출되었으나 지난 3년간(1997-99)의 측정치인 평상범위 이내의 값이었고, 원전과 관계없는 일반지역에서 검출되는 수준과도 동일하며, 반감기가 짧은 Cs-134는 전혀 검출되지 않은 것으로 보아 원전가동에 의한 영향이 아님을 알 수 있다. 환경시료 측정에 대한 품질관리를 위해 임의로 선정된 가마미인근에서 해저토 시료를 각각 5지점에서 중복시료로 채취하석 상대 검출효율이 각각 30%, 45%인 2대의 HPGe Gamma-ray Spectroscope로 동시에 분석하여 환경방사선 측정자료와 분석의 신뢰도를 향상시키기 위한 지구통계학적인 연구를 수행하였다. 이를 위해서 두 가지 요인을 설정하여 시료분석방법과 채취지점의 차이를 이원배치 분산분석을 수행하였다. Two-way ANOVA 결과 Cs-137 및 K-40의 경우 시료채취 지점의 차이에 의한 분산만이 유효하며, 시료채취 및 분석과정에서의 생기는 오차는 무시할 만하여 지금까지 수행되어진 시료채취 및 분석방법은 신뢰할 만하다고 할 수 있었다.