• 제목/요약/키워드: HPCS

검색결과 24건 처리시간 0.021초

Expression of Glypican-3 in Mouse Embryo Stem Cells and its Derived Hepatic Lineage Cells Treated with Diethylnitrosamine in vitro

  • Kim, Young Hee;Kang, Jin Seok
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권11호
    • /
    • pp.6341-6345
    • /
    • 2013
  • To clarify the role of stem cells in hepatocarcinogenesis, glypican-3 (GPC-3) and E-cadherin expression was investigated in embryonic cell lineages. Mouse embryonic stem cells (ESCs), hepatic progenitor cells (HPCs) and hepatocyte like cells (HCs), representing 0, 22 and 40 days of differentiation, respectively, were treated in vitro with diethylnitrosamine (DEN) at four doses (0, 1, 5 and 15 mM; G1, G2, G3 and G4, respectively) for 24 h and GPC-3 and E-cadherin expression was examined by relative quantitative real-time PCR and immunocytochemistry. GPC-3 mRNA expression was significantly different for G4 at day 0 (p<0.001) and for G4 at day 22 (p<0.01) compared with the control (G1). E-cadherin mRNA expression was significantly different for G3 and G4 at day 0 (p<0.05 and p<0.001, respectively), for G2 and G4 (p<0.05 and p<0.001, respectively) at day 22 and for G2 and G4 (p<0.01 and p<0.001, respectively) at day 40 compared with G1. Immunofluorescence staining for GPC-3 showed a membranous and/or granular expression in cytoplasm of ESCs and HPCs and granular and/or diffuse expression in cytoplasm of HCs, which were also stained by E-cadherin. DEN treatment increased GPC-3 expression in ESCs, HPCs and HCs, with increase of E-cadherin expression. Taken together, the expression of GPC-3 was altered by DEN treatment. However, its expression pattern was different at the stage of embryo stem cells and its derived hepatic lineage cells. This suggests that GPC-3 expression may be modulated in the progeny of stem cells during their differentiation toward hepatocytes, associated with E-cadherin expression.

(Hydroxypropyl)celluloses와 에스테르 및 에테르 유도체들의 합성과 Cholesteric 상의 특성 (Synthesis and Cholesteric Mesophase Properties of (Hydroxypropyl)celluloses, Their Ester and Ether Derivatives)

  • 정승용;정종현;마영대
    • 폴리머
    • /
    • 제25권2호
    • /
    • pp.279-292
    • /
    • 2001
  • 몰치환도 (MS)가 다른 두 종류의 (hydroxypropyl)celluloses (HPCs)와 이들로부터 3가지의 유도체, 즉 (acetoxypropyl)celluloses, (ethoxypropyl)celluloses와 (cyanoethoxypropyl) celluloses들을 합성함과 동시에 이들의 열 및 액정상의 특성을 검토하였다. 모든 시료들은 상온에서 cholesteric 상의 반사색깔들을 나타내며 온도상승에 의해 광학 pitch(λ$_{ms}$ )가 증가하는 우측방향의 나선구조를 형성하였다. 그러나, 검토한 유도체들의 액정상에서 등방상액체로의 전이온도($T_{i}$)와 유리전이온도, 동일한 온도에서 액정상이 나타내는 λ$_{m}$ 의 크기 그리고 λ$_{m}$ 의 온도의존성은 MS와 HPC에 도입된 측쇄의 길이 및 화학구조에 크게 의존하였다. 이들의 결과를 치환기의 극성과 유연성의 차이 그리고 주쇄들간의 거리 등과의 관련하에서 검토하였다. 모든 유도체들에 있어서, λ$_{m}$ 값들은 액정상의 $T_{i}$보다 높은 온도에서 무한대로 접근하므로 온도에 의한 나선방향의 역전은 검출되지 않았다.

  • PDF

영남지역 지하수에서 대장균군의 분포 및 분리한 세균의 특성 (Distribution and Characteristics of Coliform Bacteria in Groundwater of Yeungnam Province)

  • 이인환;김수경;최윤희;김종설
    • 미생물학회지
    • /
    • 제42권2호
    • /
    • pp.95-102
    • /
    • 2006
  • 생활용수로 사용하는 영남지역 지하수의 세균학적 수질을 평가하기 위해, 여름 123개 지점, 겨울 117개 지점에서 지하수 시료를 채수하였다. 일반세균 수의 중앙간은 여름 30 CFU/ml, 겨울 40 CFU/ml이었고, 25% 이상의 조사지점에서 일반세균 수는 먹는물 수질기준 100 CFU/ml을 초과하였다. 전체 조사지점 중 여름 46%, 겨울 30%의 지점에서는 대장균군이 검출되었으며, 이들 지점에서 대장균군 수의 중앙간은 여름 20 CFU/ml, 겨울 4 CFU/ml로 여름이 겨울보다 높았다. 분리한 대장균군 세균은 Citrobacter속, Enterobacter속, Eschericitia속, Klebsiella속, Pantoea속, Rahnella속, 그리고 Serratia속으로 동정되었으며, Enterobacter속이 48%를 차지하여 가장 많았다. 종별로는 E. cloacae, E. amnigenus, K. pneumoniae등이 빈도가 높게 분리되었으며, 반면 E. coli는 1개 조사지점에서만 분리되었다. 대장균군 수는 일반세균 수와 양의 상관관계를 보였으며, 일반세균 수는 수온과도 양의 상관관계가 있었다. 본 연구의 결과는 지하수에서 대장균군의 오염에 대한 보다 자세한 정보를 제공해 주며, 영남지역의 지하수에서 병원성 미생물의 오염 가능성이 여전히 높음을 시사한다.

Effect of Distribution System Materials and Water Quality on Heterotrophic Plate Counts and Biofilm Proliferation

  • 장영철;정권
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권6호
    • /
    • pp.1114-1119
    • /
    • 2004
  • The biofilms on pipe walls in water distribution systems are of interest since they can lead to chlorine demand, coliform growth, pipe corrosion, and water taste and odor problems. As such, the study described in this paper is part of an AWWARF and Tampa Bay Water tailored collaboration project to determine the effect of blending different source waters on the water quality in various distribution systems. The project was based on 18 independent pilot distribution systems (PDS), each being fed by a different water blend (7 finished waters blended in different proportions). The source waters compared were groundwater, surface water, and brackish water, which were treated in a variety of pilot distribution systems, including reverse osmosis (RO) (desalination), both membrane and chemical softening, and ozonation-biological activated carbon (BAC), resulting in a total of 7 different finished waters. The observations from this study consistently demonstrated that unlined ductile iron was more heavily colonized by a biomass than galvanized steel, lined ductile iron, and PVC (in that order) and that the fixed biomass accumulation was more influenced by the nature of the supporting material than by the water quality (including the secondary residual levels). However, although the bulk liquid water cultivable bacterial counts (i.e. heterotrophic plate counts or HPCs) did not increase with a greater biofilm accumulation, the results also suggested that high HPCs corresponded to a low disinfectant residual more than a high biofilm inventory. Furthermore, temperature was found to affect the biofilms, plus the AOC was important when the residual was between 0.6 and 2.0 mg $Cl_2/l$. An additional aspect of the current study was that the potential of the exoproteolytic activity (PEPA) technique was used along with a traditional so-called destructive technique in which the biofilm was scrapped off the coupon surface, resuspended, and cultivated on an R2A agar. Both techniques indicated similar trends and relative comparisons among the PDSs, yet the culturable biofilm values for the traditional method were several orders of magnitude lower than the PEPA values.

배수관망에서 수처리에 의한 AOC, BDOC및 세균성장의 특성 (Characterizations of Assimilable Organic Carbon, Biodegradable Dissolved Organic Carbon, and Bacterial Regrowth in Distribution Systems by Water Treatment)

  • Chang, Young-Cheol;Kweon Jung;Yoo, Young-Sik;Kang, Mi-Hye;Andrew A. Randall
    • 한국환경보건학회지
    • /
    • 제28권5호
    • /
    • pp.42-52
    • /
    • 2002
  • 배수관망에서의 박테리아 재 증식은 큰 현안문제로 대두되고 있으며 이를 억제하기 위한 염소소독 또한 발암성의 부산물인 THMs(trihalomethanes)등을 생성시킬 우려 때문에 미국에서는 오존살균처리 또는 나노여과 (nanofiltration) 법으로 대체해 오고 있다. 그러나 종래의 많은 bench scale 실험결과를 통해 이러한 처리 이후에 잔존하는 미량의 유기물(assimilable organic carbon)이 박테리아 재 증식에 계속하여 영향을 주고 있다는 결과가 AOC(assimilable organic carbon)와 박테리아 재증식의 상관관계를 통하여 밝혀지고 있다. 그러나 현재까지 이러한 연구결과를 full-scale규모의 현장시설에서 직접 검토한 예는 없다. 따라서 본 실험은 미국플로리다주에 위치한 두 지역의 full-scale배수관망 시설을 선정하여 실시하였다. 첫 번째 시설은 오존 살균처리를 그리고 다른 한곳은 나노여과와 석회 연수법 (lime softening)을 병행한 처리법을 사용하고 있다. 박테리아 증식은 R2A 배지를 사용하는 HPC(heterotrophic plate counts)법으로 평가했으며 오존이 공급된 배수관망에서의 HPC 는 각 셈플링 지점의 AOC값을 이용한 지수모델과 높은 상관관계가 있음이 판명되었다($R^2$=0.97). 또한 오존처리는 100%이상의 AOC 농도증가를 나타냈다. 나노여과법과 석회연수법을 병행하고 있는 시설에서도 AOC에 근거한 지수모델과 상관관계를 나타냈다($R^2$=0.75). 그러나 BDOC(biodegradable dissolved organic carbon)는 박테리아 증식에 있어 매우 낮은 상관관계 값을 표시했다($R^2$=0.11). 결과적으로 종래의 많은 bench scale실험결과와 같이 AOC는 배수관망에서의 박테리아 증식과 크게 상관관계를 갖고 있는 것으로 밝혀졌다.

폴리카보실란계 바인더를 이용한 다공성 SiC 세라믹스의 제조 (Preparation of Porous SiC Ceramics Using Polycarbosilane Derivatives as Binding Agents)

  • 박지혜;김영희;정미원
    • 한국세라믹학회지
    • /
    • 제49권5호
    • /
    • pp.412-416
    • /
    • 2012
  • Porous SiC ceramics were prepared by using recycled SiC sludge, which is an industrial waste generated from solar cell industry. Polycarbosilane derivatives, such as polycarbosilane (PCS), polyphenylcarbosilane (PPCS) and hydridopolycarbosilane (HPCS) were used as binding agents for the fabrication of porous SiC ceramics at $1800^{\circ}C$ under Ar atmosphere. The effects of the various binding agents having different C/Si ratios were discussed on the sintering and porosity of the SiC ceramics. The prepared porous SiC ceramics were characterized by X-ray Diffraction (XRD) and Field-Emission Scanning Electron Microscope (FE-SEM). Thermal conductivity and porosity of SiC ceramics were measured at room temperature, and they were 56.7W/mK and 29.8%, respectively.

정전류·정전압 기능의 1kW급 하이브리드 PCS 설계 (Design of 1kW Hybrid CC/CV PCS)

  • 이재민
    • 디지털콘텐츠학회 논문지
    • /
    • 제14권4호
    • /
    • pp.529-536
    • /
    • 2013
  • 태양광 풍력 하이브리드(Hybrid) 발전 시스템에서는 발전의 주 인자인 태양의 일조량과 바람의 세기 등이 환경적 요인으로 적절하지 못할 경우 충방전 성능의 한계를 가지고 있는 에너지 저장장치인 배터리를 충전하는데 어려움이 발생한다. PCS(power conditioning system)는 태양광 풍력 발전 시스템 운용에 필수적인데 기존의 대부분의 PCS는 중대형 중심이어서 소형 발전에 적합하지 않아 효율이 높고 안정적인 동작을 하는 소형 발전용 PCS 개발이 절실히 요구된다. 본 논문에서는 이러한 문제들을 해결하면서 상용(한전)전력과의 계통연계 및 독립 운영이 가능하고 배터리의 장수명화와 안정화가 가능한 1kW급 하이브리드 CC/CV(constant current/constant voltage)기능을 갖는 PCS를 설계하고 시제품으로 구현하여 그 성능을 검증한다.

Effect of damage on permeability and hygro-thermal behaviour of HPCs at elevated temperatures: Part 1. Experimental results

  • Gawin, D.;Alonso, C.;Andrade, C.;Majorana, C.E.;Pesavento, F.
    • Computers and Concrete
    • /
    • 제2권3호
    • /
    • pp.189-202
    • /
    • 2005
  • This paper presents an analysis of some experimental results concerning micro-structural tests, permeability measurements and strain-stress tests of four types of High-Performance Concrete, exposed to elevated temperatures (up to $700^{\circ}C$). These experimental results, obtained within the "HITECO" research programme are discussed and interpreted in the context of a recently developed mathematical model of hygro-thermal behaviour and degradation of concrete at high temperature, which is briefly presented in the Part 2 paper (Gawin, et al. 2005). Correlations between concrete permeability and porosity micro-structure, as well as between damage and cracks' volume, are found. An approximate decomposition of the thermally induced material damage into two parts, a chemical one related to cement dehydration process, and a thermal one due to micro-cracks' development caused by thermal strains at micro- and meso-scale, is performed. Constitutive relationships describing influence of temperature and material damage upon its intrinsic permeability at high temperature for 4 types of HPC are deduced. In the Part II of this paper (Gawin, et al. 2005) effect of two different damage-permeability coupling formulations on the results of computer simulations concerning hygro-thermo-mechanical performance of concrete wall during standard fire, is numerically analysed.