• Title/Summary/Keyword: HP holder

Search Result 9, Processing Time 0.033 seconds

Numerical Analysis of the Flow Characteristics of High-Pressure Injection Nozzle for Machine Tools (공작기계용 HP Holder 분사노즐 유동특성에 관한 수치해석)

  • Yi, Chung-Seob;Yun, Ji-Hun;Jeong, In-Guk;Song, Chul-Ki;Suh, Jeong-Se
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.10
    • /
    • pp.1061-1066
    • /
    • 2011
  • In this study, the flow characteristics of an injection nozzle installed in a high-pressure holder for improving productivity were determined. The inlet velocity, nozzle inflow angle, and nozzle outlet diameter were selected as design factors having an influence on the flow characteristics, and numerical analysis was conducted for these factors. As the inlet velocity is high and the nozzle outlet diameter is small, the pressure and velocity of the injected flow are high. In the case of the nozzle inflow angle, the variation of flow characteristics according to angle was slight, but the highest pressure and velocity were found at $15^{\circ}$. In addition, the possibility of chip elimination by the injected flow was analyzed on the basis of the numerical results.

Magnetic Sector SIMS의 Sample Holder 위치에 따르는 RSF (Relative Sensitivity Factor) 변화 검증

  • 홍성윤;이종필;홍태은;윤명노;민경열;이순영
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.192-192
    • /
    • 1999
  • SIMS(Secondary Ion Mass Spectrometry)는 다른 표면 분석장비와 비교하여^g , pp m,^g , pp b 단위의 미량분석이 가능한 장비로서, 특히 depth Profiling을 위한 dynamic SIMS는 Mass Spectrometer의 종류에 따라 Quadrupole SIMS (Q-SIMS)와, Magnetic Sector SIMS (M-SIMS)로 분류된다. 한편, Q-SIMS와 달리 M-SIMS의 경우, Transmission을 높여 주기 위해 Sample Holder에 수 keV의 bias를 걸어 주는데, 이로 인하여 분석 원소에 대한 Sensitivity가 향상되어 지는 반면, RSF의 변화와 같은 분석상의 Artifact가 발생하게 된다. 일반적으로 Q-SIMS의 경우에는 RSF의 RSD(Relative Standard Deviation)가 1%이내에서 보고되고 있지만 M-SIMS에 있어서는 이러한 Deviation이 M-SIMS보다 크게 나타난다. 이 차이는 주로 Sample Holder와 Immersion Lens 사이에 형성되는 Magnetic Field의 왜곡과 Spectrometer의 문제로부터 발생한다. 본 논문에서는 Sample Holder의 종류 및 holder so window 위치에 따라 RSF의 차이를 측정하고 그 data를 RS/1 통계 Package를 이용하여 계량적으로 검증하였으며, 그 차이의 원인과 대책을 제시하고자 한다. 실험에 사용된 Sample은 Si(100) p-type Wafer에 Boron을 이온 주입하여 제작하였다. 이온 주입 장비는 Varian E-500HP이며, 5.0E13 ions/cm2의 dose양을 80keV의 Energy로 각각 7도와 22도의 Tilt와 Twist Angle로 이온 주입을 하였다. SIMS분석에 사용된 Sample Holder는 각각 3 Hole, 9 Hole Type HOlder이며, 분석은 Cameca IMS-6f를 사용하여 B에 대한 Matrix Peak으로 28Si++를 얻었다. 실험 결과 3 Hole Type Sample Holder의 경우 RSF의 RSD는 5.84%, 9Hle Type Sample Holder의 경우는 14.3%로 나타났으나 분석 Window의 위치에 따르는 Grouping을 실시한 결과, 3 Hole Type Sample Holder의 경우 1.2%, 9Hole Type Sample Holder의 경우 9.8%로 RSF의 변화가 감소하였다. 이러한 Deviation은 Sample Holder를 Mount시킬 때 세 개의 Screw를 이용하여 Immersion Lens와의 평형을 잡아주기 때문에 발생하며, 이 Munting을 정확히 해줌으로써 RSF의 변화를 줄일 수 있으나, 실제로 완벽한 Mounting이 불가능하기 때문에 RSF를 일정하게 하기 위해서는 Sample Holder so Window의 취치를 일정하게 설정한 후 분석을 실시해야 한다고 판단된다.

  • PDF

Breast Milk-Transmitted Cytomegalovirus Infection in Preterm Infants

  • Gang, Mi Hyeon;Chang, Mea-young
    • Neonatal Medicine
    • /
    • v.25 no.2
    • /
    • pp.58-65
    • /
    • 2018
  • Purpose: The purpose of this study is to describe the rate of cytomegalovirus (CMV) virolactia, and the prevalence of breast milk (BM)-transmitted postnatal CMV infection among premature infants after freeze-thawing (FT) and Holder pasteurization (HP) of breast milk. Methods: This is a single-center, retrospective study of 312 infants born at less than 32 weeks of gestation, or with a birth weight less than 1,500 g from January 2013 to June 2017. All infants were screened for CMV-specific immunoglobulin (Ig) G and IgM at birth. Initial CMV specific polymerase chain reaction (PCR) and CMV culture were performed on mothers' BM and babies' urine within the first 21 days of life. FT and HP of BM was used to prevent the transmission of CMV. For the surveillance of postnatal CMV infection, CMV culture and CMV specific PCR of urine from babies were repeated one to two months after the initial screening. Screening for viremia and viruria was performed if postnatal CMV infection was suspected. Results: Among 178 BM samples obtained from mothers of CMV-IgG-seropositive infants, 80 (44.9%) were CMV PCR positive. CMV deoxyribonucleic acid (DNA) was detected in five of the 22 BM samples (22.7%) obtained from the mothers of CMV-IgG seronegative infants. When CMV DNA load in BM was measured before and after HP, various results were shown. Sixty-three infants out of 232 (27.2%) were evaluated for postnatal CMV infection and four infants out of 63 (6.3%) were infected. Conclusion: Interventions to prevent BM-transmitted CMV infection can reduce the chance of postnatal CMV infection, but not completely eliminate it.

An Experimental Study on Cutting Process using High Pressure Injection Holder (고압 분사 홀더를 이용한 절삭가공에 대한 실험적 연구)

  • Chung, Sang-Wan;Jeong, In-Guk;Yi, Chung-Seob;Song, Chul-Ki;Suh, Jeong-Se
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.790-796
    • /
    • 2012
  • Chip curling occurred during cutting process for difficult-to-cut material detracts product qualities and productivity. Among of method preventing the phenomenon, high pressure injecting cutting oil is an alterative. In this study, the optimal nozzle was designed by CFD method and it was conducted to analyse on the effect of high pressure injection on chip shape generated during cutting process and wear of insert by experimental method. As the result, it could be confirmed that high pressure injection is favorable for preventing chip curling and insert from wearing.

A Study on Design of High Pressure Injection Nozzle for Avoiding Chip Curling (칩 말림 방지를 위한 고압 분사 노즐 설계에 관한 연구)

  • Yi, Chung-Seob;Yun, Ji-Hun;Jeong, In-Guk;Song, Chul-Ki;Suh, Jeong-Se
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.6
    • /
    • pp.793-798
    • /
    • 2011
  • In this study, it was grasped to the flow characteristics of cutting fluid injected by nozzle installed in high pressure holder for avoiding chip curling occurred during machining process. And for avoiding chip curling, the possibility of elimination under various chip conditions was checked. Consequently, the highest discharging pressure and velocity was shown in 150 of nozzle inflow angle. Also as nozzle outlet diameter is small, the pressure and velocity of injected flow are high. Moreover, It could be confirmed that width and thickness of chip have no direct effect on chip elimination and it is achieved by torque generated by injected cutting fluid.

Measurement of Grain Moisture Content using RF Impedance (I) - Electrical Properties of Grain - (고주파 임피던스를 이용한 곡류의 함수율 측정에 관한 연구 (I) - 곡류의 전기적 특성 구명 -)

  • 김기복;노상하
    • Journal of Biosystems Engineering
    • /
    • v.24 no.2
    • /
    • pp.123-134
    • /
    • 1999
  • The electrical properties such as dielectric constant, dielectric loss factor and AC conductivity of grain were presented to measure the moisture content of grain using RF impedance. At frequency ranging from 1 to 10MHz and room temperature, $20^{\circ}C$, vector network analyzer(HP4195) and coaxial type sample holder were used to analyze the electrical properties of paddy(11∼24%w.b.), brown rice(11∼18%w.b.), barley(11∼21%w.b.) and wheat(11∼23%w.b.) depending on the moisture content, frequency and bulk density. The dielectric constant and AC conductivity of grain samples increased with moisture content and bulk density. The dielectric constants decreased with frequency and could be expressed as function of the moisture density(decimal moisture $content{\times}bulk$ density).

  • PDF

Complex Permittivity Extraction of Blood Glucose at Microwave Frequency

  • Jeong, You-Chul;Lee, Hee-seok;Kim, Joung-ho
    • Journal of electromagnetic engineering and science
    • /
    • v.1 no.2
    • /
    • pp.139-145
    • /
    • 2001
  • In this paper, a coaxial sample holder is proposed with its de-embedding and parameter extraction procedure. The S-parameters were measured up to 1 GHz using network analyzer, HP8753D, and N-type connector together with the de-embedding of N-type connector. The proposed de-embedding procedure is performed to extract electrical parameters of blood glucose, which gives the permittivity of blood glucose. We also analyzed the error of extracted parameters, which are caused by instrument error and geometrical error. Using these error analyses, we reduced the error factors of extracted parameters. We extracted electrical parameters of glucose samples through these all extraction procedure and confirmed the possibility of glucose diagnosis system based on microwave system.

  • PDF

MOISTURE CONTENT MEASUREMENT OF POWDERED FOOD USING RF IMPEDANCE SPECTROSCOPIC METHOD

  • Kim, K. B.;Lee, J. W.;S. H. Noh;Lee, S. S.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.188-195
    • /
    • 2000
  • This study was conducted to measure the moisture content of powdered food using RF impedance spectroscopic method. In frequency range of 1.0 to 30㎒, the impedance such as reactance and resistance of parallel plate type sample holder filled with wheat flour and red-pepper powder of which moisture content range were 5.93∼-17.07%w.b. and 10.87 ∼ 27.36%w.b., respectively, was characterized using by Q-meter (HP4342). The reactance was a better parameter than the resistance in estimating the moisture density defined as product of moisture content and bulk density which was used to eliminate the effect of bulk density on RF spectral data in this study. Multivariate data analyses such as principal component regression, partial least square regression and multiple linear regression were performed to develop one calibration model having moisture density and reactance spectral data as parameters for determination of moisture content of both wheat flour and red-pepper powder. The best regression model was one by the multiple linear regression model. Its performance for unknown data of powdered food was showed that the bias, standard error of prediction and determination coefficient are 0.179% moisture content, 1.679% moisture content and 0.8849, respectively.

  • PDF

Characterizing a Full Spectrum of Physico-Chemical Properties of Ginsenosides Rb1 and Rg1 to Be Proposed as Standard Reference Materials

  • Kim, Il-Woung;Hong, Hee-Do;Choi, Sang-Yoon;Hwang, Da-Hye;Her, Youl;Kim, Si-Kwan
    • Journal of Ginseng Research
    • /
    • v.35 no.4
    • /
    • pp.487-496
    • /
    • 2011
  • Good manufacturing practice (GMP)-based quality control is an integral component of the common technical document, a formal documentation process for applying a marketing authorization holder to those countries where ginseng is classified as a medicine. In addition, authentication of the physico-chemical properties of ginsenoside reference materials, and qualitative and quantitative batch analytical data based on validated analytical procedures are prerequisites for certifying GMP. Therefore, the aim of this study was to propose an authentication process for isolated ginsenosides $Rb_1$ and $Rg_1$ as reference materials (RM) and for these compounds to be designated as RMs for ginseng preparations throughout the world. Ginsenoside $Rb_1$ and $Rg_1$ were isolated by Diaion HP-20 adsorption chromatography, silica gel flash chromatography, recrystallization, and preparative HPLC. HPLC fractions corresponding to those two ginsenosides were recrystallized in appropriate solvents for the analysis of physico-chemical properties. Documentation of the isolated ginsenosides was made according to the method proposed by Gaedcke and Steinhoff. The ginsenosides were subjected to analyses of their general characteristics, identification, purity, content quantitation, and mass balance tests. The isolated ginsenosides were proven to be a single compound when analyzed by three different HPLC systems. Also, the water content was found to be 0.940% for $Rb_1$ and 0.485% for $Rg_1$, meaning that the net mass balance for ginsenoside $Rb_1$ and $Rg_1$ were 99.060% and 99.515%, respectively. From these results, we could assess and propose a full spectrum of physicochemical properties for the ginsenosides $Rb_1$ and $Rg_1$ as standard reference materials for GMP-based quality control.