• Title/Summary/Keyword: HOSE

Search Result 308, Processing Time 0.028 seconds

Study of Mechanical Characteristics of Electric Cupping Apparatus in Korea for Suggestion of its Assessment Guideline (국내 평가 가이드 라인 제시를 위한 전동식 부항기의 특성 조사에 관한 연구)

  • Yi, Seung-Ho;Kim, Eun-Jung;Shin, Kyung-Hoon;Nam, Dong-Woo;Kang, Jung-Won;Lee, Seung-Deok;Lee, Hye-Jung;Lee, Jae-Dong;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Objectives : The mechanical properties of Korean electric cupping systems are studied via experimental measurements. The study aimed at establishing the fundamentals of industrialization and systemization of oriental medicine device industry, as well as improving the quality of life for many Koreans. Methods : We reviewed the studies on traditional cupping as well as modern one to fine necessary factors for electric cupping systems. To characterize the mechanical properties of Korean electric cupping systems, we measured the pressure characteristics of commercially available electric cupping system by using an automatic pressure acquisition system and a standard cup. The pumping capability was checked at 40 seconds, and the stability of the suction cup was checked at 600 seconds. We also acquired the noise level of each system in clinical setting. To check the portability of each system, we also measured its physical dimensions. We scrutinized system manuals provided by the system manufacturers. Results : It took less than 5 second to reach the pressure if the connection between the air hose and the vacuum valve of the cupping system was secure. Pressure diminished to no more than 10% for 600s for all systems. Noise levels were 55~70 dB. Increase in pressure was too fast to control for a designated vacuum level except for one product. Conclusions : The Pumping ability of the systems is impressive and reliable. Pressure retention ability of each cup is quite reliable and reproducible. Therefore, their mechanical performances were worthy of recommendation. Some of them had noise level higher than 60 dB and they were bothersome. It was also suggested that the control for low to middle pressure needed to be accomplished by the cupping system.

A Study on the Wearing Condition and Satisfaction of Pesticide Protective Clothing (농약방제복 착용실태 및 만족도에 관한 연구)

  • Oh, Young-Soon;Lee, Kyung-Suk;Chae, Hye-Seon;Kim, Kyung-Ran;Kim, Sung-Woo
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.16 no.4
    • /
    • pp.217-228
    • /
    • 2014
  • The purpose of this study is to grasp inconveniences and improvements by examining wearing condition and satisfaction of protective clothing targeting 114 Korean farmers and to suggest basic data for enhancement of pattern and wearing satisfaction of protective clothing by understanding problems of pesticide-proof clothing through comparative analysis on the size of its commercial products. Most of male subjects were in charge of spraying pesticide, whereas female were most likely to play an assistant role to hold the hose of pesticide applicator. Both of female and male subjects were very aware of the harmful effect of pesticide on human body and tried to take off the clothes immediately after spraying it to reduce possible damage caused by pesticide. As a result of examining wearing condition, the farmers avoided wearing protective clothing because that it feels hot, stuffy, and uncomfortable to move. This hesitant response of wearing the clothing was not shown significantly in case of female subjects who play an assistant role for spraying. Although the farmers wore protective equipments such as mask or gloves in a proper way as compared to protective clothing, they seemed to choose alternative way rather than best way to block pesticide completely. The satisfaction regarding to the fitting of protective clothing which the subjects showed low in all items of upper-lower clothes except waistline. It is necessary to improve the functionality such as relief from heat stress and convenience for movement rather than design or economic in protective clothing development. As a result of comparing the size of five kinds of commercial protective clothing, the farmers got confused to choose the product since designation method of size across companies showed a significant difference in an identical clothing size. In addition, the sizing system developed on a basis of a well-built man has become a hindering factor in wearing satisfaction of female farmers.

  • PDF

Study of Failure Examples for Emission Gas Control System in Gasoline Engine (가솔린 엔진 배출가스 제어장치에 대한 고장사례 고찰)

  • Lee, Il Kwon;Lee, Jong Ho;Lee, Young Suk;Youm, Kwang Wook;han, Jae Oh;Lim, Ha young
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.37-42
    • /
    • 2016
  • The purpose of this paper is to study for the emission gas control of passenger car. The first example, the PCSV never open when operating condition, but it opened by causing malfunction because of trouble. As a result, the purge gas entered into surge tank, a mount of fuel was displayed with excessive supply on tester. Therefore, it certified the bad-condition of the engine when idling by decreasing of fuel injection quantity from engine ECU. The second example, the hose activating a EGR valve didn't supply the vacuum pressure because of assembling the other part. Thus, it knew the bad-condition of engine that the EGR valve would not work normally by leaking with the other port. The third example, as the rear oxygen sensor of two sensor were fault-installing by changing the sensor of other a car it could not detect of oxygen quantity. Finally, it found the phenomenon of abruptly decreasing vehicle speed when braking a car. Therefore, the system including with emission control has to drastically manage by maximizing condition to role decreasing the emission gas.

Effects of Concentrated Pig Slurry Separated from Membrane Filter and Several Environment-Friendly Agro-Materials Mixtures on the Growth and Yield of Lettuce (Lactuca sativa L.) in Hydroponics (막분리 돈분농축액비와 몇가지 친환경농자재의 혼합액이 수경재배에서 상추의 생육과 수량에 미치는 영향)

  • Ryoo, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.16 no.1
    • /
    • pp.51-60
    • /
    • 2010
  • This experiment was conducted to investigate the effects of concentrated pig slurry separated from membrane filter and by environment-friendly agro-materials mixtures on growth of lettuce in hydroponics. The swine waste treatment system having a ultra filtration and a reverse osmosis process was designed in this study. Filtration of pig slurry was necessary to prevent the hose clogging in hydroponics. Primary separation using ultra filter was followed by concentration by RO (Reverse Osmosis). The concentrated pig slurry (CS) was mixed by five different environment-friendly agro-materials mixtures. The chemical nutrient solution was the solution of National Horticulture Research Station for the growth of lettuce. The concentration of nutrient solution in hydroponics was adjusted a range of 1.5 mS/cm in EC. The concentrated pig slurry was low in phosphorus(P), suspended solid and heavy matal, but rich in potassium (K). The concentrated slurry was lowest in the growth characteristics of leaf lettuce. And also SPAD value in leaf was reduced in plot treated with concentrated slurry. But the growth of lettuce in the mixtures plot (CS+BM+AA, CS+BM+AA+SW) in hydroponics was significantly high compared to concentrated slurry. The fresh yield of lettuce was 78, 84% that of nutrient solution as 131.9, 142.2g in plot of CS+BM+AA and CS+BM+AA+SW, respectively. Our studies have shown that it is possible to produce organic culture using concentrated slurry and environment-friendly agro-materials mixture, although growth is slower than when using a conventional inorganic hydroponic solution.

Changes in The Amount of Air Respirator Consumed by Field Fire-fighting Activities (현장 소방활동에 따른 공기호흡기 소모량의 변화)

  • Jeon, Jai-In;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.4
    • /
    • pp.93-98
    • /
    • 2019
  • The purpose of this study was to identify and analyze the rate of change of air respirator consumption based on field fire fighting activities, The results of the experiment are as follows. The mean air consumption of the Five subjects was $15.56{\ell}/min$ when standing still, $32.43{\ell}/min$ when walking with normal pace, $43.07{\ell}/min$ when the fire hoses was expanded and arranged, $55.28{\ell}/min$ when climbing stairs, The situation of running up the stairs and hitting the hammer continuously increases to $127.14{\ell}/min$, which means that the consumption of air increases according to the energy consumption. Despite being the oldest, Experimental subject A was $13.23{\ell}/min$ when standing still, $29.33{\ell}/min$ when walking normally, and $41.08{\ell}/min$ when the fire hose was deployed and arranged. This is a result of familiarity with deep and slow breathing methods. The average respiratory use rate of subjects D was $63.58{\ell}/min$. The reason for this is that obesity seems to increase the air consumption, and it is considered that the physical strength is exhausted by the action of the hammer, which has a greater influence on the increase of air consumption. The subject E had significantly lower air respiratory use rate of $49.90{\ell}/min$. The reason for this is that the age of E is the youngest among the subjects, and it is presumed that it possesses strong physical strength.

Effect of Magnesium Oxide on Physical and Chemical Properties of FKM Elastomer (FKM Elastomer의 물리적 및 화학적 성질에 미치는 산화마그네슘의 영향)

  • Lee, Chang-Seop;Choi, Gi-Tae;Choi, Han-Hwal
    • Elastomers and Composites
    • /
    • v.38 no.1
    • /
    • pp.57-64
    • /
    • 2003
  • Metal oxide(MgO) was added to FKM rubber in order to develop automotive fuel hose which ran show elastic characteristics under extreme condition. Cure characteristics, physical properties, thermal resistance and fuel resistance of FKM compounded rubber with MgO were investigated. MgO was mixed to FKM rubber materials within the range of $0{\sim}20phr$. From the test results of rheological properties and Mooney viscosity, the $t_{s2}$, $T_{c90}$ values increased as the MgO contents increased in FKM rubber compounding. Hardness and 100% modulus of FKM compounded rubber slightly increased, but tensile strength and elongations at break slightly decreased. From the test results of thermal resistance of rubber specimens at 130, 150, and $170^{\circ}C$ for 70 hrs, the changing rate of physical properties was found to be relatively small. Fuel resistance tests were carried out for fuel A, B, C and D at $40^{\circ}C$ for 70hrs, and the results showed that the changing rate in physical properties was found to increase from Fuel A to D, Furthermore thermal properties of FKM compounded rubber containing MgO were also investigated by using TGA/DSC. The optimum mixing ratio of additive to FKM rubber to get the maximum effect on thermal resistance and fuel resistance, within the range of desirable specification for rubber material, was determined to be 6 phr for MgO.

Discharging Performance in Length of Hard Labyrinth and Pressure of Cylinder Type Drip Irrigation Hose (원통형 점적기의 압력과 경질미로의 길이에 따른 토출 특성)

  • Kim, Jin Hyun;Woo, Man Ho;Kim, Dong Eok
    • Journal of agriculture & life science
    • /
    • v.52 no.6
    • /
    • pp.103-109
    • /
    • 2018
  • The performance of drip irrigation devices depends on flow uniformity related to the function of pressure compensation. The flow uniformity can be secured when the internal fluid pressures at the positions of the flow holes are maintained uniformly. The pressure compensation effect of the drip irrigation devices can be optimized with the combination of soft silicon and labyrinth structures. However, for a drip irrigation devices composed of only hard labyrinth structures, the flow rate is changed largely with the length and the internal geometry of the labyrinth structure. Although a drip irrigation devices with only hard labyrinth structures can be fabricated simply, the changes of flow rates with internal fluid pressures are much larger than those of the drip irrigation devices with soft silicon. Because the drip irrigation devices with only labyrinth structures can be utilized widely through the optimization of the fluid pressure, the length of the structures, and the cross-sectional area of them, the study on the optimization can play an important role for enhancing the performance of the drip irrigation devices. In this study, experimental and numerical studies for investigating the performance of the drip irrigation devices had been conducted. In the experiments and numerical calculations(CFD), the variable parameters were the lengths of the labyrinth structures(#1~#8) and the fluid pressures(0.5~3.0 bar).

Design and Implementation of a Data-Driven Defect and Linearity Assessment Monitoring System for Electric Power Steering (전동식 파워 스티어링을 위한 데이터 기반 결함 및 선형성 평가 모니터링 시스템의 설계 구현)

  • Lawal Alabe Wale;Kimleang Kea;Youngsun Han;Tea-Kyung Kim
    • Journal of Internet of Things and Convergence
    • /
    • v.9 no.2
    • /
    • pp.61-69
    • /
    • 2023
  • In recent years, due to heightened environmental awareness, Electric Power Steering (EPS) has been increasingly adopted as the steering control unit in manufactured vehicles. This has had numerous benefits, such as improved steering power, elimination of hydraulic hose leaks and reduced fuel consumption. However, for EPS systems to respond to actions, sensors must be employed; this means that the consistency of the sensor's linear variation is integral to the stability of the steering response. To ensure quality control, a reliable method for detecting defects and assessing linearity is required to assess the sensitivity of the EPS sensor to changes in the internal design characters. This paper proposes a data-driven defect and linearity assessment monitoring system, which can be used to analyze EPS component defects and linearity based on vehicle speed interval division. The approach is validated experimentally using data collected from an EPS test jig and is further enhanced by the inclusion of a Graphical User Interface (GUI). Based on the design, the developed system effectively performs defect detection with an accuracy of 0.99 percent and obtains a linearity assessment score at varying vehicle speeds.

Development of Accident Response Information Sheets for Hydrogen Fluoride (불화수소에 대한 사고대응 정보시트 개발)

  • Yoon, Young Sam;Park, Yeon Shin;Kim, Ki Joon;Cho, Mun Sik;Hwang, Dong Gun;Yoon, Jun heon;Choi, Kyung Hee
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.18-26
    • /
    • 2014
  • We analyzed the demand of competent authorities requiring adequate technical information for initial investigation of chemical accidents. Reflecting technical reports on chemical accident response by environmental agencies in the U.S. and Canada, we presented information on environmental diffusion and toxic effects available for the first chemical accident response. Hydrogen fluoride may have the risk potential to corrode metals and cause serious burns and eye damages. In case of inhalation or intake, it could have severe health effects. The substance itself is inflammable, but once heated, it decomposes producing corrosive and toxic fume. In case of contact with water, it can produce toxic, corrosive, flammable or explosive gases and its solution, a strong acid, may react fiercely with a base. In case of hydrogen fluoride leak, the preventive measures are to decrease steam generation in exposed sites, prevent the transfer of vapor cloud and promptly respond using inflammable substances including calcium carbonate, sodium bicarbonate, ground limestone, dried soil, dry sand, vermiculite, fly ash and powder cement. The method for fire fighting is to suppress fire with manless hose stanchions or monitor nozzles by wearing the whole body protective clothing equipped with over-pressure self-contained breathing apparatus from distance. In case of transport accident accompanied with fire, evacuation distance is 1,600m radius. In cae of fire, fire suppression needs to be performed using dry chemicals, CO2, water spray, water fog, and alcohol-resistance foam, etc. The major symptoms by exposure route are dyspnoea, bronchitis, chemical pneumonia and pulmonary edema for respiration, skin laceration, dermatitis, burn, frostbite and erythema for eyes, and nausea, diarrhea, stomachache, and tissue destruction for digestive organs. In atmosphere, its persistency is low, and its bioaccumulation in aquatic organism is also low.

A Study on Dosimetry for Small Fields of Photon Beam (광자선 소조사면의 선량 측정에 관한 연구)

  • 강위생;하성환;박찬일
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.57-68
    • /
    • 1994
  • Purpose : The purposes are to discuss the reason to measure dose distributions of circular small fields for stereotactic radiosurgery based on medical linear accelerator, finding of beam axis, and considering points on dosimetry using home-made small water phantom, and to report dosimetric results of 10MV X-ray of Clinac-18, like as TMR, OAR and field size factor required for treatment planning. Method and material : Dose-response linearity and dose-rate dependence of a p-type silicon (Si) diode, of which size and sensitivity are proper for small field dosimetry, are determined by means of measurement. Two water tanks being same in shape and size, with internal dimension, 30${\times}$30${\times}$30cm$^3$ were home-made with acrylic plates and connected by a hose. One of them a used as a water phantom and the other as a device to control depth of the Si detector in the phantom. Two orthogonal dose profiles at a specified depth were used to determine beam axis. TMR's of 4 circular cones, 10, 20, 30 and 40mm at 100cm SAD were measured, and OAR's of them were measured at 4 depths, d$\sub$max/, 6, 10, 15cm at 100cm SCD. Field size factor (FSF) defined by the ratio of D$\sub$max/ of a given cone at SAD to MU were also measured. Result : The dose-response linearity of the Si detector was almost perfect. Its sensitivity decreased with increasing dose rate but stable for high dose rate like as 100MU/min and higher even though dose out of field could be a little bit overestimated because of low dose rate. Method determining beam axis by two orthogonal profiles was simple and gave 0.05mm accuracy. Adjustment of depth of the detector in a water phantom by insertion and remove of some acryl pates under an auxiliary water tank was also simple and accurate. TMR, OAR and FSF measured by Si detector were sufficiently accurate for application to treatment planning of linac-based stereotactic radiosurgery. OAR in field was nearly independent of depth. Conclusion : The Si detector was appropriate for dosimetry of small circular fields for linac-based stereotactic radiosurgery. The beam axis could be determined by two orthogonal dose profiles. The adjustment of depth of the detector in water was possible by addition or removal of some acryl plates under the auxiliary water tank and simple. TMR, OAR and FSF were accurate enough to apply to stereotactic radiosurgery planning. OAR data at one depth are sufficient for radiosurgery planning.

  • PDF