• Title/Summary/Keyword: HIPS

Search Result 254, Processing Time 0.021 seconds

Fatigue Characteristic of High Impact Polystyrene(HR-1360) Materials (HIPS(HR-1360) 재료의 피로 특성 평가)

  • Kang, Min-Sung;Koo, Jae-Mean;Seok, Chang-Sung;Park, Jae-Sil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.6
    • /
    • pp.763-769
    • /
    • 2010
  • In recent times, there has been considerable interest in HIPS (High Impact Polystyrene) materials for their use in construction of office equipments, home electronics, housing for electronics appliances, packing containers, etc. However, these materials suffer from problems caused by fatigue fracture. Further, their strength is substantially affected by environmental conditions. Therefore, in this study, the effect of temperature was analyzed by performing a tensile test and a fatigue test. It was observed that the yield strength, the ultimate strength, and the fatigue life decreased relatively with an increase in temperature. Further, an S-N curve can be predicted by using the results of the tensile test and a micro-Vickers hardness test.

One-stage Hip Reconstruction for Developmental Hip Dysplasia in Children over 8 Years of Age

  • Qadir, Irfan;Ahmad, Saeed;Zaman, Atiq uz;Khan, Chirag Muhammad;Ahmad, Shahzad;Aziz, Amer
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.260-268
    • /
    • 2018
  • Purpose: This study was performed to assess the clinical and radiological outcomes following one-stage hip reconstruction, consisting of open reduction femoral shortening and pelvic osteotomy, for neglected developmental dislocation of the hip (DDH). Materials and Methods: This is a retrospective analysis of 77 hips in 65 patients (46 females and 19 males; 12 had bilateral dislocations), operated at a Ghurki Trust Teaching Hospital in Pakistan between 2013 and 2015. The average age at surgery was $11.02{\pm}3.43$ years. According to the Tonnis classification, there were 10, 14, 22, and 31 patients in grades 1, 2, 3, and 4, respectively. The pelvic procedure utilized in this study was triple osteotomy (47 hips) followed by double and Salter osteotomy (18 and 12 hips, respectively). Postoperative evaluations were conducted using the modified MacKay's scoring system (functional outcomes) and Severin's scoring method (radiological assessment). Results: Postoperatively, there were 38 (49.4%), 19 (24.7%), 14 (18.2%), and 6 (7.8%) hips in Severin grade I, II, III and IV, respectively. According to the modified McKay criteria, there were 22 hips (28.6%) in excellent condition, 44 (57.1%) in good condition, 9 (11.7%) in fair condition and 2 (2.6%) in poor condition. Both patients with poor outcomes had an unstable, painful hip with evidence of avascular necrosis of the femoral head. Conclusion: Based on the results presented here, we recommend the single stage procedure of open reduction, femoral shortening and pelvic osteotomy for treatment of DDH in older children with good to excellent functional and radiological outcomes.

Electrical Properties of High Impact Polystyrene (HIPS)/Thermoplastic Urethane (TPU) Blend with Poly(styrene-co-maleic anhydride) as a Compatibilizer (상용화제 Poly(styrene-co-maleic anhydride) 첨가에 따른 고충격 폴리스티렌 (HIPS)/Thermoplastic Urethane (TPU) 블렌드의 전기적 특성)

  • Lee, Young-Hee;Lee, Tae-Hee;Kim, Won-Jung;Kim, Tae-Young;Yoon, Ho-Gyu;Suh, Kwang-S.
    • Polymer(Korea)
    • /
    • v.32 no.3
    • /
    • pp.251-255
    • /
    • 2008
  • This study suggested antistatic material which can increase anti-static properties and mechanical strength by mixing polystyrene for conveying electronic stuffs with metal salt and ester compound as a anti-static agent. We studied about mechanical, thermal and electrical characteristics by changing the contents of MAH of poly(styrene-co-maleic anhydride), compatibilizer. As the result of measuring residue space charge of the blends of HIPS(75)/TPU(25)/poly(styrene-co-maleic anhydride)(MAH weight ratio : 25, 32, 43.5 wt%), we could find small residue charge in the blend which MAH(25 wt%) was added and it showed the highest values in tensile strength. Additionally we found out the material to which compatibilizer was added kept better anti-static properties than one to which compatibilizer was not added. In the event we could confirm that the adding of PS-co-MAH enables two polymers were mixed well when HIPS/TPU was blended and anti-static agent made easier dissipative in the blend.

A Study on the Ease in Jacket Bodice Pattern for Abdomen-obese Middle-aged Men from Virtual Appearance Evaluation (가상착의 평가에 따른 복부비만 중년남성의 재킷 길 원형 여유량 설정)

  • Lim, Ji-Young
    • Fashion & Textile Research Journal
    • /
    • v.12 no.6
    • /
    • pp.789-795
    • /
    • 2010
  • The purpose of this study was to examine the appropriate surplus of clothing for a jacket bodice pattern of middle-aged obese men by using the 3D virtual twin and virtual garment simulation system. The results were as follows ; 1. BMI rate of middle-aged males was 28.13 which was equivalent to mild obesity, whereas WHR(W/H ratio from waist to hips) rate was near 1.00 which was highly dangerous against their obesity. In case of middle-aged obese men, the WHR was significantly higher than the entire middle-aged men's average and the section shape in which their thickness was relatively more than width. 2. As a result of appearances evaluation through virtual garment simulation, the cut-off amount of the side seam and the center back was regulated accordingly. Hereby, the final tolerance range was set up at 21.15 cm at the hips, so that the appearances became better and the bilateral distribution of the cross section and space length was formed symmetrically. Especially in case of increasing the cross amount of hems to produce a natural silhouette of the waist-to-hips parts, the ease of buttocks was judged to be moderate, but it turned out that a wavy cross section was made and the silhouette was not good. Thus it was found to be not good that the ease of the hips became excessively increased in proportion as circumference of waist and belly were increased in obesity. The use of the virtual twin made it impossible to comprehend the appearances and ease correspondent to motions. In order to evaluate wearing fitness, therefore, the system should be improved so as to change arm positions and perform various motions.

Analysis at Effects of Task Skills on Osteoporosis Tests (업무 숙련도가 골다공증 검사에 미치는 영향 분석)

  • Kim, Hyeon-Jin;Kim, Won-Tae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.31-37
    • /
    • 2020
  • This study was conducted to examine the kinds and the frequency of incorrect outcomes occurring depending examiners' skills, in testing osteoporosis by using Dual Energy X-ray Absorptiometry(DXA) and improve frequently occurring errors by educating them. The results of an analysis show that the outcomes from the test of hips in patients with wrong postures or some regions with pressure fracture and degenerative changes were often included, even though they should be excluded, and that surgical instruments were also included in the analysis, though they should be excluded from resulting values. Of them, the errors most often found were those about patients' postures (n=56, 6 cases for spines and 50 cases for hips), followed by those about analytical processes (n=37, 35 cases for spines and 2 cases for hips), and then those about regions of interest (n=33, 28 cases for spines and 5 cases for hips). There were, however, no errors caused by the defectiveness of quality control.

An Analysis on the Changes of Knees and Hip Joint Surface according to Elderly Women's Movements (노년 여성의 동작에 따른 무릎 및 고관절 주변 체표 길이 변화 분석)

  • Jang, Ji Hyeon;Jung, Hee Kyeong;Park, Jung Hyun;Lee, Jeong Ran
    • Fashion & Textile Research Journal
    • /
    • v.22 no.2
    • /
    • pp.222-232
    • /
    • 2020
  • This study analyzes changes in the knees, hips, and hip joint length according to the different angles of bending knees by 45°, 90°, and 135° respectively for knees, hips, and the hip joint that have high fracture rates when falling down. The research subjects were 10 elderly women in their 60s (or older) that obtain data collected through direct measurement. For analysis, the study drew a diagram of elongation and shrinkage based on changes and change rate from a straight posture (0°) and conducted a statistical analysis on differences of body surface length by zone according to movements. The more the knees were bent, the vertical surface length in front of the knees, the horizontal surface length above the knee line, the horizontal body surface length below the knee lines on the back, and the vertical surface lengths between front side lines and the side lines increased; however, the vertical surface length on the back decreased. For the hip joint, the difference in the vertical surface length was more distinctive when compared to the horizontal. Finally, the horizontal surface length increased below the hips and the vertical surface length increased in most areas except the sidelines and the front. The result of the change in body surface length according to the movements of this study can be utilized in the development of the motion-variable protector.

Triboelectrostatic Separation of Mixed Three Kinds of Plastics by a Two-stage Separation Process (2단계(段階) 분리공정(分離工程)에 의한 3종(種) 혼합(混合)플라스틱의 마찰하전(摩擦荷電) 정전선별(靜電選別))

  • Park, Chul-Hyun;Jeon, Ho-Seok;Baek, Sang-Ho;Park, Jai-Koo
    • Resources Recycling
    • /
    • v.16 no.5
    • /
    • pp.57-64
    • /
    • 2007
  • Triboelectrostatic separation of mixed three kinds of plastics, PVC, PET and PMMA, in the range of similar gravity has been performed through a two-stage separation process. Polypropylene (PP) and high-impact polystyrene (HIPS) were found to be the most effective materials for a tribo-charger in the separation of PVC, PET and PMMA. In the 1st stage using the PP cyclone charger, PVC grade and recovery depended considerably on the air velocity (10 m/s), the relative humidity (<30%), the electric field (>200 kV/m) and the splitter position (+2 cm from the center) in the triboelelctrostatic separator unit. At an optimum condition a PVC grade of 99.6% and a recovery of 97.5% was achieved. In the 2nd stage using the HIPS cyclone charger, a PMMA grade of 98.3% and a recovery of 97.0% was obtained under the conditions of 10m/s air velocity, over 250 kV/m electric field, central splitter position and less than 40% relative humidity.

Periprosthetic Occult Femoral Fracture: An Unknown Side Effect of Press-Fit Fixation in Primary Cementless Total Hip Arthroplasty

  • Ho Hyun Yun;Woo Seung Lee;Young Bin Shin;Tae Hyuck Yoon
    • Hip & pelvis
    • /
    • v.35 no.2
    • /
    • pp.88-98
    • /
    • 2023
  • Purpose: The objectives of this study were to examine the prevalence and risk factors for development of periprosthetic occult femoral fractures during primary cementless total hip arthroplasty (THA) and to assess the clinical consequences of these fractures. Materials and Methods: A total of 199 hips were examined. Periprosthetic occult femoral fractures were defined as fractures not detected intraoperatively and on postoperative radiographs, but only observed on postoperative computed tomography (CT). Clinical, surgical, and radiographic analysis of variables was performed for identification of risk factors for periprosthetic occult femoral fractures. A comparison of stem subsidence, stem alignment, and thigh pain between the occult fracture group and the non-fracture group was also performed. Results: Periprosthetic occult femoral fractures were detected during the operation in 21 (10.6%) of 199 hips. Of eight hips with periprosthetic occult femoral fractures that were detected around the lesser trochanter, concurrent periprosthetic occult femoral fractures located at different levels were detected in six hips (75.0%). Only the female sex showed significant association with an increased risk of periprosthetic occult femoral fractures (odds ratio for males, 0.38; 95% confidence interval, 0.15-1.01; P=0.04). A significant difference in the incidence of thigh pain was observed between the occult fracture group and the non-fracture group (P<0.05). Conclusion: Occurrence of periprosthetic occult femoral fractures is relatively common during primary THA using tapered wedge stems. We recommend CT referral for female patients who report unexplained early postoperative thigh pain or developed periprosthetic intraoperative femoral fractures around the lesser trochanter during primary THA using tapered wedge stems.

Dislocation after Revision Total Hip Arthroplasty: A Comparison between Dual Mobility and Conventional Total Hip Arthroplasty

  • Hyun Sik Shin;Dong-Hong, Kim;Hyung Seok Kim;Hyung Seob Ahn;Yeesuk Kim
    • Hip & pelvis
    • /
    • v.35 no.4
    • /
    • pp.233-237
    • /
    • 2023
  • Purpose: The objective of this study was to analyze the results from a cohort of patients who underwent a revision total hip arthroplasty (THA) using a dual mobility cup (DMC) implant. Materials and Methods: A retrospective review of revised THAs was conducted using the database from a single tertiary referral hospital. A total of 91 revision THAs from 91 patients were included in the study. There were 46 male hips and 45 female hips. The mean age was 56.3±14.6 years, and the mean follow-up period was 6.4±5.9 years. In performance of revision THAs, the DMC implants were used in 18 hips (19.8%), and the conventional implants were used in 73 hips (80.2%). Results: During the follow-up period, three dislocations were identified, and the overall dislocation rate was 3.3%. Early dislocation (at one month postoperatively) occurred in one patient, while late dislocation (at a mean of 7.5 years) occurred in two patients. There was no occurrence of dislocation in the DMC group (0%), and three dislocations were detected in the conventional group (4.1%). However, no significant difference in the rate of dislocation was observed between the two groups (P=0.891). Conclusion: Although the rate of dislocation was higher in the conventional group, there were no statistically significant differences between the two groups due to the small number of patients. Nevertheless, we believe that the dual mobility design is advantageous in terms of reducing dislocation rate and can be recommended as an option for a revision THA.

Kinematical Analysis of Men's Pole Vault Event (장대높이뛰기 경기의 운동학적 분석)

  • Lim, Kyu-Chan
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.3
    • /
    • pp.15-26
    • /
    • 2003
  • This study was conducted to investigate the performance times, CM position and CM speed, pole chord length and pole chord angle, whole body angular momentum(X axis), and grip width in pole vault event according to the event and phase; touch down, pole plant, take-off, maximum pole bending pole straight, pole release, peak height, and foot contact, pole contact, free flight. The pole vaulting of four male elite vaulters including six trial were filmed using two video digital cameras at 60 Hz at 56th national athletic match, and data were collected through the DLT method of three dimensional cinematography. In general the better jumper is, the longer the performance time is. And the greater CM speed is, and the better his transformation ability of CM horizontal speed into vertical speed is. As he uses a longer pole, his grip is higher, and it is a enough for him to rock back his body, so that he pulls and pushes the pole well keeping his hips close to. An greater maximum angular momentum and early positioning of the hips parallel to the bar makes his body far side of the bar and his bar clearance easier. Specially our national jumper needs to have more powerful braking force during foot contact phase, and take his body on the pole after maximum pole bending, and pull and push the pole strongly keeping his hips close to. Also he needs to have stronger muscular strength in order to control the longer pole and use the pole of proper tension more efficiently.