• Title/Summary/Keyword: HIFU(High Intensity Focused Ultrasound)

Search Result 24, Processing Time 0.022 seconds

Deep Burn Injuries on the Lower Abdomen after HIFU Treatment for Uterine Myoma (자궁 근종에 대한 HIFU 치료 후 발생한 하부 복부의 심부 화상)

  • Yu, Sung Hoon;Kim, Dong Chul
    • Journal of the Korean Burn Society
    • /
    • v.23 no.2
    • /
    • pp.64-67
    • /
    • 2020
  • High-intensity focused ultrasound (HIFU) has been regarded as a non-invasive uterine-preserving treatment for women with uterine myoma. Numerous studies have reported that it is a relatively safe and effective treatment for uterine myoma. However, severe complications, such as deep thermal burn injuries, bowel perforation, and bladder injury, were reported on rare occasions. We report a case of a 4th degree burn on the lower abdomen after HIFU treatment for uterine myoma. Physicians must consider the possibility of deep thermal burn injuries when managing uterine myoma with HIFU.

Experiences of High Intensity Focused Ultrasound (HIFU) Treatment in Benign Uterus Neoplasms (자궁양성종양 환자의 고강도 초음파 집속술(HIFU) 치료 경험)

  • Park, Seo A;Kim, Hye Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.403-411
    • /
    • 2018
  • The purpose of this study was to identify the experience of patients with uterine benign neoplasms in response to high-intensity focused ultrasound treatment. The study participants were patients who received high-intensity focused ultrasound treatment after diagnosis of benign uterine neoplasms and were contacted through purposive techniques. Five patients agreed to participate in this study. Data were collected from February, 2018 to May, 2018 at Women's hospital in D city. The interview data were analyzed by the phenomenological analysis method developed by Colaizzi using open-ended questions during in-depth interviews. Three categories emerged from the analysis using Colaizzi's method: 1) Discomfort. 2) Ambivalence. 3) Will and need. These study results contribute to a deeper understanding of the experience of patients with uterine benign neoplasms in response to high-intensity focused ultrasound treatment. Therefore, it should be developed as part of an effective nursing education program to provide evidence-based guidelines and nursing interventions that alleviate health problems in patients receiving high-intensity focused ultrasound treatment and proper nursing understanding of the development of new treatment methods for woman's health.

Comparative Study on Transcatheter Arterial Chemoembolization, Portal Vein Embolization and High Intensity Focused Ultrasound Sequential Therapy for Patients

  • Cui, Lin;Liu, Xing-Xiang;Jiang, Yong;Wu, Xing-Jun;Liu, Jian-Jun;Zhou, Xiang-Rong;He, Xue-Jun;Huang, Xin-En
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.12
    • /
    • pp.6257-6261
    • /
    • 2012
  • Objective: To investigate the safety and efficacy of transcatheter arterial chemoembolization (TACE), combined with portal vein embolization (PVE), and high intensity focused ultrasound (HIFU) sequential therapy in treating patients with hepatocellular carcinoma (HCC). Methods: Patients with inoperative HCC were treated by two methods: in the study group with TACE first, then PVE a week later, and then TACE+PVE every two months as a cycle, after 2~3 cycles finally HIFU was given; in the control group only TACE+PVE was given. Response (CR+PR), and disease control rate (CR+PR+SD), side effects, overall survival and time to progress were calculated. Results: Main side effects of both groups were nausea and vomiting. No treatment related death occurred. In the study group, 32 patients received TACE for overall 67 times, PVE 64 times, and HIFU 99 times; on average 2.1, 2 and 3.1 times for each patient, respectively. In the control group, 36 patients were given TACE 78 times and PVE 74 times, averaging 2.2 and 2.1 times per patient. Effective rate: 25.0% in study group and 8.3% in control group (p>0.05). Disease control rates were 71.9% and 44.4%, respectively (p<0.05). In patients with portal vein tumor thrombus, the rate reduced over 1/2 after treatment was 69.2%(9/13) in the study and 21.4%(3/14) in the control group (p<0.05). Rate of AFP reversion or decrease over 1/2 was 66.7%(16/24) in study and 37%(10/27) (p<0.05) in control group. Median survival time: 16 months in study and 10 months in control group. PFS was 7months in study and 3 months in control group. Log-rank test suggested that statistically significant difference exists between two groups (p=0.024). 1-, 2- and 3-year survival rates were 56.3%, 18.8% and 9.3% in study, while 30.6%, 5.6% and 0 in control group, respectively, with statistically significant difference between two groups (by Log-rank, p = 0.014). Conclusions: The treatment of TACE+PVE+HIFU sequential therapy for HCC increases response rate, prolong survival, and could thus be a safe and effective treatment for advanced cases.

Development of High Intensity Focused Ultrasound (HIFU) Mediated AuNP-liposomal Nanomedicine and Evaluation with PET Imaging

  • Ji Yoon Kim;Un Chul Shin;Ji Yong Park;Ran Ji Yoo;Soeku Bae;Tae Hyeon Choi;Kyuwan Kim;Young Chan Ann;Jin Sil Kim;Yu Jin Shin;Hokyu Lee;Yong Jin Lee;Kyo Chul Lee;Suhng Wook Kim;Yun-Sang Lee
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.9 no.1
    • /
    • pp.9-16
    • /
    • 2023
  • Liposomes as drug delivery system have proved useful carrier for various disease, including cancer. In addition, perfluorocarbon cored microbubbles are utilized in conjunction with high-intensity focused-ultrasound (HIFU) to enable simultaneous diagnosis and treatment. However, microbubbles generally exhibit lower drug loading efficiency, so the need for the development of a novel liposome-based drug delivery material that can efficiently load and deliver drugs to targeted areas via HIFU. This study aims to develop a liposome-based drug delivery material by introducing a substance that can burst liposomes using ultrasound energy and confirm the ability to target tumors using PET imaging. Liposomes (Lipo-DOX, Lipo-DOX-Au, Lipo-DOX-Au-RGD) were synthesized with gold nanoparticles using an avidin-biotin bond, and doxorubicin was mounted inside by pH gradient method. The size distribution was measured by DLS, and encapsulation efficiency of doxorubicin was analyzed by UV-vis spectrometer. The target specificity and cytotoxicity of liposomes were assessed in vitro by glioblastoma U87mg cells to HIFU treatment and analyzed using CCK-8 assay, and fluorescence microscopy at 6-hour intervals for up to 24 hours. For the in vivo study, U87mg model mouse were injected intravenously with 1.48 MBq of 64Cu-labeled Lipo-DOX-Au and Lipo-DOX-Au-RGD, and PET images were taken at 0, 2, 4, 8, and 24 hours. As a result, the size of liposomes was 108.3 ± 5.0 nm at Lipo-DOX-Au and 94.1 ± 12.2 nm at Lipo-DOX-Au-RGD, and it was observed that doxorubicin was mounted inside the liposome up to 52%. After 6 hours of HIFU treatment, the viability of U87mg cells treated with Lipo-DOX-Au decreased by around 20% compared to Lipo-DOX, and Lipo-DOX-Au-RGD had a higher uptake rate than Lipo-DOX. In vivo study using PET images, it was confirmed that 64Cu-Lipo-DOX-Au-RGD was taken up into the tumor immediately after injection and maintained for up to 4 hours. In this study, drugs released from liposomes-gold nanoparticles via ultrasound and RGD targeting were confirmed by non-invasive imaging. In cell-level experiments, HIFU treatment of gold nanoparticle-coupled liposomes significantly decreased tumor survival, while RGD-liposomes exhibited high tumor targeting and rapid release in vivo imaging. It is expected that the combination of these models with ultrasound is served as an effective drug delivery material with therapeutic outcomes.

Finite element analysis for acoustic and temperature characteristics of a piezoelectric HIFU transducer at 10 MHz (10 MHz용 압전 HIFU 트랜스듀서의 음향 및 온도 특성에 대한 유한요소해석)

  • Jong-Ho Kim;Il-Gok Hong;Ho-Yong Shin;Hyo-Jun Ahn;Jong-In Im
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.3
    • /
    • pp.116-123
    • /
    • 2023
  • A high intensity focuses ultrasound (HIFU) is one of the emerging technologies in the biomedical field. The piezoelectric HIFU transducer is a device that utilizes the thermal energy generated by high ultrasound energy. Recently an operating frequency of the HIFU transducer is to expand above a 7 MHz. In this study, the acoustic pressures and temperature distributions in the tissue that generated by the HIFU transducer at 10 MHz were calculated with the finite element method. In addition, the pressure focusing characteristics of the device were analyzed. The geometrical variables are the piezomaterial thickness, lens shape, water height, and film thickness. The results shown that the acoustic pressure increased and saturated gradually when the height/radius (HL/RL) ratio of the lens increased. Moreover, the focal area was gradually decreases with HL/RL ratio of the lens. In case of the optimized HIFU transducer, the maximum pressure and temperature were analyzed about 19 MPa and 65℃ respectively. And the -3 dB focused distances in the axial and lateral direction are around 2.3 mm and 0.23 mm respectively.

Effects of a video education program for patients with benign uterine tumors receiving high-intensity focused ultrasound treatment (고강도 집속 초음파 치료를 받는 자궁양성종양 환자의 동영상 교육프로그램 효과)

  • Hong, Mi Suk;Park, Hyoung Sook;Cho, Young Suk
    • Women's Health Nursing
    • /
    • v.26 no.2
    • /
    • pp.151-160
    • /
    • 2020
  • Purpose: The purpose of this study was to examine the effects of a video education program in women receiving high-intensity focused ultrasound (HIFU) treatment. Methods: This was a quasi-experimental study with a nonequivalent control group non-synchronized design. The participants were 54 patients who had benign uterine tumors and adenomyosis. The data were collected from June to August 2018. A 10-minute video education program on HIFU and post-procedural care was developed based on the literature. The experimental group was provided the video education program with a question-and-answer session for 10 minutes after viewing the video. The control group received usual care (i.e., verbal instructions on post-procedural self-care). The questionnaire survey was conducted twice: before the educational program and before being discharged from the hospital. Differences in uncertainty, emotions, and self-efficacy among patients were analyzed. Data were analyzed using the chi-square test, Shapiro-Wilk test, paired t-test, and t-test with SPSS version 23.0. Results: The participants in the experimental group showed a decrease in uncertainty (t=4.33, p<.001), improvements in anxiety (t=-4.07, p<.001) and depression (t=-3.55, p<.001), and an enhancement of self-efficacy (t=-4.39, p<.001) compared to the control group. Conclusion: This nursing intervention was effective at reducing uncertainty, improving emotions, and enhancing self-efficacy. This intervention is feasible for use in nursing practice as an aid for patients when considering treatment methods.

Clinical Outcome of Treatment for Stage IIA, IIB and III Osteosarcomas (Comparative Studies between Invasive Surgical Treatment and Non-invasive HIFU Technique) (진행된 장관골 골육종의 수술 및 비수술적 강력 집속 초음파 치료의 장기 추적 결과)

  • Wenzhi, Chen;Wei, Wang;Zhibiao, Wang;Hui, Zhu;Kequan, Li;Hao, Piao Xiang;Haibing, Su;Chengbing, Jin;Feng, Wu;Jin, Bai;Rhee, Seung-Koo;Kang, Yong-Koo;Bahk, Won-Jong;Chung, Yang-Guk;Huh, Sung-Woo;Lee, Eun-Sang
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.12 no.1
    • /
    • pp.37-46
    • /
    • 2006
  • Purpose: To evaluate the end results between the surgical treatment with neo-adjuvant chemotherapy in Korea and non-invasive high intensity focused ultrasound (HIFU) technique in China for osteogenic sarcomas. Materials and Methods: The surgical treatment with neoadjuvant chemotherapy for total 67 cases (4 IIA, 58 IIB, and 5 III) in Korea since 1993 and the HIFU therapy for total 71 cases (57 II and 14 III) in China since 1997 was performed. In Korea, neo-adjuvant chemotherapy in 66 cases out of total 67 patients, but the adjuvant chemotherapy in only one case was done. On the contrary, in China, full chemotherapy for more than 9 times for 37 patients with stage II out of total 71 cases, but for less than 8 times of partial chemotherapy for 23 patients (stage II) and 14 patients (stage III) was done. The surgical treatment in total 67 Korean patients was done with wide resection and reconstruction for 56 patients, but wide resection without reconstruction for 5 patients and amputation for 6 patients. In china, total 71 patients was treated with average 1.5 times (1~4 times) of HIFU, and if there are some evidences of residual tumor after HIFU with following MRI, the second HIFU therapy was given 2~4 weeks later. After then, the bony defect was in no touch, keep bracing for long time expecting regeneration. All of them were followed for average 46 Mo (12~150 Mo) in Korea, but followed for average 22 Mo (9 years~8 months) in China. Results: The 5 year survival rate (stage II), was average 92.7% (IIA 100%, IIB 85.5%) in Korea series, and average 78.7% (full chemotherapy 91.8%, part chemotherapy 56.6%) in China series. The 3 year survival rate (stage III) was 20% in Korea and 7.1% in China. So, the final overall survival rate was 65.2% in Korea and 51.8% in China. The overall functional outcome score by ISOLS was 24.3 (81%) in Korea and 19.8 (73%) in China. There are 25.4% (17/67 cases) of complications in Korea and 31% (27 complications in 22 patients out of total 71 cases) in China after each treatment. Conclusions: The end results of Korea series which was treated with neoadjuvant chemo- and surgical methods are better than that of non-invasive thermal ablation in china. But we also believe the HIFU, as one of, was also effective to decrease the local recurrence and symptomatic releaf for stage II or even in III of osteogenic sarcomas.

  • PDF

The Development of Ultrasonic Hyperthermia Simulator to Improve the Efficiency of Ultrasonic Therapy (초음파 치료의 효율성 향상을 위한 초음파 온열 시뮬레이터 개발)

  • Yu, W.J.;Noh, S.C.;Jung, D.W.;Park, J.H.;Choi, M.J.;Choi, H.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.5
    • /
    • pp.418-427
    • /
    • 2009
  • As many people are westernizing their life style and food consumption habits, a number of patients who have malignant tumors which grow very rapidly and hazardously destroy the human body are increasing. Ultrasonic hyperthermia is not only one of the tumor treatment methods which employs the non-radioactive ultrasonic waves to increase the temperature at the tumor region up to $40\sim45^{\circ}C$ to destroy and suppress tumor cells but also has been proved by many studies. Due to the rapid development of High Intensity Focused Ultrasound(HIFU), the ultrasound hyperthemia extensively boosts its applications in clinical field. For those reasons, Computed simulation factor should be needed before inspection to patients. To prove efficiency of ultrasonic hyperthermia, precise acoustic field measurement considering tissue characteristics and a heating experiment with tissue mimicking material phantom were conducted for effectiveness of simulation program. Finally, in this study, the computer simulation program verified the anticipated temperature effects induced by ultrasound hyperthermia. In the near future, it is hoped that this simulation program could be utilized to improve the efficiency of ultrasound hyperthermia.

Animal Skin Irritation and Skin Sensitization Tests of High Intensity Focused Ultrasound System Cartridges (집속형초음파자극시스템 카트리지의 동물실험을 통한 피부자극시험 및 피부 감작성시험)

  • Jun-tae, Kim;Ju-hee, Kim;Kyu-tai, Joo;Kyung-ah, Kim;Ahnryul, Choi;Jae-hyun, Jo;Jin-houng, Jeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.477-484
    • /
    • 2022
  • In this study, the cartridge part of the focused ultrasound stimulation system was used as a sample to conduct a skin irritation test and a skin sensitization test through animal experiments among the tests related to GLP (Good Laboratory Practice), a medical device safety evaluation standard. The test was conducted after IACUC approval using 6 female New Zeland White Rabbits. The polar and non-polar stimulation indices were all '0.0'. In addition, in the case of skin sensitization evaluation, 30 guinea pigs approved by IACUC were divided into control and experimental groups, and all induction and induction steps were applied using the eluate itself without separate dilution of the test sample and blank test solution. As a result of the experiment, the skin reaction grade of the control animal was 0 grade, and there was no animal showing more than 1 grade in the skin reaction of the test animal. As a result of both tests, no abnormal skin symptoms were observed, and when applied to the human body to treat patients, the test materials used in the tests will investigate the stability of whether any diseases that cause skin abnormal symptoms will occur.

A study for implementation of ultrasonic transducer in the prostate cancer hyperthermia (전립선암의 온열치료를 위한 초음파변환기 개발에 관한 연구)

  • Park, Mun-Kyu;Noh, Si-Cheol;Park, Jae-Hyun;Choi, Heung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.377-384
    • /
    • 2009
  • The ultrasonic hyperthermia for oncology has been developed and studied. The HIFU(high intensity focused ultrasound) is the most recent method to treat the tumor by using ultrasound. In this study, an insertion-type transducer for treating a prostate cancer, which can focus the ultrasonic beam mechanically and electrically, was designed and developed. The developed transducer was composed of three arrays, and each array has 32 elements. For the purpose of the mechanical focusing, both side arrays are slanted to the center array by $15^{\circ}$. With this structure, NFL(near field length) was set up as 30 mm. The PZT-4 and two matching layers were used, and the backing layer was excepted to prevent energy losses. The acoustic field analysis and the heating test were performed to evaluate the performance of developed transducer. The shape of an acoustic field, peak pressure, and acoustic pressure distribution were compared with numerical simulation. The NFL was 32 mm, the beam width was 5 mm, focal area was $40\;mm^2$, and peak pressure was 5.5 MPa. With heating by using developed transducer, the temperature increased up to $33^{\circ}C$ at focal zone. As a result of this study, the usefulness of suggested transducer for prostate cancer hyperthermia was confirmed by the acoustic field analysis and the heating test with TMM(tissue mimicking) phantom.