• Title/Summary/Keyword: HHF

Search Result 20, Processing Time 0.02 seconds

HIGH HEAT FLUX TEST WITH HIP BONDED 35X35X3 BE/CU MOCKUPS FOR THE ITER BLANKET FIRST WALL

  • Lee, Dong-Won;Bae, Young-Dug;Kim, Suk-Kwon;Jung, Hyun-Kyu;Park, Jeong-Yong;Jeong, Yong-Hwan;Choi, Byung-Kwon;Kim, Byoung-Yoon
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.662-669
    • /
    • 2010
  • To develop the manufacturing methods for the blanket first wall (FW) of the International Thermonuclear Experimental Reactor (ITER) and to verify the integrity of the joint, Be/Cu mockups were fabricated and tested at the KoHLT-1 (Korea Heat Load Test facility), a graphite heater facility located at the Korea Atomic Energy Research Institute (KAERI). Since Be and Cu joining is the focus of the present study, the fabricated mockups had a CuCrZr heat sink joined with three Be tiles as an armor material, unlike the original ITER blanket FW, which has a stainless steel structure and coolant tubes. Hot isostatic pressing (HIP) was carried out at $580^{\circ}C$ and 100 MPa for 2 hours as the method for Be/Cu joining. Three interlayers, namely, $1{\mu}mCr/10{\mu}mCu$, $1{\mu}mTi/0.5{\mu}mCr/10{\mu}mCu$, and $5{\mu}mTi/10{\mu}mCu$ were applied as a coating to the Be tiles by a physical vapor deposition (PVD) method. A shear test was performed with the specimens, which were fabricated by the same methods as those used to fabricate the mockups. The average values were 125 MPa to 180 MPa, and the samples with the $1{\mu}mCr/10{\mu}mCu$ interlayer showed the lowest value. No defect or delamination was found in the joints of the mockups by the developed ultrasonic test using a flat-type probe with a 10 MHz frequency and a 0.25 inch diameter. High heat flux (HHF) tests were performed at $1.0\;MW/m^2$ heat flux for each mockup using the given conditions, and the results were analyzed by ANSYS-CFX code. For the test criteria, an expected fatigue lifetime about 1,000 cycles was obtained by analysis with ANSYS-mechanical code. Mockups using the interlayers of $1{\mu}mTi/0.5{\mu}mCr/10{\mu}mCu$ and $5{\mu}mTi/10{\mu}mCu$ survived up to 1,100 cycles over the required number of cycles. However, one of the Be tiles in the other two mockups using the $1{\mu}mCr/10{\mu}mCu$ interlayer was detached during the screening test, and others were detached by discharge after 862 cycles. The integrity of the joints using the proposed interlayers was proven by the HHF test, but the other interlayer requires more study before it can be used for the joining of Be to Cu. Moreover, it was confirmed that the measured temperatures agreed well with the analysis temperatures, which were used to estimate the lifetime and that the developed facility showed its capability of the long time operation.

Cardiovascular Outcomes of Sodium-Glucose Cotransporter-2 Inhibitors Therapy in Patients With Type 2 Diabetes Mellitus and Chronic Kidney Disease: A Systematic Review and Updated Meta-Analysis

  • Nicole Felix;Mateus M. Gauza;Larissa Teixeira;Maria Eduarda S. Guisso;Alleh Nogueira;Caroline S. Dagostin;Amanda Godoi;Sandro A. G. Ribeiro;Juan C. Duque;Jose A. Moura-Neto;Rhanderson Cardoso
    • Korean Circulation Journal
    • /
    • v.54 no.9
    • /
    • pp.549-561
    • /
    • 2024
  • Background and Objectives: The efficacy of sodium-glucose cotransporter-2 inhibitors (SGLT2i) may depend on renal function, and this raises theoretical concern over its effects on cardiovascular outcomes in patients with type 2 diabetes mellitus (T2DM) and chronic kidney disease (CKD). Methods: This systematic review and updated meta-analysis of randomized controlled trials (RCTs) compared cardiovascular outcomes of patients with T2DM and CKD treated with SGLT2i to placebo. PubMed, Embase, and Cochrane were systematically searched. Prespecified subgroup analyses were performed in strata of estimated glomerular filtration rate (eGFR) of <45 mL/min/1.73 m2 and 45 to 59 mL/min/1.73 m2. Results: Nine RCTs comprising 29,146 patients were selected. Average follow-up ranged from 0.75 to 4.2 years. SGLT2i were shown to reduce the risk of all-cause mortality (hazard ratio [HR], 0.88; 95% confidence interval [CI], 0.79-0.97; p=0.01), the composite of cardiovascular mortality or hospitalizations for heart failure (HHF: HR, 0.71; 95% CI, 0.65-0.78; p<0.001), cardiovascular mortality (HR, 0.86; 95% CI, 0.76-0.98; p=0.02), HHF (HR, 0.62; 95% CI, 0.55-0.71; p<0.001), major adverse cardiovascular events (HR, 0.85; 95% CI, 0.77-0.94; p=0.002), stroke (HR, 0.76; 95% CI, 0.59-0.97; p=0.03), and myocardial infarction (HR, 0.78; 95% CI, 0.67-0.91; p=0.001). These findings were consistent over strata of eGFR, albeit with a lower incidence of stroke in patients treated with SGLT2i with eGFR <45 mL/min/1.73 m2 (p-value for interaction=0.04). Conclusions: Compared with a placebo, patients with T2DM and CKD treated with SGLT2i experience a reduction in all-cause mortality, cardiovascular mortality, and HHF.

Preventive Effect of an SGLT2 Inhibitor on Cardiovascular Disease in an Observational Study: Results from a Korean Population (관찰연구에서 확인된 SGLT2 억제제의 심혈관질환 예방효과: 한국인의 결과를 중심으로)

  • Ha, Kyoung Hwa;Kim, Dae Jung
    • The Journal of Korean Diabetes
    • /
    • v.19 no.3
    • /
    • pp.135-139
    • /
    • 2018
  • The sodium-glucose cotransporter-2 inhibitor (SGLT2i) is a new anti-hyperglycemic agent that have function to concomitantly inhibit the reabsorption of glucose and sodium in the renal proximal convoluting tubule. Recent two cardiovascular outcome trials showed that a lower risk of cardiovascular events with SGLT2i in people with type 2 diabetes. In addition, prior real-world data demonstrated similar SGLT2i effects, but these studies were limited to the United States and Europe. Thus, the CVD-REAL (Comparative Effectiveness of Cardiovascular Outcomes in New Users of Sodium-Glucose Cotransporter-2 Inhibitors) 2 Study was investigated cardiovascular outcomes in those initiated on SGLT2i versus other glucose-lowering drugs (oGLDs) across 6 countries in the Asia Pacific, the Middle East, and North American regions. In Korea, 336,644 episodes of initiation in SGLT2i or oGLD group between September 2014 and December 2016 were identified in Korea National Health Insurance database after propensity score matching. SGLT2i users was associated with a lower risk of all-cause death (hazard ratio [HR], 0.72; 95% confidence interval [CI], 0.67~0.77), hospitalization for heart failure (HHF) (HR, 0.87; 95% CI, 0.82~0.92), all-cause death or HHF (HR, 0.81; 95% CI, 0.78~0.85), myocardial infarction (HR, 0.81; 95% CI, 0.74~0.89), and stroke (HR, 0.82; 95% CI, 0.78~0.86) compared with oGLD users. In conclusion, initiation of SGLT2i had a lower risk of cardiovascular events in people with type 2 diabetes compared with oGLDs.

Development of brazing technologies for bonding of graphite and CuCrZr joints applying for the first wall of the EAST device

  • Xianke Yang;Lei Yin;Yanwei Liu;Qianqian Lin;Chongfeng Zhong;Si Zhang;Damao Yao
    • Nuclear Engineering and Technology
    • /
    • v.56 no.11
    • /
    • pp.4487-4493
    • /
    • 2024
  • Bonding between plasma-facing materials (PFMs) and heat sinks is an important factor for the performance of plasma-facing components (PFCs) in the tokamak device; in some specific applications, graphite is adopted as the plasma-facing material and CuCrZr as the heatsink. Bonding of graphite and CuCrZr is a critical and difficult process due to the poor wettability of graphite and wide gap of material properties between graphite and CuCrZr, to which should be paid more attention. Herein, brazing processes were developed to achieve the bonding of CuCrZr and graphite, and a layer of oxygen-free copper (OFC) was placed between graphite tiles and CuCrZr heat sinks as a stress-buffer layer. Three types of brazing fillers including Ti powder with AgCu foil, AgCuTi paste and AgCuTi foil were used to achieve the bonding of CuCrZr and graphite. Samples were tested by scanning electron microscopy (SEM), energy dispersive spectrometry (EDS) and shear strength experiment; the results showed that these three types of fillers can achieve the bonding of CuCrZr and graphite. In addition, one-step brazing and multi-step brazing were both developed to achieve the bonding of graphite/OFC/CuCrZr, and the mock-ups were manufactured and endured cyclic high heat loads in the high heat flux (HHF) tests. In conclusion, the simplified one step brazing process including types of fillers, brazing temperature and brazing sequence was determined, which provides a promising premise method for the heat transfer structure design of PFCs.

A Proposal of Compact Passive Harmonic Filter for ac Motor Drive (고성능 콤팩트형 AC모터드라이브 고조파 필터 제안)

  • Park, Byung-Ju;Yoon, Dong-Chul;Oh, Jeong-Cheol;Bae, Byung-Yeol;Hwang, An-Il;Yoo, Hang-Kyu;Choi, Seok-Keun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.4
    • /
    • pp.191-199
    • /
    • 2018
  • The harmonic reduction method of ac motor drive, ACL and DCL were commonly used, but the current distortion ratio was only 35%, thus the several different types of filters as BBHF(broad band harmonic filter), HHF(hybrid harmonic filter), NHHF(new hybrid harmonic filter) have been developed to satisfy the IEEE Std. 519 harmonic limitation. However, these filters had been limited marketability due to cost and size problems. This study suggests the methods to reduce cost and size of the harmonic filter including topologies, besides we discussed simulation results of the power system with regard to the implementation and performance of the filters.

Crystall ographic and Magnetic Properties of Ultrafine $CoFe_{1.9}Bi_{0.1}O_4$ Grown by Using a Sol-Gel Method (Sol-gel법에 의한 초미세 분말 $CoFe_{1.9}Bi_{0.1}O_4$의 결정학적 및 자기적 성질 연구)

  • 김우철;김삼진;김철성;이승화
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.4
    • /
    • pp.177-183
    • /
    • 1999
  • Ultrafine $CoFe_{1.9}Bi_{0.1}O_4$ particles were fabricated by using a sol-gel method and their magnetic and structural properties were investigated with an x-ray diffractometer (XRD), a vibrating sample magnetometer (VSM), and a M$\"{o}$ssbauer spectrometer. The result of x-ray diffraction and M$\"{o}$ssbauer spectroscopy showed that the powders fired at and above 523 K had only cubic spinel structures. M$\"{o}$ssbauer spectra measurements showed that the powders annealed at 523,723 and 823 K possessed ferrimagnetic nature and paramagnetic nature due to superparamagnetism, simultaneously at room temperature and the powders annealed at and above 923 K behaved ferrimagnetically. In the case of the powder annealed at 923 K, the lattice constant was $a_0=8.398$\pm$0.005{\AA}$ and the hyperfine fields were $H_{hf}(A)=479kOe,\; H_{hf}(B)=502kOe$. The isomer shifts indicate that the iron ions are ferric at tetrahedral[A] and octahedral sites [B], respectively. The magnetization as a function of annealing temperature increased as increasing annealing temperature. The largest coercivity values were $H_C=1368\;Oe$ AT 923 K annealing temperature. In the case of the powder annealed at 1123 K, the magnetization value was $M_S=75\;emu/g$ and this value was similler to that of $CoFe_2O_4$.Fe_2O_4$.

  • PDF

Manufacturing and testing of flat-type divertor mockup with advanced materials

  • Nanyu Mou;Xiyang Zhang;Qianqian Lin;Xianke Yang;Le Han;Lei Cao;Damao Yao
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2139-2146
    • /
    • 2023
  • During reactor operation, the divertor must withstand unprecedented simultaneous high heat fluxes and high-energy neutron irradiation. The extremely severe service environment of the divertor imposes a huge challenge to the bonding quality of divertor joints, i.e., the joints must withstand thermal, mechanical and neutron loads, as well as cyclic mode of operation. In this paper, potassium-doped tungsten (KW) is selected as the plasma facing material (PFM), oxygen-free copper (OFC) as the interlayer, oxide dispersion strengthened copper (ODS-Cu) alloy as the heat sink material, and reduced activation ferritic/martensitic (RAFM) steel as the structural material. In this study, a vacuum brazing technology is proposed and optimized to bond Cu and ODS-Cu alloy with the silver-free brazing material CuSnTi. The most appropriate brazing parameters are a brazing temperature of 940 ℃ and a holding time of 15 min. High-quality bonding interfaces have been successfully obtained by vacuum brazing technology, and the average shear strength of the as-obtained KW/Cu and ODS-Cu alloy joints is ~268 MPa. And a fabrication route for manufacturing the flat-type divertor target based on brazing technology is set. For evaluating the reliability of the fabrication technologies under the reactor relevant condition, the high heat flux test at 20 MW/m2 for the as-manufactured flat-type KW/Cu/ODS-Cu/RAFM mockup is carried out by using the Electron-beam Material testing Scenario (EMS-60) with water cooling. This paper reports the improved vacuum brazing technology to connect Cu to ODS-Cu alloy and summarizes the production route, high heat flux (HHF) test, the pre and post non-destructive examination, and the surface results of the flat-type KW/Cu/ODS-Cu/RAFM mockup after the HHF test. The test results demonstrate that the mockup manufactured according to the fabrication route still have structural and interfacial integrity under cyclic high heat loads.

Prediction of Very High Critical Heat Flux for Subcooled Flow Boiling in a Vertical Round Tube (수직 원형관에서 서브쿨비등시 매우 높은 임계열유속의 예측)

  • Kwon, Young-Min;Hahn, Do-Hee
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.288-293
    • /
    • 2001
  • A critical heat flux (CHF) prediction method using an artificial neural network (ANN) was evaluated for application to the high-heat-flux (HHF) subcooled flow boiling. The developed ANN predictions were compared with the experimental database consisting of a total of 3069 CHF data points. Also, the prediction performance by the ANN was compared with those by mechanistic models and a look up table technique. The parameter ranges of the experimental data are: $0.33{\leq}D{\leq}37.5mm$, $0.002{\leq}L{\leq}4m$, $0.37{\leq}G{\leq}134Mg/m^2s$, $0.1{\leq}P{\leq}20MPa$, $50\leq{\Delta}h_{sub,in}\leq1660kJ/kg$, and $1.1{\leq}q_{CHF}\leq276MW/m^2$. $276MW/m^2$. It was found that 91.5% of the total data points were predicted within $a{\pm}20%$ error band, which showed the best prediction performance among the existing CHF prediction methods considered.

  • PDF

A Proposal of New Hybrid Passive Harmonic Filter for AC Motor Drive Line Filter Size Reduction (AC모터드라이브 라인필터의 축소화를 위한 신형 하이브리드고조파필터 제안)

  • Park, Byung-Ju;Yoon, Dong-Chul;Oh, Jeong-Cheol;Bae, Byung-Yeol;Hwang, An-il;Yoo, Hang-Kyu;Choi, Seok-Keun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • ACL and DCL are have been conventionally used for reducing harmonic current on the input side of an ACMD. The current distortion ratio ITHD using ACL and DCL is only 35% to 85%, therefore to satisfy the IEEE Std. 519 requirements, the line filters has been focused as an alternative means. Those are installed between the AC power supply and the input of the ACMD, and must meet the IEEE Std. 519, be economical and be compact. To contribute to the widespread of using these line filters, we discussed concerning its topologies, simulation results, prototype test results as well as the cost evaluations. It included not only the proposed (NHHF) new hybrid harmonic filters which have both merits of simplicity and economic but also the past (BBHF) broadband harmonic filters and (HHF) hybrid harmonic filters.

Antioxidant, Anti-Wrinkle Activity and Whitening Effect of Fermented Mixture Extracts of Angelica gigas, Paeonia Lactiflora, Rehmannia chinensis and Cnidium officinale (당귀, 작약, 지황, 천궁 혼합 발효물의 항산화, 항주름 및 미백 효과)

  • Um, Ji Na;Min, Jin Woo;Joo, Kwang Sik;Kang, Hee Cheol
    • Korean Journal of Medicinal Crop Science
    • /
    • v.25 no.3
    • /
    • pp.152-159
    • /
    • 2017
  • Background: In this study, examined the effects of an extract of a mixture of Angelica gigas, Cnidium officinale, Paeonia lactiflora, and Rehmannia glutinosa fermented by Leuconostoc mesenteroides, with enhanced value and functionality. In oriental medicine, a mixture of these herbs is called Samultang. Methods and Results: In this study, we evaluated the effects of a fermented extract of Samultang on oxidative stress, procollagen type I expression, and melanin production. Samultang was extracted with 70% ethanol, followed by inoculation with Leuconostoc mesenteroides to obtain the fermented extract. The evaluation of viability of B16F10 cells and human foreskin fibroblast (HHF) revealed that both ethanol and fermented extracts of Samultang were non-toxic. The results of 1,1-diphenyl-2-picrylhydrazyl (DPPH) test showed that the fermented extract of Samultang ($SC_{50}value=100{\mu}g/m{\ell}$) was a more effective DPPH free radical scavenger than its ethanol extract. In addition, procollagen type I expression was higher in cells treated with the fermented extract of Samultang than in cells treated with ethanol. In the non-toxic concentration range, the fermented extract of Samultang showed strong inhibitory effect on melanin production in ${\alpha}-melanocyte$ stimulatin hormone-stimulated B16F10 cells ($IC_{50}=37.9{\mu}g/m{\ell}$). Conclusions: These results suggest that the fermented extract of Samultang has considerable protential as a cosmetic ingredient owing to its antioxidant, anti-wrinkle, and whitening effects.