MV급 케이블 중간접속부의 PD 측정을 위한 UHF-센서와 HFCT-센서의 비교시험 (Comparison test for PD measuring about UHF-sensor and HFCT-sensor in cable joint-box of MV grade)

  • 신동훈;이용성;김정윤;양종석;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1511-1512
    • /
    • 2006
  • In this paper, we measured PD signals from artificial surface defects and corona discharges under laboratory circumstances like the fields using both HFCT-sensor and UHF-sensor for MV grade XLPE cable with AMP, spectrum analyzer and oscilloscope. Also, detected signals were analyzed via PRPDA system in this paper. As a result, in this case of HFCT-sensor, the amount of background noise are larger than as compared to UHF-sensor. There is needed some hardware or software or software algorithm removing background noise effectively for diagnosis the underground power transmission cable in the case of HFCT-sensor.

  • PDF

부분방전 측정용 비접촉식 HFCT 센서개발 및 특성평가에 관한 연구 (A Study on the Development and Characteristics Evaluation of Non-Contact HFCT Sensor for Partial Discharge Measurement)

  • 한상보
    • 전기전자학회논문지
    • /
    • 제28권2호
    • /
    • pp.131-135
    • /
    • 2024
  • 본 연구에서는 전력설비의 전력선에 탈부착이 용이하도록 전류계(CT) 방식의 비접촉식 부분방전 측정용 센서를 자체 개발하고, 그 특성평가 결과에 대하여 논하였다. 자체 제작한 HFCT센서의 주파수 응답특성이 20[kHz]에서 20[MHz]까지 측정 가능함을 보였으며, 정극성 방향으로 배치한 경우의 평균감도가 0.308[mV/pC], 부극성 방향으로 배치한 경우는 0.459[mV/pC]로서 부극성으로 배치한 경우가 정극성으로 배치한 경우보다 감도특성이 우수함을 보였다. 실제 부분방전 발생 및 특성측정 실험을 통하여 침전극 끝단에서 매우 미소한 코로나 기중방전이 시작되는 펄스 신호를 측정하는 것이 가능하므로 전력설비에서 발생될 수 있는 다양한 형태의 부분방전을 충분히 측정가능할 것으로 판단된다.

XLPE 전력케이블의 부분방전 측정을 위한 평면 루프 센서 설계에 관한 연구 (Korean Institute of Electrical and Electronic Materials)

  • 임광진;양상현;키아우소륀;박노준;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.27-31
    • /
    • 2008
  • In this study, The new type of loop antenna which detects the partial discharge was designed based on microstrip line technology. In diagnosis of power cable, partial discharge signal generally occurred at the frequency range lower than 100MHz because high frequency PD signals could be lost along the propagation path in the cable. The new type of loop antenna sensor has been studied by using Simulation software named CST microwave studio version 5.0. In partial discharge measuring experiments, commercial HFCT sensor was used as a reference sensor. Several experiments were made over HFCT sensor and loop antenna sensor in detection partial discharge on MV XLPE cable of 22.9kV. In this study, we have shown our loop antenna sensor can apply as a commercial HFCT sensor.

  • PDF

A Study on the Design of a Planar Loop Sensor for Partial Discharge Diagnosis of 22.9 kV XLPE Power Cables

  • Lim, Kwang-Jin;Yang, Sang-Hyun;Shin, Dong-Hoon;Park, Noh-Joon;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.559-565
    • /
    • 2008
  • This study designed a new type of loop antenna that is able to detect partial discharges based on microstrip line technology. In the diagnosis of power cables, partial discharge signals are generally produced at a frequency range less than 100MHz because high frequency PD signals are lost along a propagation path in such cables. The new type of loop antenna sensor has been studied using simulation software known as CST microwave studio version 5.0. In partial discharge measurement experiments, a commercial HFCT sensor was used as a reference sensor. Several experiments were made over HFCT and loop antenna sensors for detecting partial discharges on 22.9kV MV XLPE cable. In this study, we showed the loop antenna designed in this study that can be applied as a commercial HFCT sensor.

Prototype 패치 안테나를 이용한 MV급 전력케이블의 부분방전 측정 연구 (New Method of PD measuring on MV XLPE Cable by Using Prototype Patch Antenna)

  • 키아우소 륀;신동훈;임광진;공태식;김희동;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.146-148
    • /
    • 2007
  • We studied the partial discharge detecting by sensing electromagnetic wave emitted from the partial discharge source in the MV XLPE cable with the new type of patch antenna sensor. In this study, we design new kind of Patch antenna and make many experiments compare with the existing HFCT sensor on MV XLPE cable in the laboratory. According to our experimental results our new sensor can defect pure PD and wider bandwidth 20MHz to 70MHz than HFCT and can easily localized manually on the cable.

  • PDF

부분방정 측정에서 센서 및 펄스 분석 알고리즘에 따른 노이즈 제거 연구 (A Study of the Noise Discrimination by use of Different Sensors and Pulse Analysis Algorithms in Measuring Partial Discharge)

  • 김지홍;구자윤;김정태
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권4호
    • /
    • pp.183-188
    • /
    • 2006
  • Abstract - In order to investigate the possibility of separating PD(partial discharge) and noises through the pulse analysis by use of a HFCT, pulse shapes measured by a resistive sensor and a HFCT were analyzed and adequate PA(pulse analysis) algorithms were studied. For the purpose, the HFPD detection and PA system has been developed. Also void discharges and air corona were adopted as the artificial defect and noises, respectively. As a result, it is possible to separate partial discharges and noises through the PA method using the $100kHz{\sim}20MHz$ frequency range HFCT. It is expected to apply the developed system to on-site PD measurements for the electric equipments.

The Design and Experiment of a Planar Patch Sensor for Partial Discharge Diagnostics in 6.6 kV Rotating Machine Stator Windings

  • Yang, Sang-Hyun;Park, Noh-Joon;Park, Dae-Hee;Kim, Hee-Dong;Lim, Kwang-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권5호
    • /
    • pp.173-176
    • /
    • 2009
  • In the stator windings of a 6.6 kV rotating machine, internal discharges, slot discharges, and surface discharges are mainly caused by internal voids and insulation degradation. If a partial discharge(PD) occurs in an inner-part of the stator windings, it will cause electromagnetic pulses with wide frequency ranges. Discharge sparks and electromagnetic pulses generated from a discharge source, can be detected using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, a planar patch sensor was designed and fabricated using a CST-MWS simulation, and PD signals from an artificially defected stator winding were also measured by the sensor proposed in this study. Furthermore, an HFCT was used as a reference sensor and compared with the proposed new planar patch sensor. In the results of the experiment, the planar patch sensor showed a similar performance to the HFCT sensor.

회전기 고정자권선의 부분방전 진단용 평면 패치센서의 설계 및 실험

  • 양상현;박노준;김충식;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.228-228
    • /
    • 2009
  • In stator windings of a 6.6kV rotating machine, internal discharge, corona discharge, and surface discharge are mainly caused by internal voids and insulation degradation. In the case of the discharge spark and electromagnetic pulse generated from a discharge source, we can detect it using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, we designed and fabricated a planar patch sensor using a CST-MWS simulation, and PD signals from artificial defected stator windings were also measured by the sensor proposed in this study. Furthermore, In the results of the experiment, it showed similar performance to the HFCT sensor.

  • PDF

HFCT를 활용한 고전압직류송전 케이블 부분방전 위치추정 (Detection and localization of partial discharge in high-voltage direct current cables using a high-frequency current transformer)

  • 홍선민;손우영;천혜원;강대경;박종후
    • 센서학회지
    • /
    • 제30권2호
    • /
    • pp.105-108
    • /
    • 2021
  • Detection and localization of partial discharge are considered critical techniques for estimating the lifetimes of power cables. High-frequency current transformers (HFCTs) are commonly used for the detection of partial discharge in high-voltage alternating current (HVAC) power cables; however, their applicability is compromised by the limitations of the installation locations. HFCTs are typically installed in cable terminals or insulation joint boxes because HVACs induce strong time-varying magnetic fields around the cables, saturating the ferromagnetic materials in the HFCTs. Therefore, partial discharges near the installation locations can be detected. In this study, the feasibility of partial discharge detection using a HFCT was investigated for high-voltage direct current (HVDC) cables. We demonstrated that the HFCT could be installed at any location in the HVDC power cable to monitor partial discharge along the entire cable length. Furthermore, we showed that the HFCT could detect the location of partial discharge with high accuracy.

prototype 패치 안테나를 이용한 고압 회전기의 부분방전 측정 연구 (PD Diagnosis on High Voltage Rotating by Using New Prototype Patch Antenna Sensor)

  • 키아우소 륀;신동훈;임광진;공태식;김회동;박노준;박대회
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.169-171
    • /
    • 2007
  • We studied the partial discharge detecting by sensing electromagnetic wave emitted from the partial discharge source in the HV Rotating Machine with the new prototype patch antenna sensor. In this study, we design new type of patch antenna based on microstrip technology and make many experiments of elaine testing compare with the existing HFCT and EM probe on stator winding of HV generator in the laboratory. This paper will mention comparison of experimental results based on the three kinds of sensors.

  • PDF