• Title/Summary/Keyword: HFC-22

Search Result 55, Processing Time 0.022 seconds

Performance of HFC32/HFC152a Mixture for Water-source Heat Pumps (수열원 히트펌프 용 HFC32/HFC152a 혼합냉매의 성능평가)

  • Kang, Dong-Gyu;Kim, Wook-Jin;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.391-400
    • /
    • 2012
  • In this study, performance of HFC32/HFC152a mixture is measured in the composition range of 20 to 50% R32 with an interval of 10% for the comparison with the conventional HCFC22 in water-source heat pumps. Tests are carried out under the same capacity in a heat pump bench tester equipped with a variable speed compressor at the evaporation and condensation temperatures of 7/$45^{\circ}C$ and -7/$41^{\circ}C$ for summer and winter conditions, respectively. Test results show that the compressor power of the HFC32/HFC152a mixture is 13.7% lower than that of HCFC22 while the coefficient of performance(COP) the HFC32/HFC152a mixture is 15.8% higher than that of HCFC22. Hence, from the view point of energy efficiency, the HFC32/HFC152a mixture is excellent as compared to HCFC22. Compressor discharge temperatures of HFC32/HFC152a mixture are increased up to $15.4^{\circ}C$ as compared to that of HCFC22. The amount of charge for HFC32/HFC152 mixture decrease up to 27% as compared to that of HCFC22. Overall, HFC32/ HFC152a mixture is an excellent long term candidate to replace HCFC22 in water-source heat pumps.

Flame Extinguishing Concentrations of Mixed Gaseous Agents (가스계 혼합소화약제의 불꽃소화농도)

  • 김재덕;임종성;이윤우;이윤용
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.34-40
    • /
    • 2001
  • Fire extinguishing efficiency of mixed gaseous agents were investigated by the cup-burner test and predicting by the model of flame extinguishing concentration. The binary mixed agents that tested were carbon dioxide/HFC-23, carbon dioxide/HCFC-22, carbon dioxide/HFC-227ea, carbon dioxide/HFC-125, carbon dioxide/FIC-13I1, Hexafluoropropylene/HFC-23 and ternary mixed agents were carbon dioxide/HFC-23/HFC-l34a, carbon dioxide/HFC-23/HFC-227ea, carbon dioxide/HFC-23/HFC-125. A model which contains the flame extinguishing concentration and composition of pure components predicted the flame extinguishing concentration of mixture well. This model was superior when each component of the mixture exhibit physical fire extinguishing performance.

  • PDF

Computer Simulation of a Super-Heat Pump System (고효율 수퍼히트펌프에 관한 전산 해석)

  • Kim, H.J.;Jung, D.S.;Kim, C.B.;Ha, K.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.234-248
    • /
    • 1995
  • A super-heat pump system composed of a suction line heat exchanger, low and high stage economizers, and a screw compressor is simulated to examine the energy performance and design options. CFC12, HCFC22, HFC134a, HCFC22/HCFC142b, HFC32/HFC134a, and HFC125/HFC134a are used as working fluids for comparison. The results indicate that the proposed system charged with appropriate mixtures is up to 33.4% more energy efficient than the normal system with CFC12. The performance of the super-heat pump system charged with mixtures was influenced by such factors as the temperature matching, heat source temperature difference, low stage economizer, and high stage economizer. The fluids with a larger liquid specific heat such as HFC134a would have more benefits when a suction line heat exchanger is installed. 40%HCFC22/60%HCFC142b mixture seems to be a good candidate to replace CFC12. On the other hand, 25%HFC32/75% HFC134a would be a good long term candidate to replace HCFC22.

  • PDF

Measurement of Mutual Solubility of High-pressure Gaseous Fire Extinguishing Agents(HFCs) and Nitrogen (고압가스계 소화약제(HFCs계열)와 질소의 상호용해도 측정)

  • 임종성;박지영;이병권;김재덕;이윤용
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.26-31
    • /
    • 2002
  • Bromotrifluoromethane(halon-1301) and bromochlorodifluoromethane(halon-1211) have been widely used as a clean fire extinguishing agents due to their outstanding properties. However, production and use of halon are currently being phased out under an international agreements Montreal Protocol because of global environmental concerns and HFCs have been considered as promising alter-natives for the replacement of halon since their ozone depletion potentials are low. The vapor-liquid equilibrium data are required as important basic information in evaluating the solubility of clean fire extinguishing agents and determining their optimal compositions. In this work, we chose HFCs such as HFC-22 HFC-125, and HFC-l34a for gaseous fire extinguishing agents and nitrogen as a pressurization gas for a proper jet velocity of these agents. Phase equilibria for binary mixtures of nitrogen/HFC-22, nitrogen/HFC-125, and nitrogen/HFC-l34a were measured in the temperature range from 283.15K to 303.15K. For equilibrium measurement, we used a circulation type apparatus in which both vapor and liquid phases were continuously recirculated. The experimental data were relatively well correlated with the Peng-Robinson equation of state with Wong-Sandier mixing rules.

Application of Procedures to Calculate Thermodynamic Properties of Carbon Dioxide, HFC-l34a and HCFC-22 (이산화탄소, HFC-l34a, HCFC-22의 열역학적 상태량 계산 절차의 응용)

  • 박형준;박경근
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.389-396
    • /
    • 2003
  • Systematic methods to calculate thermodynamic properties of carbon dioxide, HFC-l34a and HCFC-22 are presented. First, application of a basic method to identify the saturation state with given temperature or pressure is attempted and the feasibility of auxiliary equations is tested. Next, detailed procedures are suggested to tell a phase when temperature/pressure and another property are specified. Finally Newton-Raphson method is applied to calculate unknown thermodynamic properties fixing the state with the two independent properties specified. The procedures described here are utilized to develop a computer program, which is used to find the relation between temperature and pressure with maximum isobaric heat capacity for super-critical carbon dioxide.

Performance of HFC152a, HFC134a and HC290 Mixtures as Alternative Refrigerants for HFC134a (HFC152a, HFC134a, 프로판을 포함한 자동차용 대체/보충 냉매의 성능)

  • Kang, Nam-Koo;Bae, Guen-Hwan;Park, Ki-Jung;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.383-391
    • /
    • 2010
  • In this study, HFC152a, HFC134a/HFC152a and HC290/HFC134a/HFC152a mixtures are studied for the supplementary and alternative refrigerants for HFC134a used in automobile air-conditioners. Due to the high global warming potential of HFC134a, it has to be phased out in the long run. Thermodynamic performance of these refrigerants are measured in a bench tester of 3.5 kW capacity with an open type compressor under both summer and winter conditions. Test results show that the coefficient of performance (COP) and capacity of pure HFC152a and HFC134a/HFC152a mixture are 9.1~12% and 7% higher than those of HFC134a. As for the HC290/HFC134a/HFC152a, the COP is up to 9.5% higher than that of HFC134a with 1~2% of HC290 while that is up to 6.1% lower than that of HFC134a with 5% HC290. The capacity of the ternary mixture, however, is 8.6% higher than that of HFC134a at all compositions tested. The compressor discharge temperatures of all refrigerants tested are $6{\sim}10^{\circ}C$ higher than that of HFC134a. For all refrigerants, the amount of charge is reduced up to 32% due to the decrease in liquid density. Overall, these refrigerants provide good performance with reasonable energy savings with less environmental problem and thus can be used as long term alternatives for automobile air-conditioners.

Phase Behavior of Poly(methylmethacrylate) (PMMA) in Varions Solvents at High Pressure (고압상태의 다양한 용매 내에서 Poly(methylmethacrylate) (PMMA)의 상거동)

  • Kim, Je-Il;Yoo, Ki-Pung;Lim, Jong-Sung
    • Clean Technology
    • /
    • v.13 no.1 s.36
    • /
    • pp.28-33
    • /
    • 2007
  • We measured cloud points of Poly(methylmethacrylate) (PMMA) in various solvents using the high-pressure variable volume view cell apparatus. The solvents used for dissolving PMMA were chlorodifluoromethane (HCFC-22), dimethylether (DME), 1,1,1-trifluoroethane (HFC-143a), 1,1-difluoroethane (HFC-152a) and 1,1,1,2-tetrafluoroethane (HFC-134a), and the effect of $CO_2$ concentration on the phase behavior of $PMMA+HCFC-22+CO_2$ system and $PMMA+DME+CO_2$ system was observed. PMMA was dissolved well in HCFC-22 from about 340 K, 5MPa and in DME from about 300 K, 28MPa. However, PMMA was not dissolved at all up to 423.15 K, 160MPa in the other fluorine compound such as HFC-l43a, HFC-152a and HFC-134a. PMMA+HCFC-22, $PMMA+HCFC-22+CO_2$ and PMMA+DME systems exhibit the lower critical solution temperature (LCST) behavior, however, $PMMA+DME+CO_2$ system exhibits the upper critical solution temperature (UCST) behavior. In the $CO_2$ mixture, the cloud point pressure of PMMA was increased dramatically proportional to the amount of $CO_2$ added, and from this result, it was known that $CO_2$ could be used as an antisolvent for fabricating PMMA nano-particles. And the cloud point of PMMA could be controlled by changing the concentration of $CO_2$.

  • PDF

Effects of Chicken Treated with Hwangki-Beni Koji Sauces on Body Weight, Serum and Hepatic Lipid Profiles of Rats Fed High Fat and High Cholesterol Diets (황기홍국소스를 처리한 계육이 고지방 및 고콜레스테롤 식이 흰쥐의 체중과 혈청 및 간 조직의 지질 함량에 미치는 영향)

  • Kim, Jae-Won;Kim, Soon-Dong;Youn, Kwang-Sup
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.9
    • /
    • pp.1270-1278
    • /
    • 2010
  • Dietary effects of chicken treated with Hwangki-Beni Koji sauces (HBS) on serum and hepatic lipid profiles in rats fed high a fat and high cholesterol diet were investigated. Experimental plots (5 rats per each group) were divided into normal control diet group (NC), high fat and high cholesterol diet group (HFC), HFC plus 15% base sauce treated chicken supplemented diet group (HFC-BS), HFC plus 15% HBS-treated chicken supplemented diet group (HFC-HBS), and fed for 5 weeks. Feed intakes in HFC-HBS group were higher than those of HFC and HFC-BS groups, whereas body weight gain and feed efficiency ratio of the HFC-HBS group were lower than those of the HFC and HFC-BS groups. Serum alanine aminotransferase and aspartate aminotransferase activities of HFC-HBS group were significantly lower than those of HFC and HFC-BS groups. Level of serum triglyceride, total cholesterol and LDL-cholesterol in HFC-HBS group were 34.06%, 6.28% and 31.00% lower than those of HFC-BS group, respectively, whereas HDL-cholesterol level and atherogenic index in HFC-HBS group were 1.72-fold higher and 2.52-fold lower, respectively, than those of HFC-BS group. Level of hepatic total lipid, triglyceride and total cholesterol in HFC-HBS group were 9.53%, 5.25% and 22.20% lower than those of HFC-BS group, respectively. In the morphological results of liver, the hepatocytes of central vein lesion and intact hepatic cell plate are preserved well from steatosis in HFC-HBS group, whereas the hepatocytes in HFC and HFC-BS groups are distended by accumulation of multiple fat droplets, and sinusoids are occluded. In the above results, we expected that chicken treated with Hwangki-Beni Koji sauce may have functionalities of anti-obesity, anti-cholesterol and also, lowering anti-atherogenic index in high fat and high cholesterol diets.

Emission Characteristics of HFC-23 (CHF3)/HCFC-22 (CHClF2) between Different Air Masses in Northeastern Asia (동북아시아 지역에서의 공기괴별 HFC-23/HCFC-22의 배출특성)

  • Li, Shanlan;Kim, Joo-Il;Kim, Kyung-Ryul;Muhle, Jens
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.490-498
    • /
    • 2010
  • HCFC-22 (chlorodifluoromethane, $CHClF_2$), one of the major components in various refrigeration, is emitted mostly from developing countries, as its consumption is not limited until 2013 by the Montreal Protocol. In addition, HFC-23 (trifluoromethane, $CHF_3$), a by-product in the manufacture of HCFC-22, is also a powerful greenhouse gas. Here, we discuss the regional emission characteristics of these compounds based on high-frequency in-situ measurements using the "Medusa" GC-MS system. HCFC-22 and HFC-23 baseline concentrations measured at Gosan (Jeju Island, Korea) from November 2007 to December 2008 increased by 1.8 ppt/yr and 0.6 ppt/yr, respectively. Pollution events of these compounds were observed, very frequently (e.g., ~2~3 times) at Gosan than baseline levels. All the measurement data were divided into four groups by simultaneously considering the ratio (HFC-23/HCFC-22) and concentration (HCFC-22) at Trinidad Head (TH, California, USA). The residence time of trajectories were then analyzed in each of the four groups. The results exhibited the existence of a strong correlation with air mass origin for each group: 1) Air masses originating from Siberia in the north and from the Pacific in the south had ratios of 0.08~0.12 and concentrations of 196.9~254.3 ppt which is highly comparable to background air at TH. 2) Air masses passing over the Southern China exhibited similar ratios but higher HCFC-22 concentrations. 3) Air masses passing over the Northern China had ratios of 0.12~0.21. 4) Air masses passing over Korea and/or Japan had ratios of 0.01~0.08. Our results suggest that the HFC-23/HCFC-22 ratio can be used as a good indicator for the assessment of the pollution with Chinese origin. We also confirmed differences in air masses traveling over Northern and Southern China, most likely due to differences in air mass travelling speed over these regions before arriving at Gosan. This signature may be treated as one of the critical components in identifying the emission sources from different parts of China.

Flow Characteristics of Refrigerant Mixtures with R32 in a Capillary Tube (R32를 포함한 R22 대체 혼합냉매의 모세관 유동 특성)

  • Chang, S.D.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.177-186
    • /
    • 1996
  • The characteristics of the flow of pure HFC refrigerants(R32, R125, and R134a) and their mixtures through capillary tubes were investigated experimentally. Two capillary tubes with 1.2mm and 1.6mm inner diameter and 1.5m length were adopted as test sections. Mass flow rates and temperatures and pressures were measured for several condensing temperatures and degrees of subcooling at capillary tube inlet. The effects of the condensing temperature, inner diameter of capillary tube, and subcooling on the mass flow rate of refrigerants were discussed, and the mass flow rates of HFC refrigerants were compared with that of R22. The pressure and temperature distributions along the capillary tube compared with that of R22. The pressure and temperature distributions along the capillary tube show that there is a metastable equilibrium state in the flow through the tube. Underpressure for vaporization increases as refrigerant mass flux increases and inlet subcooling decreases. Empirical correlation was suggested to predict underpressure for vaporization of the HFC refrigerants.

  • PDF