• 제목/요약/키워드: HERO 642

검색결과 13건 처리시간 0.021초

Apical root canal cleaning after preparation with endodontic instruments: a randomized trial in vivo analysis

  • Fornari, Volmir Joao;Hartmann, Mateus Silveira Martins;Vanni, Jose Roberto;Rodriguez, Rubens;Langaro, Marina Canali;Pelepenko, Lauter Eston;Zaia, Alexandre Augusto
    • Restorative Dentistry and Endodontics
    • /
    • 제45권3호
    • /
    • pp.38.1-38.10
    • /
    • 2020
  • Objectives: This study aimed to evaluate vital pulp tissue removal from different endodontic instrumentation systems from root canal apical third in vivo. Materials and Methods: Thirty mandibular molars were selected and randomly divided into 2 test groups and one control group. Inclusion criteria were a positive response to cold sensibility test, curvature angle between 10 and 20 degrees, and curvature radius lower than 10 mm. Root canals prepared with Hero 642 system (size 45/0.02) (n = 10) and Reciproc R40 (size 40/0.06) (n = 10) and control (n = 10) without instrumentation. Canals were irrigated only with saline solution during root canal preparation. The apical third was evaluated considering the touched/untouched perimeter and area to evaluate the efficacy of root canal wall debridement. Statistical analysis used t-test for comparisons. Results: Untouched root canal at cross-section perimeter, the Hero 642 system showed 41.44% ± 5.62% and Reciproc R40 58.67% ± 12.39% without contact with instruments. Regarding the untouched area, Hero 642 system showed 22.78% ± 6.42% and Reciproc R40 34.35% ± 8.52%. Neither instrument achieved complete cross-sectional root canal debridement. Hero 642 system rotary taper 0.02 instruments achieved significant greater wall contact perimeter and area compared to reciprocate the Reciproc R40 taper 0.06 instrument. Conclusions: Hero 642 achieved higher wall contact perimeter and area but, regardless of instrument size and taper, vital pulp during in vivo instrumentation is not entirely removed.

Shaping ability of Ni-Ti Rotary files in combination with GT Rotary Ni-Ti file

  • Shin, D.R.;Park, S.J.;Choi, G.W.
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.573.2-573
    • /
    • 2001
  • The objective of this study was to compare the apical shaping ability of the ProFile .04 taper, Lightspeed and HERO 642 rotary instruments and to assess the combined effect of GT Rotary files to Lightspeed and HERO 642 instruments. Forty-eight resin simulated root canal blocks divided into 4 groups with 12 canals. Forty-eight blocks were prepared by one operator with GT Rotary files using a high torque handpiece at 300 rpm. Thirty-six blocks in the three experimental groups were prepared with ProFile 04 taper file, Lightspeed file, HERO 642 file.(omitted)

  • PDF

차아염소산나트륨 용액과 고압증기멸균이 근관치료용 니켈-타이타늄 파일의 주기적 피로 파절에 미치는 영향 (CYCLIC FATIGUE OF THE SODIUM HYPOCHLORITE TREATED AND /OR STEAM AUTOCLAVED NICKEL-TITANIUM ENDODONTIC FILES)

  • 조혜영;정일영;이찬영;김의성
    • Restorative Dentistry and Endodontics
    • /
    • 제33권1호
    • /
    • pp.54-65
    • /
    • 2008
  • 본 연구에서는 차아염소산나트륨 용액 및 고압증기멸균이 근관 치료용 Ni-Ti 파일의 주기적 피로 파절에 미치는 영향을 알아보고자 하였다. 파일 첨단 크기가 #30이고 .06 taper를 가지는 Hero $642^{(R)}$$K3^{(R)}$파일 70개를 10개씩 7개의 군으로 나누었으며, 6% 차아염소산나트륨 용액에 15분 (N15군), 30분 (N30군), 고압증기멸균은 $121\;^{\circ}C$의 온도, 0.12 MPa의 압력에서 20분간 시행하는 것을 일 회로 하여 5회 (H5군), 10회 (H10), 고압증기멸균 5회 후 차아염소산나트륨 용액 15분(H5N15), 고압증기멸균 10회 후 차아염소산나트륨 용액 30분 (H10N30) 처리 후 주기적 피로 파절 실험을 수행하여 파일이 파절될 때까지의 시간을 초 단위로 측정하였다. 대조군은 전처리를 하지 않고 주기적 피로 파절을 시행하였다. 95%의 신뢰도로 one-way analysis of varience를 이용하여 통계 처리하였으며, 다중 비교는 Tukey방법으로 분석하였다. 파일의 표면을 주사전자현미경으로 관찰하였다. 주기적 피로 파절에 소요된 시간은 Hero $642^{(R)}$는 각 군별로 유의할 만한 차이가 없었으며, $K3^{(R)}$는 N15, N30, H5N15군에서 대조군에 비해 짧은 시간이 소요된 것으로 나타났다 (p < 0.05). 주사전자 현미경에서 관찰했을 때 Hero $642^{(R)}$$K3^{(R)}$모두 N15, N30군에서 파일의 표면과 날이 부식이 되어 대조군에서 관찰된 일정 방향으로 배열된 정형화된 예리한 빗살무의가 부분적으로 파괴된 형태가 관찰되었으며, N15군에 비해 N30군에서 파일의 형태가 파괴된 양상이 뚜렷했으며, Hero $642^{(R)}$보다 $K3^{(R)}$가 심하게 부식된 양상이었다. H5군과 H10군에서는 $K3^{(R)}$ 파일은 날 부분이 무디어진 양상을 보였고, Hero $642^{(R)}$는 형태 파괴가 뚜렷하지 않았으나 H10군에서 표면의 빗살무늬가 약간 무디어진 양상을 보였다. H5N15군과 H10N30군에서는 그다지 뚜렷한 형태변화는 없었다. 본 연구 결과 $K3^{(R)}$파일을 사용 시에는 가능한 한 차아염소산나트륨에 적은 시간 노출시키는 것이 파일의 부식으로 인한 형태의 손상을 방지할 수 있고, 주기적 피로 파절에 걸리는 시간도 감소시킬 수 있을 것이다.

GT Rotary Ni-Ti file과 함께 사용한 구동용 Ni-Ti file의 근관 성형력 비교에 대한 연구 (Shaping ability of Ni-Ti Rotary files in combination with GT Rotary Ni-Ti file)

  • 신동렬;박상진;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.196-206
    • /
    • 2002
  • 본 연구는 근관의 치관부는 GT Rotary file을 이용하여 성형하고, 근단부는 K-Flexofile, ProFile .04, Lightspeed, HERO642 file로 성형하여 근관용 file의 근관성형력을 비교하는 것이다. 실험 표본으로는 resin simulated root canal blocks(Dentsply, Swiss)를 이용하였고 4개의 군으로 분류하여 실험을 실시하였다. 모든 resin block을 GT Rotary file(Dentsply, Swiss)을 이용하여 치관부를 형성한 후 근단부는 K-Flexofile(Dentsply, Swiss), ProFile .04 taper file(Denstply. Swiss), Lightspeed file(Lightspeed Tech., USA), HERO642 file(Micromega, France)로 ISO size #35까지 형성하였다. 성형 후 preparation time과 instrument failure를 측정하였고 최종 사용한 file을 resin block 내에 재위치시켜 working length의 변화량을 0.5mm 단위로 측정하였다. Resin debris에 의한 canal blockage를 조사하였으며, 근관 내의 인상을 채득하여 canal form을 평가하였다. 성형 전과 성형 후의 사진을 촬영하고 computer software를 이용하여 중첩시킨 후 canal aberration, canal transportation을 평가하여 다음과 같은 결과를 얻었다. 1. Preparation time, working length의 변화량, canal blockage, canal aberration, canal transportation에 있어서 Ni-Ti file이 stainless steel file에 비하여 우수하였다(p<0.05). 반면에 근관성형력에 있어서 canal form과 canal transportation을 제외하고는 세 Ni-Ti file 사이에는 유의차가 없었다(p>0.05). 2. Canal form 중 taper에 있어서 Lightspeed는 적절하지 못한 taper를 보여주었다(p<0.05). 3. Canal transportation에 있어서 Lightspeed 군과 HER0642 군이 K-Flexofile 군과 ProFile .04 군에 비해 적게 나타났고(p<0.05), 특히 만곡의 끝 부분에서는 Lightspeed 군이 가장 적게 나타났다(p<0.05). 이상과 같은 연구결과로 보아 부적절한 taper를 지니고 있던 Lightspeed fie과 HERO642 file 중 HERO642 file은 GT Rotary file과 함께 사용함으로써 적절한 taper로 형성할 수 있었으나 Lightspeed file은 효과적이지 못하였으므로 적절한 taper를 형성하기 위한 file이 치근의 중간부를 형성하기 위해 필요함이 확인되었다.

수종의 엔진구동형 Nickel-Titanium file을 이용한 근관형성 방법이 근관만곡도 유지능력에 미치는 영향 (EFFECT OF VARIOUS CANAL PREPARATION TECHNIQUES USING ROTARY NICKEL-TITANIUM FILES ON THE MAINTENANCE OF CANAL CURVATURE)

  • 이철환;조경모;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제28권1호
    • /
    • pp.41-49
    • /
    • 2003
  • There are increasing usage of Nickel-Titanium rotary files in modern clinical endodontic treatment because it is effective and faster than hand filing due to reduced step. This study was conducted to evaluate the effect of canal preparations using 3 different rotary Nickel-Titanium files that has different cross sectional shape and taper on the maintenance of canal curvature. Simulated resin block were instrumented with Profile(Dentsply, USA), GT rotary files(Dentsply, USA), Hero 642(Micro-Mega France), and Pro-Taper(Dentsply, USA). The image of Pre-instrumentation and Post-instrumentation were acquired using digital camera and overspreaded in the computer. Then the total differences of canal diameter, deviation at the outer portion of curvature, deviation at the inner portion of curvature, movement of center of the canal and the centering ratio at the pre-determined level from the apex were measured. Results were statistically analyzed by means of ANOVA, followed by Scheffe test at a significance level of 0.05. The results were as follows; 1. Deviation at the outer portion of curvature, deviation at the inner portion of curvature were showed largest in Pro-Taper so also did in the total differences of canal diameter(p<0.05). 2. All the groups showed movements of center Profile combined with GT rotary files and Hero 642 has no difference but Pro-Taper showed the most deviation(p<0.05). 3. At the 1, 2, 3mm level from the apex movements of center directed toward the outer portion of curvature, but in 4, 5 mm level directed toward the inner portion of curvature(p<0.05). As a results of this study, it could be concluded that combined use of other Nickel-Titanium rotary files is strongly recommended when use Pro-Taper file because it could be remove too much canal structure and also made more deviation of canal curvature than others.

다양한 엔진 구동형 파일의 근관 성형 능력 비교 (SHAPING ABILITY OF NICKEL-TITANIUMROTARY FILES)

  • 박완기;이희주;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제29권1호
    • /
    • pp.44-50
    • /
    • 2004
  • This study compared the shaping ability of nickel-titanium rotary files with different rake angle and radial land. The nickel-titanium files used in this study were Profile(Dentsply, Maillefer, Ballaigues, Switzerland), Hero 642(Micromega, Besancon, France) and K3 (SybronEndo, Glendora, Ca, USA) file. Resin blocks substituted for root canals. 36 resin blocks were divided into 3 groups with 12 canals each The time for canal preparation was recorded. The images of pre- and postoperative resin canal were scanned and those were superimposed Amounts of canal deviation, total canal widths, inner canal widths, and outer canal widths were measured at apical 1, 2 ,3, 4, 5, 6, and 7mm levels. The amount of canal deviation was the smallest in Profile group , and the time far canal preparation was the shortest in Hero 642 group. K3 group resulted in competent characteristics in both measurements. Positive rake angle seemed to result in fast shaping of root canal and radial land guide the instrument in center of the canals and around curvatures. Radial land also tended to reduce the sense of screwing into the root canal. The proper selection of the nickel-titanium fie based on the knowledge about file design is needed for the safer, simpler and faster root canal therapy.

근관의 치경부 조기 확대가 치근단 잔사 정출에 미치는 효과 (THE EFFECT OF EARLY CORONAL FLARING ABOUT APICAL EXTRUSION OF DEBRIS)

  • 김민경;미정범;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제29권2호
    • /
    • pp.147-152
    • /
    • 2004
  • The purpose of this study was to investigate the quantity of debris which was extruded apically after canal instrumentation using different types of enlarging instrument in endodontic resin models. Five groups of 9 endodontic resin models were instrumented using each different technique : hand instrumentation without early coronal flaring. hand instrumentation after early coronal flaring. and three nickel-titanium engine-driven instrumentations (Hero 642, Protaper, $K^$). Debris extruded from apical foramen during instrumentation was collected on preweighed CBC bottle, desiccated and weighted using electronic balance. The results were analyzed using Kruskal-wallis test and Mann-Whitney U rank sum test at a significance level of 0.05. The results were as follows: 1. All of instrumentation techniques produced apically extruded debris. 2. Group without early coronal flaring extruded significant more debris than groups with early coronal flaring. 3. There was no significant difference among early coronal flaring groups. The early coronal flaring is very important to reduce the amount of debris extruded apically.

수종의 NiTi 전동 파일 단면 형태 비교 및 pecking motion의 사용방법이 피로 파절에 미치는 영향 (COMPARATIVE STUDY ON MORPHOLOGY OF CROSS-SECTION AND CYCLIC FATIGUE TEST WITH DIFFERENT ROTARY NITI FILES AND HANDLING METHODS)

  • 김재관;금기연;김의성
    • Restorative Dentistry and Endodontics
    • /
    • 제31권2호
    • /
    • pp.96-102
    • /
    • 2006
  • 본 연구는 현재 시판중인 $Profile^{(R)},\;ProTaper^{(R)},\;K3^{(R)},\;Hero\;642^{(R)},\;Hero\;Shaper^{(R)}$를 단면을 비교하고 이들 5가지 NiTi 파일과 사용방법에 따른 피로 파절 소요 시간을 비교하고자 시행되었다. 각 NiTi전동파일의 치근단 1/3을 temporary resin에 매몰시키고 다이아몬드 표면처리된 버로 잘라내어, 초음파를 이용하여 세척 후, 주사전자현미경으로 단면을 관찰하였다. 주기적인 피로 실험을 수행하기 위해, 회전속도, pecking 거리를 자동적으로 조절할 수 있는 장치를 제작하고 파일을 만곡된 상태를 재현하기 위하여 15도 경사진 금속 토막에 위치시키고 분당 300회전의 속도로 회전시켜 파일이 파절될 때까지의 시간을 측정하였다. 사용방법에 따른 실험군은 동적군과 정적군으로 나누고 pecking 거리는 3 mm, 6 mm로 하였다. 실험결과 동적군 보다는 정적군의 피로파절 소요시간이 통계학적으로 유의차 있게 짧았으며 3 mm, 6 mm의 pecking distance에 따른 영향은 나타나지 않았다. 결론적으로 NiTi전동파일은 pecking motion으로 사용하는 것이 피로파절을 줄이는데 도움이 될 것으로 사료된다.

A study on the quantity of apical extrusion of debris according to early coronal flaring

  • Kim, Min-Kyung;Hwang, Ho-Keel
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.580-580
    • /
    • 2003
  • I. Objectives This study investigated the quantity of debris which was extruded apically after canal instrumentation using different types of enlarging instrument in endodontic resin models. II. Materials and Methods Five groups of 9 endodontic resin model were instrumented using each different technique:hand instrumentation without early coronal flaring, hand instrumentation after early coronal flaring, and three nickel-titanium engine-driven instrumentations(Hero 642, Protaper, K3) after early coronal flaring.(omitted)

  • PDF

수종의 엔진구동형 니켈-타이타늄 파일에 의한 급한 만곡의 근관 성형시 근관형태 변화에 대한 비교연구 (THE CHANGE OF CANAL CONFIGURATION AFTER INSTRUMENTATION BY SEVERAL NICKEL-TITANIUM FILES IN THE SIMULATED CANAL WITH ABRUPT CURVATURE)

  • 임중장;김동준;황윤찬;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제30권4호
    • /
    • pp.303-311
    • /
    • 2005
  • 본 연구는 치근첨부위의 급한 만곡을 가진 근관에서 엔진구동형 니켈-타이타늄기구를 이용해 근관 성형시 근관형태 변화에 대한 비교 연구를 함으로써 어떤 기구가 근관의 본래 형태를 잘 유지하는가를 구명하기 위하여 시행되었다. $\sharp$15 finger spreader를 이용해 만곡된 근관의 주형을 형성하고 epoxy resin으로 모형 근관을 갖는 레진 블록 96개를 제작하였다. 모형 근관은 만곡의 반경이 1.5mm, 3.0mm, 4.0mm 및 6.0mm를 가지며, 근관의 만곡도는 90도로 제작하였다. 엔진구동형 니켈-타이탸늄 파일로 ProFile, ProTaper, Hero 642 그리고 $K^3$를 사용하였으며 크라운다운법을 이용하여 제조회사의 지시에 따라 300rpm으로 근관을 성형하였다 시술 전$\cdot$후 사진을 디지털 카메라를 이용하여 촬영한 후, 이미지분석기를 이용하여 근관의 변화량을 측정하였다. 근관의 만곡을 따라서 치근첨으로부터 1mm간격으로 계측점을 총 9부분을 설정하여 원래의 근관형태가 유지되는 정도를 측정하였다 각 계측점 에서 근관의 중심축의 변위량, 근관의 폭의 변화량을 측정하였다. 계측점에서 각 기구들간의 유의성은 Kruskal-Wallis 분석법을 이용하였고 기구간에 검정은 Mann-Whitney U-test분석법을 이용한 결과 급격히 만곡된 근관 성형시에 반경 1.5mm의 만곡에서는 엔진구동형 니켈-타이타늄 파일을 사용시 주의를 요하며, 반경 3.0mm 이상의 만곡에서는 다른 엔진구동형 니켈-타이타늄 파일보다는 ProFile의 사용이 권고된다.