• 제목/요약/키워드: HEAT2

검색결과 17,187건 처리시간 0.038초

이중 열원 히트펌프 시스템의 난방 성능과 운전 특성 (Heating Performance of Heat Pump System Using Dual Heat Source and Its Operation Characteristics)

  • 임효재;손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권2호
    • /
    • pp.30-41
    • /
    • 2021
  • This paper presents the heating performance analysis results of a heat pump system using a dual heat source. In this paper, a dual heat source refers to the ground-coupled heat exchanger using both a surface water heat exchanger (SWHE) and a vertical ground heat exchanger (VGHE). In order to evaluate the system performance, we installed a monitoring system to measure the temperature and power consumption of a heat pump and then collected operation data with 4 different load burdened ratios of the dual heat source heat exchanger. During the whole measurement period, the average heating capacity of a water-to-water heat pump unit was 37.3 kW. In addition, the compressor of the heat pump consumed 9.4 kW of power, while the circulating pump of the dual heat source heat exchanger used 6.7 kW of power. Therefore the average heating coefficient of performance (COP) for the heat pump unit was 4.0, while the entire system including the circulating pump was 2.7. Finally, the parallel use of SWHE and VGHE was beneficial to the system performance; however, further researches are needed to optimize the design data for various load ratios of the dual heat source heat exchanger.

진동형 히트 파이프를 이용한 하계 매스 콘크리트의 수화열 냉각에 관한 실험적 고찰 (An Experimental Study on Cooling of Hydration Heat of Mass Concrete Structure using Pulsating Heat Pipe in Summer Season)

  • 양태진;김정훈;김종수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권1호
    • /
    • pp.51-57
    • /
    • 2007
  • In process of reinforced concrete (RC) box structure. the heat of hydration may cause serious thermal cracking. In order to eliminate hydration heat of mass concrete. this paper reports results of hydration heat control in mass concrete structure using the pulsating heat pipe. There were three RC box molds($1.2{\times}l.8{\times}2.4m^3$) which shows a difference as compared with each other. One was not equipped with pulsating heat pipe. The others were equipped with pulsating heat pipe. All of them were cooled with natural air convection. The pulsating heat pipe was composed of serpentine type copper pipe with 10 turns (outer diameter: 4mm. inner diameter: 2.8mm). The working fluid was R-22 and its charging ratio was 40% by volume. The conditions such as the number of turns. the length and the pitch of the pulsating heat pipe and the size of concrete structure were changed. Based on these experiments, it was confirmed that this construction method using pulsating heat pipe was effective to remove hydration heat of mass concrete structure and thus it was possible to prevent harmful thermal crack and construction Period and costs of concrete structure would be cut down.

고체입자 순환유동층 열교환기의 열전달률 및 압력강하 측정 (Measurement of Heat Transfer Rates and Pressure Drops in a Solid Particle Circulating Fluidized Heat Exchanger)

  • 이금배;전용두;박상일
    • 설비공학논문집
    • /
    • 제12권9호
    • /
    • pp.817-824
    • /
    • 2000
  • The fluidized solid particles not only increase heat transfer rates but have a cleaning function eliminating contaiminated substances caused from condensate water. An experiment was performed to measure heat transfer rates and pressure drops in a fluidized heat exchanger with circulating solid particle for constant heat transfer rate. As a results, the heat transfer rate increased by 26.9~2.6%, heat transfer coefficient by 11.9~2.7%, and pressure drop by 79.1~10.9% at the gas velocity of 6.1 ~12.1 m/s and solid particle flow rate of 100~50 kg/h with the heat exchanger of H: 50 mm, $D_p=2 in,\; and\;D_{BP}$=30 mm.

  • PDF

VM열펌프의 2차해석 (A Second-Order Analysis of VM Heat Pumps)

  • 최연석;정은수
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.208-218
    • /
    • 1996
  • Performance of a VM heat pump is considerably affected by various losses, such as enthalpy dump, reheat loss, pumping loss, conduction loss and shuttle loss. A second-order analysis model of VM heat pumps, which allows consideration of the major losses, was presented. Actual heat transfer rates for heat exchangers were calculated from the heat transfer rates obtained by the adiabatic analysis and various losses. New effective temperatures of heat exchangers were calculated from the actual heat transfer rates and the mean heat transfer coefficients until there was no appreciable change in the effective temperatures. Effects of design parameters, such as phase angle, swept volume ratio, regenerator length and speed on heating capacity, cooling capacity and COP were shown.

  • PDF

플라스틱 온실(溫室)의 열저장(熱貯藏) 시스템 개발(開發)에 관(關)한 연구(硏究)(I) -수막식(水膜式) 열교환(熱交換) 시스템의 개발(開發)- (Development of Thermal Storage System in Plastic Greenhouse (I) -Development of Air-Water Heat Exchange System-)

  • 김용현;고학균;김문기
    • Journal of Biosystems Engineering
    • /
    • 제15권1호
    • /
    • pp.14-22
    • /
    • 1990
  • For efficient use of solar energy in plastic greenhouse, thermal storage system was developed. The system was constructed with the counter-flow type air-water heat exchanger using a thin polyethylene film as a medium of heat exchange parts. Experiments were carried out to investigate the heat exchange rate, optimum water flow rate, overall heat transfer coefficient, and the effectiveness of the counter-flow type air-water heat exchanger with polyethylene film bags. Mathematical model to predict air temperature leaving heat exchanger was developed. The results obtained in the present study are summarized as follows. 1. Heat exchange rate in the counter-flow type air-water heat exchanger with polyethylene film bags was compared to that of polyethylene film. Heat exchange rate was almost identical at air velocity of 0.5m/s on polyethylene film surface. But, heat exchange rate of heat exchanger with polyethylene film bag was $32{\sim}55KJ/m^2$ hr higher than that of polyethylene film at air velocity of 1.0m/s. 2. Considering the formation of uniform water film and the sufficient heat exchange rate of polyethylene film bags, optimum water flow rate in polyethylene film bags was $3.0{\sim}6.0{\ell}/m^2$ min. 3. The overall heat transfer coefficient of polyethylene film bags was found to be $35.0{\sim}130.0KJ/m^2\;hr\;^{\circ}C$ corresponding to the air velocity ranging 0.5 to 4.0 m/s on polyethylene film surface. And the overall heat transfer coefficient showed almost linearly increasing tendency to the variation of air velocity. 4. Mathematical model to predict air temperature leaving the heat exchanger was developed, resulting in a good agreement between the experimental and predicted values. But, the experimental results were a little lower than predicted. 5. Effectiveness of heat exchanger for the experiment was found to be 0.40~0.81 corresponding to the number of transfer units due to the variation of air velocity ranging 0.6 to 1.7 m/s.

  • PDF

잠열축열시스템의 축열과정에서 자연대류의 영향에 관한 연구 (Effect of Natural Convection on the Heat Transfer in a Latent Heat Storage System)

  • 유승남;한귀영
    • 태양에너지
    • /
    • 제19권2호
    • /
    • pp.29-36
    • /
    • 1999
  • Heat transfer characteristics of a low temperature latent heat storage system during the heat storage stage was examined for the circular finned tubes using fatty acid which shows the big density difference during melting as phase change materials. The heat storage vessel has the dimension of 530 mm height, 74 mm inside diameter and inner heat transfer tube is 480 mm in height and 13.5 mm outside diameter. Hot water was employed as the heat transfer fluid. During the heat storage stage, it was found that both conduction and natural convection were the major heat transfer mechanism. It was also found that the effect of natural convection on the heat transfer was more significant for the unfinned tube system than that for the finned tube system. The experimentally determined overall heat transfer coefficients were in the range of $50{\sim}250W/m^2K$ and the correlation for natural convection heat transfer as a function of Nusselt and Rayleigh number was proposed.

  • PDF

충진층 현열 축열조의 성태해소에 관한 연구 (A Study on the Performance for the Cylindrical Packed Bed Sensible Heat Storage Unit)

  • 권순석;김시범;구본영
    • 한국해양공학회지
    • /
    • 제4권2호
    • /
    • pp.85-93
    • /
    • 1990
  • A numerical study on the cylindrical packed bed sensible heat storage unit was accomplished by finite difference method. Relation between the heat storage rate and the mechanical pumping energy and the characteristics of the heat storage were investigated for various in let velocities and porosities. In this study, the numerical results are as follows: 1) The temperature distributions of solid and fluid rapidly reached the steady state as the heat capacity ratio was increased. 2) The efficiency of the heat storage was increased as the heat capacity ratio was decreased. For constant heat capacity ratio, however, the efficiency of the heat storage was increased at lower porosity. 3) It is very profitable to design the heat storage system such that the porosity is larger for the large flow rate and samller for small flow rate.

  • PDF

충진층 현열 축열조의 성태해소에 관한 연구 (A Study on the Performance for the Cylindrical Packed Bed Sensible Heat Storage Unit)

  • 권순석;김시범;구본영
    • 한국해양공학회지
    • /
    • 제4권2호
    • /
    • pp.235-235
    • /
    • 1990
  • A numerical study on the cylindrical packed bed sensible heat storage unit was accomplished by finite difference method. Relation between the heat storage rate and the mechanical pumping energy and the characteristics of the heat storage were investigated for various in let velocities and porosities. In this study, the numerical results are as follows: 1) The temperature distributions of solid and fluid rapidly reached the steady state as the heat capacity ratio was increased. 2) The efficiency of the heat storage was increased as the heat capacity ratio was decreased. For constant heat capacity ratio, however, the efficiency of the heat storage was increased at lower porosity. 3) It is very profitable to design the heat storage system such that the porosity is larger for the large flow rate and samller for small flow rate.

지열원 및 수열원 비율에 따른 복합열원 히트펌프시스템 성능 평가 연구 (A Study on the Performance Evaluation of Combined Heat Pump System according to the Ratio of Ground Heat Source and Water Heat Source)

  • 박시훈;고유진;민준기
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권2호
    • /
    • pp.11-19
    • /
    • 2021
  • In this study, combined heat source heat pump system was implemented with 4 single heat source heat pumps each applied with a geothermal source and a water source. Five cases (Case1~Case5) were configured to conduct a performance comparison and analysis of the combined heat source heat pump system. First of all, as a result of analyzing the heat source, the case when 4 ground heat sources were applied (Case1) showed a uniform EST(Entering Source Temperature) distribution throughout the year since it is less affected by outside air compared to the case when 4 water heat sources were applied (Case5). In both winter and summer, the ground heat source maintained higher EST than the water heat source. Therefore, the system with high ratio of geothermal sources is advantageous for heating, and with high ratio of water heat sources is advantageous for cooling.

냉장고 가스켓 주위의 복사열전달 효과에 관한 연구 (A Study on the Radiation Heat Transfer Effect near a Refrigerator Gasket)

  • 하지수
    • 한국산학기술학회논문지
    • /
    • 제16권3호
    • /
    • pp.1605-1610
    • /
    • 2015
  • 본 논문은 냉장고의 열손실의 약 30%를 차지하고 있는 가스켓 주위의 열전달 해석시 복사열전달을 고려하지 않은 경우와 고려한 경우가 많은 차이가 있어서 가스켓 주위의 열전달 해석시 복사열전달 고려 여부에 따른 열손실 효과를 살펴보는 연구이다. 이를 위해 가스켓 주위를 단순화한 형상으로 모델링하여 열전달 전산해석을 수행하였다. 본 연구를 통해서 가스켓 내부의 공기층을 단순히 전도열전달만 고려한 경우 열손실이 $25.6W/m^2$이고 복사열전달을 함께 고려한 경우 $55.0W/m^2$로 약 2.2배 크게 나타남을 알 수 있었다. 가스켓 내부에 복사열전달 차단판을 0에서 7개로 변화하면서 복사열전달 저감 효과를 살펴본 결과 차단판 개수가 증가하여 7개 인 경우는 설치하지 않은 경우에 비하여 열손실이 $55.0W/m^2$에서 $36.7W/m^2$로 33% 감소함을 알 수 있었다. 또한 같은 개수의 복사 차단판일 경우는 냉장고 내부와 외부에 치우치는 쪽으로 설치하는 것이 가스켓의 가운데에 설치하는 것 보다 효과적임을 알 수 있었다.