• 제목/요약/키워드: HCFC-22

검색결과 56건 처리시간 0.024초

열펌프를 이용한 R22대체 혼합냉매의 성능에 관한 연구 (A Study on the Performance of HCFC22 and Alternative Refrigerants in Heat Pumps)

  • 송영재;정동수
    • 태양에너지
    • /
    • 제18권1호
    • /
    • pp.69-79
    • /
    • 1998
  • This paper is concerned about the performance of HCFC22 alternative refrigerants used in heat pumps and industrial chillers. A water-to-water breadboard heat pump with counter-current heat exchangers and a hermetic compressor was built to carry out the experiments with various refrigerants. For each test, more than 40 temperatures, 4 pressures, power input, mass flow rates of the heat transfer fluids were measured. Refrigerants tested were HCFC22, R290(Propane), an azeotrope of 45%Propane/55%R134a mixture, and a nonazeotropic mixture of Calor 50. All tests were conducted under ARI test A condition. It is found that the COP and capacity of propane were 18% and 2.5% higher than those of HCFC22 while the COP and capacity of 45%Propane/55%R134a mixture were 3.5% and 5.3% higher than those of HCFC22 respectively. Also the COP and capacity of Calor 50 were 17% and 7.8% higher than those of HCFC22. Compressor discharge temperatures of alternative refrigerants were roughly $35^{\circ}C$ lower than that of HCFC22 indicating that these refrigerants are good from the view point of compressor reliability. The charging amounts for the alternative refrigerants were reduced by 40-60% as compared to that of HCFC22. Overall, it can be said that hydrocarbon containing alternative refrigerants are excellent in thermodynamic performance but should be used with considerable care due to their flammability.

  • PDF

수열원 히트펌프 용 HFC32/HFC152a 혼합냉매의 성능평가 (Performance of HFC32/HFC152a Mixture for Water-source Heat Pumps)

  • 강동규;김욱진;정동수
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.391-400
    • /
    • 2012
  • In this study, performance of HFC32/HFC152a mixture is measured in the composition range of 20 to 50% R32 with an interval of 10% for the comparison with the conventional HCFC22 in water-source heat pumps. Tests are carried out under the same capacity in a heat pump bench tester equipped with a variable speed compressor at the evaporation and condensation temperatures of 7/$45^{\circ}C$ and -7/$41^{\circ}C$ for summer and winter conditions, respectively. Test results show that the compressor power of the HFC32/HFC152a mixture is 13.7% lower than that of HCFC22 while the coefficient of performance(COP) the HFC32/HFC152a mixture is 15.8% higher than that of HCFC22. Hence, from the view point of energy efficiency, the HFC32/HFC152a mixture is excellent as compared to HCFC22. Compressor discharge temperatures of HFC32/HFC152a mixture are increased up to $15.4^{\circ}C$ as compared to that of HCFC22. The amount of charge for HFC32/HFC152 mixture decrease up to 27% as compared to that of HCFC22. Overall, HFC32/ HFC152a mixture is an excellent long term candidate to replace HCFC22 in water-source heat pumps.

동북아시아 지역에서의 공기괴별 HFC-23/HCFC-22의 배출특성 (Emission Characteristics of HFC-23 (CHF3)/HCFC-22 (CHClF2) between Different Air Masses in Northeastern Asia)

  • 리선란;김주일;김경렬
    • 한국대기환경학회지
    • /
    • 제26권5호
    • /
    • pp.490-498
    • /
    • 2010
  • HCFC-22 (chlorodifluoromethane, $CHClF_2$), one of the major components in various refrigeration, is emitted mostly from developing countries, as its consumption is not limited until 2013 by the Montreal Protocol. In addition, HFC-23 (trifluoromethane, $CHF_3$), a by-product in the manufacture of HCFC-22, is also a powerful greenhouse gas. Here, we discuss the regional emission characteristics of these compounds based on high-frequency in-situ measurements using the "Medusa" GC-MS system. HCFC-22 and HFC-23 baseline concentrations measured at Gosan (Jeju Island, Korea) from November 2007 to December 2008 increased by 1.8 ppt/yr and 0.6 ppt/yr, respectively. Pollution events of these compounds were observed, very frequently (e.g., ~2~3 times) at Gosan than baseline levels. All the measurement data were divided into four groups by simultaneously considering the ratio (HFC-23/HCFC-22) and concentration (HCFC-22) at Trinidad Head (TH, California, USA). The residence time of trajectories were then analyzed in each of the four groups. The results exhibited the existence of a strong correlation with air mass origin for each group: 1) Air masses originating from Siberia in the north and from the Pacific in the south had ratios of 0.08~0.12 and concentrations of 196.9~254.3 ppt which is highly comparable to background air at TH. 2) Air masses passing over the Southern China exhibited similar ratios but higher HCFC-22 concentrations. 3) Air masses passing over the Northern China had ratios of 0.12~0.21. 4) Air masses passing over Korea and/or Japan had ratios of 0.01~0.08. Our results suggest that the HFC-23/HCFC-22 ratio can be used as a good indicator for the assessment of the pollution with Chinese origin. We also confirmed differences in air masses traveling over Northern and Southern China, most likely due to differences in air mass travelling speed over these regions before arriving at Gosan. This signature may be treated as one of the critical components in identifying the emission sources from different parts of China.

고효율 수퍼히트펌프에 관한 전산 해석 (Computer Simulation of a Super-Heat Pump System)

  • 김학준;정동수;김종보;하경용
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.234-248
    • /
    • 1995
  • A super-heat pump system composed of a suction line heat exchanger, low and high stage economizers, and a screw compressor is simulated to examine the energy performance and design options. CFC12, HCFC22, HFC134a, HCFC22/HCFC142b, HFC32/HFC134a, and HFC125/HFC134a are used as working fluids for comparison. The results indicate that the proposed system charged with appropriate mixtures is up to 33.4% more energy efficient than the normal system with CFC12. The performance of the super-heat pump system charged with mixtures was influenced by such factors as the temperature matching, heat source temperature difference, low stage economizer, and high stage economizer. The fluids with a larger liquid specific heat such as HFC134a would have more benefits when a suction line heat exchanger is installed. 40%HCFC22/60%HCFC142b mixture seems to be a good candidate to replace CFC12. On the other hand, 25%HFC32/75% HFC134a would be a good long term candidate to replace HCFC22.

  • PDF

이산화탄소, HFC-l34a, HCFC-22의 열역학적 상태량 계산 절차의 응용 (Application of Procedures to Calculate Thermodynamic Properties of Carbon Dioxide, HFC-l34a and HCFC-22)

  • 박형준;박경근
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.389-396
    • /
    • 2003
  • Systematic methods to calculate thermodynamic properties of carbon dioxide, HFC-l34a and HCFC-22 are presented. First, application of a basic method to identify the saturation state with given temperature or pressure is attempted and the feasibility of auxiliary equations is tested. Next, detailed procedures are suggested to tell a phase when temperature/pressure and another property are specified. Finally Newton-Raphson method is applied to calculate unknown thermodynamic properties fixing the state with the two independent properties specified. The procedures described here are utilized to develop a computer program, which is used to find the relation between temperature and pressure with maximum isobaric heat capacity for super-critical carbon dioxide.

HCFC22 대체 R290, R1270 및 R1270/R290, R290/HFC152a, R1270/R290/RE170 혼합냉매의 공기조화기와 열펌프 작동범위에서의 성능 평가 (Performance of HCFC22 Alternatives R1270, R290, R1270/R290, R290/HFC152a, R1270/R290/RE170 Refrigerants for Air-conditioning and Heat Pump Applications)

  • 황지환;백인철;정동수
    • 설비공학논문집
    • /
    • 제18권4호
    • /
    • pp.312-319
    • /
    • 2006
  • In this study, performance of 2 pure hydrocarbons and 7 mixtures was measured in an attempt to substitute HCFC22 used in air-conditioners and heat pumps. The mixtures were composed of R1270 (propylene), R290 (propane), HFC152a, and RE170 (Dimethyl ether, DME). The pure and mixed refrigerants tested have GWPs of $3{\sim}58$ as compared to that of $CO_2$ and the mixtures are all near-azeotropic showing the gliding temperature difference (GTD) of less than $0.6^{\circ}C$. Thermodynamic cycle analysis was carried out to determine the optimum compositions and actual tests were performed in a laboratory heat pump test bench at the evaporation and condensation temperatures of 7.5 and $45.1^{\circ}C$ respectively. Test results show that the coefficient of performance (COP) of these mixtures is up to 5.7% higher than that of HCFC22. While propane showed 11.5% reduction in capacity, most of the fluids tested had the similar capacity to that of HCFC22. Compressor discharge temperatures were reduced by $11{\sim}17^{\circ}C$ with these fluids. There was no problem with mineral oil since the mixtures were mainly composed of hydrocarbons. The amount of charge was reduced up to 55% as compared to HCFC22. Overall, these fluids provide good performance with reasonable energy savings without any environmental problem and thus can be used as long term alternatives for. residential air-conditioning and heat pumping application.

고압상태의 다양한 용매 내에서 Poly(methylmethacrylate) (PMMA)의 상거동 (Phase Behavior of Poly(methylmethacrylate) (PMMA) in Varions Solvents at High Pressure)

  • 김제일;유기풍;임종성
    • 청정기술
    • /
    • 제13권1호
    • /
    • pp.28-33
    • /
    • 2007
  • 본 연구에서는 variable volume view cell이 장착된 상평형 장치를 사용하여 고압 상태의 다양한 용매 내에서 고분자인 Poly(methylmethacrylate) (PMMA)의 구름점(cloud point)를 측정하였다. 이때 사용된 용매는 chlorodifluoromethane (HCFC-22), dimethylether (DME), 1,1,1-trifluoroethane (HFC-143a), 1,1-difluoroethane (HFC-152a), 1,1,1,2-tetrafluoroethane (HFC-134a) 이였으며, 이들 용매에 $CO_2$를 첨가한 $HCFC-22+CO_2$$DME+CO_2$의 이성분계 혼합용매에서 $CO_2$의 조성 변화가 PMMA의 상거동에 미치는 영향을 살펴보았다. 실험 결과 PMMA는 HCFC-22에서는 340K, 5MPa 정도의 가장 낮은 온도 압력 조건에서부터 잘 용해되었으며 DME에서는 300K, 28MPa 정도의 비교적 낮은 온도 압력 범위에서 잘 용해되었으나, 그 밖의 불소화합물인 HFC-143a, HFC-152a, HFC-134a에서는 423.15K, 160MPa의 높은 온도 및 압력범위에서도 전혀 용해가 일어나지 않았다. 또한, PMMA+HCFC-22 혼합물에 $CO_2$를 첨가한 $PMMA+HCFC-22+CO_2$계의 경우는 LCST (lower critical solution temperature)의 상거동을 보였으나 PMMA+DME 혼합물에 $CO_2$를 첨가한 $PMMA+DME+CO_2$계의 경우는 UCST (upper critical solution temperature)의 상거동을 보였다. $CO_2$ 혼합용매 내에서 cloud point 압력은 동일한 온도에서 첨가되는 $CO_2$의 양에 비례하여 급격히 높아지는 것을 관찰할 수 있었고, 이로부터 PMMA를 SAS (supercritical antisolvent) 법에 의해 미세입자화 할 경우 $CO_2$가 DME와 HCFC-22에 대한 역용매로 사용될 수 있다는 것을 확인할 수 있었다. 또한 $CO_2$의 농도를 변화시킴으로써 PMMA의 cloud point를 자유롭게 조절할 수 있다는 것을 알 수 있었다.

  • PDF

R-12, R-134a 및 R-22를 사용한 무급유식 스크롤압축기의 성능 비교 (A Performance Comparison of Oil-free Scroll Compressors with R-12, R-134a and R-22)

  • 박희용;박경우;박용일
    • 설비공학논문집
    • /
    • 제5권4호
    • /
    • pp.306-317
    • /
    • 1993
  • In this study, a performance comparison of scroll compressor for various refrigerants(CFC-12, HCFC-22 and HFC-134a) has been numerically carried out. The thermodynamic properties have been calculated by using the recent experimental equations and the performance has been investigated qualitatively at the same geometric specifications and operating conditions of scroll compressor. The results are as follows; HFC-134a has the highest compression ratio of 5.40. The mass flow rate of HCFC-22, which affects the cooling capacity of refrigerant system, is higher than that of other refrigerants. HFC-134a has the highest adiabatic efficiency in comparison with CFC-12 and HCFC-22.

  • PDF

가정용 냉방기의 대체 냉매 성능 분석을 위한 전산 해석 연구 (Computer Simulation Study for Analyzing Alternative Refrigerants in Residential Air-conditioners)

  • 유환규;정동수
    • 태양에너지
    • /
    • 제15권3호
    • /
    • pp.75-90
    • /
    • 1995
  • 본 논문은 가정용 냉방기에 널리 사용되고 있는 HCFC22를 대체할 수 있는 혼합냉매의 개발 및 이들의 성능 연구에 관한 것이다. 현재까지 HCFC22를 대체할 수 있는 순수냉매가 없으므로, 혼합냉매 개발에 본 연구의 초점이 맞추어졌고, 이를 위해 가정용 냉방기를 모사 하는 컴퓨터 프로그램이 개발되었다. 연구에서 개발된 혼합냉매를 구성하는 순수냉매들은 다음과 같다: R32, R124, R125, R134, R134a, R143a, R152a. 컴퓨터 모사 결과들은 다음의 혼합냉매들에 대해서 발표되었다: R32/R134a, R32/R152a, R32/R134, R32/R124, R143a/R134a, R143a/R152a, R143a/R124, R125/R134a, R125/R152a, R125/R124, R32/R152a/R134a, R32/R152a/R134, R32/R152a/R124. 가장 좋은 에너지 효율을 보인 것은 삼원 혼합냉매인 R32/R152a/R124로서, HCFC22에 비해 이것의 성적 계수는 13.7% 높고 냉동 능력은 23% 낮은 것으로 판명되었다. 한편 이원 혼합냉매 중 가장 성능이 좋은 것은 R32/R124로서 이것의 성적 계수는 HCFC22에 비해 13.4% 높고 냉동 체적 용량은 9.6% 낮은 것으로 판명되었다.

  • PDF

HCFC-22 냉매사용 차량냉동시스템의 증발 열전달에 관한 실험 (An Experiment on Evaporating Heat Transfer of HCFC-22 for Transport Refrigeration System)

  • 오명도;김선창
    • 설비공학논문집
    • /
    • 제6권2호
    • /
    • pp.166-174
    • /
    • 1994
  • An experimental study has been performed to identify the evaporation characteristics of HCFC-22 for transport refrigeration system. Heat transfer coefficients were measured in a horizontal, smooth evaporating tube with an inner diameter of 10.7mm and a length of 2.8m. The refrigerant was heated electrically by surface-wrapped heaters and uniform power is applied along the tube. The entire tube was divided into 7 sections. Surface temperatures of tube and refrigerant temperature in each test section were measured. Pressure drops in each section and the inlet pressure were also measured. The mass flowrate of the refrigerant was controlled and measured. A single tube evaporation test was conducted for different ranges of mass flux of refrigerant, heat flux of evaporator and condensing temperature of transport refrigeration system. The evaporation heat transfer coefficients of HCFC-22 were compared with predictions from the well known Chen's correlations. Averaged heat transfer coefficients in this experiment range from $2kW/m^2/^{\circ}C$ to $3kW/m^2/^{\circ}C$. Most of the experimental results differ from the predicted ones by less than ${\pm}30%$.

  • PDF