• Title/Summary/Keyword: HAp

Search Result 471, Processing Time 0.03 seconds

Realtime Mobile Base Station Placement with EM Algorithm for HAP based Network (HAP 기반 네트워크에서의 EM 알고리즘을 사용한 실시간 이동 기지국 배치)

  • Jung, Woong-Hee;Song, Ha-Yoon
    • The KIPS Transactions:PartC
    • /
    • v.17C no.2
    • /
    • pp.181-189
    • /
    • 2010
  • HAP(High Altitude Platform) is a stationary aerial platform positioned in the stratosphere between 17Km and 22Km height and it could act as an MBS (Mobile Base Station). HAP based Network has advantages of both satellite system and terrestrial communication system. In this paper we study the deploy of multiple HAP MBS that can provides efficient communication for users. For this study, EM(Expectation Maximization) clustering algorithm is used to cluster terrestrial mobile nodes. The object of this paper is improving EM algorithm into the clustering algorithm for efficiency in variety aspects considering distance between mobile terminal units and speed of mobile terminal units, and estimating performance of HAP MBS deploy technique with use of improved EM algorithm using RWP (Random Waypoint) node mobility.

A CLINCO-RADIOGRAPHIC STUDY ON EFFECT OF HAP USED AFTER ODONTOGENIC CYST ENUCLEATION (치성 낭종 적출술후 사용된 HAP의 효과에 대한 임상적 방사선학적 연구)

  • Rim, Jae-Seok;Kim, Seong-Mun;Ryu, Jae-Jun;Kim, Hui-Jong;Lee, Sang-Eun;Cho, Min
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.12 no.3
    • /
    • pp.57-62
    • /
    • 1990
  • Many alloplastic materials have been used as the bony substitute in large bony defects caused by fracture, periodontitis, & cyst, etc. Nowadays Hydroxyapatite(HAP) is the most usable material as the bony substitute. The reasonable properties of HAP are nontoxic, biocompatible to host tissues & have osteoconductivity. Other bioceramic materials are recommended as the bony substitute with high success rate. We have studied the clinical use of HAP as the bony substitute in the defected area caused by cyst. The reasonalbe & successful results are obtained. The results were as followed. 1. Better prognosis was obtained in the case of HAP & bone mixed graft than HAP graft only. And the best prognosis was obtained in the case of iliac bone graft. 2. Better prognosis was obtained in Mx. than in Mn. 3. It seems that the soft tissue ingrowth into the HAP granule play an important role in the success of the HAP graft. 4. Though the flap covering the HAP granules was perforated, the relative good prognosis was obtained by re-suturing the perforeated site.

  • PDF

The Antimicrobial Effect of Structure Modified Apatite (구조개질 Apatite의 항균효과)

  • 강전택;정기호
    • Journal of Environmental Science International
    • /
    • v.10 no.6
    • /
    • pp.387-391
    • /
    • 2001
  • The hydroxyapatite(HAp) as a carrier the for ion exchange agent of $Ag^+$ions was prepared in semiconductor fabrication, The Ca/P molar ratio of the HAp was 1.65. The HAp is molded in shape of the antimcrobial ball and then sintered at 100$0^{\circ}C$ Ag-containing HAp(HAp-Ag) was prepared by incorporating $Ag^+$/ions in HAp crystals through an ion-exchange reaction in solutions containing 0.01M $AgNO_3$. The antimicrobial effect of HAp-Ag for bacteria such as Escherichial coli and Staphylococcus aureus has been Investigated. The concentrations of silver in the antimicrobial ball was determined by inductively coupled plasma and the amount of $Ag^+$ions was 9.0$\mu\textrm{g}$/g. The HAp-Ag exhibited excellent antimicrobial effect for bacteria such as E. coli and S. aureus. The bactericidal activity was considered to be caused by direct contact of bacteria with $Ag^+$ions in the HAp crystals. The HAp would likely to be possible as a carrier of antimicrobial metal ions such as Ag, Cu, and Zn by recycling of waste sludge in the semiconductor fabrication process.

  • PDF

Evaluation of Plasma Spray Hydroxy Apatite coatings on Metallic Materials

  • Take, S.;Mitsui, K.;Kasahara, M.;Sawai, R.;Izawa, S.;Nakayama, M.;Itoi, Y.
    • Corrosion Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.286-290
    • /
    • 2007
  • Biocompatible Hydroxy apatite (HAp) coatings on metallic substrate by plasma spray techniques have been developed. Long-term credibility of plasma spray HAp coatings has been evaluated in physiological saline by electrochemical measurements. It was found that the corrosion resisitance of SUS316L based HAp/Ti conbined coatings was excellent even after more than 10 weeks long-term immersion. It was shown that postal heat treatment improved both the crystallinity and corrosion resistance of HAp. By lowering cooling rate during heat treatment process, less cracks produced in HAp coating layer, which lead to higher credibility of HAp during immersion in physiological saline. The ICP results showed that the dissolution level of substrate metallic ions was low and HAp coatings produced in this research can be acceptable as biocompatible materials. Also, the concentration of dissolved ions from HAp coatings with postal heat treatment was lower compared to those from samples without postal heat treatment. The adherence of HAp coatings with Ti substrate and other mechanical properties were also assessed by three-point bending test. The poor adhesion of HAp coating to titanium substrate can be improved by introducing a plasma spray titanium intermediate layer.

Regeneration of a Micro-Scratched Tooth Enamel Layer by Nanoscale Hydroxyapatite Solution

  • Ryu, Su-Chak;Lim, Byoung-Ki;Sun, Fangfang;Koh, Kwang-Nak;Han, Dong-Wook;Lee, Jae-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.4
    • /
    • pp.887-890
    • /
    • 2009
  • Hydroxyapatite (HAp)-based materials have attracted considerable attention on account of their excellent stability and recrystallization. Nanoscale HAp powders with a mean particle size of 200 nm were used to regenerate the enamel layers of damaged teeth. An artificially scratched tooth was immersed in a nanoscale HAp powder suspension in d.i. water (HAp of 70 wt%) at 37 ${^{\circ}C}$ for a period of 1~3 months. SEM and AFM showed that the scratched surface was ultimately inlaid with HAp after three months and the roughness increased from 2.80 to 5.51. Moreover, the hardness of the neo-generated HAp layer on the crown was similar to that of the innate layer. $Ca^{2+}$ and ${PO_4}^{3-}$ ions from the HAp powders dissolved in d.i. water were precipitated on the tooth to produce cemented pasteson the enamel surface due to its high recrystallizing characteristics, resulting in a hard neo-regenerated HAp layer on the enamel layer. This nanoscale HAp powder solution might be used to heal decayed teeth as well as to develop tooth whitening appliances.

A Study on the Hydroxyapatite-Zirconia Composite Bioceramics (Hydroxyapatite Zirconia 계 복합 Bioceramics에 관한 연구)

  • 이종필;최현국;송종택;최상흘
    • Journal of the Korean Ceramic Society
    • /
    • v.28 no.4
    • /
    • pp.289-296
    • /
    • 1991
  • Hydroxyapatite (HAp)-zirconia bioceramics, which have excellent biocompatibility with tissue of bone and tooth and good mechanical properties, were synthesized, and their properties and biocompatibility were investigated. HAp powders were synthesized with Ca/P=1.67 and pH 11 by precipitation method. A fine spherical monodispersed ZrO2 powders were prepared by metal alkoxide method, and then they were partially stabilized with 10 mol% CaO by solid state reaction at 1300℃. HAp-zirconia composites were prepared by sintering of these HAp mixed with various amount CaO-partially stabillized zirconia (PSZ). When HAp containing 15 wt% PSZ with 10 mol% CaO (PSZ(10C)) were sintered at 1250℃, it was prevented to decompose into TCP and ZrO2 was uniformly dispersed at HAp matrix. Mechanical strength of these sintered bodies were increased by addition of 15 wt% PSZ(10C), the bending strength of compacts fired at 1250℃ was 165 MPa. HAp-PSZ composites chemically bonded each other in Ringer's solution and the component of bonded layer was HAp. These composites did not prevent cell-growing and exhibit any cytotoxic effects.

  • PDF

알콜 산화반응에 적합한 HAP를 기질로 이용한 이종상 촉매의 합성과 특성연구

  • Kim, So-Hui;Jaworski, Justyn;Gwon, Gi-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.330-330
    • /
    • 2011
  • 공기 중 산소를 이용한 다양한 산화반응에 적합한 이종상 촉매 개발이 공업적으로나, 학문적으로 중요한 의미를 갖는다. 우리는 수산화 인회석(hydroxyapatite, HAP)에 Ru이 도입된 새로운 이종상 촉매를 합성하였으며, 이를 이용하여 알콜 산화 반응을 통해 반응성을 관찰하였다. 우리는 다양한 형태의 결정구조와 표면구조를 가지는 HAP를 합성하였으며, 이를 AFM, ICP, XRD, SEM를 통하여 결정구조를 분석하였다. 각각에 대해서 수용액상에서 Ion exchange 반응을 통하여 Ru를 HAP 표면에 치환하여 여러 종류의 RuHAP를 합성하였다. 특히, 알콜 산화반응을 통해 HAP의 결정 형태에 따라서 반응성의 차이를 가짐을 알 수 있었다. HAP는 Molten salt synthesis 방법을 이용하여 합성한 일정한 형태의 단결정과 무정형의 다결정 즉, 두 가지 다른 형태를 이용하여 각각에 대해 칼슘이 부족한 형태로써, Ca과 Ru과의 Ion exchange 반응을 통해 다양한 종류의 HAP를 합성하여 알콜 산화반응의 촉매로서 가지는 반응성을 연구하였다.

  • PDF

SIL VER-IMPREGNATED HAP-COATING ON ALUMINA SUBSTRATE FOR PREVENTION OF INFECTION

  • Kim, T.N.;Feng, Q.L.;Wu, J.;Kim, J.O.
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.27-33
    • /
    • 1997
  • Recently ion beam assistant deposition (IBAD) was successfully used to produce a dense ultra-adherent and pinhole-free hydroxyapatite (HAp) layer on alumina substrate. After that the HAp-coated alumina was immersed in 20ppm and 100ppm $AgNO_3$ solution at room temperature for 48 hours to carry out the ions exchange between $Ag^+\;and\;Ca^+$ in HAp. The obvious antimicrobial effect against E.Coli, P. Aeruginosa and S. Epidermidis was observed in the samples treated with 20ppm $AgNO_3$ Solution, In contrast to this the untreated samples did not show any bactericidal effect. Scanning electron microscope(SEM) study showed that Ag homogeneously distributed on the surface. X-ray diffraction (XRD) demonstrated that the surface structure in the samples without Ag was HAp whereas with Ag is HAp and AgCaP. It appears that silver ions exchange with calcium ions in HAp does not cause significant changes in the structure of HAp coatings.

  • PDF

Morphology and Mechanical Properties through Hydroxyapatite Powder Surface Composite (Hydroxyapatite의 파우더 표면 복합화를 통한 형태 및 기계적 성질에 관한 연구)

  • Kye, Sung Bong;Park, Soo Nam
    • Applied Chemistry for Engineering
    • /
    • v.27 no.3
    • /
    • pp.299-306
    • /
    • 2016
  • In this study, new hydroxyapatite powder surface composites were investigated for protective effects against ultraviolet rays. Hydroxyapatite (HAp) is biocompatible and does not cause nebula phenomenon on skin. We investigated the surface modification of hydroxyapatite to improve UV block and skin usage. Dimethicone, lauroyl lysine, triethoxycaprylylsilane and silica were used as coating agents for the surface modification of HAp. To prepare the composite complex of the modified surface, the dimethicone, lauroyl lysine and triethoxycaprylylsilane were prepared by a dry process, and silica by a hydrothermal synthesis method. The HAp-silica was chosen as the best composite powder when measuring its sun protection levels. We investigated the characteristics of the surface of HAp-silica by SEM, particle size analyzer and energy dispersive spectrometry (EDS). Additionally, the stability in the formulation, UV block effect, and safety in BB creams were investigated. In conclusion, HAp-silica prepared by the modification of HAp complex surface improved the skin usage and UV block effect by enhancing the white cloudy phenomenon. These results indicate that HAp-silica may be used for UV block cosmetics.

The Sorption Kinetic Studies and Development of Mixed Culture for Removal of Nonpoint Pollution Source (비점오염원 처리를 위한 혼합여재의 개발 및 흡착 Kinetic 연구)

  • Chung, Woojin;Lee, Sijin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.4
    • /
    • pp.37-44
    • /
    • 2012
  • This study investigated on the adsorption of nonpoint pollution source using the Sand, hydroxyapatite(HAP), Zeolite and mixed culture. The adsorption of nonpoint pollution source on Sand, hydroxyapatite(HAP), Zeolite and mixed culture was investigated during a series of batch adsorption experiments. After the batch absorption experiments analysed COD, T-N, T-P on adsorption water. The experimental data was analysed using the pseudo-first-order adsorption kinetic models. Langmuir and Freundlich isotherm models were tested for their applicability. The maximum adsorbed amount $(Q_{max})$ of COD were found to be sand 0.0511mg/g, HAP 0.1905mg/g, Zeolite 1.0366mg/g and Mixed media 0.7444mg/g. The maximum adsorbed amount $(Q_{max})$ of T-N were found to be sand 0.0159mg/g, HAP 0.0537mg/g, Zeolite 0.5496mg/g and Mixed media 0.1374mg/g. The maximum adsorbed amount $(Q_{max})$ of T-P were found to be sand 0.0202mg/g, HAP 0.1342mg/g, Zeolite 0.0462mg/g and Mixed media 0.1180mg/g. As a result, the mixed media was effective to remove nonpoint pollution source.