• Title/Summary/Keyword: HAT: Horizontal axis turbine

Search Result 15, Processing Time 0.025 seconds

Study on Power Measurement and Comparison of Marine Current Turbine in a Towing Tank (예인수조를 이용한 조류발전 터빈의 동력 계측 및 비교 연구)

  • Do, In-Rok;Kim, Moon-Chan;Lee, Seung-Ki;Hyun, Beom-Soo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.4
    • /
    • pp.230-238
    • /
    • 2011
  • The experimental study for the performances of 100 kW marine current turbines (Horizontal Axis Turbine) has been conducted with three cases of 700 mm diameter model in PNU 100 m towing tank. Three cases of impeller have been designed according to the variation of section configuration and tip shape. The model tests have been carried out at different speed of revolution to find out the scale effect (Reynolds number effect). The designed rake impeller was the best among them in the efficiency point of view especially at high Tip Speed Ratio (TSR). The present study is expected to be extended to conduct at high reynolds number as well as the computational study for the validation.

The Optimum Design and Wake Analysis of Tidal Current Power Turbine (조류발전 터빈 최적화 설계 및 후류 영향 연구)

  • Jo, Chulhee;Kim, Doyoub;Lee, Kanghee;Rho, Yuho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.164.2-164.2
    • /
    • 2011
  • 지구온난화에 따른 대체에너지 자원확보가 국가적으로 중요한 과제로 대두되고 있고 여러 대체에너지원 중 국내의 해양에너지는 잠재량이 매우 높다. 여러 해양에너지 중에서 빠른 흐름을 이용하는 조류발전은 서해안과 남해안에 적용하기에 적합하며 해양환경을 보존하면서 많은 에너지를 생산할 수 있는 장점이 있다. 조류발전에서 1차적으로 에너지를 변환시키는 로터는 주요한 장치중의 하나로 여러 변수에 의해 그 성능이 결정된다. 로터의 블레이드 수, 형상, 단면적, 허브, 직경 등 여러 요소를 고려하여 설계되어야 한다. 또한 조류발전을 적용하는 해양환경에서 최대 출력을 생산할 수 있는 로터가 적용될 수 있도록 블레이드의 후류 영향을 고려해야한다. 본 논문에서는 날개요소이론을 바탕으로 수평축 조류발전 터빈을 설계하여 실험 및 유동해석을 통해 성능을 평가하고, 후류에 미치는 영향을 분석하였다.

  • PDF

Empirical Evaluation of Tidal Current Generation System at Ul-Dol-Mok in Jin-do (진도 울돌목 조류발전 시스템 실증 평가)

  • Moon, Seok-Hwan;Park, Byung-Gun;Kim, Ji-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.2
    • /
    • pp.157-163
    • /
    • 2016
  • The empirical evaluation of grid-connected tidal current generation system is presented in this paper. The Ul-dol-mok in Jin-do has been estimated to have tidal power of 1GW. In order to experiment, HAT (Horizontal Axis Turbine) 3-blade and 20kW grid-connected tidal current generation system was established at Ul-dol-mok in Jin-do. To generate power of generator, the speed reference of the PMSG is generated from the Cp curve and TSR (Tip Speed Ratio) of the designed turbine. The control of the converter connected to the grid is controlled to regulate unity power factor. The result showed that the turbine efficiency and system efficiency is 37 % and 31 %. This was achieved that target rate is 30 %, 20 %, respectively.

HAT Tidal Current Turbine Design and Performance Test with Variable Loads (조류발전용 수평축 터빈의 형상설계 및 가변 부하를 이용한 성능실험)

  • Jo, Chul-Hee;Rho, Yu-Ho;Lee, Kang-Hee
    • New & Renewable Energy
    • /
    • v.8 no.1
    • /
    • pp.44-51
    • /
    • 2012
  • Due to a high tidal range of up to 10 m on the west coast of Korea, numerous tidal current projects are being planned and constructed. The turbine, which initially converts the tidal energy, is an important component because it affects the efficiency of the entire system. Its performance is determined by design variables such as the number of blades, the shape of foils, and the size of a hub. To design a turbine that can extract the maximum power on the site, the depth and duration of current velocity with respect to direction should be considered. Verifying the performance of a designed turbine is important, and requires a circulating water channel (CWC) facility. A physical model for the performance test of the turbine should be carefully designed and compared to results from computational fluid dynamics (CFD) analysis. In this study, a horizontal axis tidal current turbine is designed based on the blade element theory. The proposed turbine's performance is evaluated using both CFD and a CWC experiment. The sealing system, power train, measuring devices, and generator are arranged in a nacelle, and the complete TCP system is demonstrated in a laboratory scale.

Study on Performance Variation According to the Arrangements of Adjacent Vertical-Axis Turbines for Tidal Current Energy Conversion (인접한 조류발전용 수직축 터빈의 배치방식에 따른 성능 변화)

  • Lee, Jeong-Ki;Hyun, Beom-Soo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.2
    • /
    • pp.151-158
    • /
    • 2016
  • Tidal farm is a multi-arrayed turbine system for utilizing tidal stream energy. For horizontal-axis turbine(HAT) system, it is recommended that each unit has to be deployed far apart in order to avoid hydrodynamic interference among turbines, as proposed by the European Marine Energy Centre(EMEC). But there is no rule for the arrangement of vertical-axis turbine(VAT) yet. Moreover it has been reported that a proper arrangement of adjacent turbines can enhance the overall efficiency even greater than an arrangement without mutual interference effect. This paper suggests the layout of VATs showing the better performances, which turned out to be quite different from HATs' arrangement. Numerical calculations were performed to investigate the performance variation in terms of the rotational direction as well as the distance between turbines. It has been shown that the best combination of rotational direction and distance between turbines can increase its performance higher about 9.2% than that of two independently operated turbines. It is likely that such improvement is due to the increased velocity between adjacent turbines. For diagonally arranged turbines, the maximum normalized mean power coefficient was obtained to be higher about 5.6% than that of two independent turbines. It is expected that the present results can be utilized for conceptual design of tidal farm to harness the tidal stream energy.