• Title/Summary/Keyword: HA-coated surface

Search Result 193, Processing Time 0.024 seconds

Surface Damage Characteristics of Self-Assembled Monolayer and Its Application in Metal Nano-Structure Fabrication (자기 조립 분자막의 표면파손특성 및 미세 금속 구조물 제작에의 응용)

  • Sung, In-Ha;Kim, Dae-Eun
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.40-44
    • /
    • 2002
  • The motivation of this work is to use SAM(Self-Assembled Monolayer) for developing a rapid and flexible non-photolithographic nano-structure fabrication technique which can be utilized in micro-machining of metals as well as silicon-based materials. The fabrication technique implemented in this work consists of a two-step process, namely, mechanical scribing followed by chemical etching. From the experimental results, it was found that thiol on copper surface could be removed even under a few nN normal load. The nano-tribological characteristics of thiol-SAM on various metals were largely dependent on the native oxide layer of metals. Based on these findings, nano-patterns with sub-micrometer width and depth on metal surfaces such as Cu, Au and Ag could be obtained using a diamond-coated tip.

  • PDF

Polypyrrole-coated Carbon Nanotube as High Capacity Anode Material for Aqueous Rechargeable Na-ion Battery (수계 나트륨 이차전지용 고속 충·방전 음극 활물질로서의 폴리피롤-CNT)

  • Im, Ha-Na;Lee, Ho-Nyeon;Kim, Hyeon-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.253-253
    • /
    • 2015
  • 수계 나트륨 이차전지는 발화 위험이 전혀 없고, 기존 유기계 리튬 배터리에 비해 고속 충 방전 특성을 가지며, 리튬 대신 나트륨을 적용해 가격 경쟁력에서도 매우 우수한 포스트 리튬 이차전지로 알려져 있다. 본 연구에서는 폴리피롤을 CNT 표면에서 중합하여 나노 코드 형태의 PPy/CNT를 제조하여 수계 나트륨 이차전지의 음극 활물질로 적용하였다. 폴리피롤과 CNT의 복합화에 의해 이론용량에 가까운 용량을 얻을 수 있었으며, 10C 이상의 고속 충 방전 조건에서도 안정적인 출력을 보이는 것으로 확인하였다. 벌크상태의 PPy에서는 볼 수 없는 독특한 전기화학적 특성이 있음을 확인하였으며, 폴리피롤에서의 독특한 충 방전 메커니즘을 제안할 수 있었다.

  • PDF

Aluminum Oxide Photonic Crystals Fabricated on Compound Semiconductor (화합물 반도체 기판 위에 제작된 산화 알루미늄 광결정 특성)

  • Choi, Jae-Ho;Kim, Keun-Joo;Jung, Mi;Woo, Duk-Ha
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.77-78
    • /
    • 2006
  • We fabricated photonic crystals on GaAs and GaN substrates. After anodizing the aluminium thin film in electrochemical embient, the porous alumina was implemented to the mask for reactive ion beam etching process of GaAs wafer. And photonic crystals in GaN wafer were also fabricated using electron beam nano-lithography process. The coated PMMA thin film with 200 nm-thickness on GaN surface was patterned with triangular lattice and etched out the GaN surface by the inductively coupled plasma source. The fabricated GaAs and GaN photonic crystals provide the enhanced intensities of light emission for the wavelengths of 858 and 450 nm, respectively. We will present the detailed dimensions of photonic crystals from SEM and AFM measurements.

  • PDF

Mechanical Analysis of Field Coil Deformation in Gas Turbine Generator (가스터빈 발전기의 계자권선 손상에 관한 역학적 분석)

  • Han, Seok-Woo;Kwon, Young-Dong;Choe, Gyu-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.107-109
    • /
    • 1998
  • This paper presents mechanical analysis of gas turbine generator (113MVA, $3{\phi}$, 2P, 0.9PF, F class, 3600rpm, 60Hz, 13.8kV, 4.72kA, Air-Cooling) field coil deformation. Rotor end coil deformation is only appeared on turbine end but collector end coil is normal. Expansion direction of end coil is tangential not axial. Deformation appears more severe at top turn. Retaining ling is expanded by centrifugal force of coil and itself. In case friction coefficient between coil top surface and retaining ring insulation inner surface is small, coil end length ${\ell}$ does not change. However, in case friction coefficient big condition, coil end is expanded ${\Delta}{\ell}$ due to start and stop. Deformation is assumed about 30mm by watching photograph inner surface of retaining ring is coated by Teflon at manufacturing condition. Usually Teflon coating insulation surface is small friction coefficient. It's value 0.08${\sim}$0.15. However it's value exceeds more than 0.297. Since top turn deformation appears. The distortion and subsequent failure have occurred because of the lack of a sufficient slip-plane between the top field coil conductors and the inside surface of the retaining ring insulation on the turbine end of the field-winding.

  • PDF

Effects of Application of Latex Coated Urea on Yield and Nitrogen-Use Efficiency for 10-day Old Seedling Machine Transplanted (Latex 피복요소시용(被覆尿素施用)이 어린모기계이앙(機械移秧) 벼의 질소이용효율(窒素利用效率)과 수량(收量)에 미치는 영향)

  • Yoo, Chul-Hyun;Kang, Seung-Weon;Shin, Bog-Woo;Han, Sang-Soo;Kim, Seong-Jo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.2
    • /
    • pp.140-146
    • /
    • 1999
  • This research was conducted to investigate the changes of $NH_4-N$ in soil, nitrogen uptake by rice plant, nitrogen-use efficiency and rice yield by the application of latex coated urea(LCU) on 10-day old seedling transplanted with machine on paddy field, Jeonbuk series at the Honam area, from 1997 to 1998. Almost all nitrogen in LCU application as basal dressing in whole layer was dissolved until maximum tiller stage, the maximum dissolution time was productive tiller stage and $NH_4-N$ content of conventional plot with surface application of fertilizer were lowered at full periods. Nitrogen deficiency symptom were appeared at heading stage of 31.6% SPAD value and nitrogen concentration was 1.29% shoot. From heading stage to ripening stage, the necessity of nitrogen-fertilizer was $2.9kg\;ha^{-1}$ for the conventional split application plot and $11.9kg\;ha^{-1}$ for the whole layer application plot of LCU basal dressing. Nitrogen-use efficiency was higher at the LCU application plot than the conventional application plot and was increased for 12.7% by fertilization at panicle forming stage. The additional fertilization at panicle forming stage to basal dressing of LCU causes 13% yield increase.

  • PDF

Hysteresis Loss in a $Sm_1Ba_2Cu_3O_{7-\delta}$ Coated Conductor under Simultaneously Applied Field and Current with Phase Differences (위상차를 갖고 변화하는 자기장과 전류가 동시에 가해진 $Sm_1Ba_2Cu_3O_{7-\delta}$ Coated Conductor의 자기이력 손실)

  • Lee, Sang-Moo;Jung, Ye-Hyun;Kwak, Ki-Sung;Rhee, Joon-Kyu;Yoo, Jae-Un;Youm, Do-Jun;Kim, Ho-Sup;Ha, Hong-Soo;Oh, Sang-Soo
    • Progress in Superconductivity
    • /
    • v.10 no.2
    • /
    • pp.92-98
    • /
    • 2009
  • The magnetic field profiles near the surface of a $Sm_1Ba_2Cu_3O_{7-\delta}$ coated conductor(CC-tape) under magnetic field and current that were applied simultaneously with phase differences ${\phi}s$ were measured using scanning Hall probe method. Measurements were carried out along the elliptic load lines with $\phi=90^{\circ}\;and\;45^{\circ}$ for some $B_{peak},\;I_{peak}$ values. From the measured field profiles, sheet current density J(x, $B_a,\;I_a$) and magnetic flux density $B_0(x,\;B_a,\;I_a)$ profiles in the CC-tape were calculated. Using these J(x, $B_a,\;I_a$) and $B_0(x,\;B_a,\;I_a)$ profiles, we estimated the hysteresis energy loss Q in the CC-tape. The estimated Qs, together with our previous results for $\phi=0^{\circ}$ from [9], were compared with theoretical values based on Brandt's calculation.

  • PDF

The retrospective study of survival rate of implants with maxillary sinus floor elevation (상악동 거상술을 동반한 임플란트 식립 후 생존율에 대한 후향적 연구)

  • Yu, Jeoung-A;Lee, Sang-Min;Yoo, Mi-Kyung;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Park, Pil-Kyoo;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.3
    • /
    • pp.293-301
    • /
    • 2009
  • Purpose: The purpose of this study is to show the total survival rate of implants with maxillary sinus floor elevation and the effects that reach the survival rate by classifying types of graft materials, implant surface, operation method, bone height. Methods: In a total of 131 patients, 251 implants with sinus floor elevation were installed simultaneously or after regular healing. Various bone grafts (autograft, xonograft, allograft, alloplast) and implant surface (MTX-HA implant, chemical etching implant, Titanium oxide surface implant, resorbable blasting media implant, resorbable blast texturing implant, HA-coated implant) were used. All implants were investigated clinically and radiographically, being with 1 to 5 years follow-up period after installation. Results: The survival rate of 251 implants with maxillary sinus floor elevation was 94%. The types of implant, surface, graft material, bone height have no statistically signi-ficant differencies. Conclusions: It can be suggested that maxillary sinus floor elevation may have predictable result with various bone graft materials and implant surface.

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS: HISTOMORPHOMETRIC AND RESONANCE FREQUENCY ANALYSIS IN DOGS

  • Song Woo-Seok;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.671-678
    • /
    • 2004
  • Statement of problem. Reducing treatment time in implant dentistry is a matter of main concern. There are so many factors affecting the success rate of immediate or early loaded implant for the initial bone response. The especially microscopic properties of implant surfaces playa major role in the osseous healing of dental implant. Purpose. The aims of this study were to perform a histologic and histomorphometric comparison of the healing characteristics anodically roughened surface, HA coated surface and RBM surface implant, and to compare of ISQ values measured by $Osstell^{TM}$ for resonance frequency analysis in dogs mandible during 2 weeks. Material and method. Bone blocks from 2 dogs were caught after covered healing for 0 day(2 h); Group I, 1 week; Group II and 2 weeks; Group III. One longitudinal section was obtained for each implant and stained with hematoxylin and eosin. Histomorphometric analysis was done with Kappa Imagebase system to calculate bone-to-implant contact and bone volumes inside the threads. ISQ values were measured in every time of surgery schedule. Conclusion. The experiment revealed that: 1. The percentages of bone-to-implant contact on the fixture in each group were not significantly different(P > 0.05). 2. The percentages of bone area inside the threads on the fixture in each group were not significantly different(P > 0.05). 3. The ISQ level showed clinical stability of each fixture during 2 weeks(all ISQ level ${\geq}71$ ).

Manufacture and Application of UV-Cured Anti-cigar burning Coating Compounds for PVC Tile (PVC 바닥상재용 광경화형 내열 코팅액의 제조 및 응용에 관한 연구)

  • Park, Bo-Ram;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.608-613
    • /
    • 2010
  • This study is on development of UV-cured water soluble coating composition which have more improved anti-cigar burning to prevent a surface of PVC tile from damage of heat. To make an anti-cigar burning coating solution, thermostable agent that synthesize main materials phosphorus compound, guanidine and ammonium phosphate dibasic used temporary flame retardants, changing their contents from 10 to 30wt% against quantities of resin and compounded. After coating PVC tiles using bar-coating method that can adjust a thickness, we estimated surface properties of coated layer such as anti-cigar burning, adhesive power, chemical resistance, thickness of coating, and so on. Results showed that a coating composition added 30 wt% of phosphorus compound and coated with No.12 bar-coater had the best optimized surface property in anti-cigar burning effect, adhesive power and chemical resistance. Also, we could find anti-cigar burning effect was improved as thermostable agents content and coating thickness increased.

Ability to Maintain Postural Control while Standing on Perturbed Surfaces (바닥면의 교란에 따른 자세균형능력의 변화)

  • Park, Sung-Ha;Lee, Seung-Won
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.31 no.4
    • /
    • pp.146-152
    • /
    • 2008
  • This study was aimed to understand the effects of perturbed floor surface on human postural stability while standing. Ten subjects were asked to stand quietly on the surface with two angles of inclination ($0^{\circ}$ and $5^{\circ}$), two contamination conditions (dry and oil-contaminated), and three commercial floor materials (ceramic tile, coated wood, and vinyl tile). During each trial, a force plate with data acquisition systems was used to collect subject's center of pressure (COP) position. Measured COPs were then converted into the length of postural sway path in both subject's anterior-posterior (AP) and medio-lateral (ML) axis. Results showed that the length of sway path in ML axis was significantly affected by the angle of inclination and the type of floor material. The sway length was increased significantly at the inclination angle of $5^{\circ}$ and on the vinyl tile, respectively. The contamination condition, however, did not significantly affect the postural sway length in both AP and ML axis. The results imply that a proper treatment of floor surface and material is critical to preserving postural balance while standing.