• Title/Summary/Keyword: H.P Pump

Search Result 155, Processing Time 0.029 seconds

Development of Synthetic-Jet based micro air pump for BOP system of mobile fuel cell (모바일 연료전지 BOP를 위한 Synthetic-Jet 기반 마이크로 에어펌프 개발)

  • Kim, K.S.;Choi, J.P.;Koo, B.S.;Jang, J.H.;Seo, Y.H.;Kim, B.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.247-251
    • /
    • 2008
  • This paper presents a micro air pump actuated by PZT actuator (synthetic jet actuator) for air supply for micro fuel cells. The synthetic jet actuators are usually created by a traditional PZT-driven actuator, which consists of a small cylindrical cavity, in/outlet channel and PZT diaphragms. To design the micro air pump, a numerical analysis has been conducted for flow characteristics with respect to various geometries. A prototype of the micro air pump, with a size of $mm{\times}mm{\times}mm$, was fabricated by PDMS replication process and was conducted performance test. To control the PZT actuator, we used the SP4423 micro chips that can be amplified input voltage to reduce the controller size and the power consumption. With a voltage of 3V at 100Hz, the air pump's pumping pressure is 600pa and its power consumption is only 0.1mW.

  • PDF

A Study on the Reactor Design of Solid-Solid-Gas Chemical Heat Pump System (고체-고체-기체 화학 열펌프 시스템의 반응기 설계에 관한 연구)

  • Kim, S.J.;Lee, T.H.;Neveu, P.;Choi, H.K.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.406-416
    • /
    • 1994
  • In this study the reactor design procedure and method of solid-solid-gas chemical heat pump system using STELF technology were investigated. For manufacturing IMPEX block which is the kernel of reactor, proper salt pair should be selected, and equilibrium temperature drop and COP should be examined for selected salt pair. Moreover, apparent density, residual porosity, and graphite ratio should be calculated to give minimum block volume and mass, and maximum energy density without causing heat and mass transfer problems. Since heat exchange area can be changed with operating condition, reactor diameter, length, and stainless steel thickness should be decided for desired specifications. These procedure and method were applied to the case study of 6kW cold production and 8 hours storage capacity reactor.

  • PDF

Development of Synthetic Jet Micro Air Pump (Synthetic Jet 마이크로 에어펌프의 개발)

  • Choi, J.P.;Kim, K.S.;Seo, Y.H.;Ku, B.S.;Jang, J.H.;Kim, B.H.
    • Transactions of Materials Processing
    • /
    • v.17 no.8
    • /
    • pp.594-599
    • /
    • 2008
  • This paper presents a micro air pump based on the synthetic jet to supply reactant at the cathode side for micro fuel cells. The synthetic jet is a zero mass flux device that converts electrical energy into the momentum. The synthetic jet actuation is usually generated by a traditional PZT-driven actuator, which consists of a small cylindrical cavity, orifices and PZT diaphragms. Therefore, it is very important that the design parameters are optimized because of the simple configuration. To design the synthetic jet micro air pump, a numerical analysis has been conducted for flow characteristics with respect to various geometries. From results of numerical analysis, the micro air pump has been fabricated by the PDMS replication process. The most important design factors of the micro air pump in micro fuel cells are the small size and low power consumption. To satisfy the design targets, we used SP4423 micro chip that is high voltage output DC-AC converter to control the PZT. The SP4423 micro chips can operate from $2.2{\sim}6V$ power supply(or battery) and is capable of supplying up to 200V signals. So it is possible to make small size controller and low power consumption under 0.1W. The size of micro air pump was $16{\times}13{\times}3mm^3$ and the performance test was conducted. With a voltage of 3V at 800Hz, the air pump's flow rate was 2.4cc/min and its power consumption was only 0.15W.

An Analysis of the Water Supply System with Pressurizing Tank (가압탱크를 이용한 급수시스템의 해석 및 최적화 연구)

  • Lee, T.W.;Kim, T.H.;Choi, D.H.;Kim, S.D.;Kim, J.P.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.93-102
    • /
    • 1994
  • It is the goal of this study to provide the essential data for design and operation of optimum water supply system. Experimental and theoretical analyses have been conducted for various parameters, for example, volume and air percent of pressurizing tank, pump speed and pressure range inside tank, etc. Pressure inside tank with time, flow rate, energy consumption rate and pump operation time have been obtained for design and operating parameters to optimize the components and to establish the operating method of system, and therefore to contribute to the development of technology from a point of view of the improvement of quality, the enhancement of system efficiency and the reduction of construction cost.

  • PDF

On-line Measurement of Buffer Capacity of a Fermentation medium and Estimation of Organic Aicd Production (발효배지의 완충용량의 온라인 측정 및 유기산 생산 추정)

  • Hur, Won;Jung, Yoon-Keun
    • KSBB Journal
    • /
    • v.13 no.4
    • /
    • pp.461-467
    • /
    • 1998
  • A fermentation system was supplemented with a device for the measurement of the durations of alkali pump feeding for automatic pH control and an A/D convertor for precise monitoring of pH value by computer. A software program was developed to measure buffer capacities from the pH signal and the pH control signal during fermentation. By measuring the buffer capacity on-line, levels of acetic acid were estimated by a software sensor using pH signal in a fermentation process of E.coli growing in a minimal medium. The measured values of acetic acid showed correlation to those of estimated by the software sensor. Lacitic acid production was also successfully estimated by the values of buffer capacities measured on-line.

  • PDF

Transport of Metal Ions Through the Crosslinked Chitosan Membrane (가교 Chitosan막에 의한 금속 이온의 투과 특성)

  • Kim, Chong-Bae
    • Applied Chemistry for Engineering
    • /
    • v.4 no.2
    • /
    • pp.416-422
    • /
    • 1993
  • In order to prepare high performance polymeric membrane, the crosslinked chitosan(C. Chitosan)membrane was prepared, the transport and the selective separation of the metal ions through the membrane were investigated. It was observed that the transport rates of the metal ions through the membrane increased according to the decreasing of the initial pH in downstream solution. Proton pump mechanism for this transport phenomenon was suggested. The transport selectivity is dependent on the selective adsorption resulting from the complex formation of chitosan with each metal ion. The separatin factor(${\alpha}_{Cu}{^{2+}}$) for the membrane was 9.5.

  • PDF

pH Measurements with a Microcantilever Array-Based Biosensor System

  • Hur, Shin;Jung, Young-Do
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.186-191
    • /
    • 2012
  • In this paper, we present a pH measurement method that uses a microcantilever-array-based biosensor system. It is composed of microcantilever array, liquid cell, micro syringe pump, laser diode array, position sensitive detector, data acquisition device, and data processing software. Four microcantilevers are functionalized with pH-sensitive MHA(mercaptohexadecanoic acid) as a probe, while three microcantilevers are functionalized with HDT(hexadecane thiol) as reference. We prepare PBS(phosphate buffered saline) solutions of different pH and inject them into the liquid cell with a predefined volumetric speed at regular time intervals. The functionalized mircocantilevers in the liquid cell deflect as a self-assembled monolayer on the microcantilever binds with probe molecules in the solution. The difference in deflection between the MHA-covered probe microcantilever and the HDT-covered reference microcantilever was used to compensate for thermal drift. The deflection difference clearly increases with increasing pH in the solution. It was shown that when the pH values of the PBS solutions are high, there were large variations in the deflection of microcantilevers, whereas there were small variations for low pH value. The experimental results show that the microcantilever array functionalized with MHA and HDT can detect pH value with good repeatability.

Studies on Osmotically Driven Drug Infusion Pump Under the Change in Body-Simulating Environment (인체 내부 환경 변화 모사에 따른 삼투압 기반 약물주입펌프의 기능 평가 연구)

  • Yoon, Chul Whan;Ahn, Jae Hong;Park, Doh;Lee, Jae Yeon;Park, Chun Gwon;Park, Min;Choy, Young Bin
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.291-295
    • /
    • 2015
  • Various types of implantable drug delivery devices have attracted significant attention for several decades to improve drug bioavailability and reduce side effects, thus enhancing therapeutic efficacy and patients' compliance. However, when implanted into the body, the devices may be influenced by the changes in physiological condition, such as temperature, pH or ionic concentration. Thus, the drug release rates could be also altered concurrently. Therefore, in this work, we employed an implantable ALZET$^{(R)}$ Osmotic Pump, which has been widely used to locally deliver various therapeutic agents and examined the effect of pH, temperature and ionic concentration on its drug release rate. For this, we performed in vitro cell tests to simulate the condition of local tissues influenced by the altered drug release rates, where we used diclofenac sodium as a model drug.

$Na^{+}$-dependent NADH:quinone Oxidoreductase in the Respiratory Chain of the Marine Bacterium Marinomonas vaga

  • Kim, Young-Jae;Park, Yong-Ha
    • Journal of Microbiology and Biotechnology
    • /
    • v.6 no.6
    • /
    • pp.391-396
    • /
    • 1996
  • The Gram-negative marine bacterium Marinomonas vaga, which requires 0.5 M NaCl concentration for optimal growth, is slightly halophilic. The growth of M vaga was highly resistant to the proton conductor, carbonyl cyanide m-chlorophenylhydrazone (CCCP) under alkaline pH conditions (pH 8.5) but very sensitive to CCCP under acidic pH conditions (pH 6.5). These results suggest that the respiratory chain-linked NADH oxidase system of M. vaga may lead to generation of a $Na^{+}$ electrochemical gradient. In order to examine the existence of $Na^{+}$-stimulated NADH oxidase in M. vaga, membrane fractions were prepared by the osmotic lysis method. The membrane-bound NADH oxidase oxidized both NADH and deamino-NADH as substrates and required $Na^{+}$ for maximum activity. The maximum activity of NADH oxidase was obtained at about pH 8.5 in the presence of 0.2 M NaCl. The site of $Na^{+}$-dependent activation in the NADH oxidase system was at the NADH:quinone oxidoreductase segment. The NADH oxidase and NADH:quinone oxidoreductase were very sensitive to the respiratory chain inhibitor, 2-heptyl-4-hydroxyquinoline-N-oxide (HQNO) in the presence of 0.2 M NaCl but highly resistant to another respiratory inhibitor, rotenone. Based on these findings, we conclude that M. vaga possesses the $Na^{+}$-dependent NADH:quinone oxidoreductase that may function as an electrogenic $Na^{+}$ pump.

  • PDF

The evaluation of Secondary pump vibration at Tongyoeng LNG recieving terminal in Korea Gas Corporation (한국가스공사 통영생산기지의 초저온 펌프의 진동 진단)

  • Koh, J.P.;Kim, J.H.;Hong, S.K.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1637-1641
    • /
    • 2003
  • Korea Gas Corporation(KOGAS) is a Liquified Natural Gas(LNG) supplier through out the Korea. LNG, which is imported wholly from foreign countries, is compressed 1/600 for easy transportation and is stored in a liquid state in the storage tanks at Incheon, Pyeongtaek and Tongyeong. At LNG receiving terminals, LNG is vaporized to natural gas before supplying to City Gas Consumer of Power Plant. The secondary pump is a equipment which compress LNG from 1- kgf/cm2 to 70 kgf/cm2. The secondary pump at Tongyeong LNG receiving terminal is consisted of two pumps in one underground PIT, and is connected to supporting structures. It is therefore expected that there is a vibration problem whit the pump and was found that high level vibration was occurred in a low frequency band($5^{\sim}10Hz$). In this paper, the vibration of secondary pump was analyzed, and the main cause of vibration was found out.

  • PDF