• Title/Summary/Keyword: H-field measurement

Search Result 454, Processing Time 0.031 seconds

A Study on the optical aspects of machine vision based dimensional measurement system (정밀 좌표측정용 머신비전 시스템의 광학적 해석에 관한 연구)

  • Lee, E.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.2
    • /
    • pp.149-163
    • /
    • 1994
  • A novel method of dimensional measurement using machine vision, which is called Landmark Tracking System, has been developed. Its advantages come form tracking only the bright, standard shaped "landmarks" which are made from retroreflective sheets. In the design of the LTS, it is essential to know the relationship between optical parameters and their influence on system performance. Such optical parameters include the brightness of landmark image, the illumination system design, and the choice of imaging optics. And the performance of retroreflective material also plays important role in the LTS performances. Influences of such optical parameters on LTS's dimensional measurement characteristics are investigated, with respect to the retroreflective material, the imaging optics, and the illumination system. Measuremtn errors due to parameter variations are also analyzed. Experiments are performed with a LTS prototype. Retroreflective characteristics are verified, and the LTS's measurement performances are measured in the form of repeatability and accuracy. Experimental results shgow that the LTS has repeatability better than 1/30,000 of a field of view(30 degrees), and accuracy better tha 1/3,000 of a field fo view.d fo view.

  • PDF

Development and Evaluation of the Upper & Lower side Ondol System in Apartment Houses (공동주택의 윗목/아랫목 온돌 제어시스템 개발 및 평가)

  • Cho, D.W.;Yu, K.H.;Yu, J.Y.;Jung, H.K.;Kim, Y.H.;Kim, S.H.;U., M.;Yang, I.H.
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.627-636
    • /
    • 2008
  • The purpose of this study is to develop the new korean district heating system for apartment houses. The upper & lower side ondol system with multi sensing control system was developed as a new korean district heating system and evaluated in 2 mock-up laboratories last winter. As a result of field measurement, when the load differences between perimeter zone and central zone are increased, the ondol system divided in the upper and lower side can be evaluated as the new ondol system with a capability for suppling proper heating energy for each zone. The user can have the freedom for changing an upper zone and a lower zone and controlling each temperature according to their needs.

  • PDF

Development of Measurement System of Very Fast Transient Overvoltage (과도급준파전압측정계의 개발에 관한 연구)

  • Lee, B.H.;Kil, G.S.;Chung, S.J.;Kim, J.N.;Lee, J,S.;Lee, H.H.;Kim, J.K.;Lee, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1523-1525
    • /
    • 1994
  • This paper describes a proposed very fast transient overvoltages(VFTO) measurement system suited for established gas insulated switchgear(GIS). The detecting system consists of a shield electrode connected to a buffer amplifier, and the transmission of the detected signal to an oscilloscope is made through an optical fiber. The bandwidth of the measurement system is 5 Hz to 30MHz. When determining the voltage dividing ratio by use of the commercial frequency voltage, the error is less than 0.5 %. Also, the data were obtained by the electric field probe and the high voltage probe, and their deviation for voltage dividing ratio were less than 1 %.

  • PDF

Static measurement of magnetostriction of FeCoGe/phenol composites (FeCoGe/페놀 복합체의 정적 자기변형 측정)

  • Park, K.I.;Na, S.M.;Shin, K.H.;Lim, S.H.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.577-580
    • /
    • 2003
  • The magnetostriction of FeCoGe/phenol composites, which is one of the magnetostrictive materials, measured at the external magnetic field. The measurement was carried out using the electrical-resistance strain gage, the wheaten's Bridge for eliminating the unnecessary voltage, and the lock-in-amp for signal amplification and noise filtering. When the external magnetic field was applied in the longitudinal the samples, the maximum strain of 120ppm was taken with regard to the 10wt.% phenol composite. This results indicate that the FeCoGe/phenol composites can be useful as an actuator because it has larger stain than the other solid state actuators such as piezo electric materials.

  • PDF

Profiles of electric and magnetic fields in the vicinity of 22.9[kV] Distribution Line (22.9[kV] 배전선로 주변의 전장과 자장의 분포)

  • Lee, Bok-H.;Gil, Hyoung-J.;Ahn, Chang-H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1653-1655
    • /
    • 1998
  • In this paper, measurement and analysis of ELF electric and magnetic fields in the vicinity of 22.9[kV] distribution line have been performed. The height of measuring point from the earth's surface was 1[m], and the distance between the device and the operator was more than 3[m]. The experiments have been carried out by lateral profile, and we have made use of FIELDS program for the sake of comparision the experimental data with the theoretical value. Electric and magnetic fields intensity were strong under a distribution line, and were inversely proportional to lateral distance. The profiles of electric field were M shape and those of magnetic field were $\cap$ shape. Electric and magnetic fields intensity were increased with increasing the measurement height.

  • PDF

Young's Modulus Measurement of FeCoGe/phenol Composites (FeCoGe/페놀 복합체의 영률 측정)

  • Park, K.I.;Kim, H.G.;Shin, K.H.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.107-109
    • /
    • 2003
  • The magnetostriction of FeCoGe/phenol composites is measured under the external magnetic field. A few Measurement are carried out by using the electrical-resistance strain gage, the Wheaton Bridge for eliminating the unnecessary voltage, the lock-in-amplifier for the signal amplification and noise filtering. When the external magnetic field is applied to the longitudinal direction against those samples which is the 10wt.% phenol in composites, the theoretical maximum strain of 120ppm is obtained. According to the larger strain than that of others solid state actuators and piezoelectric actuators. FeCoGe/phenol composites could be useful as an actuator.

  • PDF

A Measurement System for Two-Dimensional DC-Biased Magnetic Property

  • Enokizono, Masato;Takahashi, Syuichi;Ikariga, Atsushi
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.4
    • /
    • pp.143-148
    • /
    • 2002
  • Up to now, DC-biased magnetic properties have been measured in one dimension (scalar). However, scalar magnetic properties are insufficient to clarify DC-biased magnetic properties because scalar magnetic properties can only impossibly consider the phase difference between the magnetic flux density B vector and the magnetic field strength H vector. Thus the magnetic field strength H and magnetic flux density B in magnetic materials must be directly measured as a vector quantity (two-dimensional). This paper presents measurement system to clarify the two-dimensional DC-biased magnetic properties.

Magnetostriction and Young's Modulus Measurement of FeCoGeW/phenol Composites (FeCoGeW/페놀 복합체의 자왜 및 영률 측정)

  • Park, K.I.;Kim, H.G.;Shin, K.H.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.325-328
    • /
    • 2003
  • The magnetostriction of FeCoGeW/phenol composites is measured under the external magnetic field. A few Measurement are carried out by using the electrical-resistance strain gage, the Wheaton Bridge for eliminating the unnecessary voltage, the lock-in-amplifier for the signal amplification and noise filtering. When the external magnetic field is applied to the longitudinal direction against those samples which is the 10wt.% phenol in composites, the theoretical maximum strain of 120ppm is obtained. According to the larger strain than that of others solid state actuators and piezoelectric actuators. FeCoGeW/phenol composites could be useful as an actuator.

  • PDF

Analysis of Induced Magnetic Field Bias in LEO Satellites Using Orbital Geometry-based Bias Estimation Algorithm (궤도 기하학 기반 바이어스 추정기법을 이용한 저궤도 위성의 유도자기장 바이어스 분석)

  • Lee, S.H.;Yong, K.L.;Choi, H.T.;Oh, S.H.;Yim, J.R.;Kim, Y.B.;Seo, H.H.;Lee, H.J.
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.11
    • /
    • pp.1126-1131
    • /
    • 2008
  • This paper applies the Orbital Geometry-based Bias Estimation Algorithm to the magnetometer measurement data of KOMPSAT-1 and 2 and analyzes the induced magnetic field bias caused by the solar panels and electronics boxes in spacecraft bus. This paper reveals that the estimation and correction of the induced magnetic field bias copes with the aging process of magnetometer and makes it possible to carry on the satellite mission by extending its lifetime.