• Title/Summary/Keyword: H&R

Search Result 14,158, Processing Time 0.043 seconds

MICROLEAKAGE OF MICROFILL AND FLOWABLE COMPOSITE RESINS IN CLASS V CAVITY AFTER LOAD CYCLING (Flowable 및 microfill 복합레진으로 충전된 제 5급와동에서 load cycling 전,후의 미세변연누출 비교)

  • Kang, Suk-Ho;Kim, Oh-Young;Oh, Myung-Hwan;Cho, Byeong-Hoon;Um, Chung-Moon;Kwon, Hyuk-Choon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.142-149
    • /
    • 2002
  • Low-viscosity composite resins may produce better sealed margins than stiffer compositions (KempScholte and Davidson, 1988: Crim, 1989). Plowable composites have been recommended for use in Class V cavities but it is also controversial because of its high rates of shrinkage. On the other hand, in the study comparing elastic moduli and leakage, the microfill had the least leakage (Rundle et at. 1997) Furthermore, in the 1996 survey of the Reality Editorial Team, microfills were the clear choice for abfraction lesions. The purpose of this study was to evaluate the microleakage of 6 compostite resins (2 hybrids, 2 microfills, and 2 flowable composites) with and without load cycling. Notch-shaped Class V cavities were prepared on buccal surface of 180 extracted human upper premolars on cementum margin. The teeth were randomly divided into non-load cycling group (group 1) and load cycling group (group 2) of 90 teeth each. The experimental teeth of each group were randomly divided into 6 subgroups of 15 samples. All preparations were etched, and Single bond was applied. Preparations were restored with the following materials (n=15) : hybrid composite resin [Z250(3M Dental Products Inc. St. Paul, USA), Denfil(Vericom, Ahnyang, Korea)], microfill [Heliomolar RO(Vivadent, Schaan, Liechtenstein), Micronew(Bisco Inc. Schaumburg, IL, USA)], and flowable composite[AeliteFlo(Bisco Inc. Schaumburg, IL, USA), Revolution(Kerr Corp. Orange, CA, USA)]. Teeth of group 2 were subjected to occlusal load (100N for 50,000 cycles) using chewing simulator(MTS 858 Mini Bionix II system, MTS Systems Corp. Minn. USA). All samples were coated with nail polish 1mm short of the restoration, placed in 2% methylene blue for 24 hours, and sectioned with a diamond wheel. Enamel and dentin/cementum margins were analyzed for microleakage on a sclale of 0 (no leakage) to 3 (3/3 of wall). Results were statistically analyzed by Kruscal-Wallis One way analysis, Mann-Whitney U-test, and Student-Newmann-Keuls method. (p = 0.05) Results : 1. There was significantly less microleage in enamel margins than dentinal margins of all groups (p<0.05) 2. There was no significant between six composite resin in enamel margin of group 1. 3. In dentin margin of group 1, flowable composite had more microleakage than others but not of significant differences. 4. there was no significant difference between six composite resin in enamel margin of group 2. 5. In dentin margin of group 2, the microleakage were R>A =H=M>D>Z. But there was no significant differences. 6. In enamel margins, load cycling did not affect the marginal microleakage in significant degree. 7. In enamel margins, load cycling did affect the marginal microleakage only in Revolution. (p<0.05).

IN VITRO STUDY OF DEMINERALIZATION INHIBITION EFFECT AND FLUORIDE UPTAKE INTO ADJACENT TEETH OF LIGHT-CURED FLUORIDE-RELEASING RESTORATIVES (수종의 불소방출 수복재의 탈회억제 효과 및 불소침투에 관한 연구)

  • Kim, Song-Yi;Choi, Sung-Chul;Kim, Kwang-Chul;Choi, Yeong-Chul;Park, Jae-Hong
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.3
    • /
    • pp.288-297
    • /
    • 2010
  • The purpose of this study was to evaluate the effect of light cured fluoride-releasing materials on the inhibition of demineralization. In addition, the pattern of fluoride uptake of adjacent tooth structure was analyzed with EPMA. Eighty intact premolars were restored with $Filtek^{TM}$ Z250(control group, composite), Fuji Filling $LC^{TM}$(RMGI), Dyract $AP^{(R)}$ (compomer) and Beautifil II(giomer). Restored teeth were stored in distilled water for 30 days. Then sixty teeth(n=15) were exposed to demineralizing solution(pH 4.3). Demineralized teeth were bisected and polished. The specimens were observed with confocal laser scanning microscope. The depth of outer lesion and the thickness of inhibition zone were measured. Remained twenty teeth(n=5) were bisected for fluoride uptake analysis. The fluoride analysis were taken at enamel-restoration interface and dentin-restoration interface by electron probe micro-analyzer. The results are as follows: 1. The depth of outer lesion of Fuji Filling $LC^{TM}$ Dyract AP, Beautifil II was shallower than that of $Filtek^{TM}$ Z250 at the margin of restoration(p<0.05). 2. The thickness of caries inhibition zone of Fuji Filling $LC^{TM}$, Dyract AP, Beautifil II was greater than that of $Filtek^{TM}$ Z250 at the margin of restoration(p<0.05). 3. Fuji Filling $LC^{TM}$, Dyract AP, Beautifil II groups showed the greater fluoride uptake into enamel and dentine around restoration than $Filtek^{TM}$ Z250 group. 4. In dentin the difference of fluoride concentration were greater than in enamel, and Dyract AP showed the greatest fluoride concentration in dentin.

The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter (투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Lee, Na-Young;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.13-20
    • /
    • 2008
  • The flow rate measurements in a multi-phase flow pipeline were evaluated quantitatively by means of a clamp-on sealed radioisotope based on a cross correlation signal processing technique. The flow rates were calculated by a determination of the transit time between two sealed gamma sources by using a cross correlation function following FFT filtering, then corrected with vapor fraction in the pipeline which was measured by the ${\gamma}$-ray attenuation method. The pipeline model was manufactured by acrylic resin(ID. 8 cm, L=3.5 m, t=10 mm), and the multi-phase flow patterns were realized by an injection of compressed $N_2$ gas. Two sealed gamma sources of $^{137}Cs$ (E=0.662 MeV, ${\Gamma}$ $factor=0.326\;R{\cdot}h^{-1}{\cdot}m^2{\cdot}Ci^{-1}$) of 20 mCi and 17 mCi, and radiation detectors of $2"{\times}2"$ NaI(Tl) scintillation counter (Eberline, SP-3) were used for this study. Under the given conditions(the distance between two sources: 4D(D; inner diameter), N/S ratio: $0.12{\sim}0.15$, sampling time ${\Delta}t$: 4msec), the measured flow rates showed the maximum. relative error of 1.7 % when compared to the real ones through the vapor content corrections($6.1\;%{\sim}9.2\;%$). From a subsequent experiment, it was proven that the closer the distance between the two sealed sources is, the more precise the measured flow rates are. Provided additional studies related to the selection of radioisotopes their activity, and an optimization of the experimental geometry are carried out, it is anticipated that a radioisotope application for flow rate measurements can be used as an important tool for monitoring multi-phase facilities belonging to petrochemical and refinery industries and contributes economically in the light of maintenance and control of them.

Effect of Implant Types and Bone Resorption on the Fatigue Life and Fracture Characteristics of Dental Implants (임플란트 형태와 골흡수가 임플란트 피로 수명 및 파절 특성에 미치는 효과에 관한 연구)

  • Won, Ho-Yeon;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.121-143
    • /
    • 2010
  • To investigate the effect of implant types and bone resorption on the fracture characteristics. 4 types of Osstem$^{(R)}$Implant were chosen and classified into external parallel, internal parallel, external taper, internal taper groups. Finite elements analysis was conducted with ANSYS Multi Physics software. Fatigue fracture test was performed by connecting the mold to the dynamic load fatigue testing machine with maximum load of 600N and minimum load of 60N. The entire fatigue test was performed with frequency of 14Hz and fractured specimens were observed with Hitachi S-3000 H scanning electron microscope. The results were as follows: 1. In the fatigue test of 2 mm exposed implants group, Tapered type and external connected type had higher fatigue life. 2. In the fatigue test of 4 mm exposed implants group, Parallel type and external connected types had higher fatigue life. 3. The fracture patterns of all 4 mm exposed implant system appeared transversely near the dead space of the fixture. With a exposing level of 2 mm, all internally connected implant systems were fractured transversely at the platform of fixture facing the abutment. but externally connected ones were fractured at the fillet of abutment body and hexa of fixture or near the dead space of the fixture. 4. Many fatigue striations were observed near the crack initiation and propagation sites. The cleavage with facet or dimple fractures appeared at the final fracture sites. 5. Effective stress of buccal site with compressive stress is higher than that of lingual site with tensile stress, and effective stress acting on the fixture is higher than that of the abutment screw. Also, maximum effective stress acting on the parallel type fixtures is higher. It is careful to use the internal type implant system in posterior area.

Hepatotoxicity of Rifampicin and Pyrazinamide Treatment Excluding Isoniazid (Isoniazid를 제외한 Rifampicin과 Pyrazinamide 병합치료의 간독성 빈도)

  • Choi, Ik Su;Park, I-Nae;Hong, Sang-Bum;Oh, Yeon-Mok;Lim, Chae-Man;Lee, Sang Do;Koh, Younsuck;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong;Shim, Tae Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.1
    • /
    • pp.38-43
    • /
    • 2006
  • Background : Even though two-month rifampicin (RMP, R) and pyrazinamide (PZA, P) treatment has some advantages over isoniazid (INH, H) treatment for latent tuberculosis infection (LTBI), it was withdrawn from the list of treatment regimens for LTBI because of reported cases of severe hepatotoxicity. The purpose of this study was to estimate the frequency of hepatotoxicity of RMP and PZA treatment excluding INH in a Korean population. Method : TIn order to recruit patients who were prescribed RMP and PZA excluding INH, 256 INH-resistant tuberculosis patients were investigated through retrospective medical record analysis. A standard four-drug regimen was changed to a RMP/PZA-containing regimen excluding INH in 64 patients (RZ+ group). In the same study period, 146 patients who were prescribed an INH/RMP/PZA-containing standard regimen were randomly selected as a control (HRZ+ group). Clinical characteristics including liver diseases and the frequency of drug-induced hepatitis were compared between the RZ+ and HRZ+ groups. Result : The mean age of patients in the RZ+ group was 50.2 (${\pm}16.2$) and the male-to-female ratio was 36:28. The frequency of underlying liver diseases was 10.9% (7/64), which was not significantly different from that of the HRZ+ group (4.1%, 6/146). Even though the treatment duration of RZ+ ($5.5{\pm}4.8months$) was longer that than that of HRZ+ ($2.7{\pm}2.3months$), the frequency of toxic hepatitis was not significantly different between RZ+ and HRZ+ groups, 3.5% (2/57) and 7.1% (10/140), respectively. Conclusion : Hepatotoxicity was mild and occurred in a minor proportion of patients in a Korean population prescribed an RMP/PZA-containing regimen. A future prospective study including more patients is needed.

A Study on the Hydraulic Characteristics of Rashig Super-Ring Random Packing in a Counter-Current Packed Tower (역류식 충전탑에서 Raschig Super-ring Random Packing의 수력학적 특성에 대한 연구)

  • Kang, Sung Jin;Lim, Dong-Ha
    • Clean Technology
    • /
    • v.26 no.2
    • /
    • pp.102-108
    • /
    • 2020
  • In recent years, packed column has been widely used in separation processes, such as absorption, desorption, distillation, and extraction, in the petrochemical, fine chemistry, and environmental industries. Packed column is used as a contacting facility for gas-liquid and liquid-liquid systems filled with random packed materials in the column. Packed column has various advantages such as low pressure drop, economical efficiency, thermally sensitive liquids, easy repairing restoration, and noxious gas treatment. The performance of a packed column is highly dependent on the maintenance of good gas and liquid distribution throughout a packed bed; thus, this is an important consideration in a design of packed column. In this study, hydraulic pressure drop, hold-up as a function of liquid load, and mass transfer in the air, air/water, and air-NH3/water systems were studied to find the geometrical characteristic for raschig super-ring experiment dry pressure drop. Based on the results, design factors and operating conditions to handle noxious gases were obtained. The dry pressure drop of the random packing raschig super-ring was linearly increased as a function of gas capacity factor with various liquid loads in the Air/Water system. This result is lower than that of 35 mm Pall-ring, which is most commonly used in the industrial field. Also, it can be found that the hydraulic pressure drop of raschig super-ring is consistently increased by gas capacity factor with various liquid loads. When gas capacity factor with various liquid loads is increased from 1.855 to 2.323 kg-1/2 m-1/2 S-1, hydraulic pressure drop increases around 17%. Finally, the liquid hold-up related to packing volume, which is a parameter of specific liquid load depending on gas capacity factor, shows consistent increase by around 3.84 kg-1/2 m-1/2 S-1 of the gas capacity factor. However, liquid hold-up significantly increases above it.

Effect of Various Forms of Floor System on Performance of Meat-type Duck and Environments of Duck House (오리사 바닥 형태가 육용오리의 생산성 및 사육환경에 미치는 영향)

  • Bang, Han-Tae;Kim, Dong-Woon;Hwangbo, Jong;Na, Jae-Cheon;Kang, Hwan-Ku;Kim, Min-Ji;Mushtaq, M.M.H.;Parvin, R.;Choi, Hee-Chul;Lee, Sang-Bae;Kang, Min;Kim, Ji-Hyuk
    • Korean Journal of Poultry Science
    • /
    • v.40 no.3
    • /
    • pp.253-262
    • /
    • 2013
  • This experiment was conducted to investigate the effects of floor type and heating system on performance, housing environment and health status of ducks reared in three types of duck house (OD : Open floor house-Direct heating system, OF : Open floor house-Floor heating system and LD : Loft type house-Direct heating system). In OF treatment, PVC pipes were installed for heating under concrete floor and covered with litter. In LD treatment, plastic mesh was installed 50 cm above the floor so that duck's droppings can pass through it. Each treatment had four replicates of 25 birds (Cherry Valley duck breed) per pen. There were no significant differences in weight gain and feed intake of ducks for 6 weeks among all treatments. However, feed conversion ratio in LD was significantly higher (p<0.05) than that in OF. No differences were found in carcass charac- teristics, with the exception of abdominal fat weight where OF were higher than the others. Concentrations of $CO_2$ and $NH_3$ gas in OD were higher than those of OF and LD at 3, 4 and 5 weeks. Moisture content in litter of OF was lower than that of OD. In contrast, the amount of dust in the air was higher in OF than in OD. The amount of fuel used for 6 weeks in LD was lower about 21% than that in OD. Some of unusual symptoms were observed in open floor house and loft type house, such as lying, spraddle legged, twisted ankle and legs, wounded sole, or etc. No components of leukocyte and erythrocyte of blood were significantly different among all treatments. The results of this experiment showed that OF and LD systems had no positive effects on performance of meat type commercial duck. However, there were some positive effects of certain house type for the improvement of environmental condition in duck house for hygienic production. In the future, more research on the effect of various facilities and systems for duck house is needed.

The Effect of Non Magnetic ion Substitution for the FeCr2-xMxS4(M=Ga, In) by Mossbauer Spectroscopy (비자성 이온 Ga, In이 치환된 유화물 스피넬의 뫼스바우어 분광학 연구)

  • Son, Bae-Soon;Kim, Sam-Jin;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.1
    • /
    • pp.6-10
    • /
    • 2006
  • The sulphur spinel $FeCr_{2-x}M_xS_4$(M=Ga, In) have been studied with Mossbauer spectroscopy, x-ray diffraction (XRD), and vibrating sample magnetometer. The XRB patterns for samples $FeCr_{2-x}M_xS_4$(M=Ga, In: x=0.1, 0.3) reveal a single phase, which the Ga and In ions are partially occupied to the tetrahedral (A) site. The Neel temperature for the Ga substituted samples increases from 180 to 188 K, with increase from x=0.1 to 0.3. While, it decreases from 173 to 160 K, for the In substituted samples of the x=0.1 and 0.3, respectively. The Mossbauer spectra were collected from 4.2 K to room temperature. We have analyzed the Mossbauer spectra using eight Lorentzian lines fitting method for the $FeCr_{2-x}In_xS_4$(x=0.1) at 4.2 K, yielding the 1311owing results; $H_{hf}=146.0kOe,\;{\Delta}E_Q=1.88mm/s,\;\theta=36^{\circ},\;\phi=0^{\circ},\;\eta=0.6$, and R=1.9. The Ga ions enter into the both sites octahedral (B) and tetrahedral (A), simultaneously the same amounts of Fe ions migrate from the A to the B site, this result is an agreement with XRD results, too. The ${\Delta}E_Q$ of the A and B site in Mossbauer spectra of the samples $FeCr_{2-x}Ga_xS_4$(x=0.3) are 0.83 and 2.94mm/s, respectively. While they are 0.56 and 2.36mm/s for the $FeCr_{2-x}In_xS_4$(x=0.3). It is noticeable that the ${\Delta}E_Q$ for the Ga doped samples are larger than that of the corresponding In doped samples, in spite of the larger ionic radius for In ions. The bond lengths of Cr-S, for the Ga and In doped samples (x=0.3) are found to be 2.41 and $2.43\;{\AA}$, respectively. We interpret that the larger covalence effect from the smaller bond length induces a large asymmetric charge distribution. Finally, it gives a large quadrupole interaction.

Prediction Model of Weed Population in Paddy Fields - II. Simple Prediction Method of Weed Population and Prediction Model of Weed Species (논 잡초(雜草) 발생예측(發生豫測) 모델 개발연구(開發硏究) - II. 간역(簡易) 잡초발생(雜草發生) 예측법(豫測法) 및 잡종별(雜種別) 예측(豫測)모델)

  • Lee, Han-Gyu;Lee, I.Y.;Ryu, G.H.;Lee, J.O.;Lee, E.J.
    • Korean Journal of Weed Science
    • /
    • v.14 no.3
    • /
    • pp.163-170
    • /
    • 1994
  • The experiment was conducted in 1993 to find out a simple prediction method of weeds and to make the prediction models of weeds in paddy fields. The annuals producing fine seeds were apt to emerge at sampling soil only, on the contrary the perennials and the annuals producing large seeds tended not to emerge at sampling soil due to the miss of seeds at sampling. There was no appropriate regression between a total number of weeds emerged at sampling soil and that of weeds occurred in fields. The important annual weeds occurring in fields were able to predict by the number of weeds emerged at sampling soil, but it was difficult to predict the important perennial weeds. In case of Bidens tripartita producing large seeds and Eleocharis kuroguwai producing large tubers, the prediction coefficients were high as above 1.0, and that of Echinochloa crus-galli and Sagittaria pygmaea were comparatively high as 0.175 and 0.172, respectively. However the coefficients of the other weeds were much low as below 0.08. The prediction models for 9 species were made. The model of six species including E. crus-galli, M. vaginalis, R. indica, B. tripartita, E. triandra and S. pygmaea were linear regression with high significance, however that of 3 species including C. difformis, S. juncoides and E. kuroguwai were curve regression with high significance.

  • PDF

Weed Occurrence and Yield of Rice in Transplanting Rice Culture with Paper Mulching (종이멀칭 이앙재배에서 잡초발생과 벼의 생육 및 수량)

  • Lee, B.W.;Cui, R.X.;Lee, H.L.
    • Korean Journal of Weed Science
    • /
    • v.17 no.4
    • /
    • pp.368-374
    • /
    • 1997
  • Investigated ware the decomposition of mulch paper, weed occurrence, and rice growth and yield in transplanting rice culture with paper mulching in 1996 and 1997. The mulch paper were developed from domestic old corrugated container. In the experiment of 1996 where 25 percent of nitrogen fertilizer was applied as tillering fertilizer at 15 days after transplanting, it took about 28 to 40 days for the mulch paper to reach 50 percent decomposition according to types of mulch paper and fertilizer amount. The decomposition was faster in 18kg N/10a fertilization plot than in 12kg N/10a fertilization plot, and slower in the mulch paper treated with polyamidepolyamine epichlorohydrin resin(PPE) for the reinforcement of wet strength than in the mulch paper without PPE. In the experiment of 1997 where nitrogen fertilizer was not applied at tillering stage and instead 70 percent of nitrogen fertilizer was supplied as basal fertilizer, it took more than 42 days for the mulch paper(PPF treated) to reach 50 percent decomposition. Paper mulching was found to be very effective in controlling the paddy weeds at early stage of rice growth, but the efficacy, of weed control decreased especially in the mulch paper without PPE at later stage of rite growth due to the occurrence of Ludwigia prostrata in 1996. Few weeds occurred even in non-mulched plot without herbicide in 1997, rending difficulties in evaluating the efficacy of mulch paper in weed control, However, it could be deduced from the durability of mulch paper that paper mulching would have had sufficient efficacy of weed control. Rice yield was only 185kg/10a in the plot without mulching and weed control, but 657kg/10a and 771kg/10a in the paper(PPE treated) mulching plot with 12kgN/10a and 18kgN/10a, respectively, in 1996. The paper mulching plot showed rice yield similar to the weed control plot with herbicide in 1997. It would be concluded that paper mulching could ensure effective weed control and as high yield as the conventional rice cultivation with herbicidal weed control if the corresponding amount of basal nitrogen fertilizer is increased instead of omitting the nitrogen fertilizer at tillering stage.

  • PDF