• Title/Summary/Keyword: Gy2

Search Result 2,797, Processing Time 0.026 seconds

In Tomotherapy, for the Maintenance of Body Temperature due to Substance Use, Changes in Dose Assessment in the Organization (TOMO 치료 시 체온 유지를 위한 물질 사용에 따른 조직 내 선량 변화 평가)

  • Hwang, Jae-Woong;Jeong, Do-Hyeong;Kim, Dae-Woong;Yang, Jin-Ho;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.131-134
    • /
    • 2010
  • Purpose: TOMO therapy treatment for a relatively long run Beam time and temperature-sensitive detector, such as CT clinics in optimal temperature ($20~21^{\circ}$) to maintain a constant temperature in addition to its own Chamber Cooling system is activating. TOMO This clinic has been reduced in the patients' body temperature to keep the sheets and covers over the treated area. Therefore, these materials for any changes in the organization gives the dose were analyzed. Materials and Methods: To compare changes in the organization Dose Phantom cheese (Cheese Phantom) were used, CT-simulation taking the center point of the cheese phantom PTV (Planning Target Volume, treatment planning target volume) by setting Daily dose 200 cGy, 3 meetings planned treatment. PTV, PTV +7 cm, PTV +14 cm, the total count points on the phantom using the Ion chamber cover without any substance to measure the dose, and one of the most commonly used treatment, including the frequently used four kinds of bedding materials (febric 0.8 mm, gown 1.4 mm, rug, 3.3 mm, blanket 13.7 mm) and covered with a phantom and the dose measured at the same location were analyzed 3 times each. Results: PTV, PTV +7 cm, PTV +14 cm from the point of any substance measured in the state are covered with four kinds of materials (fabric, gown, rug, blanket) was measured in the covered states and compares their results, PTV respectively -0.17%, -0.44%, -0.53% and -0.9% change, PTV +7 cm, respectively -0.04%, +0.07%, +0.06%, +0.07%, were changed, PTV +14 cm, respectively 0%, -0.06%, -0.02%, +0.6%, respectively. Conclusion: These results TOMO treatment to patients to maintain their body mass by using PTV thickness of the material decreased in proportion to. PTV +7 cm, but showed slight changes in the point, PTV +14 cm at the point of the dose was increased a little. Sejijeom all the difference in treatment tolerance ${\pm}3%$ range, this is confirmed in the coming treatment will not affect the larger should be considered.

  • PDF

Effect of Irradiation and Packaging Methods on the Oxidation of Cholesterol in Raw and Cooked Chicken Leg Meat (방사선 조사 및 포장방법이 생계육 및 조리계육의 콜레스테롤 산화에 미치는 영향)

  • Lee, J.I.;Shin, T.S.;Jin, S.K.;Kim, I.S.;Kim, Y.H.;Joo, S.T.;Park, G.B.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.825-834
    • /
    • 2003
  • Chicken thigh from a retail market were used as experimental samples. Some chicken samples of raw state were packaged with PVDC at an aerobic and vacuum condition. The other samples were cooked until core temperature arrived at 70$^{\circ}C$ and then packaged immediately in the same way of raw samples. After samples were irradiated by electron beam at 6 kGy, they were stored in a refrigerator. Identification and quantity of cholesterol oxides were made at 0 and 7 days of storage, respectively. During the early stage of storage, 7$\beta$-hydroxycholesterol, $\alpha$,$\beta$-epoxide, cholestanetriol and 7-ketocholesterol were produced from the raw meat samples, and the production of these chemicals were significantly higher(P〈0.05) from the samples with aerobic packaging than those with vacuum packaging. With storage time, 7$\alpha$-hydroxycholesterol, 6-ketocholesterol and some other chemicals, which were not found during the early stage of storage, were found. Also, the formation of these chemicals were significantly increased(P〈0.05) with storage time. Cholesterol and lipid oxidation products of cooked meat after irradiation and irradiated meat after cooking were significantly increased(P〈0.05) with storage time for all treatments, and vacuum packaging results in showed significantly lower value(P〈0.05) than aerobic packaging. Summarizing the aforementioned results, it was found that the formation of cholesterol and lipid oxides and lipid oxidation was more easily affected by packaging condition than irradiation.

Results of Postoperative Radiation Therapy of Rectal Cancers - with the Emphasis of the Overall Treatment Time - (직장암의 수술 후 방사선치료의 성적 - 예후 인자와 전체 치료기간이 미치는 영향에 관한 고찰 -)

  • Kim Joo-Young;Lee Myung-Hag;Lee Kyu-Chan
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.303-310
    • /
    • 1998
  • Purpose : To evaluate the results of the treatment of locally advanced but resectable rectal cancers and to analyze prognostic factors. especially with the emphasis on the treatment time factor. Materials and Methods : There were 71 patients with rectal cancer who had been treated by curative surgical procedure and postoperative radiotherapy from August 1989 to December 1993. The minimum follow up period was 24 months and the median follow-up was 35 months Radiation therapy had been given by 6 MV linear accelerator by parallel opposing or four-box portals. Whole pelvis was treated up to 5040 cGy in most cases. Systemic chemotherapy had been given in 94$\%$ of the patients, mostly with 5-FU/ACNU regimen. Assessment for the overall and disease-free survival rates were done by life-table method and prognostic factors by Log-Rank tests. Results : Five-year overall survival, disease-free survival were 58.8$\%$ and 57$\%$, respectively. Two-year local control rate was 76.6$\%$. Stage according to Modified Astler-Coller (MAC) system, over 4 positive lymph nodes, over 6weeks interval between definitive surgery and adjuvant radiotherapy and over 7 days of interruption during radiotherapy period were statistically significant, or borderline significant prognostic factors. Conclusion : The treatment results of patients with rectal cancers are comparable to those of other large institutes. The treatment results for the patients with bowel wall penetration and/or positive regional lymph nodes were still discouraging for their high local recurrence rate for the patients with MAC 'c' stage diseases and high distant metastases rate even for the patients with node-negative diseases. Maybe more effective regimen of chemotherapy would be needed with proper route and schedule. To maximize postoperative adjuvant treatment. radiotherapy should be started at least within 6 weeks after surgery and preferably as soon as wound healing is completed. Interruption of treatment during radiotherapy course affects disease-free survival badly, especially if exceeds 7 days. So, the total treatment period trout definitive surgery to the completion of radiotherapy should be kept as minimal as possiable.

  • PDF

Change of Frequency of Chromosome Aberration by Time Interval after Radiation Therapy (방사선 치료후 시간경과에 따른 염색체이상 빈도의 변화)

  • Kim, Mi-Sook;Yi, Chun-Ja;Ha, Sung-Whan;Song, Myung-Jae;Kim, Hee-Jeun
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.1
    • /
    • pp.51-68
    • /
    • 1994
  • It is good method to use frequency of chromosome aberration in Lymphocytes for a biological dosimetry in cases of accidental exposure to radiation. But in cases of past exposure, biological dosimetry is limited because the frequency of aberration decreases by time after exposure. To provide a basic data for estimation of past radiation exposure, the changing pattern of frequency of unstable chromosome aberration by time interval after exposure was studied. Observation was made on peripheral lymphocytes of 41 blood samples from 20 patients treated for uterine cervical carcinoma and endometrial carcinoma. The patients received 50.4Gy radiation to whole pelvis. Elapsed times after the completion of radiation therapy were 1 day, 3, 6, 9, 12, 24, 52, 104, 156, 208, 260 and 520 weeks. All the blood sample were microcultured. The Ydr, Qdr and Qdra were calculated from frequency of unstable aberration. Ydr did not decrease for 3 weeks after radiation therapy, and thereafter, decreased very rapidly and reached 0.05 at two years after radiation therapy and decreased very slowly until 5 years after radiation therapy. Relationship between unstable chromosome aberration and time interval after radiation therapy was described as $Ydr=0.259{\times}exp(-0.0429T)+0.0560{\times}exp(-0.00106T)$ (time in weeks) Qdr remained constant at 1.51 until 24 weeks after radiation therapy and then decreased to 1.17 at 52 weeks. Therafter, it did not change. Qdra remained constant at 1.10 for 12 weeks after radiation therapy and decreased to 0.81 at 52 weeks. Thereafter, it remained constant. Two superimposed exponential Ydr disappearance rate suggests that it is possible to calculate the past exposure dose. When the elapsed time after exposure is short, Qdr and Qdra are useful papameters for biological dosimetry for past radiation exposure.

  • PDF

Effects of Gamma Irradiation on Antioxidant Properties and Physical Characteristics of Sargassum siliquastrum Water Extract (꽈배기 모자반 물 추출물의 항산화능과 물리적 특성에 대한 감마선 조사의 영향)

  • Kim, Ah-Ram;Song, Eu-Jin;Kim, Mi-Jung;Lee, So-Young;Kim, Koth-Bong-Woo-Ri;Kim, Jin-Hee;Kim, Seo-Jin;Hong, Yong-Ki;Park, Jin-Gyu;Kim, Jae-Hun;Lee, Ju-Woon;Byun, Myung-Woo;Ahn, Dong-Hyun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.3
    • /
    • pp.357-361
    • /
    • 2008
  • In this study, the antioxidant properties and physical characteristics of irradiated Sargassum siliquastrum water extract were evaluated. Samples were irradiated with $Co^{60}{\gamma}$-ray at doses ranging from 3 to 20 kGy. They were then analyzed to investigate antioxidant properties, including total phenolic compound content and DPPH (1,1-diphenyl-2-picrylhydrazyl) radical scavenging activity. In addition, physical properties such as viscosity and color were evaluated. The results demonstrated that total phenolic compound content and DPPH radical scavenging activity were significantly improved (p<0.05) by irradiation. In terms of physical properties, viscosity and color were reduced in the irradiated extracts as compared to non-irradiated samples. In conclusion, gamma irradiation improved the antioxidant properties of Sargassum siliquastrum water extract, improving its original weak point as a natural antioxidant when applied in the food industry.

Effect of Gamma-ray on Survival and Mutation Rates of Rooted Cuttings and Unrooted Cuttings in Rose (감마선 처리에 의한 장미 삽수의 발근 여부에 따른 생존율과 돌연변이 발생빈도)

  • Kim, Se Won;Lee, Hyo Jeong;Kim, Ye-Sol;Jo, Yeong Deuk;Ryu, Jai Hyunk;Kang, Si-Yong;Kim, Sang Hoon
    • Korean Journal of Breeding Science
    • /
    • v.49 no.3
    • /
    • pp.150-156
    • /
    • 2017
  • This study was carried out to compare the survival and mutation rates and mutation spectrum by gamma-irradiation on rooted and unrooted cuttings of three spray type ('Lovelydia', 'Yellowbabe', and 'Haetsal') and two standard type ('Vital' and 'Aqua') cultivars in roses. Two groups, rooted and unrooted cuttings were gamma-irradiated at 70Gy for 24 hours. The irradiated rooted and unrooted cuttings were planted in a greenhouse, and survival, mutation rates and mutation spectrum were investigated 30 weeks after planting, respectively. As a result, survival and mutation rates of gamma-ray irradiated plants were 16.4%~50.8% and 0~5.1% for unrooted cuttings, and 39.4%~55.1% and 0.7%~7.4% for rooted cuttings, respectively. In conclusion, both survival and mutation rates were a little higher on rooted cuttings than on unrooted cuttings. However, when only survived plants after gamma-ray irradiation were considered, mutation rates were 0~10% and 1.8%~14.1% for unrooted cuttings and rooted cuttings, respectively, showing no significant difference. In addition, diverse variations on color and number of petals or shape of flowers were detected both in plants from rooted and unrooted cuttings, which indicated that there was no significant difference in mutation spectrum between two groups.

p53 Mutations in Advanced Supraglottic Cancer (진행된 성문상부암에서 PCR-SSCP에 의한 p53의 변이 양상과 임상적 의의)

  • Hong Seong Eon;Kang Jin Oh;Baik Hyung Hwan;Yoon Kyung Sik
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.107-112
    • /
    • 2001
  • Purpose : To determine the prognostic significance of p53 mutations in advanced supraglottic cancer patients. Material and Methods : Twenty-six patients with pertinent tissue materials among 60 patients diagnosed as advanced supraglottic cancer in Kyung Hee university hospital and received total or partial laryngectomy followed by radiation therapy were enrolled. Immunohistochemical staining using DO7 monoclonal antibody was peformed. Tumor specimens were analyzed for p53 mutations in exons 5 through 8 by using PCR-SSCP analysis followed by DNA sequencing of all variants. Results : p53 mutations were present in 8 cases among 26 patiets. Mutations within exon 5 were 3 cases, exon 6 were 4 cases, and exon 7 was 1 case. Mean survival time was 70.2 months in patients without mutations, 61.3 months with mutations but there was no statistically significant differences (p=0.596). Mutations were $25\%$ in stage III and $36\%$ in stage IV but there was no statistically significant differences (p=0.563). Mutations were $25\%$ in lymph node negative group and $42\%$ in lymph node positive group but there was no statistically significant differences (p=0.437). Conclusion : The presence of p53 mutation detected by PCR-SSCP is not associated with survival, stage and lymph node status.

  • PDF

Dosimetry for Total Skin Electron Beam Therapy in Skin Cancer (피부암치료를 위한 전자선 전신피부 치료방법과 선량분포 측정)

  • Chu, Sung-Sil;Loh, John-Jk;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.107-113
    • /
    • 1992
  • Increasing frequency of skin cancer, mycosis fungoides, Kaposi's sarcoma etc, it need to treatment dose planning for total skin electron beam (TSEB) therapy. Appropriate treatment planning for TSEB therapy is needed to give homogeneous dose distribution throughout the entire skin surface. The energy of 6 MeV electron from the 18 MeV medical linear accelerator was adapted for superficial total skin electron beam therapy. The energy of the electron beam was reduced to 4.2 MeV by a $0.5\;cm\times90\;cm{\times}180\;cm$ acryl screen placed in a feet front of the patient. Six dual field beam was adapted for total skin irradiation to encompass the entire body surface from head to toe simultaneously. The patients were treated behind the acryl screen plate acted as a beam scatterer and contained a parallel-plate shallow ion chamber for dosimetry and beam monitoring. During treatment, the patient was placed in six different positions due to be homogeneous dose distribution for whole skin around the body. One treatment session delivered 400 cGy to the entire skin surface and patients were treated twice a week for eight consecutive weeks, which is equivalent to TDF value 57. instrumentation and techniques developed in determining the depth dose, dose distribution and bremsstrahlung dose are discussed.

  • PDF

Effects of Whole Body Irradiation on Morphine, DAMGO, DPDPE, U50,488H and $\beta$-endorphin-Induced Antinociception

  • Park, Tae-Won;Kim, Jin-Kyu;Jeong, Jae-Soo;Kim, Tae-Wan;Cho, Young-Kyung;Kim, Kyung-Nyun;Chung, Ki-Myung
    • International Journal of Oral Biology
    • /
    • v.37 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • Opioid receptors have been pharmacologically classified as ${\mu}$, ${\delta}$, ${\kappa}$ and ${\varepsilon}$. We have recently reported that the antinociceptive effect of morphine (a ${\mu}$-opioid receptor agonist), but not that of ${\beta}$-endorphin (a novel ${\mu}/{\varepsilon}$-opioid receptor agonist), is attenuated by whole body irradiation (WBI). It is unclear at present whether WBI has differential effects on the antinociceptive effects of ${\mu}-$, ${\delta}-$, ${\kappa}-$ and ${\varepsilon}$-opioid receptor agonists. In our current experiments, male ICR mice were exposed to WBI (5Gy) from a $^{60}Co$ gamma-source and the antinociceptive effects of opioid receptor agonists were assessed two hours later using the hot water ($52^{\circ}C$) tail-immersion test. Morphine and $D-Ala^2$, $N-Me-Phe^4$, Gly-olenkephalin (DAMGO), [$D-Pen^2-D-Pen^5$] enkephalin (DPDPE), trans-3,4-Dichloro-N-methyl-N-[2-(1-pyrrolidinyl)-cyclohexyl]-benzeneacetamide (U50,488H), and ${\beta}$-endorphin were tested as agonists for ${\mu}$, ${\delta}$, ${\kappa}$, and ${\varepsilon}$-opioid receptors, respectively. WBI significantly attenuated the antinociceptive effects of morphine and DAMGO, but increased those of ${\beta}$-endorphin. The antinociceptive effects of DPDPE and U50,488H were not affected by WBI. In addition, to more preciously understand the differential effects of WBI on ${\mu}-$ and ${\varepsilon}$-opioid receptor agonists, we assessed pretreatment effects of ${\beta}$-funaltrexamine (${\beta}$-FNA, a ${\mu}$-opioid receptor antagonist) or ${\beta}$-$endorphin_{1-27}$ (${\beta}$-$EP_{1-27}$, an ${\varepsilon}$-opioid receptor antagonist), and found that pretreatment with ${\beta}$-FNA significantly attenuated the antinociceptive effects of morphine and ${\beta}$-endorphin by WBI. ${\beta}$-$EP_{1-27}$ significantly reversed the attenuation of morphine by WBI and significantly attenuated the increased effects of ${\beta}$-endorphin by WBI. The results demonstrate differential sensitivities of opioid receptors to WBI, especially for ${\mu}-$ and ${\varepsilon}$-opioid receptors.

Evaluation of Dose Distribution Using Gafchromic $EBT^{(R)}$ Film (Gafchromic $EBT^{(R)}$ 필름을 이용한 선량분포의 평가)

  • Kang, Se-Sik;Ko, Seong-Jin;Jang, Eun-Sung
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.139-145
    • /
    • 2007
  • Dose evaluation for small field such as stereotactic radiosurgery was performed using $Gafchromic^{(R)}$ EBT film. Every film which irradiated 6MV photon beam was scanned and obtained the optical density(OD) by flat bed scanner after 24 hours of irradiation. This study compared dose from diode in water and Gafchromic $EBT^{(R)}$ film in acrylic phantom to verify the reliability of the film, and to evaluate the SRS in clinical dose distributions from calculation and measurement in the region of virtual target in humanoid and cylindrical phantoms were compared. The Gafchromic $EBT^{(R)}$ film was found to be linear up to 9Gy. The $D_{max}$ for 6 MV was measured at 1.5 cm from the surface by both of diode and the film. As the depth is deeper, the error was measured within $2{\sim}3%$ at $10{\sim}20\;cm$ depth. Comparing between distribution from calculation and measurement, we found that there is 5% error at 90% isodose line. We found that given dose could be measured accurately by using the phantoms. It was feasible to use the Gafchromic $EBT^{(R)}$ film in quality assurance of SRS.

  • PDF