• Title/Summary/Keyword: Gy2

Search Result 2,788, Processing Time 0.04 seconds

Effect of gamma irradiation on the morphological and physiological variation from In vitro individual shoot of banana cv. Tanduk (Musa spp.)

  • Abdulhafiz, Ferid;Kayat, Fatimah;Zakaria, Suhana
    • Journal of Plant Biotechnology
    • /
    • v.45 no.2
    • /
    • pp.140-145
    • /
    • 2018
  • Inducing genetic and morphological variation through conventional method is very difficult. Therefore, mutation induction through in vitro technology brings numerous advantages over the conventional breeding. Thus, the individual shoots (1 ~ 2 cm) were irradiated with gamma rays (10 ~ 70 Gy). The result revealed that the explants treated with higher doses (40, 50, 60, and 70 Gy) showed deleterious effects of ionizing radiation. The highest survival rate among ${\gamma}$ treated explants recorded was 71% in 10 Gy treatments while the lowest survivality was 15% in 70 Gy. Lethal dose 50% ($LD_{50}$) dose was found to be 33 Gy. In the in vitro condition, rooting reponse showed that increase in gamma irradiation dose resulted in the inhibition of root growth. Meanwhile, non-treated explants had the best rooting ability with the maximum number of root per explant (20) within a short period of time (6 days), with the highest root length of (15.1 cm). The longer period in rooting (12 days) and lowest number of root per explant (8) with shortest root length (10.1 cm) were recorded at 30 Gy treatment. The highest shoot length (13.6 cm) was observed at control treatment and the shortest shoot length (10.4 cm) was observed at 30 Gy. In the nursery, lowest leaf number (5) was observed at 30 Gy compared with other treatments. The highest chlorophyll content (49.8) was recorded at 10 Gy treated seedling. Irradiated explants with 10 Gy found to be superior over the control treatment and had positive effects in main growth parameters such as chlorophyll content.

Prenatal Deaths and External Malformations Caused by X-Irradiation during the Preimplantation Period of ddy Mice (임신 ddy Mice에서 착상전기 방사선 조사에 따른 산전 사망 및 외부 기형 발현)

  • Ro, Hee-Jeong;Choi, Ihl-Bhong;Gu, Yeun-Wh
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.233-243
    • /
    • 1998
  • Purpose : To evaluate the effects of X-irradiation on prenatal deaths, i.e., preimplantation deaths, embryonic deaths and fetal deaths, and on external malformations in precompacted preimplantation ddy mice Materials and Methods : Pregnant mice (n=85) obtained by limiting the mating time to from 6 to 9 A.M., were segregated into 11 groups. The first five groups (n=26) were irradiated with X-ray doses of 0.1 0.5, 0.75, 1.5, and 3 Gy, respectively, at 24 h post conception (p.c.) of the preimplantation Period. The second five (n=27) groups were irradiated at the same X-ray doses, respectively, but at 48 h p.c. of the preimplantation period. The last group (n=32) was the control group. The uterine contents were examined on the 18th day of gestation for prenatal deaths and external malformations. Results : 1) A statistically significant increase in preimplantation deaths with increasing dose was observed in the experimental groups irradiated at 24 h p.c. and in the groups irradiated at 48 h p.c., as compared to the control group. The threshold dose was close to 0.05 Gy and 0.075 Gy for the irradiations at 24 h p.c. and 48 h p.c. respectively. 2) A statistically significant increase in embryonic deaths with increasing dose was observed in all irradiation groups, except the group irradiated with a dose of 0.1 Gy at 48 h p.c.. 3) No fetal deaths were found in any experimental group. 4) In the experimental groups irradiated at 24 h p.c. anomalies increased with statistical significance, as compared with the control group : 2 exencephalies, 2 open eyelids, 3 anophthalmias, 2 cleft Palates, 2 gastroschisis, 1 abdominal wall defect. 1 leg defect, and 2 short tail anomalies: the threshold dose for external malformations was close to 0.2 Gy at 24 h p.c.. In the groups irradiated at 48 h p.c., 1 open eyelid and 2 short tail anomalies were observed, but there was no statistical significance in those malformations. Conclusion : The results of this study reveal that X-irradiation of precompacted preimplantation ddy mice causes not only preimplantation deaths and embryonic deaths but also external malformations. In addition, external malformations were observed in our experiments at diagnostic doses, including 0.1 and 0.5 Gy. For this reason, we recommend that irradiation should be avoided during the preimplantation period by applying Rugh's 10-day rule.

  • PDF

Effect of Electron Beam Irradiation on Microbial Qualities of Whole Black Pepper Powder and Commercial Sunsik (전자선 조사가 통후추 분말과 시판 선식의 미생물학적 안전성 및 품질에 미치는 영향)

  • Ko, Jong-Kwan;Ma, Yu-Hyun;Song, Kyung-Bin
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.308-311
    • /
    • 2005
  • Electron beam irradiation was applied to examine microbial safety and qualities of black pepper powder and commercial Sunsik. Whole black pepper powder and commercial Sunsik were irradiated at 2, 4, 8, 12, and 16 kGy. Microorganism contamination in black pepper powder and commercial Sunsik were significantly decreased by irradiation. Decimal reduction doses ($D_{10}\;value$) of total bacteria count in black pepper powder and commercial Sunsik were 5.32 and 1.56 kGy, respectively. $D_{10}\;value$ of yeast and mold were 2.54 and 2.14 kGy for black pepper powder and commercial Sunsik, respectively. Electron beam irradiation caused negligible changes in Hunter color L, a, and b values. Sensory evaluations of black pepper powder and commercial Sunsik showed no significant changes among samples. These results indicate electron beam irradiation improves microbial safety and qualities of black pepper powder and commercial Sunsik.

Effect of Radiation Dosage Changes on the Cell Viability and the Apoptosis Induction on Normal and Tumorigenic Cells (방사선의 선량변화가 수종의 정상세포와 종양세포주의 세포활성도와 apoptosis 유발에 미치는 영향)

  • Park In-Woo;Lee Sam-Sun;Heo Min-Suk;Choi Soon-Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.435-449
    • /
    • 1999
  • Purpose : The study was aimed to detect the differences in the cell viability and the apoptosis induction after irradiation on normal and tumorigenic cells. Materials and Methods : The study. that was generated for two human normal cells(RHEK, HGF-l) and two human tumor cells(KB. HT-1080). was tested using MTT assay at 1 day and 3 day after irradiation and TUNEL assay under confocal laser scanning microscope at 1 day after irradiation. Single irradiation of 0.5. 1, 2. 4. and 8Gy were applied to the cells. The two fractions of 1. 2. 4. and 8Gy were separated with a 4-hour time interval. The irradiation was done with 5.38Gy/min dose rate using Cs-137 irradiator at room temperature. Results and Conclusions : 1. In 3-day group. the cell viability of HGF-1 cell was significantly decreased at 2. 4 and 8Gy irradiation, the cell viability of KB cell was significantly decreased at 8Gy irradiation and the cell viability of HT-I080 cell was significantly decreased at 4 and 8Gy irradiation. 2. There was significant difference between RHEK and KB cell line in the cell viability of 3-day group at 8Gy irradiation. There was significant difference between RHEK and HGF-1 cell line in the cell viability of 3-day group at 4 and 8Gy irradiation. 3. There was a significantly decreased cell viability in 3-day group than those in 1-day group at 2. 4 and 8Gy on HGF-1 cell. at 4 and 8Gy on HT-I080 cell. at 8Gy on KB cell. 4. We could detect DNA fragmented cells only on KB cell. Number of apoptotic cells of KB cell was significantly increased at 4 and 8Gy irradiation. However, there was no correlation between cell viability and apoptosis. 5. On all 4 cell lines, there were no differences between single and split irradiation method in cell viability and apoptosis.

  • PDF

Evaluation of the Lens Absorbed Dose of MVCT and kV-CBCT Use for IMRT to the Nasopharyngeal Cancer Patient (비인두암 환자에 대한 세기조절 방사선치료 시 이용되는 MVCT와 kV-CBCT의 수정체 흡수선량 평가)

  • Choi, Jae Won;Kim, Cheol Chong;Park, Su Yeon;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.131-136
    • /
    • 2013
  • Purpose: Quantitative comparative evaluation of the difference in eye lens absorbed dose when measured by MVCT and kV-CBCT, though such a dose was not included in the original IMRT treatment plan for the nasopharyngeal cancer patient. Materials and Methods: We used CT (Lightspeed Ultra 16, General Electric, USA) against an Anderson rando phantom (Alderson Research Laboratories Inc, USA) and established the plan for tomotherapy treatment (Tomotherapy, Inc, USA) and linear accelerator treatment (Pinnacle 8.0, Philips Medicle System) for the achieved CT images on the same condition with the nasopharyngeal cancer patient treatment plan. Then, align the ther-moluminescence dosimeter (TLD100 Harshaw, USA) with the eye lens, shot the lens with Tomotherapy MVCT under 3 conditions (Fine, Normal, and Coarse), and shot both lenses with kV-CBCT under 2 conditions (Low Dose Head and Standard Dose Head) 3 times each. Results: When we analyzed the eye lens absorbed dose according to MVCT and kV-CBCT images by using both Tomotherapy and Pinacle 8.0, we achieved the following result; According to Tomotherapy MVCT, RT 0.8257 cGy in the Coarse mode, LT 0.8137 cGy, RT 1.089 cGy and LT 1.188 cGy in the Normal mode, and RT 2.154 cGy and LT 2.082 cGy in the Fine mode. According to Pinacle 8.0 kV-CBCT, RT 0.2875 cGy and LT 0.1676 cGy in the Standard Dose mode and RT 0.1648 cGy and LT 0.1212 cGy in the Low-Dose mode. In short, the MVCT result was significantly different from that of kV-CBCT, up to 20 times. Conclusion: We think kV-CBCT is more effective for reducing the amount of radiation which a patient is receiving during intensity modulated radiation treatment for other purposes than treatment than MVCT, when we consider the absorbed dose only from the viewpoint of image-guided radiation therapy. Besides, we understood the amount of radiation is too sensitive to the shooting condition, even when we use the same equipment.

  • PDF

Effect of irradiation on expression of clusterin in the rat salivary glands (방사선조사가 백서 타액선의 clusterin 발현에 미치는 영향)

  • O Gyu-Myeong;Choi Yong-Suk;Hwang Eui-Hwan;Lee Sang-Rae
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.33-40
    • /
    • 2006
  • Purpose : To investigate clusterin expression in the acini and ductal cells of rat submandibular glands after Co-60 gamma irradiation. Materials and Methods : The male Sprague-Dawley rats weighing approximately 250 gm were divided into control and experimental groups. The experimental group was irradiated with a single absorbed dose of 2, 5, 10, and 15 Gy on the head and neck region. All the rats were sacrificed at 1, 3, 7, 14, 21, and 28 days after irradiation. The specimens including the submandibular gland were sectioned and observed using a immunohistochemical method. Results : In the 2 Gy group, clusterin expression was similar to that of the control group at 1 day after irradiation and it was observed in the striated ductal cells at 3 days after irradiation. In the 5 Gy group, clusterin expression was observed in the striated ductal cells at 1 day after irradiation and gradually increased in the 10 and 15 Gy groups. In the 15 Gy group, clusterin expression was prominent in the striated ductal cells at 1 day after irradiation, but it gradually decreased with the experimental period. The destruction of the striated ductal cells was observed in the 2 Gy group at 21 days after irradiation and in the 5, 10, and 15 Gy groups at 7 days after irradiation. The destruction of the acinar cells was observed in the 2 Gy group at 28 days after irradiation and in the 5, 10, and 15 Gy groups at 14 days after irradiation. Conclusion : Clusterin expression was induced by low doses of irradiation and it appeared to be involved in the regulation of cellular response to irradiation.

  • PDF

The Combined Effect of Heat and Gamma Irradiation on the Inactivation of Selected Microorganisms Associated with Food Hygiene (식품위생관계 미생물에 대한 가열처리와 감마선조사의 병용효과)

  • 권오진;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.25 no.5
    • /
    • pp.804-809
    • /
    • 1996
  • The bactericidal effectiveness of radiation alone or in combination with heat against 8 strains associated with food hygiene were evaluated. In the case of radiation alone, D$_{10}$ values of micro-organisms were 0.14~0.48 kGy, and inactivation factors were 4.54~21.43 at the doses of 2~3 kGy. Escherichia coli was the most sensitive among the tested strains, resulting in a D$_{10}$ value of 0.14 kGy. D$_{min}$ values of tile strains were 10~40 minutes at $50\pm1^{\circ}C,$ and 5~10 minutes at $60\pm1^{\circ}C.$ Combination with heat and radiation showed D$_{10}$ values of 0.04~0.31. Inactivation factors were 6.45~75 at the doses of 2 to 3 kGy. Therefore, heat treatment prior to irradiation significantly increased mactivation rate by increasing radiation sensitivity of microorganisms.ganisms.

  • PDF

Difference in Radiation Absorbed Dose According to the Panoramic Radiographic Machines (파노라마방사선촬영기종에 따른 흡수선량 차이)

  • Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.30 no.1
    • /
    • pp.11-15
    • /
    • 2000
  • Purpose: The primary objective of this study was to estimate the radiation absorbed doses in certain critical organs in the head and neck region with an Orthopos plus, a Panelipse, and a Panex-E machines. The second objective was to compare the absorbed doses between 5 inch by 12 inch and 6 inch by 12 inch image field for the Orthopos plus. Materials and Methods: Rando phantom and LiF TLD chips were used for dosimetry. The absorbed doses were measured at the thyroid gland, the submandibular gland, the parotid gland, the mouth floor, the maxillary sinus, the brain, the mandibular body, the mandibular ramus, the 2nd cervical spine and the skin over TMJ area. Results: The highest absorbed dose value was recorded at the mandibular ramus for the Orthopos plus with narrow image field. Higher absorbed dose values were recorded at the parotid gland, the mouth floor, the submandibular gland, and the 2nd cervical spine. The doses in the parotid gland were 597 μGy and 529 μGy with Orthopos plus, 638 μGy with Panelipse, and 1094μGy with Panex-E. Corresponding figures for the mandibular ramus were 2363 Gy and 1220 μGy, 248 μGy, and 118 μGy. The absorbed doses to the thyroid gland, the maxillary sinus, the brain, and the skin over TMJ were very low. Conclusion: Higher exposure values were recorded for the Orthopos plus than Panelipse and Panex-E. There was no significant differences of the absorbed doses according to the image field size.

  • PDF

Measurement and Analysis of Pediatric Patient Exposure Dose Using Glass dosimeter and a PC-Based Monte Carlo Program (Glass dosimeter와 PCXMC Program을 이용한 소아피폭선량 측정 및 분석)

  • Kim, Young-Eun;Lee, Jeong-Hwa;Hong, Sun-Suk;Lee, Kwan-Seob
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.9-14
    • /
    • 2012
  • Exposed dose of young child should be managed necessarily. Young child is more sensitive than adult of a Radioactivity, especially, and lives longer than adult. Must reduce exposed dose which follows The ALARA(As Low As Reasonably Achievable)rule is recommended by ICRP(International Commission on Radiological Protection)within diagnostic useful range. Therefore, We have to prepare Pediatric DRL(Diagnostic Reference Level) in Korea as soon as possible. Consequently, in this study, wish to estimate organ dose and effective dose using PCXMC Program(a PC-Based Monte Carlo Program), and measure ESD(Entrance surface dose)and organ dose using Glass dosimeter, and then compare with DRL which follows EC(European Commission)and NRPB(National Radiological Protection Board). Using glass dosimeter and PCXMC programs conforming to the International Committee for Radioactivity Prevention(ICRP)-103 tissue weighting factor based on the item before the organs contained in the Chest, Skull, Pelvis, Abdomen in the organ doses and effective dose and dose measurements were evaluated convenience. In a straightforward way to RANDO phantom inserted glass dosimeter(GD352M)by using the hospital pediatric protocol, and in a indirect way was PCXMC the program through a virtual simulation of organ doses and effective dose were calculated. The ESD in Chest PA is 0.076mGy which is slightly higher than the DRL of NRPB(UK) is 0.07mGy, and is lower than the DRL of EC(Europe) which is 0.1mGy. The ESD in Chest Lateral is 0.130mGy which is lower than the DRL of EC(Europe) is 0.2mGy. The ESD in Skull PA is 0.423mGy which is 40 percent lower than the DRL of NRPB(UK) is 1.1mGy and is 28 percent lower than the DRL of EC(Europe) is 1.5mGy. The ESD in Skull Lateral is 0.478mGy which is half than the DRL of NRPB(UK) is 0.8mGy, is 40 percent lower than the DRL of EC(Europe) is 1mGy. The ESD in Pelvis AP is 0.293mGy which is half than the DRL of NRPB(UK) is 0.60mGy, is 30 percent lower than the DRL of EC(Europe)is 0.9mGy. Finally, the ESD in Abdomen AP is 0.223mGy which is half than the DRL of NRPB(UK) is 0.5mGy, and is 20 percent lower than the DRL of EC is 1.0mGy. The six kind of diagnostic radiological examination is generally lower than the DRL of NRPB(UK)and EC(Europe) except for Chest PA. Shouldn't overlook the age, body, other factors. Radiological technician must realize organ dose, effective dose, ESD when examining young child in hospital. That's why young child is more sensitive than adult of a Radioactivity.

  • PDF

Reducing of Craniofacial Radiation Dose Using Automatic Exposure Control Technique in the 64 Multi-Detector Computed Tomography (64 다중 검출기 전산화단층촬영에서 관전류 자동노출조절 기법을 이용한 두개부 방사선량 감소 정도 평가)

  • Seoung, Youl-Hun;Kim, Yong-Ok;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • The purpose of this study was to evaluate the usefulness of reducing of craniofacial radiation dose using automatic exposure control (AEC) technique in the 64 multi-detector computed tomography (MDCT). We used SOMATOM Definition 64 multi-detector CT, and head of whole body phantom (KUPBU-50, Kyoto Kagaku CO. Ltd). The protocol were helical scan method with 120 kVp, 1 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of FOV, $512{\times}512$ of matrix size, $64{\times}0.625\;mm$ of collimation, and 1 of pitch. The evaluation of dose reducing effect was compared the fixed tube current of 350 with AEC technique. The image quality was measured the noise using standard deviation of CT number. The range of craniofacial bone was to mentum end from calvaria apex, which devided three regions: calvaria~superciliary ridge (1 segment), superciliary ridge~acanthion (2 segment), and acanthion~mentum (3 segment). In the fixed tube current technique, CTDIvol was 57.7 mGy, DLP was $640.2\;mGy{\cdot}cm$ in the all regions. The AEC technique was showed that 1 segment were 30.7 mGy of CTDIvol, 340.7 $mGy{\cdot}cm$ of DLP, 2 segment were 46.5 mGy of CTDIvol, $515.0\;mGy{\cdot}cm$ of DLP, and 3 segment were 30.3 mGy of CTDIvol, $337.0\;mGy{\cdot}cm$ of DLP. The standard deviation of CT number was 2.622 with the fixed tube current technique and 3.023 with the AEC technique in the 1 segment, was 3.118 with the fixed tube current technique and 3.379 with the AEC technique in the 2 segment, was 2.670 with the fixed tube current technique and 3.186 with the AEC technique in the 3 segment. The craniofacial radiation dose using AEC Technique in the 64 MDCT was evaluated the usefulness of reducing for the eye, the parotid and thyroid with high radiation sensitivity particularly.