• 제목/요약/키워드: Gutta-percha cone

검색결과 55건 처리시간 0.022초

Successful nonsurgical treatment of type II dens invaginatus with 5 root canals using a self-adjusting file: a case report

  • George Taccio de Miranda Candeiro;Antonio Sergio Teixeira de Menezes;Ana Carolina Saldanha de Oliveira;Flavio Rodrigues Ferreira Alves
    • Restorative Dentistry and Endodontics
    • /
    • 제48권2호
    • /
    • pp.17.1-17.8
    • /
    • 2023
  • The present report describes the endodontic treatment of an Oehlers type II dens invaginatus in a maxillary lateral incisor with 5 root canals, an extremely rare condition. Apical periodontitis and related symptoms were noted. Cone-beam computed tomography was used to aid the diagnosis, reveal tooth morphology, and assist in canal location. The pulp chamber was carefully accessed, and the root canals were explored under magnification. All root canals were prepared with an R25 Reciproc Blue system and sodium hypochlorite (NaOCl) irrigation. After initial preparation, a self-adjusting file (SAF) with NaOCl and ethylenediaminetetraacetic acid was used to complement the disinfection. Additionally, calcium hydroxide medication was applied. Vertical compaction was used to fill the canals with a calcium silicate-based endodontic sealer and gutta-percha. After 12 months, the patient exhibited healing of the periapical region, absence of symptoms, and normal dental function. In conclusion, this nonsurgical treatment protocol was successful in promoting the cure of apical periodontitis. Both complementary disinfection with an SAF and use of calcium hydroxide medication should be considered when choosing the best treatment approach for dens invaginatus with very complex anatomy.

상아질 결합제로 처리된 수산화칼슘 plug의 근단부 폐쇄능에 관한 연구 (AN EXPERIMENTAL STUDY ON THE SEALING ABILITY OF A CALCIUM HYDROXIDE PLUG TREATED WITH DENTIN BONDING AGENT)

  • 김평식;황호길;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.187-201
    • /
    • 1996
  • The purpose of this study was to evaluate the sealing ability of a calcium hydroxide plug treated with a bonding agent. Ninety extracted human anterior teeth and premolars with single canal were used in this study. Crowns were removed. the canal's were instrumented. and the roots were randomly divided into three groups of 30 each. In control group. a single apical seat was prepared with #60 K file 1mm short of the apex and the root canal was obturated with Gutta-percha and Sealapex by the lateral condensation method. In experimental group 1 and group 2. to prepare an apical isthmus of 1mm in length. the first apical seat was prepared with a #45 K file 1mm short of the anatomical apex and with a #60 K file 2mm short for the second apical seat. Dry calcium hydroxide powders were packed in the apical isthmus with a hand plugger and #60 K file and then. the root canal was obturated with Gutta-percha and Seal apex by the lateral condensation method. In experimental group 2. following an application of the bonding agent to the plug. the root canal was obturated in the same way. The teeth of each group were immersed in a 2% methylene blue dye solution. for 1, 2, and 4 weeks. The distance from the tip of the cone to the deepest penetration was measured using the Tool maker's microscope. The results were as follows : 1. The teeth having the calcium hydroxide plug treated with the dentin bonding agent (experimental group 2) showed the lowest leakage with 1.4705mm and the control group without apical plug(no apical isthmus) showed the highest leakage with 3.1735mm. 2. The control group without apical plug showed higher leakage than experimental group 1 having the calcium hydroxide plug treated without the dentin bonding agent(p>0.05). 3. The control group without apical plug and experimental group 1, having the calcium hydroxide plug treated without the dentin bonding agent. showed higher leakage than experimental group 2. having the calcium hydroxide plug treated with the dentin bonding agent(p<0.001). 4. The immersion time had no significant effect on the degree of leakage. In conclusion, the results showed that the calcium hydroxide plug treated with the dentin bonding agent could decrease the microleakage from the root apex effectively.

  • PDF

GT rotary file을 이용한 근관성형법과 충전방법의 비교 (COMPARISON OF CANAL SHAPING METHODS WITH GTTM ROTARY FILE AND CONDENSATION METHODS)

  • 강유미;진정희;유미경;이세준;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제27권5호
    • /
    • pp.521-529
    • /
    • 2002
  • The purpose of this study was to compare the shaping time of two shaping methods and the leakage of three different obturation techniques. Ninty three canaled human molar teeth were used, which were randomly divided into two groups of forty teeth each and ten control teeth. After working length determination, the one group was prepared crown-down technique using rotary root canal instruments of GT rotary files .12/20, .10/20, .08/20 and .06/20 taper(Maillefer Instrument SA. Switzerland). The other group was instrumented with Gates Glidden burs(#1, #2, and #3) to coronal preparation and GT rotary files .08/20 and .06/30 taper to apical preparation. Shaping time was measured. After root canals were instrumented, they were divided to three subgroups and obturated as follows : Subgroup 1, obturated with single cone method Subgroup 2, obturated with lateral condensation : Subgroup 3, obturated with continuous wave technique. Three subgroups were obturated using non-standardized gutta-percha cone(Diadent, Korea, .06 or .08 taper) and AH-26(Dentsply DeTrey, Germany) as a root canal cement. Ten unobturated teeth served as positive and negative controls. After immersion in 2% methylene blue solution for 1 month, the teeth were washed during 24h. The teeth were demineralized in 10% nitric acid and dehydrated by immersion in 80, 90 and 100% ethyl alcohol. The teeth were finally cleared and stored in 100% methylsalicylate, and apical dye penetration was evaluated under stereomicroscope(Leica M420, LC, U.S.A)at $\times$8.75 magnification. Liner measurement of dye penetration was assessed with the use of digitalized image analysing system (analySIS, GmbH, Germany) The data were analysed statistically using independent T-test and Two-way ANOVA and Tukey test. The result were as follows 1. In canal prepared with GT$^{TM}$ rotary file, shaphing time taked more than the group of using Gates Glidden drill to coronal preparation without statistical significance (p>0.05) 2. The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files showed significantly more apical leakage than those of lateral condensation and continuous wave technique regardless of shaping method (p<0.05). 3 The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files and Gates Glidden drill showed significantly more apical leakage than those of continuous wave technique regardless of shaping method (p<0.05). 4. Regardless of shaping method, The group of continuous wave obturation showed less apical leakage than those of lateral condensation without statistical significance (p>0.05). 5. The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files and Gates Glidden drill showed more apical leakage than the group of lateral condensation using same shaping method with-out statistical significance (p>0.05).

칼슘실리케이트 계열 실러로 충전한 근관에서 재치료용 NiTi 파일의 효율성 (Efficacy of retreatment NiTi files for root canals filled with calcium silicate-based sealer)

  • 현재윤;조경모;박세희;이윤;이윤주;김진우
    • 구강회복응용과학지
    • /
    • 제38권4호
    • /
    • pp.213-221
    • /
    • 2022
  • 목적: 근관 치료에 사용된 실러의 양과, 재치료용 NiTi 파일이 근관충전재의 제거 효율에 미치는 영향을 알아보고자 하였다. 연구 재료 및 방법: 발거된 소구치 중 단일 근관을 가지는 치아를 대상으로 하였다. #40/.06까지 근관 형성을 한 후, 무작위로 4 그룹으로 분류하였다. 근관충전재 중 실러가 차지하는 양을 다르게 하기 위해 그룹 별로 .06 taper 또는 .04 taper 거타퍼차를 칼슘실리케이트 실러인 Ceraseal과 함께 사용하여 single-cone 충전법으로 충전하였다. 그룹 별로 재치료용 NiTi 파일로는 ProTaper Universal Retreatment system (PTUR) 또는 Hyflex Remover (HR)를 사용하였다. 충전재 제거에 걸린 시간, 치근단 방출 잔사량, 근관 내의 충전재 잔존량을 측정하고 비교하였다. 결과: 근관치료에 사용된 실러의 양은 충전재 제거 효율에 영향을 미치지 않았다. HR 그룹은 PTUR 그룹보다 빠르게 충전재를 제거하였다. 치근단 방출 잔사량과 근관충전재 잔존량은 재치료용 NiTi 파일의 종류에 따라 유의한 차이를 보이지 않았다. 결론: 근관치료에 사용된 실러의 양은 제거 효율에 유의한 영향을 미치지 않았다. HR는 기존의 PTUR보다 빠르게 충전재를 제거했으며, 다른 제거 효율은 차이가 없었다.

치아들을 탈회동결건조처리하여 제작한 치근천공부 충전재 개발 I: 예비실험연구 (Development of Root Perforation Filling Material using Demineralized Dentin Paste)

  • 최용훈;배지현;박지훈;김영균;윤필영;황지연;엄인웅;이종헌
    • 대한치과의사협회지
    • /
    • 제50권9호
    • /
    • pp.574-585
    • /
    • 2012
  • Purpose : This study was performed to evaluate the healing response around the root perforation restorative material. Materials and Methods : Four beagle dogs were used for experimental study. Endodontic treatment was performed at four maxillary premolars and artificial perforation was formed at furcation area of pulp chamber. Canal was filled with gutta percha cone and the perforation was sealed with MTA at group 1. At group 2, canal was filled and the perforation was sealed with dentin paste. Tooth paste was fabricated using extracted human teeth. Histologic examination of furcation area was performed 2, 4, 8 and 12 weeks after experiment. Results : New trabecular bone formation was observed around the MTA and tooth paste. Lamellar bone was observed as time is over. There were no inflammatory reaction in both groups. Conclusion : There is a possibility which endodontic filling material can be developed using extracted teeth.

Influence of size and insertion depth of irrigation needle on debris extrusion and sealer penetration

  • Uzunoglu-Ozyurek, Emel;Karaaslan, Hakan;Turker, Sevinc Aktemur;Ozcelik, Bahar
    • Restorative Dentistry and Endodontics
    • /
    • 제43권1호
    • /
    • pp.2.1-2.10
    • /
    • 2018
  • Objectives: To determine the effect of size and insertion depth of irrigation needle on the amount of apical extruded debris and the amount of penetration depth of sealer using a confocal laser scanning microscope (CLSM). Materials and Methods: Twenty maxillary premolars were assigned to 2 groups (n = 10), according to the size of needle tip, 28 G or 30 G. Buccal roots of samples were irrigated with respective needle type inserted 1 mm short of the working length (WL), while palatal roots were irrigated with respective needle type inserted 3 mm short of the WL. Prepared teeth were removed from the pre-weighed Eppendorf tubes. Canals were filled with F3 gutta-percha cone and rhodamine B dye-labeled AH 26 sealer. Teeth were transversally sectioned at 1 and 3 mm levels from the apex and observed under a CLSM. Eppendorf tubes were incubated to evaporate the irrigant and were weighed again. The difference between pre- and post-weights was calculated, and statistical evaluation was performed. Results: Inserting needles closer to the apex and using needles with wider diameters were associated with significantly more debris extrusion (p < 0.05). The position of needles and level of sections had statistically significant effects on sealer penetration depth (p < 0.05 for both). Conclusions: Following preparation, inserting narrower needles compatible with the final apical diameter of the prepared root canal at 3 mm short of WL during final irrigation might prevent debris extrusion and improve sealer penetration in the apical third.

치근단 손상부의 치유에 영향을 미치는 제재에 관한 병리조직학적 연구 (HISTOPATHOLOGIC STUDY ON THE HEALING PROCESS OF APICAL WOUND IN APPLYING SEVERAL MATERIALS)

  • 조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제14권2호
    • /
    • pp.49-64
    • /
    • 1989
  • The purpose of this study was to evaluate the effect of several materials on the healing process of apical wound. Sixteen mandibular premolars obtained from 4 healthy dogs were used for this study. Under general anesthesia, the pulpal chamber of each tooth was opened and the pulps were extirpated. The root canals were then instrumented with H-file and irrigated with physiologic saline solution ; the apices were purposely perforated and enlarged with the engine K-reamer. In the experimental groups, apical wounds were filled with one of calcium hydroxide, hydroxylapatite, and tricalcium phosphate materials, mixture of each materials and physiologic saline solution, with a lentulo spiral. In the control group, apical wounds were not filled with any material. All the root canals were filled by the lateral condensation technique with gutta-percha cone and ZOE sealer. The access opening of all the teeth were closed with amalgam. On the 10, 20, 40 and 60th day after experiment, experimental animals were sacrificed. Segments of jaws, each containing one tooth, were fixed in 10% formalin solution and decalcified in Plank-Rychlo solution. The specimens were embedded in paraffin and serially sectioned to an average thickness of $6{\mu}m$. The sections were stained by hematoxylin-eosin and Masson's trichrome stain method and examined under light microscope. The results were as follows : 1. In the experimental groups, the new bone formations were observed in apical wounds. 2. Fourty days later, apical wounds were healed by granulation tissue in the experimental groups, but were not healed by granulation tissue in the control group, and the healing process of experimental groups were more rapid than that of control group. 3. Sixty days later, chronic inflammation disappeared in the experimental groups, and the materials used showed biologic affinity to the periapical tissue. 4. In all the groups, the resorption of cementum appeared on the 10th and 20th day after experiment, and the deposition of cementum appeared on the 40th and 60th day after experiment, especially showing narrowness of apical foramen due to newly formed cementum in calcium hydroxide group. 5. Calcum hydroxide and tricalcium phosphate particles were gradually resolved, but hydroxylapatite particles were not resolved through the experimental period.

  • PDF

근관충전 시 수분오염이 치근단 폐쇄성에 미치는 영향에 관한 연구 (A STUDY ON THE EFFECT OF MOISTURE ON APICAL SEALING PROPERTY OF ROOT CANAL)

  • 임성삼;강명회
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.628-634
    • /
    • 1996
  • The purpose of this study was to investigate the effect of moisture on apical sealing properties of root canal. Fifty five single rooted human teeth were selected from maxillary and mandibular teeth. After removing crown portion at the cemento-enamel junction, all teeth were routinely prepared with step-back method. And then, the canals were dried with paper point and the teeth were randomly divided into 3 groups of 15 teeth each, and remaining 10 teeth were used as positive and negative control teeth : Group 1 were irrigated with 1ml of 95% alcohol and dried with air and paper point. Group 2 and 3 were intentionally contaminated with 0.05ml of 3.5% NaOCl or saliva, respectively. All the teeth were obturated with sealapex and gutta percha cone by lateral condensation technique, and covered with two coat of nail varnish after 48 hours of obturation. The teeth were immersed in india ink for 1 week and cleaned with methyl salicylate and then the degree of dye penetration were measured with stereomicroscope. The data were analyzed statistically by one-way ANOVA. The results were as follows : 1. All experimental groups showed varying degrees of dye penetration, and the mean degree of dye penetration was 0.1mm to 0.7mm. 2. Saliva contamination group(group 3) showed the highest amount of dye penetration, followed by NaOCl contamination group, then alcohol dried group, but there was no significant difference among three experimental groups. * This results suggest that there was no significant differences of apical leakage after canal obturation between alcohol dried canal and moisture present canals and the use of alcohol instead of paper point is unnecessary to dry the canals prior to canal filling. But other factors such as bacterial contamination and sealer discoloration by moisture must be considered in application of this results to clinical practice.

  • PDF

Buckling resistance, torque, and force generation during retreatment with D-RaCe, HyFlex Remover, and Mtwo retreatment files

  • Yoojin Kim ;Seok Woo Chang;Soram Oh
    • Restorative Dentistry and Endodontics
    • /
    • 제48권1호
    • /
    • pp.10.1-10.9
    • /
    • 2023
  • Objectives: This study compared the buckling resistance of 3 nickel-titanium (NiTi) retreatment file systems and the torque/force generated during retreatment. Materials and Methods: The buckling resistance was compared among the D-RaCe (DR2), HyFlex Remover, and Mtwo R25/05 retreatment systems. J-shaped canals within resin blocks were prepared with ProTaper NEXT X3 and obturated by the single-cone technique with AH Plus. After 4 weeks, 4 mm of gutta-percha in the coronal aspect was removed with Gates-Glidden drills. Retreatment was then performed using DR1 (size 30, 10% taper) followed by DR2 (size 25, 4% taper), HyFlex Remover (size 30, 7% taper), or Mtrwo R25/05 (size 25, 5% taper) (15 specimens in each group). Further apical preparation was performed with WaveOne Gold Primary. The clockwise torque and upward force generated during retreatment were recorded. After retreatment, resin blocks were examined using stereomicroscopy, and the percentage of residual filling material in the canal area was calculated. Data were analyzed using 1-way analysis of variance with the Tukey test. Results: The HyFlex Remover files exhibited the greatest buckling resistance (p < 0.05), followed by the Mtwo R25/05. The HyFlex Remover and Mtwo R25/05 files generated the highest maximum clockwise torque and upward force, respectively (p < 0.05). The DR1 and DR2 files generated the least upward force and torque (p < 0.05). The percentage of residual filling material after retreatment was not significantly different between file systems (p > 0.05). Conclusions: NiTi retreatment instruments with higher buckling resistance generated greater clockwise torque and upward force.

Diagnostic accuracy of cone-beam computed tomography scans with high- and low-resolution modes for the detection of root perforations

  • Shokri, Abbas;Eskandarloo, Amir;Norouzi, Marouf;Poorolajal, Jalal;Majidi, Gelareh;Aliyaly, Alireza
    • Imaging Science in Dentistry
    • /
    • 제48권1호
    • /
    • pp.11-19
    • /
    • 2018
  • Purpose: This study compared the diagnostic accuracy of cone-beam computed tomography (CBCT) scans obtained with 2 CBCT systems with high- and low-resolution modes for the detection of root perforations in endodontically treated mandibular molars. Materials and Methods: The root canals of 72 mandibular molars were cleaned and shaped. Perforations measuring 0.2, 0.3, and 0.4 mm in diameter were created at the furcation area of 48 roots, simulating strip perforations, or on the external surfaces of 48 roots, simulating root perforations. Forty-eight roots remained intact(control group). The roots were filled using gutta-percha (Gapadent, Tianjin, China) and AH26 sealer (Dentsply Maillefer, Ballaigues, Switzerland). The CBCT scans were obtained using the NewTom 3G (QR srl, Verona, Italy) and Cranex 3D (Soredex, Helsinki, Finland) CBCT systems in high- and low-resolution modes, and were evaluated by 2 observers. The chi-square test was used to assess the nominal variables. Results: In strip perforations, the accuracies of low- and high-resolution modes were 75% and 83% for NewTom 3G and 67% and 69% for Cranex 3D. In root perforations, the accuracies of low- and high-resolution modes were 79% and 83% for NewTom 3G and was 56% and 73% for Cranex 3D. Conclusion: The accuracy of the 2 CBCT systems was different for the detection of strip and root perforations. The Cranex 3D had non-significantly higher accuracy than the NewTom 3G. In both scanners, the high-resolution mode yielded significantly higher accuracy than the low-resolution mode. The diagnostic accuracy of CBCT scans was not affected by the perforation diameter.