• 제목/요약/키워드: Gutta-percha

검색결과 181건 처리시간 0.035초

수종의 apical plug 재료의 근단 폐쇄성에 관한 실험적 연구 (EVALUATION OF APICAL PLUG MATERIALS USED FOR THE CONTROL OF EXTRUSION OF HIGH-TEMPERATURE THERMOPLASTICIZED GUTTA-PERCHA)

  • 허은정;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.205-216
    • /
    • 1994
  • The purpose of this study is to evaluate of apical plug materials for the contral of extrusion and sealing ability of high-temperature thermoplasticized gutta-percha in plastic root canal blocks. Seventy seven plastic blocks with canal preformed were instrumented with # 50K file 1 mm beyond apical foramen. Blocks were randomly divided into 5 groups of 15 blocks each. Group 1 was filled by high-temperature thermoplasticized gutta-percha only. The another 4 groups were placed with apical plug materials each other and then remaining space was back filled with high temperature thermoplasticized gutta-percha Apical plug materials were used as follows; Group 2: Thermoplasticized gutta-percha (Thermoplasticized gutta-percha group) Group 3 :. Calcium hydroxide powder (Calcium hydroxide group) Group 4 : Silver point (Silver point group) Group 5 : Gutta-percha cone softened by chloroform (Gutta-percha cone group) All the blocks were stored in 100 % relative humidor at room temperature for 14 days. Filling material extruded was removed carefully and then weighed in analytic balance. Each block was placed in centrifuge tube filled with India ink, and then centrifuged for 20 minutes at 3,000 rpm. Apical leakage was measured from the apical foramen to the most coronal level of dye leakage in millimeter by two examiners under a stereoscope. The data were analysed statistically by Student's t-test The obtained results were as follows; 1. The amounts of material extruded through the foramen decreased in all of groups used apical plug materials (P<0.01). 2. Silver point group and gutta-percha cone group were similar linear leakage to high-temperature thermoplasticised gutta-percha technique only (P>0..5). 3. Calcium hydroxide group and thermoplasticized gutta-percha group showed more liner leakage than high-temperature thermoplasticized gutta-percha only (P<0.01, P<0.05). 4. High-temperature thermoplasticized gutta-percha technique with silver point and gutta-percha cone as apical plugs showed less linear leakage and less extrusion of filling material.

  • PDF

수종 소독제가 Gutta-percha cone의 물리적 성질에 미치는 영향에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF THE EFFECT OF THE VARIOUS ANTISEPTIC STRORAGE SOLUTIONS ON PHYSICAL PROPERTIES OF GUTTA-PERCHA CONE)

  • 이미영;박동수
    • Restorative Dentistry and Endodontics
    • /
    • 제16권1호
    • /
    • pp.209-215
    • /
    • 1991
  • The propose of this study was to evaluate the effect of the variuos antiseptic solutions and distilled water on physical properties of endodontic gutta-percha cone. The antiseptic solutions were 70% isoprophyl alcohol, 5% NaOCl and 2.5% NaOCl, as control gutta-percha cones, did not stored antiseptic solution was used. Observation periods were 1, 5, 10, 20, and 30 days. In each group,. the 15 gutta-percha cones used. A tensile strength and elongation rate measurements were performed with Instron (Instron 4501), cross - head speed was set 10 inch / min. The data were statistically analyzed and the results were as followed. 1. The tensile strength of the gutta-percha cones, stored in distilled water, were slightly decreased (p<0.05). Elongation rate was not significantly different 2. The tensile strength of the gutta-percha cones, stored in 70% isopropyl alcohol, were increased (p<0.01) except 1 day group. 3. The tensile strength of the gutta-percha cone, stored in 2.5% NaOCl, were decreased (p<.0.05). Elongation rate significantly decreased (p<0.01). 4. The tensile strength of the gutta-percha cone, stored in 5% NaOCl, were decreased (p<0.05). Elongation rate significantly decreased (p<0.01). These results showed that the changes of physical properties (tensile strength and elongation rate) in gutta-percha cone were developed after a day' when gutta-percha cone were stored at 70% isopropyl alcohol, 2.5% or 5% NaOCl. So, It was concluded that gutta-percha cone must have been used at least within one day, when they were stored at the above antiseptics. I thought that the study of substantial effects on endodontic treatment due to changes of physical properties in gutta-percha cone will be needed.

  • PDF

Gutta-percha를 이용(利用)한 세가지 근관충전법(根管充塡法)의 부근관충전(副根管充塡) 효과비교(效果比較) (A COMPARISON OF THE ACCESSORY CANAL FILLING EFFECTS OF THE THREE ROOT CANAL FILLING METHODS WITH GUTTA-PERCHA)

  • 안성호;조규징
    • Restorative Dentistry and Endodontics
    • /
    • 제14권1호
    • /
    • pp.121-133
    • /
    • 1989
  • In order to compare the accessory canal filling effects of the three root canal filling methods with gutta-percha, the author fabricated artificial root canal mold with the first and second accessory canals of chrome-cobalt alloy. After the artificial root canal was filled with gutta-percha by lateral condensation, vertical condensation and low-temperature thermoplasticized gutta-percha injection-molded method, twenty five times respectively, the gutta-percha forced into the first and second accessory canals were measured with caliper for length. The results were as follows: 1. The filling in both accessory canals was most effective in low-temperature thermoplasticized gutta-percha injection-melded method followed in such order as: vertical condensation method and lateral condensation method (p < 0.01). 2. The filling effect of the second accessory canal was more or less higher than that of the first one (p < 0.05). 3. Low-temperature thermoplasticized gutta-percha injection-molded method was fastest in time needed for root canal filling followed by lateral condensation method and vertical condensation method.

  • PDF

리본 형태의 근관에서 열연화주입법의 근관벽에 대한 적합도에 관한 연구 (A COMPARISON OF THERMOPLASTICIZED INJECIABLE GUTTA-PERCHA TECHNIQUES IN RIBBON-SHAPED CANALS : ADAPTATION TO CANAL WALLS)

  • 황현숙;조경모;김진우
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.411-420
    • /
    • 2002
  • The aim of this study is to compare the adaptability of thermoplasticized injectable gutta-percha technique to the canal walls in ribbon-shaped canals. Thirty resin models simulated ribbon-shape canals were instrumented to #40 using .06 taper Profile systems. Three groups of each 10 resin models were obturated by the lateral condensation technique(LC) and the two thermoplasticized injectable gutta-percha technique; Ultrafil Endoset+Obtura II(EO) and Ultrafil Firmset(UF), respectively. After resin model were kept at room temperature for 4 days, they were resected horizontally with micro-tome at 1, 2, 3, 4 and 5mm levels from apex. At each levels. image of resected surface were taken using CCD camera under a stereomicroscope at $\times$40 magnification and stored. Ratio of the area of gutta-percha was obtained by calculating area of gutta-percha cone to the total area of canal using digitized image-ana-Iyzing program. The data were collected then analyzed statistically using One-way ANOVA. The results were as follows. 1 At 1mm levels, there was no statistically significant difference in the mean ratio of gutta-percha among the groups. 2. At 2mm level, EO showed the highest mean ratio of gutta-percha (p<0.05) and there was no significant difference between LC and UF. 3. At 3, 4, 5mm levels, EO and UF had significantly greater mean ratio of gutta-percha than LC(p<0.05) and there was no significant difference between EO and UF. In conclusion, the thermoplasticized injectable gutta-percha techniques demonstrated relatively favorable adaptability to canal walls than lateral condensation technique in ribbon-shaped canals except for 1mm level.

Microseal 열연화 근관충전법의 치근단 밀폐효과에 관한 연구 (THE EFFECT OF MICROSEAL OBTURATION TECHNIQUE ON THE APICAL SEAL OF ROOT CANALS)

  • 최중조;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.356-363
    • /
    • 1999
  • The purpose of this study was to compare the apical sealing effect of Microseal obturation technique with lateral condensation technique in 26 recently extracted single rooted teeth. The root canals were instrumented using step-back technique and obturated with laterally condensed gutta-percha or Microseal. Teeth were suspended in methylene blue dye for 2 days and then longitudinary splited. The apical microleakage and the adaptability of gutta-percha to the root canal wall were examined under a stereomicroscope at ${\times}20$ magnification. The results were as follows: 1. The mean leakage was 1.38${\pm}$1.18 mm for laterally condensed gutta-percha group, and 0.71${\pm}$0.57 mm for Microseal gutta-percha group. But there was no statistical difference between two groups. 2. In Microseal gutta-percha group, they showed no gap between the master cone and Microseal gutta-percha, and showed homogeneous mass. 3. In contrast, laterally condensed gutta-percha group showed some gaps not only between gutta-percha cones, but also between gutta-percha cones and the canal walls, and the gaps were filled with some sealer. And also this group showed some amout of sealer on the root canal walls, Within the limits of the results of this experiment, Microseal gutta-percha obturation technique demonstrated relatively favorable apical sealing effect and shorter obturation time. Thus, it is thought that this obturation technique is a acceptable method for clinical use but further studies on this matter should be conducted.

  • PDF

리본형태의 근관에서의 열연화 근관 충전법의 비교 : 근관 충전된 gutta-percha의 무게 (COMPARISON OF WARM GUTTA-PERCHA CONDENSATION TECHNIQUES IN RIBBON SHAPED CANAL : WEIGHT OF FILLED GUTTA-PERCHA)

  • 김현희;조경모;김진우
    • Restorative Dentistry and Endodontics
    • /
    • 제27권3호
    • /
    • pp.277-283
    • /
    • 2002
  • The purpose of this study is to evaluate the two warm gutta-percha filling techniques by measuring the weight changes of resin blocks before and after canal filling in ribbon shaped canal. Simulated ribbon shaped root canals in 30 transparent resin blocks were instrumented to #40 using .06 taper Profile. 15 resin blocks were obturated with gutta-percha using cold lateral condensation. Warm lateral condensation using the Endotec II was then accomplished on the same 15 blocks. Another 15 resin blocks were obturated using the System B. All canals were obturated without sealer. The resin blocks were weighed after canal preparation and after each subsequent obturation, and then weight changes of the resin blocks were calculated The results were as follows. 1. Warm lateral condensation using Endotec II and continuous wave of condensation using System B produced a denser obturation of gutta-percha compared with conventional cold lateral condensation (p<0.01). 2. There was no significant difference between warm lateral condensation and continuous wave condensation. In conclusion, the warm gutta-percha condensation techniques like warm lateral condensation and continuous wave condensation can be expected to bring favorable canal obturation results in ribbon shaped canals.

엔진 구동형 니켈 티타늄 파일을 이용한 거터퍼쳐의 제거 효과 (THE EFFECT OF GUTTA-PERCHA REMOVAL USING NICKEL-TITANIUM ROTARY INSTRUMENTS)

  • 전정훈;민정범;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제29권3호
    • /
    • pp.212-218
    • /
    • 2004
  • The purpose of this study was to quantify the amount of remaining gutta-percha/sealer on the walls of root canals when three types of nickel-titanium rotary instruments (Profile. ProTaper and $K^3$) and a hand instrument(Hedstrom file) used to remove these materials. The results of this study were as follows: 1. In the total time for gutta-percha removal. Profile group was the fastest and followed by $K^3$, Protaper, Hedstrom file group. 2. In case of the evaluation of the volume of remained gutta-percha from radiograph. $K^3$ group got the highest score and followed by Protaper. Hedstrom file. Profile group in the apical 1/3. 3. In case of the evaluation of the volume of gutta-percha remained from stereomicroscope, $K^3$ group got the highest score and followed by Protaper. Hedstrom file. Profile group in the apical 1/3. These results showed that instrumentation using nickel-titanium rotary instrument groups was faster than that using hand instrument group. The effect of gutta-percha removal using Profile group was better than that using Protaper and $K^3$ group in the nickel-titanium rotary instrument groups.

0.06-경사도의 니켈-티타늄 기구로 형성된 레진 만곡근관에서 비표준화 GUTTA-PERCHA CONE의 근관충전 효율 (Obturation efficiency of non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments)

  • 이은아;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제30권2호
    • /
    • pp.79-85
    • /
    • 2005
  • 최근, 다양한 경사도의 니켈-티타늄 근관기구와 더불어 다양한 경사도의 gutta-percha cone이 소개되었다. 효율적인 근관 충전을 위해서는 짧은 시간에 적은 수의 기구 및 재료를 사용하여 균일한 gutta-percha로 근관을 충전할 필요가 있다. 본 연구에서는 0.06 경사도의 니켈-티타늄 전동화일로 형성된 만곡 근관에서 측방 가압법으로 근관충전시 비표준화 medium 크기 master gutta-percha cone의 충전효율을 ISO 표준화 규격의 master cone과 비교하여 평가하고자 하였다. 60개의 모형레진 만곡근관에서 0.06 경사도의 니켈-티타늄 전동화일 ($ProTaper^{TM},\;ProFile^{(R)}$, Dentsply-Maillefer, Ballaigues, Switzerland)을 사용하여 근단부 근관이 30번 크기가 되게 crown-down법으로 근관을 형성하였다. 근관은 master gutta-percha cone, AH 26 실러 (Dentsply-DeTrey, Konstanz, Germany), 그리고 type A accessory cone (Dentsply-Maillefer, Ballaigues, Switzerland)을 사용하여 측방가압법으로 충전하였으며, 이 때 사용된 master gutta-percha cone(Diadent, Chongju, Korea)과 Finger spreader(B type, Dentsply-Maillefer, Ballaigues, Switzerland)에 따라 임의로 15개씩 4개의 군으로 나누어 실험하였는데, St/SS 군에서는 ISO 표준화 규격의 30번 master cone과 스테인레스 스틸 finger spreader를, St/NT 군에서는 ISO 표준화 규격의 30번 master cone과 니켈-티타늄 finger spreader를, Non-St/SS 군에서는 비표준화 medium 규격 master cone과 스테인레스 스틸 spreader를, 그리고 Non-St/NT 군에서는 비표준화 medium 크기 master cone과 니켈-티타늄 finger spreader를 각각 사용하였다. 충전된 근관은 $37^{\circ}C$, 상대습도 $100\%$하에서 24시간 보관한 후, 치근단 1, 3및 5 mm수준에서 횡절단하여 입체현미경 하에서 관찰하고 컴퓨터에 저장한 다음, $Auto^{(R)}$CAD 2000 프로그램을 이용하여, 형성된 근관 및 gutta-percha 충전물의 외형을 추적하여 근관내 gutta-percha 면적비를 계산하였다. Gutta-percha 면적비의 결과치는 two-way ANOVA를, 그리고 accessory cone 수는 one-way ANOVA 및 Duncan's multiple range test를 이용하여 통계 분석하여 다음과 같은 결과를 얻었다. 스테인레스 스틸 finger spreader를 사용한 경우 및 니켈-티타늄 finger spreader를 사용한 경우 공히, 모든 치근단 수준에서 비표준화 medium 크기 master cone 사용군이 ISO 표준화 규격의 master cone 사용군에 비해 유의하게 높은 gutta-percha 면적비를 나타내었다 (p < 0.01). 비표준화 medium크기 master cone 사용군에서는 표준화 규격의 master cone 사용군에 비해 유의하게 적은 수의 accessory cone이 사용되었다 (p < 0.01).

호제근충재(糊劑根充材) Vitapex의 근관폐쇄성(根管閉鎖性)에 관(關)한 연구(硏究) (A STUDY ON THE USE OF VITAPEX WITH GUTTA-PERCHA CONES AS A ROOT CANAL FILLER)

  • 임성삼
    • Restorative Dentistry and Endodontics
    • /
    • 제9권1호
    • /
    • pp.127-132
    • /
    • 1983
  • The purpose of this study was to examine the sealing ability of the vitapex, when used with gutta-percha cone, as a root canal filling material. Fourty five canals from extracted human maxillary and mandibular teeth were randomly selected and instrumented in a conventional method with k-file. After instrumentation and dry the canal with paper points, the canals were divided into three groups and fifteen canals in each group were filled with the following materials; Vitapex, Vitapex in combination with gutta-percha cone, and Gutta-percha cone and Zinc-oxide Eugenol Cement. All the specimens were immersed in 2% methylenblue dye solution and the depth of dye penetration into the canals were evaluated by macroscope at the intervals of 1 day, 2days and 7days. The following results were obtained; 1. All the materials experimented showed varying degrees of dye penetration. 2. The canals filled with Vitapex and Vitapex in combination with gutta perch a cone revealed sudden increase of dye penetration with time passage compared to the canals obturated with Gutta-percha cone and Zinc-oxide eugenol cement. 3. In the canals filled with Vitapex, the mean dye penetration was 1.6mm at 1day, but the specimen exposed to the dye for 7days showed mean dye penetration of 9.2mm. 4. In the canals obturated with Vitapex and gutta-percha cone, the mean dye penetration was 2mm at 1day, 2.2mm at 2days, and 8mm at 7days.

  • PDF

수 종의 근관충전재의 열팽창 특성 측정 : Gutta-percha와 Resilon (Measurement of thermal expansion characteristic of root canal filling materials : Gutta-percha and Resilon)

  • 전경아;이인복;배광식;이우철;백승호
    • Restorative Dentistry and Endodontics
    • /
    • 제31권5호
    • /
    • pp.344-351
    • /
    • 2006
  • 근관충전재로 사용되는 gutta-percha의 대체재로서 Resilon이라는 bioactive glass와 약간의 방사선 불투과성 성분을 포함하는 열가소성 고분자가 최근 소개되었다. 본 연구에서는 열연화 주입식 gutta-percha와 Resilon의 열팽창 특성을 측정하고 상호 비교하였다. 실험재료 중 gutta-percha 군으로는 Obtura, Diadent 그리고 Metadent사의 gutta-percha를, Resilon으로 Pentron사의 Epiphany를 사용하였다. 열가압주입기인 Obtura II에 4가지 재료를 넣고 설정온도를 $100^{\circ}C$, $150^{\circ}C$, $180^{\circ}C$ 그리고 $200^{\circ}C$로 바꾸어 가며 각 온도에 대해서, heat-ing chamber 입구에서의 온도와 23 게이지와 20 게이지의 needle에서 사출되는 재료의 온도를 디지털 thermometer를 이용하여 측정하였다. 열팽창을 측정하기 위해 세라믹으로 내경 3 mm, 외경 10 mm. 길이 27 mm의 원통형 주형을 제작하였고, 주형 안에 각 재료를 채워 넣은 후 양끝을 세라믹 공이 (plunger)로 막았다. 이 시편을 dilatometer에 넣고 가열하여 $25^{\circ}C$에서 $75^{\circ}C$까지의 범위에서 열팽창 곡선을 얻었다. 온도에 따른 시편의 길이 변화로부터 각 재료의 열팽창 계수와 전체부피에 대한 팽창량을 계산하였다. 모든 재료에서 온도가 증가함에 따라 $45^{\circ}C$ 이하에서는 재료의 부피변화가 거의 없었고, $45^{\circ}C$에서 $55^{\circ}C$ 구간에서 급격히 팽창하였으며 그 이상의 온도에서는 완만한 부피의 증가를 보였다. $35^{\circ}C$에서 $55^{\circ}C$ 사이에서의 부피의 변화는 재료들 사이에 통계적으로 유의한 차이가 없었으며 (p > 0.05). $35^{\circ}C$에서 $75^{\circ}C$사이의 부피의 변화는 Obtura 사 gutta-percha가 Metadent사와 Diadent사의 gutta-percha에 비해 유의하게 작은 것으로 나타났다 (p <0.05). Epiphany는 gutta-percha 군들과 비슷한 열팽창을 보였다 (p > 0.05).