• 제목/요약/키워드: Gun Gas

Search Result 452, Processing Time 0.028 seconds

Design Improvement of Vent System for Korean Utility Helicopter's Anti-Explosion Fuel Tank (한국형 기동헬기 내폭발성 만족을 위한 연료 벤트 시스템 설계개선)

  • Kim, Joung-Hun;Kim, Chang-Young;Chang, Joong-Jin;Lee, Mal-Young;Shim, Dai-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.1
    • /
    • pp.76-81
    • /
    • 2014
  • Military helicopter is exposed to the enemy gun firing due to the low altitude flight of contour flight, hovering & nap of the Earth flight, therefore it has the high possibility to be exploded by the gun firing. Recently the Anti-ballistic requirement is required to get the high level of safety from gun firing in required operational capability. The first military utility helicopter of SURION has the Anti-ballistic requirement and explosion proof. In order to meet the requirement, OBIGGS is adopted for the first time in KUH. It is proven that Anti-Explosion capability is satisfied to requirement for improving vent system which was insufficiently designed in development period and related to Anti-explosion.

Optimal Condition of Hydroxyapatite Powder Plasma Spray on Ti6Al4V Alloy for Implant Applications

  • Ahn, Hyo-Sok;Lee, Yong-Keun
    • Korean Journal of Materials Research
    • /
    • v.22 no.4
    • /
    • pp.211-214
    • /
    • 2012
  • Optimal conditions for HA plasma spray-coating on Ti6Al4V alloy were investigated in order to obtain enhanced bone-bonding ability with Ti6Al4V alloy. The properties of plasma spray coated film were analyzed by SEM, XRD, surface roughness measurement, and adhesion strength test because the film's transformed phase and crystallinity were known to be influential to bone-bonding ability withTi6Al4V alloy. The films were formed by a plasma spray coating technique with various combinations of plasma power, spray distance, and auxiliary He gas pressure. The film properties were analyzed in order to determine the optimal spray coating parameters with which we will able to achieve enhanced bone-bonding ability with Ti6Al4V alloy. The most influential coating parameter was found to be the plasma spray distance to the specimen from the spray gun nozzle. Additionally, it was observed that a relatively higher film crystallinity can be obtained with lower auxiliary gas pressure. Moderate adhesion strength can be achievable at minimal plasma power. That is, adhesion strength is minimally dependent on the plasma power. The combination of shorter spray distance, lower auxiliary gas pressure, and moderate spray power can be recommended as the optimal spray conditions. In this study, optimal plasma spray coated films were formed with spray distance of 70 mm, plasma current of 800 A, and auxiliary gas pressure of 60 psi.

Performance Analysis of GT/ST Hybrid System for Marine Power Applications(under Conditions of Air-Cooled Gas Turbine) (가스터빈의 냉각공기를 고려한 선박동력용 GT/ST 하이브리드시스템의 성능 평가)

  • Kim, Sun-Hee;Jung, Byung-Gun;Kim, Myoung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.586-594
    • /
    • 2012
  • A future type ship power system requires both economic and eco-friendliness. That is, this should be reduced the discharge quantity of air pollutants and green-house gases as well as have high energy efficiency. Recently, gas turbines have been realized a lot of technical development in terms of efficiency and safety, and are widening the example of their adoption to a GT/ST hybrid system in a power plant as well as an aviation use. This paper reviewed the performance characteristics of a GT/ST hybrid system of several ten MW class, not large capacity, with a simulation in order to evaluate the possibility of a GT/ST hybrid system for ships. The reviewed GT/ST hybrid system has maximum 49 % efficiency, has the highest efficiency point for TIT, and has a 70~75 % and 25~30 % load ratio for a gas turbine and a steam turbine respectively.

Catalystic effect of Sludge on $NO_x$ removal in Packed bed reactor (Packed bed형 반응기에서 $NO_x$ 제거에 미치는 슬러지의 촉매효과)

  • Park, Jae-Yoon;Lee, Dong-Hoon;Koh, Hee-Suk;Jung, Jang-Gun;Bae, Myung-Whan;Kim, Jong-Dal
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1780-1782
    • /
    • 2001
  • In this experiment, an attempt to use the sludge pellets as catalyst for NO removal from simulated gas is experimentally investigated by using $BaTiO_3$-sludge packed-bed reactor of plate-plate geometry. An experimental investigation has been conducted for NO concentration of 50[ppm] balanced with air, a gas flow rate of 5[1/min]. $BaTiO_3$ pellets are filled at upstream of reactor for corona discharge and sludge pellets are put at downstream of reactor for catalystic effect. The volume rate of sludge pellets to $BaTiO_3$ pellets is 50[%] and AC voltage to dischare the gases was supplied. In the result, when sludge pellets is seperated to $BaTiO_3$ by other reactor and AC voltage is supplied to $BaTiO_3$ and sludge pellets NO, $NO_2$ removal rate is higher. When gas temperature increase from room temperature to 100[$^{\circ}C$], NO removal is decreased while $NO_2$ concentration is independent on gas temperature. This result suggest that the removal mechanism of active oxyzen species and $NO_2$ in sludge is not absorption, but chemical reaction. Temperature of heating treatment is on sludge pellets increased, $NO_x$ removal rate is decrease. It is thought that organic compound is removed by heating treatment.

  • PDF

Phase-resolved CARS Temperature Measurements in a Lean Premixed Gas Turbine Combustor (2);Effect of equivalence ratio on phase-resolved gas temperature (CARS를 이용한 희박 예혼합 가스터빈 연소기내 온도 측정 (2);당량비가 위상별 온도에 미치는 영향)

  • Lee, Jong-Ho;Moon, Gun-Feel;Park, Chul-Woong;Hahn, Jae-Won;Jeon, Chung-Hwan;Chang, Young-June
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.103-108
    • /
    • 2003
  • The effect of equivalence ratio and fuel/air mixing quality on the phase-resolved gas temperatures at different phases of the oscillating pressure cycle was experimentally investigated. An atmospheric pressure, optically accessible and laboratory-scale dump combustor operating on methane with heat release rate of 1.59kW was used. Temperature measurements were made using coherent anti-Stokes Raman spectroscopy (CARS) at several spatial locations for typical unstable combustion conditions. Analysis was conducted using parameters such as phase-resolved averaged temperature, normalized standard deviation and temperature probability distribution functions (PDFs). Also the probability on the occurrence of high temperature (over 1900K) was investigated to get the information on the perturbation of equivalence ratio and NOx emission characteristics. It was shown that most of temperature histograms exhibit Gaussian profile which has short breadth of temperature fluctuation at equivalence ratio of 0.6, while beta profile was predominant for the cases of other equivalence ratios (${\Phi}$=0.55, 0.50). The characteristics on the occurrence of high temperature also displayed periodic wave form which is very similar to the pressure signal. And the amplitude of this profile goes larger as the fuel/air mixing quality become poorer. These also provided additional information on the perturbation of equivalence ratio at flame as well as NOx emission characteristics.

  • PDF

Emission Characteristics of GTL(Gas to Liquid) Fuel in Diesel Engine (디젤 엔진에서 GTL(Gas to Liquid) 연료의 배출물 특성에 관한 연구)

  • Lee, Yong-Gyu;Moon, Gun-Feel;Choi, Kyo-Nam;Jeong, Dong-Soo;Kim, Byoung-Jun;Cha, Kyung-Ok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.5
    • /
    • pp.84-91
    • /
    • 2008
  • Due to increasing need for better emission characteristics and lower fuel consumption rate in automotive engines, alternative fuels are drawing more attentions recently. The GTL (gas to liquid) is the one of most favored candidates. In this study, emission characteristics are compared between diesel and GTL fuel in commercial 2.0 liter diesel engine and vehicle with CRDi(Common Rail Direct injection) system. The effects of injection timings on emission and fuel consumption rate are compared at various engine speeds and loads. Noticeable reduction in HC, CO and PM emissions are observed due to higher cetane number and low sulfur and aromatic contents in GTL. On the trade-off curve of NOx and PM(Particulate matter) GTL showed much more benefits than diesel, where about 30% of PM mass decreased at the same operating conditions. On CVS 75 mode test in vehicle, GTL showed an excellent emission enhancement, in which 50% of HC, 21% of PM, and 12% of NOx engine-out emissions are decreased compared to ULSD(Ultra low sulfur diesel) fuel.

Assessment of Leak Detection Capability of CANDU 6 Annulus Gas System Using Moisture Injection Tests

  • Nho, Ki-Man;Kim, Wang-Bae;Sim, Woo-Gun
    • Nuclear Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.403-415
    • /
    • 1998
  • The CANDU 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside the calandria tube and the annulus between these tubes, which forms a closed loop with $CO_2$ gas recirculating, is called the Annulus Gas System(AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tube rupture incident. To judge whether the operator action time is enough or not in the design of Wolsong 2,3 & 4, the Leak Before Break(LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsong Units 2, 3, 4, a series of leak detection capability tests was performed by injecting controlled rates of heavy water vapour. The data of increased dew point and rates of rise were measured to determine the alarm set point for the dew point rate of rise of Wolsong Unit 2. It was found that the response of the dew point depends on the moisture injection rate, $CO_2$ gas flow rate and the leak location. The test showed that CANDU 6 AGS can detect the very small leaks less than few g/hr and dew point rate of rise alarm can be the most reliable alarm signal to warn the operator. Considering the present results, the first response time of dew point to the AGS $CO_2$ flow rate is approximated.

  • PDF

Effects of the Multi-Defects on Detecting Signals in Magnetic Flux Leakage System (자기누설탐상시스템에서 밀집된 다수의 결함이 탐상 신호에 미치는 영향)

  • Seo, Kang;Jeong, Hyun-Won;Park, Gwan-Soo;Lee, Min-Ho;Choi, Doo-Hyun;Lee, Seung-Hyun;Um, Chang-Gun;Shin, Pan-Seok;Kim, Chul;Rho, Yong-Woo;Yoo, Hui-Ryong;Cho, Sung-Ho;Kim, Dong-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.70-73
    • /
    • 2005
  • 자기누설탐상시스템은 지하에 매설된 가스관에서 발생되는 부식이나 크랙 또는 기계적 변형을 탐지하기 위한 방법으로 비파괴검사 방법의 하나이다. 가스관은 Nd자석에 의해 착자가 되고, 가스관에 부식이 발생했을 경우 가스관의 단면적이 작아지게 되어 자기누설이 발생하며, 발생된 자기누설을 홀센서로 검출하여 부식의 유무, 크기, 모양 등을 판별하게 된다. 가스관에는 한 개의 독립적인 부식도 있지만, 다수의 부식이 밀집되어 나타나기도 한다. 다수의 부식이 밀집되었을 경우 부식간의 거리에 따라 하나의 부식으로 판정되기도 하며, 그에 따라 부식의 깊이를 판정하는데 있어 정확성이 저감된다. 따라서 본 논문에서는 다수의 부식이 밀집되어 발생할 경우 자기적 영향을 분석하고, 깊이 판정에 있어 정확성을 높이기 위한 연구를 수행하였다. 이를 위해서 실제 결함을 제작하여 실험하고, 해석하여 비교하였으며 밀집된 다수의 부식에 의한 자기적 영향에 대하여 고찰하였다.

  • PDF

Smart Safety Helmet Using Arduino (아두이노를 이용한 스마트 안전모)

  • Lee, Dong-Gun;Kim, Won-Boem;Kim, Joong-Soo;Lim, Sang-Keun;Kong, Ki-Sok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.77-83
    • /
    • 2019
  • Major causes of industrial accidents include falls and gas leak. The existing safety helmet and smart device combination products are focused on convenience, so the functions to prevent such accidents are insufficient. We developed a smart helmet focusing on fall accident detection and gas leak detection. We also developed management system to manage workers efficiently. Its core function is to detect dangerous conditions of employees, to communicate with managers and to confirm the situations of workers. The effectiveness of the combustible gas measurement capability was verified through experiments. However, since a significant amount of power consumption is founded due to continuous operation of the board and the sensor, countermeasures such as replacing with a large capacity battery are required.

A Study on Cathodic Protection Rectifier Control of City Gas Pipes using Deep Learning (딥러닝을 활용한 도시가스배관의 전기방식(Cathodic Protection) 정류기 제어에 관한 연구)

  • Hyung-Min Lee;Gun-Tek Lim;Guy-Sun Cho
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.49-56
    • /
    • 2023
  • As AI (Artificial Intelligence)-related technologies are highly developed due to the 4th industrial revolution, cases of applying AI in various fields are increasing. The main reason is that there are practical limits to direct processing and analysis of exponentially increasing data as information and communication technology develops, and the risk of human error can be reduced by applying new technologies. In this study, after collecting the data received from the 'remote potential measurement terminal (T/B, Test Box)' and the output of the 'remote rectifier' at that time, AI was trained. AI learning data was obtained through data augmentation through regression analysis of the initially collected data, and the learning model applied the value-based Q-Learning model among deep reinforcement learning (DRL) algorithms. did The AI that has completed data learning is put into the actual city gas supply area, and based on the received remote T/B data, it is verified that the AI responds appropriately, and through this, AI can be used as a suitable means for electricity management in the future. want to verify.