DOI QR코드

DOI QR Code

Design Improvement of Vent System for Korean Utility Helicopter's Anti-Explosion Fuel Tank

한국형 기동헬기 내폭발성 만족을 위한 연료 벤트 시스템 설계개선

  • Received : 2013.08.30
  • Accepted : 2013.12.10
  • Published : 2014.01.01

Abstract

Military helicopter is exposed to the enemy gun firing due to the low altitude flight of contour flight, hovering & nap of the Earth flight, therefore it has the high possibility to be exploded by the gun firing. Recently the Anti-ballistic requirement is required to get the high level of safety from gun firing in required operational capability. The first military utility helicopter of SURION has the Anti-ballistic requirement and explosion proof. In order to meet the requirement, OBIGGS is adopted for the first time in KUH. It is proven that Anti-Explosion capability is satisfied to requirement for improving vent system which was insufficiently designed in development period and related to Anti-explosion.

군용 헬리콥터는 적 지역에 침투 시 저공비행 및 침투비행으로 인해 적의 소형화기에 노출되면서, 피탄에 의한 항공기의 폭발 유발 가능성이 높다. 최근 군요구도에 있어서 피탄에 의한 폭발 환경에 대해서 생존성 확보를 위한 내탄 성능을 요구한다. 국내 최초의 군용 헬리콥터인 한국형기동헬기의 연료계통 요구도에도 적의 피탄에 대한 내폭발성을 요구하고 있으며, 요구도 충족을 위해 국내 최초로 탑재형 불활성 가스발생장치(OBIGGS)를 적용하였다. 개발단계에서 미흡하게 설계된 내폭발성과 연관된 Vent System을 개선하여 내폭발성 성능을 재평가하고 설계에 적합함을 입증하였다.

Keywords

References

  1. HELICOPTER, UTILITY, Korea Defence Standard KDC 1450-T4001, 2012, pp.122
  2. AIRCRAFT EQUIPMENT INSTRUCTION, FUEL SYSTEM DRY CHECK A88AEI-28-0114, 2012, pp.16
  3. Aerospace Information Report SAE AIR 1903, 2008, pp.2
  4. Flight Test Report for Fuel System Test, 2012, pp.38
  5. Qualification by Analysis Report for KUH OBIGGS, 2012