• Title/Summary/Keyword: Guided surgery

Search Result 564, Processing Time 0.026 seconds

A Clinical Significance of Ultrasound Guided Aspiration Cytology in Diagnosis of Impalpable Thyroid Nodule (비촉지성 갑상선 결절의 진단에서 초음파 유도하 세침검사법의 임상적 가치)

  • Choi Nak-Seon;Yoon Jung-Han;JaeGal Young-Jong
    • Korean Journal of Head & Neck Oncology
    • /
    • v.15 no.2
    • /
    • pp.189-193
    • /
    • 1999
  • Objectives: Fine needle aspiration cytology(FNAC) is a well established preoperative diagnostic procedure in the thyroid nodules. However, diagnostic accuracy of FNAC varies according to the size and the structural characteristics of thyroid nodule. We performed the ultrasound guided FNAC(US-guided FNAC) for impalpable thyroid nodule, and estimated the sampling accuracy rate through a comparison study between the cytologic diagnosis and the final histologic diagnosis of the postoperative specimens in order to determine clinical efficacy of the US-guided FNAC. Materials and Methods: We evaluated 117 patients underwent US-guided FNAC from January 1997 to December 1998. These patients had 129 thyroid nodules to need cytologic examination. Whereas the nodules were so no graphically classified into cystic, solid, and mixed type according to echo pattern, the aspirated thyroid specimens were classified into benign, malignant, suspicious, and insufficient. Results: Positive sampling for diagnositc examination was achieved in 75 nodules(58.1%), and US-guided FNAC in our study showed the accuracy rate of 95.2%, false positivity rate of 0%, and false negativity rate of 5.5%. Conclusions: US-guided FNAC is a powerful techniques for evaluating cytologic characterics and allowing a reliable diagnositc result in the impalpable thyroid nodule. However, the experienced technique is recommanded in order to obtain the sufficient samples for reliable results.

  • PDF

A Randomized Comparative Study of Blind versus Ultrasound Guided Glenohumeral Joint Injection of Corticosteroids for Treatment of Shoulder Stiffness

  • Lee, Hyo-Jin;Ok, Ji-Hoon;Park, In;Bae, Sung-Ho;Kim, Sung-Eun;Shin, Dong-Jin;Kim, Yang-Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.3
    • /
    • pp.120-127
    • /
    • 2015
  • Background: We prospectively compared the response to blind and ultrasound-guided glenohumeral injection of corticosteroids for treatment of shoulder stiffness. Methods: A total of 77 patients with shoulder stiffness between April 2008 and March 2012 were recruited. Patients were randomized to receive either a blind (group 1, n=39) or ultrasound-guided (group 2, n=38) glenohumeral injection of 40 mg triamcinolone. The clinical outcomes and shoulder range of motion (ROM) before injection, at 3, 6, and 12 months after injection and at the last follow-up were assessed. The same rehabilitation program was applied in both groups during the follow-up period. Results: There was no significant difference in demographic data on age, sex, ROM, and symptom duration before injection between groups (p>0.05). There were no significant differences in ROM including forward flexion, external rotation at the side, external rotation at $90^{\circ}$ abduction, and internal rotation, visual analogue scale for pain and functional outcomes including American Shoulder and Elbow Surgeons score, Simple Shoulder test between the two groups at any time point (p>0.05). Conclusions: Based on the current data, the result of ultrasound-guided glenohumeral injection was not superior to that of blind injection in the treatment of shoulder stiffness. We suggest that ultrasound-guided glenohumeral injection could be performed according to the patient's compliance and the surgeon's preference. Once familiar with the non-imaging-guided glenohumeral injection, it is an efficient and reliable method for the experienced surgeon. Ultrasound could be performed according to the surgeon's preference.

CLINICAL USES OF HOMOLOGOUS GELATINIZED BONE MATRIX(GBM) IN DENTAL IMPLANT SURGERY (임플란트 식립시 동종뼈 막의 임상적 활용)

  • Lee, Eun-Young;Kim, Kyoung-Won;Um, In-Woong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.3
    • /
    • pp.229-236
    • /
    • 2006
  • The biologic principle of guided bone regeneration(GBR) has been studied extensively in hopes of regenerating alveolar bone. Various materials have been utilized as regenerative membranes and grafting materials in implant surgery. To improve the ability of membranes, several types of membrane have been developed. Various materials have been utilized as regenerative membranes; however, all materials have disadvantages, and the ideal membrane material is yet to be identified. In these cases, a homologous gelatinized bone matrix(GBM) were used as a regenerative material in conjunction with the placement of endosseous root implants. 22 patients participated in this study, and 42 implants were inserted. The result of 1st operative surgery was uneventful, inflammatory reaction and dehiscences were not observed except for only one case. After the final protheses, all implants were functioning successfully. The major advantages in the use of GBMs for guided bone regeneration are of very wide application such as membrane and graft material, and that a second procedure to remove the material is not necessary, and the GBMs are accepted by the surrounding tissues without complications. The purpose of this study was to observe the usefulness of GBMs in dental implant surgery.

Risk Factors for Wound Dehiscence after Guided Bone Regeneration in Dental Implant Surgery

  • Kim, Young-Kyun;Yun, Pil-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.3
    • /
    • pp.116-123
    • /
    • 2014
  • Purpose: The purpose of this study was to evaluate risks for wound dehiscence after guided bone regeneration (GBR) in dental implant surgery. Methods: Patients who received dental implant therapy with GBR procedure at Seoul National University Bundang Hospital (Seongnam, Korea) from June 2004 to May 2007 were included. The clinical outcome of interest was complications related to dental implant surgery. The factors influencing wound dehiscence, classified into patient-related factors, surgery-related factors and material-related factors, were evaluated. Results: One hundred and fifteen cases (202 implants) were included in this study. Wound dehiscence (19.1%) was considered a major complication. The risk of wound dehiscence was higher in males than in females (odds ratio=4.279, P =0.014). In the main graft, the allogenic group had the lowest risk of wound dehiscence (odds ratio=0.106, P =0.006). Though the external connection group had a higher risk of wound dehiscence than the internal connection group (odds ratio=2.381), the difference was not significant (P =0.100). Conclusion: In this study, male gender and main graft have the highest risk of wound dehiscence. To reduce wound dehiscence after GBR, instructions on postoperative care with supplementary procedure for the protection of the wound dehiscence is recommended, especially to male patients. A main graft with a gel base can reduce the risk of wound dehiscence.

Minimally Invasive Approach to Esophageal Perforation after Endoscopic Ultrasound-Guided Fine-Needle Aspiration: A Report of 2 Cases

  • Geraedts, Anna C.M.;Broos, Pieter P.H.L.;Gronenschild, Michiel H.M.;Custers, Frank L.J.;Hulsewe, Karel W.E.;Vissers, Yvonne L.J.;de Loos, Erik R.
    • Journal of Chest Surgery
    • /
    • v.53 no.5
    • /
    • pp.313-316
    • /
    • 2020
  • Esophageal perforation after endoscopic ultrasound-guided fine-needle aspiration for mediastinal staging is a rare but severe complication. We report 2 cases of patients with esophageal perforation who were treated using video-assisted thoracoscopic surgery in combination with esophageal stenting. Through these cases, the feasibility of minimally invasive thoracic surgery was evaluated.

Computer-Assisted Mandibular Reconstruction with Monocortical DCIA Flap; A Case Report

  • Moon, Seong-Yong
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.2
    • /
    • pp.83-86
    • /
    • 2015
  • Recently, computer-assisted surgery is popular for performing well-planned operations. Computer-aided navigation system is helpful in maxillofacial surgery with real time instrument positioning and clear anatomic identification. Generally, segmental mandibulectomy and reconstruction flap surgery have done by extra-oral approach such as, submandibular approach. This case report describes performing intra-oral segmental mandibulectomy and reconstruction with monocortical deep circumflex iliac artery (DCIA) flap and CT guided implant surgery by using computer-aided surgical guide and navigation for managing ameloblastoma in a 31 years old female patient.

Full mouth rehabilitation with Implant-Guided Surgery and Fixed prosthesis (Implant-Guided Surgery를 이용한 고정성 임플란트 보철물의 전악 수복 증례)

  • Kim, Seong-Mo;Park, Jin-Hong;Ryu, Jae-Jun;Shin, Sang Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.126-133
    • /
    • 2018
  • The development of cone beam computerized tomography (CBCT) allows three-dimensional analysis of the patient's anatomy. The surgical guide is a combination of CBCT, computer-aided design/computer-aided manufacturing (CAD/CAM) and implant diagnostics software, which allows well planned prostheses design and ideal implant placement. Guided surgery minimizes possible anatomical damage and allows for more reproducible treatment planning. In this case, the operation time was shortened by using a surgical guide for multiple implants placement in a fully edentulous patient. Immediate loading were performed more easily using preliminary preparation of provisional prosthesis. The patient was satisfied with improved esthetics and chewing function.

Accuracy and Safety in Pedicle Screw Placement in the Thoracic and Lumbar Spines : Comparison Study between Conventional C-Arm Fluoroscopy and Navigation Coupled with O-Arm$^{(R)}$ Guided Methods

  • Shin, Myung-Hoon;Ryu, Kyeong-Sik;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.3
    • /
    • pp.204-209
    • /
    • 2012
  • Objective : The authors performed a retrospective study to assess the accuracy and clinical benefits of a navigation coupled with O-arm$^{(R)}$ system guided method in the thoracic and lumbar spines by comparing with a C-arm fluoroscopy-guided method. Methods : Under the navigation guidance, 106 pedicle screws inserted from T7 to S1 in 24 patients, and using the fluoroscopy guidance, 204 pedicle screws from T5 to S1 in 45 patients. The position of screws within the pedicle was classified into four groups, from grade 0 (no violation cortex) to 3 (more than 4 mm violation). The location of violated pedicle cortex was also assessed. Intra-operative parameters including time required for preparation of screwing procedure, times for screwing and the number of X-ray shot were assessed in each group. Results : Grade 0 was observed in 186 (91.2%) screws of the fluoroscopy-guided group, and 99 (93.4%) of the navigation-guided group. Mean time required for inserting a screw was 3.8 minutes in the fluoroscopy-guided group, and 4.5 minutes in the navigation-guided group. Mean time required for preparation of screw placement was 4 minutes in the fluoroscopy-guided group, and 19 minutes in the navigation-guided group. The fluoroscopy-guided group required mean 8.9 times of X-ray shot for each screw placement. Conclusion : The screw placement under the navigation-guidance coupled with O-arm$^{(R)}$ system appears to be more accurate and safer than that under the fluoroscopy guidance, although the preparation and screwing time for the navigation-guided surgery is longer than that for the fluoroscopy-guided surgery.

An assessment of accuracy of half-guided implant surgery using implant surgical guide: A case report (임플란트 수술용 가이드를 사용한 부분 유도 임플란트 수술의 정확도 평가: 증례보고)

  • Kim, Choongkil;Lee, Wonsup;Kwon, Ho-Beom
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.150-159
    • /
    • 2019
  • Nowadays, dental implant is one of the widely used treatment options for edentulous patients. Recently, a method of improving the accuracy of implant surgery using an implant surgical guide has been introduced and widely used in order to accurately place the implant in a proper position. Full-guided and half-guided implant surgery can be distinguished according to the level of surgical guide application during the implant surgery. It is true that full-guided implant surgery exhibits higher accuracy, but half- guided implant surgery is often performed in a clinical situation due to the factors such as the circumstances of the operation. A partially edentulous patient who lost teeth due to tooth fracture and periodontal disease was treated using implant and fixed prosthesis. Half-guided implant surgery was performed using an implant surgical guide during implant surgery, the accuracy of implant placement was analyzed.

Chitin-fibroin-hydroxyapatite membrane for guided bone regeneration: micro-computed tomography evaluation in a rat model

  • Baek, Young-jae;Kim, Jung-Han;Song, Jae-Min;Yoon, Sang-Yong;Kim, Hong-Sung;Shin, Sang-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.14.1-14.6
    • /
    • 2016
  • Background: In guided bone regeneration (GBR) technique, many materials have been used for improving biological effectiveness by adding on membranes. The new membrane which was constructed with chitin-fibroin-hydroxyapatite (CNF/HAP) was compared with a collagen membrane (Bio-$Gide^{(R)}$) by means of micro-computed tomography. Methods: Fifty-four rats were used in this study. A critical-sized (8 mm) bony defect was created in the calvaria with a trephine bur. The CNF/HAP membrane was prepared by thermally induced phase separation. In the experimental group (n = 18), the CNF/HAP membrane was used to cover the bony defect, and in the control group (n = 18), a resorbable collagen membrane (Bio-$Gide^{(R)}$) was used. In the negative control group (n = 18), no membrane was used. In each group, six animals were euthanized at 2, 4, and 8 weeks after surgery. The specimens were analyzed using micro-CT. Results: Bone volume (BV) and bone mineral density (BMD) of the new bone showed significant difference between the negative control group and membrane groups (P < 0.05). However, between two membranes, the difference was not significant. Conclusions: The CNF/HAP membrane has significant effect on the new bone formation and has the potential to be applied for guided bone regeneration.